Laars boiler error code E45 means the control reads the air pressure sensor (APS) circuit as open, so the boiler goes into a soft lockout and will not light the burner until the fault clears. Confirm that meaning against the manual for your unit. You can safely check power, the thermostat, the outdoor vent and intake terminals and the visible condensate drain. Wiring, sensor tubing, the blower and the sensor itself are work for a licensed gas technician. Call BC Wide at (604) 473-9690.
If your Laars boiler is showing E45 (Air pressure sensor (APS) open), here’s exactly what it means and what to do. This guide is part of our full Laars boiler error code list.
Severity: Needs attention.
What E45 means on a Laars boiler
The air pressure sensor circuit reads open. Soft lock.
Common causes
- Disconnected or damaged APS wiring
- Air pressure sensor fault
What you can safely check first
- Confirm the boiler has power
- Record the code for your technician — APS service is a pro task
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Laars boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Laars boiler repair across Greater Vancouver
If a Laars boiler showing E45 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Laars boiler codes
- Laars boiler E10 — Flame extinguished 8 times
- Laars boiler E11 — Ignition failed 10 times
- Laars boiler E16 — Over-temperature (water above 203°F / 95°C)
- Laars boiler E20 — Condensate drain trap fault
- Laars boiler E28 — Overheat sensor open or short
- Laars boiler E32 — DHW (hot water) sensor open or short
Frequently asked questions
Is E45 on a Laars boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Laars boilers 7 days a week across Greater Vancouver.
How do I reset a Laars boiler after E45?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Laars Boiler Error Code E45: what it means for your heat and hot water
A modern sealed-combustion boiler uses a fan, usually called the combustion blower or inducer, to pull outside air in through the intake pipe, push it through the burner and send the flue gases out through the exhaust pipe. Before the burner is allowed to light, the control wants proof that air is really moving through that path the way the design expects. The air pressure sensor gives it that proof. When the control sees the APS circuit as open, it cannot confirm that the venting is working, so it refuses to light. That is a deliberate safety stop, not a random glitch. The page above describes E45 as a soft lock, which generally means the boiler can try again on its own once the condition clears, instead of demanding a manual reset every time. Confirm against the manual for your unit.
What you actually notice depends on how your Laars boiler is set up. If it heats the house only, the radiators, baseboard convectors or in-floor loops go lukewarm and then cold. If it also heats an indirect hot water tank, you may run out of hot water a few hours later as the tank cools down. If it is a combination unit serving both heat and domestic hot water, you lose both at once. In owner words, these are the complaints we hear most often on an E45 call:
- The thermostat is calling for heat but the radiators or floors are cold or barely warm.
- The display shows E45 and the burner never lights.
- You hear the fan start, run for a short while and then stop without the burner firing.
- Hot water runs out sooner than normal or turns cold, if the boiler also heats your water.
- The code clears, the boiler runs for a day or two, and then E45 comes back, often during windy or very wet weather.
- There is gurgling near the boiler, or water dripping or pooling around the vent pipe or under the cabinet.
- Leaves, a nest or debris are visible at the vent terminals where the pipes leave the house.
Likely causes of Laars boiler error code E45, most common first
An air pressure sensor that reads open is very often reporting a real airflow problem honestly. That is why we never start an E45 job by swapping the sensor. In our experience on sealed-combustion boilers, the cause list below runs roughly from most common to least common, but every boiler and every venting layout is different, and the order on your system may differ. Confirm any part-specific detail against the manual for your unit.
The pattern of the fault tells us a lot. An E45 that only appears in storms points toward the terminals and wind. One that appears after a long run points toward condensate backing up. One that appears on every single start, in any weather, points toward wiring, tubing, the blower or the sensor. Write down when it happens before we arrive; it shortens the diagnosis.
| Likely cause | What the owner may notice | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| Blocked or restricted outdoor intake or exhaust terminal (leaves, needles, snow, a bird or wasp nest) | Code appears after a storm or in autumn; fan runs but burner will not light | Look at both terminals from outside and clear loose leaves or snow by hand from the outside only | A nest inside the pipe, a damaged or crushed terminal, or the code returns after clearing |
| Condensate backing up into the boiler (blocked trap, kinked drain line, full or failed condensate pump, clogged neutralizer) | Gurgling, water under the boiler, code after long run times | Look at the visible drain tube for kinks, a disconnected end or standing water; do not take the trap apart | Any water inside the cabinet, a trap that needs cleaning or a pump that is not running |
| Sensing tube to the APS cracked, kinked, disconnected or holding water | Intermittent E45 with no obvious outside cause | None; the tube is inside the cabinet | Always, because the cabinet must be opened |
| Loose, corroded or damaged APS wiring or connector | Code on every start, or code that comes and goes after someone worked near the boiler | None beyond confirming power to the boiler | Always; this is electrical work inside a gas appliance |
| Combustion blower weak, dirty or not reaching full speed | Fan sounds different, slower or noisier than usual before the code shows | Note the sound and when it happens | Always; blower testing needs meters and the manufacturer’s specification |
| Air pressure sensor itself has failed | Code on every start with venting and condensate confirmed clear | None | Always; only after the airflow path is proven good |
| Venting run modified or installed poorly (too long, sagging, wrong slope, bad joints) | Code started after a renovation, deck build or siding work near the terminals | Note any recent work near the pipes | Always; venting changes need a licensed gas fitter and, in most cases, a permit |
Can I fix Laars boiler error code E45 myself? The checks that are allowed
Some of the most common E45 causes are outside the boiler, which means there are a few useful things a homeowner can safely look at. Everything below is done without opening the boiler cabinet, without touching gas fittings and without disturbing wiring. In British Columbia, work on gas appliances and gas piping is restricted to licensed gas fitters under Technical Safety BC, and most electrical work inside the appliance is restricted to licensed trades as well, so the line between what you may do and what we must do is a legal one, not just good advice.
