Lennox boiler error code 109 is a pre-circulation fault. The boiler could not establish proper water circulation during the pre-circulation phase before firing, so it will not light. Confirm that meaning against the manual for your unit. In practice you lose heat, and on a combi unit you lose hot water too. You can check power, the pressure gauge, open valves and air in the radiators. A pump, sludge or valve fault needs a licensed technician. Call BC Wide at (604) 473-9690.
If your Lennox boiler is showing 109 (Pre-circulation fault), here’s exactly what it means and what to do. This guide is part of our full Lennox boiler error code list.
Severity: Needs attention.
What 109 means on a Lennox boiler
The boiler could not establish proper water circulation during the pre-circulation phase before firing.
Common causes
- Air in the system
- Low water pressure
- Sluggish or failed pump
- Closed valves
What you can safely check first
- Check the pressure gauge and top up via the filling loop if you know how
- Bleed trapped air from radiators
- If it persists, the pump/circulation needs a technician
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
If the simple checks above don’t clear the code, have it diagnosed by a licensed technician. Repeated lockouts on a Lennox boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox boiler repair across Greater Vancouver
If a Lennox boiler showing 109 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox boiler codes
- Lennox boiler 10 — External probe / sensor cable fault
- Lennox boiler 12 — Water flow switch open
- Lennox boiler 13 — Water flow switch closed
- Lennox boiler 18 — Gas valve fault
- Lennox boiler 19 — Automatic water refill enabled
- Lennox boiler 20 — Max water refill reached / Central Heating Flow or Flue NTC fault
Frequently asked questions
Is 109 on a Lennox boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lennox boilers 7 days a week across Greater Vancouver.
How do I reset a Lennox boiler after 109?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox Boiler Error Code 109: what it means for your heat, hot water and safety
The meaning of the code is narrow: before the burner is allowed to light, the boiler runs a short check to prove that water is actually moving through the heat exchanger. If it cannot prove circulation, it refuses to fire and shows 109. Confirm that meaning against the manual for your unit, because control software and code lists can differ between generations of the same brand. The point of that check is protective. A boiler that fires with no water moving can overheat its heat exchanger in a very short time, and that kind of damage is far more expensive to put right than a circulation fault.
For you as the homeowner, the practical effect is simple. The house cools down because the radiators, baseboard convectors or in-floor loops stop getting hot water. If your Lennox is a combi boiler that also makes domestic hot water, the taps and showers may run cold as well. If it heats an indirect hot water tank, the tank will slowly lose temperature once the stored hot water is used up. A pre-circulation fault is not, by itself, a gas leak or a carbon monoxide event. It is a water-side problem. That said, any boiler that is locking out repeatedly deserves a proper diagnosis rather than repeated resets, because the cause can get worse and the resets hide the pattern a technician needs to see.
These are the things owners usually describe on the phone when this code is behind the call:
- The boiler display shows 109 and the burner never lights, even though the thermostat is calling for heat.
- Radiators are cold at the top and warm at the bottom, or some rooms heat and others stay cold.
- You hear gurgling, trickling or a rushing sound in the pipes, which usually points to trapped air.
- The pressure gauge on the boiler reads lower than it normally does, or lower than the range marked in the manual.
- The pump hums but the pipe next to it stays cool, or the pump is completely silent when it should be running.
- The fault started right after radiators were bled, a radiator was replaced, or someone drained part of the system.
- The code clears after a reset, the boiler runs for a while, then the same lockout comes back.
Lennox boiler error code 109 causes, most common first, with the owner-safe check for each
The list below is ordered by what we most often find behind a pre-circulation fault on hydronic boilers in Metro Vancouver homes. It is a general guide, not a diagnosis of your particular boiler. Every cause has an owner-safe check and a point where it stops being a homeowner job. Anything inside the cabinet, any wiring, and anything on the gas side is work for a licensed technician.
