Lennox boiler error code 118 means system water pressure has dropped below the minimum the boiler needs, so it will not fire (confirm against the manual for your unit). Check the pressure gauge, look for drips at the boiler, radiators and relief valve pipe, and top up only if your owner manual shows how. If pressure drops again within days, there is a leak or a failed component that a licensed technician needs to find. Call BC Wide at (604) 473-9690.
If your Lennox boiler is showing 118 (System water pressure too low), here’s exactly what it means and what to do. This guide is part of our full Lennox boiler error code list.
Severity: Needs attention.
What 118 means on a Lennox boiler
System water pressure has dropped below the minimum needed to operate, so the boiler will not fire.
Common causes
- Gradual pressure loss over time
- A leak in the system
- Recent radiator bleeding
- Faulty pressure sensor
What you can safely check first
- Top up the system to about 1.0-1.5 bar using the filling loop if you know how, then reset
- Look for visible leaks around the boiler and radiators
- If pressure keeps dropping there is a leak – call a technician
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
If the simple checks above don’t clear the code, have it diagnosed by a licensed technician. Repeated lockouts on a Lennox boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox boiler repair across Greater Vancouver
If a Lennox boiler showing 118 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox boiler codes
- Lennox boiler 10 — External probe / sensor cable fault
- Lennox boiler 12 — Water flow switch open
- Lennox boiler 13 — Water flow switch closed
- Lennox boiler 18 — Gas valve fault
- Lennox boiler 19 — Automatic water refill enabled
- Lennox boiler 20 — Max water refill reached / Central Heating Flow or Flue NTC fault
Frequently asked questions
Is 118 on a Lennox boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lennox boilers 7 days a week across Greater Vancouver.
How do I reset a Lennox boiler after 118?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox boiler error code 118: what we check first
When we arrive at a Lennox boiler showing 118, the first question is not how to clear the code but where the water went. A sealed hydronic system is a closed loop. It should hold its pressure for months at a time with very little change. If the gauge has fallen far enough to trigger the low-pressure lockout, water has either left the loop or the boiler is reading the pressure wrongly. Everything we do on site is aimed at telling those two apart, because topping up a system that is actively losing water only buys time.
Below are the likely causes in the order we most often find them on Greater Vancouver homes, what an owner can safely look at for each, and the point where it becomes a job for a licensed technician. Confirm the code meaning against the manual for your unit before acting on any of it.
- 1. A slow leak at a fitting, valve or radiator. Owner check: look and feel for damp spots, white or green crusting, or rust streaks at radiator valves, under the boiler and along exposed pipe. Licensed call: any leak at or inside the boiler cabinet, or any leak you cannot reach.
- 2. The pressure relief valve discharging. Owner check: look at the end of the relief valve drain pipe, often near the floor beside the boiler, for water or a wet patch. Licensed call: always. A relief valve that opens repeatedly is reacting to pressure swings, usually from an expansion tank that has lost its air charge, and both parts need testing.
- 3. Air recently removed from the system. Owner check: think back. If radiators were bled, a radiator was changed, or other work was done on the heating loop, pressure loss after that is expected and a single top-up may be all it needs. Licensed call: if the code returns after one correct top-up.
- 4. A leaking automatic air vent. Owner check: look for drips or staining around the small vent fittings on top of the boiler piping. Licensed call: replacing or servicing the vent.
- 5. An automatic fill valve that is closed, clogged or failed. Owner check: none beyond confirming nobody has turned the main water supply to the boiler off. Licensed call: testing and adjusting the fill and pressure-reducing valve.
- 6. A faulty pressure sensor or its wiring. Owner check: compare the boiler display reading with the mechanical gauge if your boiler has both. If they disagree, note it for the technician. Licensed call: always. Sensor and wiring checks are electrical diagnostic work inside the cabinet.
- 7. A hidden leak inside a wall, under a slab in a radiant floor, or inside the boiler heat exchanger. Owner check: none that is reliable. Licensed call: pressure-loss testing, isolating zones one at a time, and inspection of the heat exchanger.
| What you notice | Most likely cause | Safe owner step | Who fixes it |
|---|---|---|---|
| Code 118 after radiators were bled | Air removed, water not replaced | Top up once if your manual shows how | Owner, then a technician if it returns |
| Water at the end of the relief valve pipe | Relief valve opening, often from a flat expansion tank | Note it and do not cap or block the pipe | Licensed technician |
| Damp or crusted fittings at radiators | Slow leak at a valve or joint | Put a tray under it and photograph it | Licensed technician |
| Pressure gauge climbs high when hot, then drops | Expansion tank charge lost | Record the cold and hot readings | Licensed technician |
| Code returns within days with no visible leak | Hidden leak, fill valve or sensor fault | Stop topping up and book a diagnosis | Licensed technician |
| Display and gauge disagree | Pressure sensor or wiring fault | Note both readings | Licensed technician |
What does Lennox boiler code 118 mean for your heat, hot water and safety?
