Key takeaways

  • A tank-to-tankless conversion is not a swap. The real work is new venting, a larger gas supply, condensate drainage and, in many New Westminster homes, dealing with the chimney the old tank was vented into.
  • Ballpark installed cost for a tank-to-tankless conversion in Greater Vancouver runs about $4,500 to $8,000 and up before GST, with a straight tankless installation closer to $3,900 to $7,800. These are ranges for orientation, not a quote.
  • Gas-fitting and most electrical work in BC are restricted to licensed trades, and the permit and inspection path in New Westminster is part of the job, not an optional extra.
  • Metro Vancouver water is soft, so descaling a tankless unit here is about heat-driven mineral deposits and debris rather than heavy limescale. It still needs doing on the manufacturer’s schedule.
  • If your old tank vented into a shared or oversized masonry chimney, abandoning or relining that flue is a carbon monoxide safety issue and must be handled by the licensed technician doing the work.
  • Sometimes the honest answer is a new tank. Small mechanical rooms, undersized gas service and long vent runs can push a conversion past what it returns.

Converting a gas tank water heater to a gas tankless unit in a New Westminster home means replacing one appliance and then rebuilding the services around it. A condensing tankless unit fires at a much higher input than the tank it replaces, so it needs a gas supply sized for that load, it vents through sealed plastic or stainless pipe out a sidewall rather than up the old chimney, it produces acidic condensate that has to be drained and usually neutralised, and it needs a dedicated power supply. In New Westminster’s housing stock, which leans heavily toward pre-war character homes, post-war bungalows with low basements, and newer strata buildings near the Quay and Uptown, the deciding factors are almost always the vent route, the gas line and the mechanical space, not the appliance itself. This page walks through how that job actually runs, what you decide along the way, and when a like-for-like tank replacement is the smarter call.

What actually changes when you convert from a tank to a tankless in a New Westminster house?

The appliance is the smallest part of the change. A gas tank water heater in an older New West basement is typically a low-input atmospheric unit that draws its combustion air from the room and dumps flue gas up a masonry chimney or a shared B-vent. A condensing gas tankless unit fires only when you open a tap, but when it fires it demands far more gas than the tank ever did, and it exhausts cool, wet, acidic flue gas that must never go up a masonry chimney.

So the conversion touches five separate systems at once: gas supply, venting and combustion air, condensate handling, electrical, and the water piping at the appliance. Each one can be straightforward or can be the thing that sets the price and the schedule. A licensed gas fitter sizes all of it before anything is ordered, because guessing at gas pipe capacity or vent length is exactly how a job stalls at inspection.

The other change is behavioural. A tank stores hot water and a tankless makes it on demand, so flow rate rather than stored volume decides what your household can run at once. That is a sizing conversation with your installer based on your fixtures and your incoming water temperature, and it is one of the reasons a site visit matters more here than on a straight tank swap.

  • Gas: a larger branch line, and sometimes a meter capacity review with the utility, to feed the higher firing rate.
  • Venting: sealed manufacturer-approved vent pipe through a sidewall, with a terminal kept clear of windows, doors, walkways and the property line.
  • Combustion air: usually drawn directly from outdoors through a concentric or two-pipe arrangement, which frees the mechanical room from needing a large air opening.
  • Condensate: a drain route with a neutraliser, sloped correctly, and often a small condensate pump when the unit sits below the nearest drain.
  • Electrical: a dedicated circuit and receptacle for the unit’s controls, fan and, on some models, an internal recirculation pump.

Which New Westminster homes convert easily, and which ones fight back?

New Westminster’s older neighbourhoods are the deciding variable. Queen’s Park and Glenbrooke North are full of character houses with full-height basements, solid framing, and an old brick chimney that the furnace and water heater were both tied into. Those basements usually have a workable exterior wall for a sidewall vent, but the chimney question comes with the job because removing the water heater from a shared flue changes how that flue behaves for whatever is left on it.