1. Low system water pressure. Hydronic systems lose a little pressure over time through tiny weeps at valves and fittings, and lose more after radiators are bled. Below the minimum the boiler expects, flow sensing becomes unreliable. 2. Air in the system. Air pockets collect at high points and in the pump itself, and an air-locked pump can spin without moving water. 3. A closed or partly closed valve. Isolation valves near the boiler, zone valves and radiator valves are sometimes closed during other work and never reopened. 4. A sluggish, seized or failed circulator pump. Pumps that sat idle all summer can stick when the heating season starts. 5. Sludge and debris. In our soft-water region the build-up is iron-oxide sludge from internal corrosion, not limescale, and it can clog strainers, filters and narrow passages in the heat exchanger. 6. A faulty flow-proving or pressure-sensing component, or a wiring or control fault, which only a technician can test with the right meters.
| Likely cause (most common first) | What the owner may safely check | When it becomes a licensed call |
|---|---|---|
| Low system water pressure | Read the boiler pressure gauge with the system cold and compare it with the range marked in the manual. Top up through the filling loop only if the manual explains it and you are confident doing it. | Pressure keeps dropping after a top-up, which points to a leak, a failing expansion tank or a relief valve that is passing water. |
| Air in the system | Bleed radiators using a radiator key, starting on the lowest floor, then recheck the pressure gauge because bleeding lowers it. | Gurgling continues, the pump stays air-locked, or air keeps returning, which can mean an air vent or air separator has failed. |
| Closed or partly closed valve | Look at the visible valves beside the boiler and on radiators to see whether any handle is obviously turned off compared with the others. | You are not sure which valves should be open, or a zone valve motor is not opening when the thermostat calls. |
| Sluggish or failed circulator pump | Listen near the pump while the boiler is trying to start. Do not open the pump, tap it with tools, or remove any cover. | The pump is silent, noisy or hot, or the pipe beside it stays cool. Pump testing and replacement involve electrical work and draining the system. |
| Sludge or debris restricting flow | Note whether radiators heat unevenly or water bled from a radiator looks dark. Do not open filters or strainers. | Restricted flow is confirmed. Cleaning, flushing and inhibitor treatment are technician work on a pressurised system. |
| Flow or pressure sensing component, wiring or control fault | Nothing beyond confirming power and recording what the display shows and when. | Always. Testing sensors, harnesses and the control board requires a licensed technician with the right meters. |
Can I reset a Lennox boiler showing code 109? The owner-safe checks, in order
Yes, once, and only if the owner manual for your unit describes a reset procedure. A single reset after you have done the basic checks below is reasonable. Repeated resetting is not. Each attempt runs the pump against whatever is blocking flow, and if the cause is a failing component, repeated cycling can finish it off. Write down when the code appeared, what the pressure gauge showed and what you checked, because that history saves real diagnostic time when the technician arrives.
Work through these checks in this order. None of them require opening a panel, and none of them involve the gas train, burner compartment or control wiring:
- Power and switch: confirm the boiler service switch is on and the breaker for the boiler has not tripped. If the breaker has tripped more than once, leave it off and call.
- Thermostat calling: set the thermostat a few degrees above room temperature and confirm it is actually calling for heat. On a zoned system, try the thermostat for the zone you know works best.
- Gas supply valve: confirm the manual gas shutoff on the line to the boiler is in the open position. Do not touch any other gas fitting.
- Pressure gauge: read it with the system cold and compare it with the range in the manual. Top up only through the filling loop and only if you know how.
- Radiator air: bleed radiators that are cold at the top, lowest floor first, then recheck pressure.
- Outside terminals: on a high-efficiency boiler, make sure the outdoor intake and exhaust terminals are clear of leaves, snow, nests or anything stored against the wall.
- Visible condensate drain: check that the condensate drain line you can see is not kinked, disconnected or frozen where it runs outdoors.