- Power and switch: make sure the boiler’s service switch, usually a light-type switch near the unit or at the top of the basement stairs, is on, and that the breaker feeding it has not tripped. Do not remove the front panel to check anything inside.
- Gas supply valve: the manual shut-off on the gas line to the boiler is normally open when the handle lines up with the pipe. Look, do not force it, and never use a tool on a gas fitting. A closed gas valve usually causes a different kind of lockout, but it is worth confirming.
- Thermostat calling: set the thermostat a few degrees above room temperature and replace its batteries if it uses them, so you know the boiler is actually being asked for heat.
- Outside intake and exhaust terminals: go outside and find where the two plastic pipes leave the house. Clear loose leaves, needles or snow by hand from the outside. Do not push anything into the pipes, do not spray into them and do not try to pull out a nest; that is a service call.
- Visible condensate drain: follow the small clear or white tube from the boiler to the floor drain or condensate pump. Note if it is kinked, disconnected, sitting under water or if water is pooling under the boiler. Do not take the trap or the neutralizer apart.
- One reset, only if the owner manual allows it: if your manual describes a reset for this condition, do it once. If E45 returns, stop. Repeated resetting does not fix an airflow fault and can hide a real venting problem.
- Record what you see: take a photo of the display and of the rating plate, and note the time of day, the weather and whether the fan ran before the code appeared. That information goes straight into our diagnosis.
How our Laars boiler E45 repair visit works, step by step
Every E45 call follows the same order, because the order is what stops a technician from replacing a perfectly good sensor while the real problem sits in the venting or the condensate path. This is what you should expect from us, and what you should expect from any licensed contractor you hire.
- The phone call: when you call (604) 473-9690, we ask about the code, when it appears, the weather, any recent work near the vent pipes, and whether you have hot water. We offer same-day service where we can, and we tell you honestly when the schedule does not allow it. We never promise a guaranteed arrival window.
- Safety first on arrival: before diagnosing anything, the technician checks for gas leaks around the boiler and piping and takes a carbon monoxide reading in the room.
- Fault history: we read what the control has stored, so we know whether E45 is new, frequent or mixed with other lockouts.
- Venting and intake, end to end: we inspect both terminals, the full pipe run, the slope back toward the boiler, joints, supports and clearances from windows, doors and grade.
- Condensate path: we check the trap, drain line, neutralizer and any condensate pump, because water backing up into the boiler is one of the most common reasons an air pressure sensor reads wrong.
- Measurement, not guesswork: with a manometer we read the pressure the blower actually produces and compare it with the manufacturer-published value for your model. With a multimeter we check continuity of the APS circuit, the sensor and the wiring. We inspect the sensing tube for cracks, kinks and water.
- Explanation and written quote: we tell you in plain words what we found and why. Diagnosis is the first step; any work beyond diagnosis is quoted in writing before we start, and nothing proceeds without your approval.
- Repair with correct parts, then test the safeties: after the repair we confirm the air pressure sensor proves and opens as it should, check flame sensing and the high limit, run a combustion analysis and watch the boiler through several full heating cycles.
- Paperwork you keep: you receive a written record of what was found, what was done and the readings taken, which is useful for strata records, insurance and any future warranty conversation.
Repair or replace an older Laars boiler with recurring E45?
On its own, E45 is rarely a reason to replace a boiler. The parts most often involved are the sensing tube, connectors and wiring, condensate trap components, the air pressure sensor and, less often, the combustion blower. Tubing, cleaning and condensate work sit on the lighter end of the repair scale; a combustion blower is one of the more expensive parts on a sealed-combustion boiler. We do not quote figures over the phone because the right answer depends on what the meters show, so ask for a written quote once the cause is confirmed.
The repair-or-replace conversation becomes real when E45 is one symptom among several on an older unit. Here are the factors we put in writing for you, so the decision is yours and is made on facts:
- Heat exchanger condition: in Metro Vancouver our soft water means hydronic trouble is usually sludge and corrosion inside the loop, not limescale. A heat exchanger that is fouling or corroding changes the economics of any repair.
