Lennox boiler error code 117 means the control has detected system water pressure above its safe operating range (confirm against the manual for your unit). The boiler locks out to protect itself, so you can lose heat and, on a combi-style unit, hot water. Make sure the filling loop is fully closed, then read the gauge once the boiler has cooled. If the code comes back, the expansion vessel, fill valve or pressure sensor needs a licensed technician. Call BC Wide at (604) 473-9690.
If your Lennox boiler is showing 117 (System water pressure too high), here’s exactly what it means and what to do. This guide is part of our full Lennox boiler error code list.
Severity: Needs attention.
What 117 means on a Lennox boiler
The control has detected system water pressure above the safe operating range.
Common causes
- Overfilled system / filling loop left open
- Expansion vessel fault (waterlogged)
- Faulty pressure sensor
What you can safely check first
- Confirm the filling loop is fully closed
- If pressure is very high you may carefully bleed a radiator to release a little water if you know how
- If pressure climbs again, have the expansion vessel checked by a technician
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
If the simple checks above don’t clear the code, have it diagnosed by a licensed technician. Repeated lockouts on a Lennox boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox boiler repair across Greater Vancouver
If a Lennox boiler showing 117 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox boiler codes
- Lennox boiler 10 — External probe / sensor cable fault
- Lennox boiler 12 — Water flow switch open
- Lennox boiler 13 — Water flow switch closed
- Lennox boiler 18 — Gas valve fault
- Lennox boiler 19 — Automatic water refill enabled
- Lennox boiler 20 — Max water refill reached / Central Heating Flow or Flue NTC fault
Frequently asked questions
Is 117 on a Lennox boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lennox boilers 7 days a week across Greater Vancouver.
How do I reset a Lennox boiler after 117?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox boiler error code 117: what it means for your heat, hot water and safety
In plain terms, code 117 tells you the water inside your heating loop is under more pressure than the boiler is designed to run at. Work from the meaning the code list gives, system water pressure too high, and confirm it against the manual for your unit, because control software can differ between model generations. A sealed hydronic system is a closed loop of water that expands as it heats up. The boiler is designed to absorb that expansion through an expansion vessel and to protect itself with a pressure relief valve. When the control reads pressure above its limit, it stops firing instead of adding more heat to a loop that is already pushing against its safeties.
For you, that usually means the radiators, baseboard convectors or in-floor zones go lukewarm and then cold. If your boiler also makes domestic hot water, the taps can run cold too. The lockout is the safety system doing its job. The real risk is ignoring the cause. A loop that keeps over-pressurizing will eventually open the relief valve and push hot water out through the discharge pipe. Every time that valve opens it wears a little, so after a few discharges it can start to weep or fail to reseat. Constant high pressure also strains fittings, pump seals, air vents and older radiator valves, and a small weep at a joint can turn into a ceiling stain on the floor below.
This is a gas appliance, so the usual rule for combustion equipment applies. If you smell gas (a rotten-egg odour) or a carbon monoxide alarm goes off, do not reset anything and do not flip switches. Get everyone out of the house and call FortisBC or 911 once you are outside. Code 117 is a water-side fault, but a boiler that has been short-cycling, overheating or venting poorly needs a full combustion and venting check as well as the pressure repair.
Things owners usually notice before or along with code 117:
- The pressure gauge needle sits well above its usual resting point, especially when the boiler is hot
- Water drips or pools under the copper or plastic discharge pipe that runs from the relief valve toward the floor
- Radiators or floors that were warm an hour ago go cold after the boiler locks out
- The code clears after a reset and then comes back on the next heating cycle
- You hear a faint hiss or trickle near the boiler, or the filling loop handle is sitting slightly open
- Pressure creeps up a little every day even though nobody has touched the fill valve
- On a combi-style unit, pressure seems to jump after someone takes a long hot shower
Lennox boiler error code 117 causes, most common first, and when each becomes a licensed call
On sealed systems across Metro Vancouver, high-pressure lockouts tend to come from the same few causes, in roughly the same order. The list below starts with the most common. For each one it says what you can safely look at yourself and where it stops being a job for the owner. One rule covers all of them. If pressure keeps rising after the filling loop is confirmed closed, the cause is inside the system, and finding it takes isolation valves, drain points and test instruments that belong to a licensed technician.