- One reset: if the manual allows it, reset once. If 109 returns, stop and book a licensed technician.
How our Lennox boiler error code 109 repair visit works, step by step
Every visit follows the same order, so you know what is happening and what you will be asked to approve. We aim for same-day where we can. When the schedule is full or a part has to be ordered, we tell you that honestly and give you the earliest realistic slot rather than promising an arrival window we cannot keep.
1. Phone triage. When you call (604) 473-9690 we ask what the display shows, what the pressure gauge reads, whether you have heat or hot water, and whether anyone smells gas or has a carbon monoxide alarm sounding. A gas smell or CO alarm changes the advice immediately: leave the house and call FortisBC or 911 from outside.
2. Arrival and history. The technician reads the fault history stored in the control where the boiler keeps one, and asks about recent work on the system, because a pre-circulation fault right after a renovation or radiator change is often air or a closed valve.
3. Water-side diagnosis. We check static system pressure against the manual, test the expansion tank charge, confirm the pressure relief valve is not passing water, and walk every isolation and zone valve. We confirm the pump is powered and actually moving water, using meters rather than guesswork, and check whether the strainer, filter or heat exchanger shows signs of sludge restriction.
4. Controls and sensing. If the water side checks out, we test the flow-proving or pressure-sensing component, the wiring harness and the control inputs with the right meters, so we are replacing a confirmed fault rather than swapping parts in sequence.
5. Written quote before any work beyond diagnosis. You get a plain-language explanation of what failed, what we recommend, and a written quote. Parts most often involved in a circulation fault, in general terms, are the circulator pump, an air vent or separator, the expansion tank, a zone valve or its motor, and the flow or pressure sensing component. Nothing is replaced until you approve it.
6. Repair and safety testing. After the repair we refill and purge air, restore correct pressure, then fire the boiler and test the safeties: proving circulation, high-limit behaviour, flame operation and venting. On any combustion appliance we also check the venting and combustion before we leave. If the system is full of sludge, we will explain what a flush and inhibitor treatment involves rather than leaving a new pump to clog.
7. Paperwork. You get a written record of what we found and what we did. Where the work requires a permit under BC rules, we take out the permit and arrange the inspection.
Repair or replace an older Lennox boiler that keeps showing code 109?
A pre-circulation fault on its own is rarely a reason to replace a boiler. Most of the causes are on the water side of the system, and a pump, air vent, expansion tank or valve can be replaced without touching the heat exchanger. On a boiler that is otherwise sound, fixing the circulation problem properly and cleaning the system is almost always the right first answer.
The conversation changes on an older unit when several things stack up. Repeated circulation lockouts after earlier repairs can mean the heat exchanger itself is restricted with sludge, and a restricted heat exchanger is one of the more expensive parts on a boiler. If that is combined with corrosion on the heat exchanger, parts that are becoming hard to source, previous repairs to the control board, or a venting arrangement that no longer meets current code, the cost of keeping it running may approach the cost of a planned replacement. A planned replacement also lets you correct the underlying cause, such as an undersized expansion tank, missing air separation or no dirt separator, so the new boiler does not inherit the same problem.
We will tell you honestly which side of that line your boiler is on, and we put the reasoning in writing. If repair makes sense, we repair it. If replacement makes sense, you get a written quote that includes permits, venting changes and any gas piping work, so there are no surprises. If you are planning a replacement anyway, it is also the right moment to talk about whether a heat pump paired with a gas boiler or furnace kept as backup for cold snaps suits your house, but that is a separate decision from fixing the fault in front of you.