The Brow of the Hill, Sapperton and Connaught Heights bring steep lots and narrow side yards. That matters because a vent terminal needs clearance from windows, doors, mechanical air intakes, decks and the property line, and on a narrow New West lot the nearest available wall may be a metre or two from the neighbour’s house. Sometimes the answer is a different wall, sometimes it is a longer vent run through the joist space, and sometimes it means re-siting the appliance entirely.

Post-war bungalows in Victory Heights and Massey Heights often have lower basement ceilings and finished rec rooms, which makes routing a new gas line and a vent through finished space the real cost driver. And houses with a legal or long-standing secondary suite, which are common across the city, change the hot water demand picture: two kitchens and two bathrooms on one unit needs honest sizing, not optimism.

Strata apartments and townhouses near the Quay, Downtown and Uptown are a separate world. In a multi-unit building, the exterior wall, the shaft and the gas riser are common property. Nothing gets vented through a common wall without written strata approval, and in many buildings the answer from the strata is simply no, which is worth confirming before any other planning.

How does the venting work, and what happens to the old chimney?

Condensing tankless units vent with sealed, manufacturer-approved pipe, run to a terminal in an exterior wall. The maximum equivalent length, the allowable number of elbows and the required clearances are all manufacturer-published, so your installer verifies them against the manual for your specific model rather than working from a rule of thumb. On a New Westminster lot the clearance rules, not the pipe length, are usually what dictates the route.

The old chimney is the part homeowners underestimate. If your water heater was the only appliance on a masonry chimney, that flue becomes orphaned and should be properly abandoned and capped so it stops acting as a cold, damp shaft into the house. If a gas furnace or a gas boiler is still vented into it, pulling the water heater off leaves a flue that is now oversized for the remaining appliance. An oversized flue runs cooler, drafts poorly, and can spill combustion products into the house. That is a carbon monoxide hazard, and it is why a liner or a vent reconfiguration is often part of the conversion rather than a separate project for later.

This is also the moment to look at whether the furnace or boiler is near the end of its own life. If it is, doing the water heater and the heating appliance together usually means one venting solution instead of two, one permit process, and one set of wall penetrations. If you are considering a dual-fuel setup, a heat pump paired with your gas furnace kept as backup for cold snaps, sequencing that with the water heater work is worth raising at the site visit.

What does the gas line, meter and electrical side really involve?

A condensing tankless unit fires at a much higher rate than the tank it replaces, and gas pipe sizing depends on the total connected load, the length of the run and the number of fittings. In an older New West house where the existing half-inch branch was sized for a modest tank, the usual outcome is a new, larger dedicated run from the meter or from a suitably sized point on the existing system. The gas fitter calculates this; the homeowner does not.

Occasionally the total load across the furnace, range, fireplace, dryer and the new tankless unit exceeds what the existing meter and service can deliver. That triggers a capacity review with the utility, and it is better discovered during the quote than during commissioning. Ask directly whether your load calculation clears your current meter.

Electrical is smaller but not optional. The unit needs a dedicated circuit and a receptacle within reach, and if the panel is a crowded older one there may be no straightforward space for it. Electrical work of this kind belongs to a licensed electrician in BC. Between a new gas run, a new circuit and a condensate route, the trades on site need coordinating, which is one of the reasons a conversion has a longer day than a tank swap.

Element of the conversionWhat it involvesWhat drives the cost or delay
Gas supplyNew or upsized branch line sized to the connected loadDistance from the meter, finished ceilings, crawl space access
Meter and serviceLoad calculation across every gas appliance in the houseUtility review and scheduling if capacity is short
VentingSealed manufacturer-approved vent and intake to an exterior wallClearances on a narrow lot, run length, penetrations through finished space
Old chimneyAbandon and cap, or reline for the remaining applianceWhether a furnace or boiler still vents into it; masonry condition
CondensateSloped drain line plus a neutraliser cartridgeDistance to a suitable drain; a pump when the unit sits low
ElectricalDedicated circuit and receptacle for controls and fanPanel space and the route from the panel to the unit
Water pipingReworked supply and service valves with isolation and flush portsGalvanised or mixed old piping that has to be transitioned
Permits and inspectionGas and electrical permits, with inspection before closing anything upMunicipal scheduling; strata approval in an apartment or townhouse

What does a tank-to-tankless conversion cost in New Westminster?