1. Filling loop left open or not fully closed. Someone topped up the pressure and left the fill valve or braided filling loop slightly open, so mains water keeps pushing into the heating loop. Owner check: make sure both valves on the filling loop are fully closed. On many installations the loop is meant to be disconnected once filling is done. Licensed call: if pressure still climbs with the loop closed, the valve is passing water internally and has to be replaced.
2. Expansion vessel waterlogged or short on its air charge. The vessel has an air cushion on one side of a diaphragm. Over time that charge leaks away, or the diaphragm fails and the vessel fills with water, so there is nowhere for heated water to expand. Pressure then spikes on every heat cycle and falls back as the system cools. Owner check: only watch the gauge. Testing the charge means isolating and draining the water side of the vessel. Licensed call: always.
3. Automatic fill valve or pressure-reducing valve creeping. Many North American hydronic installations use an automatic fill valve instead of a manual filling loop. A worn seat or debris on the seat lets mains pressure creep into the loop slowly, often overnight. Owner check: none beyond noting whether the pressure rises when the boiler is idle and cold. Licensed call: always.
4. Faulty pressure sensor, wiring or connector. Sometimes the water pressure is fine and the control is reading it wrong. The clue is a mechanical gauge that sits in the normal band while the display reports high pressure. Owner check: compare the gauge with the code and write down what you see. Licensed call: always. Diagnosing this means working on live controls, and swapping parts blindly wastes money.
5. Internal leak between domestic water and heating water on combi-style units. On a boiler that also heats tap water, a failed plate heat exchanger or diverter seal can let higher-pressure mains water into the heating side. Owner check: notice whether pressure jumps right after hot water use. Licensed call: always, because the fix means opening the appliance.
6. Overheating or poor flow pushing pressure up. A stuck circulator, zone valves that will not open, a clogged strainer or a heat exchanger restricted by sludge lets water overheat locally, and hotter water expands more. In our soft-water region the restriction is usually black sludge and corrosion debris, not limescale. Owner check: confirm the thermostat is calling and note any banging or kettling noises. Licensed call: always.
| What you see | Most likely cause | What the owner can do | Needs a licensed technician |
|---|---|---|---|
| Pressure high and filling loop handle partly open | Filling loop left open | Close both valves fully and recheck the gauge when cold | Only if pressure still climbs after closing |
| Pressure spikes when hot and drops when cold | Expansion vessel waterlogged or under-charged | Note readings hot and cold, nothing more | Yes, vessel test and recharge or replacement |
| Pressure creeps up overnight with the boiler idle | Fill valve or reducing valve passing | Confirm the manual loop is closed | Yes, valve replacement |
| Gauge reads normal but code 117 shows | Pressure sensor, wiring or connector | Photograph the gauge and the display | Yes, sensor and control diagnosis |
| Pressure jumps after hot taps are used | Internal leak on a combi-style unit | Note the timing and avoid repeated resets | Yes, heat exchanger or seal repair |
| Relief valve pipe dripping or pooling | Repeated over-pressure opening the valve | Put a container under it, never cap or block the pipe | Yes, find the cause and test or replace the valve |
| Banging, kettling, rooms uneven, then code 117 | Flow restriction, sludge or a stuck pump | Confirm the thermostat is calling, then stop | Yes, flow testing and system cleaning |
Can I fix Lennox boiler code 117 myself? Owner-safe checks, in order
In BC, gas work is restricted to licensed gas fitters, and most electrical work inside the appliance belongs to licensed trades as well. Anything that means opening the boiler cabinet, draining part of the system or adjusting a valve on the hydronic piping should be treated as technician work. That still leaves a short list of checks you can do without tools. Each one either clears up a simple cause or gives the technician information that makes the visit faster.
Work through these in order and stop as soon as something looks wrong:
- Write down the code and take a clear photo of the pressure gauge and the display. That record is useful later.
- Let the boiler cool for a while, then read the gauge again. Pressure rises somewhat when the water is hot. The normal cold range is printed on the gauge face or given in the manual.
- Make sure the filling loop or manual fill valve is fully closed. Do not open it to experiment.