Lennox boiler error code 109 service near you in Greater Vancouver, from an independent licensed contractor
BC Wide works on hydronic boilers across Greater Vancouver, including Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. The housing stock varies a lot across that area. Older detached homes in Vancouver, Burnaby and New Westminster often carry long-running hot water heating systems that have been modified several times, with a newer boiler connected to older radiators or piping, and those mixed systems are exactly where air, sludge and valve problems show up. Townhouses and strata buildings, common in Richmond, Coquitlam, the North Shore and parts of Surrey, can have tight mechanical closets, shared venting arrangements and strata rules about access and work hours, so we plan those visits around the building. Newer homes in Surrey, Langley and Delta more often have in-floor radiant loops, where a circulation fault can come from a zone valve, a manifold balancing issue or air trapped in a long loop.
Our water is soft across the region. That means hydronic problems here are mostly sludge and corrosion inside the system rather than limescale, which is why we pay attention to water condition and inhibitor treatment instead of assuming a pump alone is the fix. Our mild, wet coastal climate also means boilers run long, gentle cycles for much of the year, and a short cold snap is often when a weak pump or low pressure finally shows itself as a lockout.
On trust: BC Wide Home Services Ltd is an independent contractor licensed by Technical Safety BC, gas contractor licence LGA0090068, with Class B gas licence CGA0028029. Gas work is done by our own licensed gas fitters. We are not an authorised dealer or warranty centre for any manufacturer. We take out permits and arrange inspections where the work requires them, and you receive a written quote before any work beyond diagnosis.
Boiler and combi brands we service, alongside Lennox, include:
- Lennox
- IBC
- Navien
- Rinnai
- Bosch
- Noritz
- Rheem
- A. O. Smith
More questions homeowners ask
What does Lennox boiler error code 109 mean?
It is a pre-circulation fault: the boiler could not establish proper water circulation during the pre-circulation phase before firing, so it does not light. Confirm the meaning against the manual for your unit. The most common causes are low system pressure, trapped air, a closed valve, a weak pump or sludge restricting flow.
Can I reset a Lennox boiler with error code 109?
Once, and only if your owner manual describes a reset. Check power, the thermostat, the gas supply valve, the pressure gauge and radiator air first, then reset a single time. If 109 comes back, stop resetting and book a licensed technician, because repeated attempts can damage a struggling pump and hide the real fault.
Is it safe to run my Lennox boiler after a code 109 clears?
If the code cleared because you topped up low pressure or bled air and it stays clear, the boiler can usually run normally while you watch the pressure gauge for a few days. If the code returns, the pressure keeps falling, or you hear the pump struggling, have it inspected. If you ever smell gas or a carbon monoxide alarm sounds, leave the house and call FortisBC or 911 from outside.
Why does my Lennox boiler show 109 after I bled the radiators?
Bleeding radiators lets air out but also lowers system pressure, sometimes below what the boiler needs to prove circulation. Check the gauge with the system cold and compare it with the range in the manual. If topping up is not something you are comfortable doing, or pressure drops again, a technician should check the fill valve, expansion tank and air vents.
How quickly can you fix Lennox boiler error code 109 near me in Greater Vancouver?
We aim for same-day where we can across Vancouver, Burnaby, Surrey, Richmond, the Tri-Cities, the North Shore, New Westminster, Delta and Langley, but we never promise a guaranteed arrival window. Many circulation faults are fixed on the first visit, while a pump or part that has to be ordered can add time. Call (604) 473-9690 and we will give you the earliest realistic slot.
Do I need a licensed technician for a Lennox boiler code 109?
For anything beyond the owner checks, yes. Pump replacement, valve and expansion tank work, sensor and wiring tests, and anything on the gas side must be done by licensed trades in BC. BC Wide is an independent TSBC-licensed contractor, gas contractor licence LGA0090068, and you receive a written quote before any work beyond diagnosis.
- Lennox furnace g61mpv error codes
- Lennox furnace error code 225
- Goodman furnace error codes 6 blinks
- Boiler error message f28
- Miller furnace error codes
- Kelvinator furnace error codes
- Lennox furnace error code 270
- Airquest furnace error codes
- Heil furnace error code 4
- John Wood Water Heater Error Codes & Troubleshooting in Greater Vancouver
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.