- Parts availability: on an older model, some control and blower parts may be harder to source. We will tell you if a part is likely to involve a long wait.
- Frequency of lockouts: a boiler that has needed several unrelated repairs in recent seasons is telling you something.
- Venting condition: if the venting itself needs to be rebuilt to current code, that work is required either way and should be weighed in the decision.
- Sizing: many older boilers were sized by rule of thumb. If replacement is on the table, a proper heat-loss calculation for your home comes first, not a like-for-like swap.
- Permits: a boiler replacement in BC needs a gas permit through Technical Safety BC and an inspection, and some municipalities add their own requirements. A licensed contractor pulls the permit; you should see that in the written quote.
Laars boiler error code E45 service across Greater Vancouver, and who does the work
We service boilers showing E45 across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Our mild, wet coastal climate shapes E45 in a particular way. Snow is occasional rather than routine, but autumn leaves, conifer needles, heavy rain and wind are constant, and those are exactly what interferes with side-wall vent terminals and condensate drains.
Housing stock varies across the region and changes what we expect to find. In Vancouver, Burnaby and New Westminster, many older homes have hydronic systems that were converted from an earlier boiler, and the newer high-efficiency unit may have been fitted into venting and drain arrangements that were never ideal. On the North Shore and in Coquitlam and the Tri-Cities, treed hillside lots tend to load terminals with needles and leaves, and higher elevations see more snow than the rest of the region. In Richmond and Delta, open, wind-exposed lots can push wind-driven rain toward terminals. In Surrey and Langley, newer homes often place the boiler in a garage or mechanical room with longer vent runs, where slope and support matter. These are general patterns, not rules, and we confirm what is actually on site at your home.
Strata homes add one more step: moving or changing a vent terminal on a townhouse or condo exterior usually needs strata approval as well as a gas permit, so we put that in writing early.
BC Wide is an independent contractor, not an authorized dealer or warranty centre for any manufacturer. Laars is one of the boiler brands we service, alongside IBC, Viessmann, Weil-McLain, Lochinvar, Navien, Rinnai, Bosch and Buderus. If your boiler is still under a manufacturer warranty, the claim goes through the manufacturer’s own process; our written diagnosis and readings help you make it.
- Licensed by Technical Safety BC: gas contractor licence LGA0090068 and Class B gas licence CGA0028029.
- Work done by our own licensed gas fitters, serving Metro Vancouver homeowners since 1999.
- Permits and inspections pulled where the work requires them, never skipped.
- A written quote before any work beyond diagnosis, and a written record of findings and readings after the visit.
- Same-day service where the schedule allows, with an honest answer when it does not.
More questions homeowners ask
What does Laars boiler error code E45 mean?
E45 means the boiler’s control reads the air pressure sensor (APS) circuit as open, so it cannot confirm that combustion air and venting are working and it will not light the burner. The page describes it as a soft lock, so the boiler may retry once the condition clears. Confirm the meaning against the manual for your unit, and call a licensed technician if it does not clear.
Can I reset Laars boiler error code E45?
Only if your owner manual describes a reset for this condition, and only once. If E45 comes back, stop resetting, because the sensor is usually reporting a real airflow problem such as a blocked terminal or backed-up condensate. Repeated resets can mask a venting fault that matters for carbon monoxide safety.
Is it safe to run my Laars boiler with E45 showing?
While E45 is showing, the boiler is in lockout and is not firing, so the safety system is doing its job. What is never safe is bypassing, jumpering or disconnecting the air pressure sensor to force the boiler to run. If you smell gas or a carbon monoxide alarm sounds, leave the house and call FortisBC or 911 from outside.
Why does my Laars boiler show E45 when it is windy or raining?
Weather-linked E45 usually points to the outdoor vent and intake terminals. Strong wind can disturb pressure at the terminals, and heavy rain, leaves or snow can restrict them, so the sensor sees airflow outside its expected range. A licensed technician can check terminal placement, clearances and whether a manufacturer-approved termination option suits your exposure.
Will replacing the air pressure sensor fix Laars boiler error code E45?
Sometimes, but only after the airflow path has been proven good. A sensor that reads open is often accurately reporting a blocked terminal, a condensate backup, a cracked sensing tube or a weak blower. Replacing the sensor first frequently leaves the real cause in place, and the code returns.
Who repairs Laars boiler error code E45 near me in Greater Vancouver?
BC Wide services Laars boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent Technical Safety BC licensed contractor, not a factory dealer, and we give a written quote before any work beyond diagnosis. Call (604) 473-9690; we offer same-day service where the schedule allows.
- Lennox furnace g61mpv error codes
- Lennox furnace error code 225
- Goodman furnace error codes 6 blinks
- Boiler error message f28
- Miller furnace error codes
- Kelvinator furnace error codes
- Lennox furnace error code 270
- Airquest furnace error codes
- Heil furnace error code 4
- John Wood Water Heater Error Codes & Troubleshooting in Greater Vancouver
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.