- Check that the power switch or service switch for the boiler is on and that the breaker has not tripped. Power does not cause a high-pressure code, but it rules out a second problem.
- Look at the gas supply valve without forcing it. The handle normally lines up with the pipe when it is open. If you are unsure, leave it alone.
- Make sure the thermostat is set to heat and is actually calling.
- Go outside and check the intake and exhaust terminals. Clear leaves, moss, nests or snow by hand, and do not push anything into the pipes.
- Look along the visible condensate drain line for kinks, a disconnected end or standing water, and note anything you find.
- Check the relief valve discharge pipe for drips. Never lift the test lever yourself, and never cap or plug the pipe.
- Reset the boiler once, and only if your owner manual allows it. If 117 comes back, stop resetting and call.
How our Lennox boiler error code 117 repair visit works, step by step
A high-pressure code is easy to clear for an afternoon and hard to fix properly unless the technician follows the evidence. This is how our licensed technicians handle a code 117 call, from the first phone conversation to the paperwork you keep.
BC Wide Home Services Ltd is an independent contractor licensed by Technical Safety BC (gas contractor licence LGA0090068, Class B gas licence CGA0028029) and has served Metro Vancouver since 1999. Our own licensed gas fitters do the work. We pull permits and arrange inspections when a job needs them, such as a boiler replacement, gas piping changes or venting changes. You get a written quote before any work beyond diagnosis. Lennox is one of the boiler brands we service. Others include Navien, Rinnai, Bosch, Noritz and A. O. Smith. We are not a factory-authorized dealer or warranty centre for any of them, so if your boiler may still be under the manufacturer warranty, check those terms before repairs start. We will document what we find either way.
- Step 1, the phone call: you call (604) 473-9690 and we ask for the code, the gauge reading, whether the relief pipe is dripping, and whether you have lost heat, hot water or both. We tell you which owner-safe checks to try and book the visit. Same-day where we can. On a cold night with a full schedule that is not always possible, and we will say so honestly.
- Step 2, safety first on arrival: the technician checks the gas connections at the appliance for leaks, checks for carbon monoxide in the mechanical room, and looks over the venting before touching the hydronic side.
- Step 3, history and meaning: we read the fault history the control has stored and confirm what 117 means on your model against the manufacturer documentation, instead of working from memory.
- Step 4, measuring: we check the system pressure with a calibrated test gauge and compare it with the boiler gauge and sensor reading. With the vessel isolated and its water side drained, we test the expansion vessel air charge. We check whether the fill valve passes water when closed, and on combi-style units we isolate the domestic side to test for an internal leak.
- Step 5, flow and water condition: we check circulator operation, zone valves, the strainer or dirt separator and air removal, and we look at a water sample. Dark, gritty water points to sludge that needs to be dealt with as well as the pressure fault.
- Step 6, written findings and quote: you see what we measured, what we think the cause is, and a written quote before we go beyond diagnosis. If more than one fix is reasonable, we explain each one.
- Step 7, the repair: the parts most often involved are the expansion vessel, the fill valve or filling loop, the pressure sensor, the relief valve and, on combi-style units, the plate heat exchanger or diverter components. A control board is one of the more expensive parts, so we confirm it is actually at fault before quoting it.
- Step 8, recommissioning: we refill the system to the correct cold pressure, purge the air, check that the relief valve operates and reseats, run the boiler through a full heat cycle, test the safeties and do a combustion check.
- Step 9, paperwork: you get a written record of what was found, what was replaced and what we recommend watching, plus permit documentation where the work required a permit.
Repair or replace an older Lennox boiler that keeps showing code 117?
Code 117 alone is almost never a reason to replace a boiler. The usual causes are an expansion vessel, a fill valve or a sensor, and those are ordinary repairs on an appliance that is otherwise sound. Replacement becomes a fair question when the high-pressure fault is a symptom of something larger, or when it shows up alongside other signs that the boiler is near the end of its working life.
On an older unit, these are the things that tip the decision. We look at them on site and put them in writing, so you are not deciding from a guess:
- Heat exchanger condition: on a combi-style unit, an internal leak between the domestic and heating sides can mean a costly repair on an ageing appliance, and that changes the decision.
- Parts availability: some older control and sensor parts become hard to source, and long waits for parts in January matter.