As a ballpark, a tank-to-tankless conversion in Greater Vancouver commonly lands somewhere around $4,500 to $8,000 and up installed, before GST. These are ballpark figures for orientation only. They are not a quote, and an accurate price needs a site visit, because the vent route and the gas line are what actually set the number in your particular house.

For context, a tankless installation where the gas line and the vent route are already suitable tends to sit closer to $3,900 to $7,800 installed. A like-for-like atmospheric gas tank replacement is usually in the $1,800 to $3,000 range, and a power vent gas tank is more like $2,800 to $4,500. If the conversion needs a new gas run, that work commonly runs about $500 to $1,500 where the route is short and accessible, and $1,500 to $3,000 or more where it is long or difficult. All of those are wide ranges on purpose.

Permit fees are set by the municipality or by Technical Safety BC and are separate from the installed price, so ask your contractor how permits are handled on your job. Rebates and incentive programs for efficient water heating change over time and have their own eligibility rules; ask about what is currently available and confirm it with the administering program rather than treating any figure as fixed. Financing, if you use it, is its own conversation.

What moves the price, in rough order of impact: the length and difficulty of the vent run, whether a new or upsized gas line is needed, what happens to the old chimney, condensate routing and whether a pump is required, electrical panel work, access to the mechanical space, permit and inspection coordination, removal and disposal of the old tank, and any code upgrades the inspection brings to light on work that predates current requirements.

Which tankless features are worth deciding on before install day?

The single decision that changes the most about how the system feels day to day is recirculation, because it determines how long you wait for hot water at the far fixture. There are three genuinely different approaches and they are not interchangeable.

A unit with a built-in pump has the pump inside the appliance, which keeps the install tidy but still needs a return path in the plumbing to be fully effective. An external pump on a dedicated return line is the traditional approach and gives the most control, but it requires that a return line exists or can be run, which in a finished New West basement can be the expensive part. A crossover or bypass-valve retrofit uses the cold line as the return through a thermostatic valve under the farthest fixture, which avoids opening walls but warms the cold line while it runs and suits some households better than others.

Bradford White and Rheem are two manufacturers we service and install. Bradford White’s Infiniti K Series is offered in indoor and outdoor versions without a built-in pump but wired for an external one; the Infiniti L Series and the newer Infiniti GR Series include a built-in recirculation pump, and the Infiniti GS Series is the GR’s companion without the pump. Rheem’s IKONIC S Series is condensing, with the IKONIC SR Series adding a built-in recirculation pump, alongside the Prestige RTGH condensing series with Canadian variants, the RTG non-condensing line including the RTG-R recirculation version, and the Performance Platinum retail line. Rheem indoor units can be converted for outdoor use with a manufacturer kit. Capacities, flow rates and vent limits are manufacturer-published and should be verified for your exact model. As an independent TSBC-licensed contractor we are not a factory-authorised dealer for any brand; we service and install what suits the house.

Indoor versus outdoor siting is the other early decision. An outdoor unit removes the venting problem entirely and frees up basement space, which is attractive on a tight New Westminster lot, but it needs a sheltered location, freeze protection and power at the wall. Indoor siting keeps the unit protected but puts the vent clearances back at the centre of the plan.

How does the job run, from quote to final inspection?

A conversion starts with a site visit rather than a phone estimate, because half of what sets the price cannot be seen from a photo. The technician measures the mechanical space, traces the existing gas system and calculates the load, finds a viable vent route with legal clearances, identifies the condensate drain, checks the panel, and looks at what else is on the chimney.

From there you get a scope that names the model family, the venting approach, the gas work, the electrical work and how the old chimney is handled. Permits are pulled before the work, and the installation is inspected before anything is closed in. In a strata, written approval comes before any of this.

Install day is usually a full day and sometimes longer when a gas run passes through finished ceilings or the panel needs attention. Water is off for part of it. The old tank is drained, disconnected and removed for disposal. At commissioning the technician sets up the unit, confirms gas pressure under load, verifies the venting, checks for leaks, runs the condensate and neutraliser, and walks you through the controls, the isolation valves and the flush procedure.