In owner terms, code 118 means the boiler has stopped heating on purpose. Low water pressure is the boiler’s signal that there may not be enough water moving through the heat exchanger, and firing a burner into a dry or starved heat exchanger can overheat and damage it. The lockout is protecting the equipment. It is not, by itself, a gas leak or a carbon monoxide warning.
What you will notice depends on how your system is set up. With a heating-only boiler, radiators and in-floor zones go cold while a separate water heater keeps supplying hot taps. With a combi boiler that also makes domestic hot water, you may lose both heat and hot water at the same time. Some homes with an indirect hot water tank heated by the boiler will also lose hot water once the tank cools down.
The symptoms owners usually describe to us before the code appears are worth knowing, because catching them early often means a smaller repair:
- The needle on the boiler pressure gauge sits lower each week than it did the week before.
- Radiators are warm at the bottom and cold at the top, or gurgle when the heat comes on.
- You have had to top the system up more than once in a season.
- There is a small puddle or a dried water mark near the boiler that keeps coming back.
- The boiler fires, runs briefly and then locks out again after a reset.
- Upstairs radiators heat poorly while downstairs ones are fine.
How our Lennox boiler error code 118 repair visit works
A low-pressure fault is a diagnosis job first and a parts job second. This is how a BC Wide visit runs, from the phone call to the written quote, so you know what to expect and what you should see in writing.
- Step 1, the call. We ask for the code, the gauge reading if you can see it, whether you have topped up, and whether you have heat or hot water. We book same-day where we can, and we tell you honestly when we cannot. We never promise a fixed arrival window we are not sure of.
- Step 2, safety first on arrival. The technician checks for gas odour and confirms the venting and combustion air path are clear before anything else, because a boiler that has been reset repeatedly may have other faults hiding behind the pressure code.
- Step 3, reading the pressure properly. We compare the boiler’s own sensor reading with a calibrated test gauge, cold and then at operating temperature. A reading that swings widely between cold and hot points us toward the expansion tank. A reading that disagrees with the test gauge points us toward the sensor or its wiring.
- Step 4, finding where the water goes. We inspect the relief valve discharge, air vents, fill valve, pump flanges, zone valves and radiator connections, then isolate the system zone by zone if needed to see which section loses pressure.
- Step 5, checking the parts most often involved. In general terms these are the expansion tank and its air charge, the pressure relief valve, automatic air vents, the fill and pressure-reducing valve, the pressure sensor, and occasionally a pump seal or a heat exchanger leak. We test before we replace anything.
- Step 6, testing the safeties. Once the cause is known, we confirm the low-pressure cut-out, high-limit and other safety controls respond the way the manufacturer intends, and that the boiler fires and burns cleanly.
- Step 7, a written quote before any work beyond diagnosis. You get the finding, the recommended repair and any options in writing. Nothing beyond the diagnosis is done until you approve it.
- Step 8, refill, purge and confirm. After a repair the system is refilled to the pressure the manufacturer and installer label call for, air is purged, and the pressure is rechecked hot and cold before we leave.
Should you repair or replace an older Lennox boiler that keeps losing pressure?
Most code 118 calls end in a repair, not a replacement. An expansion tank, relief valve, air vent or fill valve is a routine part, and replacing it on a sound boiler is the right answer. A pressure sensor is also normally a straightforward repair once it is confirmed faulty.
The conversation changes when the water is leaving through the boiler itself. A heat exchanger leak is one of the more expensive repairs on a gas boiler, and on an older unit it is often the point where replacement deserves a serious look. We weigh the condition of the heat exchanger and the rest of the boiler, whether the parts are still readily available for your model, how many repairs the boiler has needed recently, and whether the venting and gas supply would also need work for a new unit.
We give you both options in writing when replacement is genuinely on the table, and we do not push one. If a replacement makes sense, the new boiler is sized from a heat-loss assessment of your home rather than matched to the old nameplate, and the system is cleaned and treated so the new boiler does not inherit the old sludge. Ask for a written quote on both paths and compare them side by side.
Lennox boiler error code 118 service near you in Greater Vancouver
BC Wide services hydronic boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley, from our base in Burnaby. Housing stock varies a lot across that area, and it shapes how a low-pressure fault usually turns out.