- Repeat failures: one expansion vessel in many years is normal wear. Several unrelated faults in a couple of seasons usually means more are coming.
- Sludge damage: years of untreated water in a mixed-metal system can leave the heat exchanger restricted, and cleaning helps only up to a point.
- Combustion and venting results: if the combustion check or the venting no longer meets current requirements, a repair may still leave a compliance problem.
- Your plans for the house: a boiler you expect to rely on for many more winters justifies a different decision than one in a house you are about to sell.
Lennox boiler error code 117 service in Greater Vancouver: what we see across the region
Metro Vancouver water is soft, and that shapes how hydronic systems age here. We rarely deal with hard-water limescale inside heating loops. What we see is sludge, magnetite and corrosion debris, especially in older systems that mix steel, cast iron and copper or that have been topped up with fresh water many times over the years. That debris can foul fill valves, settle in expansion vessels and restrict heat exchangers, and all of those are routes to a high-pressure lockout. Our mild, wet climate means the outside terminals are more likely to be blocked by leaves, moss and nests than by snow, although a cold snap can still bring snow and ice, particularly at higher elevations.
We cover Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock varies across the region, so the details below are general patterns, not rules for any particular street. In Vancouver and Burnaby, many older detached homes have hydronic systems that started with cast-iron radiators and later got a modern boiler, which mixes old piping with new equipment. New Westminster has a share of older homes with similar retrofits. Richmond, Surrey, Delta and Langley tend to have newer construction, including in-floor radiant systems where zone valves and mixing controls add more places for flow problems. Coquitlam, Port Coquitlam and Port Moody cover everything from older houses to new townhome and strata projects. On the North Shore, hillside homes and colder spells put more load on heating systems, and terminals are often harder to reach.
Strata buildings add their own steps. Mechanical closets can be tight, relief valve discharge often has to go to a specific drain, and access, parking and work hours may need to be booked with the strata manager in advance. Tell us when you call so we can plan for it. Wherever you are in the region, we will offer same-day service where we can and give you an honest window when we cannot.
More questions homeowners ask
What does Lennox boiler error code 117 mean?
It means the boiler control has detected system water pressure above its safe operating range. Confirm it against the manual for your unit. The boiler locks out to protect itself, and the usual causes are a filling loop left open, a waterlogged expansion vessel, a passing fill valve or a faulty pressure sensor.
Can I reset Lennox boiler code 117?
Reset it once, and only if your owner manual allows it, after you have checked that the filling loop is fully closed. If the code comes back, stop resetting, because repeated resets hide the cause and wear the relief valve. Call a licensed technician to find out why the pressure is climbing.
Is it safe to run my Lennox boiler with high water pressure?
No. Do not try to keep it running by working around the lockout. High pressure strains fittings and seals, and it can repeatedly open the relief valve and dump hot water. If you smell gas or a carbon monoxide alarm sounds, leave the house and call FortisBC or 911 once you are outside.
Why does my boiler pressure keep going up on its own?
Pressure that climbs while the boiler sits idle usually means mains water is getting in through a fill valve or filling loop that is not sealing. Pressure that spikes only when the boiler is hot usually points to a waterlogged expansion vessel. On combi-style units, an internal leak from the domestic side is another possibility, and a technician can tell these apart with isolation tests.
Why is water dripping from the pipe next to my boiler?
That pipe is usually the relief valve discharge, and drips mean the valve has opened because of high pressure or is no longer sealing after repeated openings. Put a container under it and never cap or block it. The pressure cause needs fixing and the valve needs testing by a licensed technician.
Do you repair Lennox boiler error code 117 near me in Greater Vancouver?
Yes. BC Wide services Lennox boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor, not a dealer, and we give you a written quote before any work beyond diagnosis. Call (604) 473-9690. We offer same-day service where we can.
- Lennox furnace g61mpv error codes
- Lennox furnace error code 225
- Goodman furnace error codes 6 blinks
- Boiler error message f28
- Miller furnace error codes
- Kelvinator furnace error codes
- Lennox furnace error code 270
- Airquest furnace error codes
- Heil furnace error code 4
- John Wood Water Heater Error Codes & Troubleshooting in Greater Vancouver
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.