After that, the maintenance rhythm changes. A tank needed little attention until it failed; a tankless unit wants an annual look at the inlet filter, the condensate neutraliser and the flush schedule the manufacturer specifies. Same-day work is sometimes possible on a straightforward repair or a like-for-like tank replacement, but a conversion involves permits, materials and coordinated trades, so it is planned work and we will not promise a guaranteed arrival window.

When is converting the wrong answer, and a new tank the right one?

We would rather talk you out of the wrong job than sell you one. There are real cases in New Westminster where a like-for-like tank replacement, or a move to a power vent tank, is the better decision.

If your gas service and meter are at capacity and the utility upgrade is the only path forward, the conversion stops being about a water heater. If there is no legal vent route because of side-yard clearances, or the only viable wall faces a neighbour’s window, the same applies. In a strata apartment, if the exterior wall and the shaft are common property and approval is not forthcoming, the conversion simply is not available to you.

There are household reasons too. If your hot water use is modest and steady, if you are planning to sell in the near term, or if the mechanical space will be reworked for a heating system change soon anyway, spending the conversion budget on a solid tank now and revisiting later is a defensible plan. A power vent tank is often the middle path: it sidesteps the chimney by venting out a sidewall, it handles a mechanical room that cannot supply enough combustion air, and it costs meaningfully less than a full conversion.

The one thing we would not do is leave an orphaned or oversized flue unaddressed to save money on either path. That is a safety decision, not a budget one.

When should you call a licensed technician?

In British Columbia, gas fitting is restricted to licensed gas fitters and most electrical work is restricted to licensed electricians. That covers essentially every part of a tank-to-tankless conversion: sizing and running gas pipe, connecting the appliance, installing and terminating the vent, altering the chimney, and adding the circuit. None of it is homeowner work, and doing it without a permit and inspection puts both safety and insurance at risk.

  • A homeowner may reasonably do: keep the area around the unit and the vent terminal clear, check that vent and intake terminals are not blocked by snow, leaves or landscaping, test carbon monoxide alarms, watch for water on the floor, and keep records of the model and serial number.
  • A licensed technician must do: all gas piping and connections, load and pipe sizing, vent design and installation, chimney lining or abandonment, condensate neutraliser installation, descaling and flushing on the manufacturer’s schedule, and any refrigerant work on related heating equipment.
  • A licensed electrician must do: the dedicated circuit, receptacle and any panel work.
  • Call right away if you smell gas, if a carbon monoxide alarm sounds, if you see soot or scorching near an appliance, if a burner flame is yellow and lazy rather than crisp and blue, or if the unit shows a fault code and shuts down repeatedly.
  • Call soon, not urgently, if hot water output is dropping, if the unit is short-cycling on low flow, if you hear a new rumble or knock, or if the condensate line is backing up.
Gas & carbon-monoxide safety: Gas and carbon monoxide safety come first on this job. If you smell gas, do not operate switches or appliances, leave the building, and call from outside; report it to the gas utility and to a licensed gas fitter. Carbon monoxide is odourless and colourless, so working CO alarms belong on every level of the home, including outside sleeping areas, and they need testing on a schedule. A conversion carries a specific hazard that a straight replacement does not: removing the water heater from a masonry chimney can leave that flue orphaned or oversized for whatever appliance remains on it, which causes poor draft and can spill combustion products into the house. That flue must be properly abandoned and capped or relined as part of the work, not left for later. Gas fitting and most electrical work in BC are restricted to licensed trades, permits and inspection are part of a lawful installation, and refrigerant work on any related heat pump or air conditioning equipment is legally limited to certified technicians. BC Wide Home Services Ltd is an independent TSBC-licensed contractor, licences LGA0090068 and CGA0028029. Call (604) 473-9690.

Frequently asked questions

Can a tankless unit just be hung where my old tank was in a New Westminster basement?

Often it can, and the wall space a tankless unit frees up is one of the real benefits in a tight basement. What decides it is whether a legal vent route exists from that spot to an exterior wall with proper clearances, whether the gas line can be brought to it at the right size, and whether a condensate drain is within reach. In older houses the unit sometimes ends up a few metres from where the tank stood for exactly those reasons.