Older detached homes in Vancouver, Burnaby, New Westminster and parts of the North Shore often have hydronic systems that have been extended or partly replaced over the decades, with a mix of older cast iron radiators and newer piping. More joints and older valves generally mean more places for a slow weep. Newer homes and townhouses in Surrey, Langley, Coquitlam and Richmond are more likely to have in-floor radiant zones, where a leak can sit out of sight under a floor finish. Strata buildings across the region add another layer: in-suite boilers and combi units sit in tight closets, and any work that changes venting or gas piping may need strata approval as well as a permit.
Metro Vancouver water is soft. That is good news for scale, but soft water in a hydronic loop that has been topped up many times brings in fresh oxygen, which feeds corrosion. The result we see most often here is sludge and magnetite debris, not limescale. That sludge can foul pressure sensors and valves, wear pump seals, and make relief valves seat poorly, all of which can end in a 118 lockout. Where we find it, we recommend cleaning the system and adding a dirt and magnetite separator rather than just replacing the part that failed.
Brands of hydronic boilers we service include Lennox, Viessmann, IBC, Lochinvar, Weil-McLain, Navien, Bosch and Rinnai. We are an independent contractor and service these brands; we are not a factory-authorised dealer or warranty centre for any of them, so check your warranty documents before work if your boiler is still covered.
Why choose a TSBC-licensed independent contractor for a boiler pressure fault?
Gas boiler work in British Columbia is regulated. BC Wide Home Services Ltd holds Technical Safety BC gas contractor licence LGA0090068 and our gas fitters work under Class B gas licence CGA0028029. The technicians who diagnose your boiler are our own licensed staff. Where the work requires a permit, such as a boiler replacement or changes to gas piping or venting, we pull it with the authority having jurisdiction and the work is open to inspection.
What you should always receive from us: a clear explanation of what caused the code, a written quote before any work beyond diagnosis, the permit where one applies, and a final pressure and safety check recorded at the end of the visit.
A safety note that applies to every gas boiler call. Code 118 is a water pressure fault, but a boiler that has been reset again and again, or that has had panels removed, can hide other problems. If you smell gas at any time, leave the home immediately, do not operate switches or phones inside, and call FortisBC or 911 from outside. If a carbon monoxide alarm sounds, get everyone out and call 911 from outside. Every home with a gas boiler should have working CO alarms near sleeping areas. Homeowners may check the gauge, look for leaks, confirm power and the thermostat, check that the outside vent terminals are clear of leaves, snow or nests, and top up only if the manual describes it. Opening the burner compartment, the gas valve or the control wiring is licensed work. For a Lennox boiler showing 118 anywhere in Greater Vancouver, call BC Wide at (604) 473-9690.
More questions homeowners ask
What does Lennox boiler error code 118 mean?
It means the system water pressure has dropped below the minimum the boiler needs to run, so it will not fire. Confirm the meaning against the manual for your unit. The boiler is protecting its heat exchanger, and the real question is where the water went.
Can I reset a Lennox boiler showing code 118?
Only after the pressure has been brought back up, and only once, if your owner manual allows a reset. Resetting with low pressure will simply lock out again. If the code returns after one correct top-up and reset, stop and book a licensed technician rather than resetting repeatedly.
Is it safe to run my boiler if I keep topping up the pressure?
It is not a good long-term plan. Frequent top-ups mean water is leaving the system, and every fill brings in fresh oxygen that speeds up internal corrosion and sludge, especially in Metro Vancouver’s soft water. Have the leak or failed part found before it damages the boiler.
Why does my Lennox boiler keep losing pressure with no visible leak?
The most common hidden causes are a relief valve discharging down its drain pipe, an expansion tank that has lost its air charge, a leaking air vent, a leak inside a wall or radiant floor, or a fault inside the boiler. A technician isolates zones and tests each part to find which one it is.
Who repairs Lennox boiler error code 118 near me in Greater Vancouver?
BC Wide services Lennox and other gas boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor and book same-day where we can. Call (604) 473-9690.
Will code 118 damage my boiler if I ignore it?
The lockout itself protects the boiler, so the immediate risk is a cold house rather than damage. The underlying cause is the concern: an ongoing leak can damage floors and walls, and a system that keeps losing water corrodes faster inside. Getting it diagnosed early usually keeps the repair smaller.
- Lennox furnace g61mpv error codes
- Lennox furnace error code 225
- Goodman furnace error codes 6 blinks
- Boiler error message f28
- Miller furnace error codes
- Kelvinator furnace error codes
- Lennox furnace error code 270
- Airquest furnace error codes
- Heil furnace error code 4
- John Wood Water Heater Error Codes & Troubleshooting in Greater Vancouver
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.