Do I need a permit for a tank-to-tankless conversion in New Westminster?

Yes. Gas work requires a permit and inspection, and the added electrical circuit does too. Permit fees are set by the municipality or by Technical Safety BC, so confirm the current amounts with them rather than relying on a number you read anywhere. Your contractor should pull the permits and arrange the inspection as part of the job, and you should ask for that in writing.

Will hard water ruin a tankless unit here?

Metro Vancouver water is soft and cold, so the heavy limescale problem that dominates tankless advice from other regions does not apply the same way here. Deposits still form from heat driving minerals out of solution, and debris still collects at the inlet filter, so a periodic flush on the manufacturer’s schedule is genuinely worth doing. Treat it as normal maintenance rather than an emergency.

How long will I be without hot water on install day?

Plan for most of a working day without hot water, and longer if the gas run has to pass through finished ceilings or if the electrical panel needs work. The old tank has to be drained and removed, new gas and vent runs installed, and the unit commissioned and leak-tested before it is handed over. Your installer should give you a realistic window at the site visit rather than a guess over the phone.

I live in a condo near the Quay. Can I convert?

Usually not without written strata approval, and in many buildings not at all. The exterior wall, the vent shaft and the gas riser are common property, and a new penetration or a change to the gas load affects the building, not just your unit. Start by asking the strata what is permitted before you spend time on equipment selection.

Is a recirculation pump worth adding during the conversion?

It is worth deciding on during the conversion rather than after, because a dedicated return line is far cheaper to run while things are open. A unit with a built-in pump keeps the install tidy, an external pump on a dedicated return gives the most control, and a crossover valve under the farthest fixture avoids opening walls but warms the cold line while it runs. Which one fits depends on your layout and how far your farthest tap is from the unit.

What if my furnace still vents into the same chimney?

Then the chimney becomes part of the scope. Removing the water heater leaves that flue oversized for the remaining appliance, which hurts draft and can spill combustion products into the house. The fix is typically a properly sized liner or a change in how the furnace vents, and it must be done by the licensed technician performing the work. If the furnace is also near end of life, doing both at once usually saves a set of penetrations and a second permit cycle.

Can I keep my gas furnace if I later add a heat pump?

Yes, and that is the approach we lead with in this climate. A dual-fuel setup pairs a heat pump with your existing gas furnace, which stays as backup for cold snaps, so you keep a proven heat source for the coldest days. If that is on your horizon, mention it during the water heater site visit so the gas load calculation and any mechanical room changes account for it in advance.

BC Wide Home Services — Lower Mainland home-comfort specialists since 1999

Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians · Evening and weekend calls · Diagnostic service calls $189.00 · Free in-home estimates on replacements (the $189.00 is waived if you replace with us). Call 604-473-9690 or book a free replacement estimate.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How long does a hot water tank last?
A standard gas or electric storage tank lasts 8–12 years. A high-quality tank with annual anode rod inspection can reach 15 years. Tankless water heaters typically last 18–22 years when descaled annually in Metro Vancouver's moderately hard water.
Should I switch to a tankless water heater?
Tankless makes sense if you have high demand (large family, multiple bathrooms running at once), want to free up floor space, or value endless hot water. Upfront cost is higher ($3,500–$6,000 installed vs $1,800–$3,200 for a tank) but operating cost is 25–40% lower for gas tankless.
My hot water tank is leaking — is it an emergency?
If the leak is from the tank body itself (not a valve or fitting), the tank is at end of life and needs replacement, usually within 24–48 hours before it floods. Shut off the water supply and gas/electric to the tank and call us.
What brands of water heaters do you install?
We install and service Bradford White, Rheem, AO Smith, John Wood, Giant, GSW for storage tanks; and Navien, Rinnai, Noritz, Bosch and Rheem for tankless units.
Can I install a water heater myself?
In BC, gas water heater installations must be performed by a TSBC-licensed gas fitter and are subject to permit and inspection. Electric tanks require a licensed electrician for the connection. BC Wide handles permits as part of every installation.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote