★ 4.7 Google rating · Serving Greater Vancouver since 1999
ServicesBrandsRebates ReviewsAboutContact 📞 Call (604) 473-9690

Lennox Boiler Code 128 — Flame failure (no flame / ignition lockout) | BC Wide

Boilers, Error Codes, Hvac

Lennox Boiler Code 128 — Flame failure (no flame / ignition lockout) | BC Wide — BC Wide Heating & Air Conditioning, Greater Vancouver
Home › Lennox Boiler Code 128 — Flame failure (no flame / ignition lockout) | BC Wide

Lennox Boiler Code 128 — Flame failure (no flame / ignition lockout) | BC Wide

Quick answer

Lennox boiler error code 128 is a flame failure lockout. The boiler tried to light, could not detect a flame or lost it, and shut itself down for safety. That usually means no heat and, on a combi or a boiler that heats your hot water tank, no hot water either. Confirm the meaning against the manual for your unit. Check the power, the gas valve and the thermostat, and reset once only if your manual allows it. If 128 comes back, stop and call a licensed gas technician at (604) 473-9690.

If your Lennox boiler is showing 128 (Flame failure (no flame / ignition lockout)), here’s exactly what it means and what to do. This guide is part of our full Lennox boiler error code list.

Severity: Critical — likely no heat / lockout.

What 128 means on a Lennox boiler

The boiler failed to detect a flame, or lost the flame, and has locked out. This is a primary ignition/no-flame lockout.

Common causes

  • No gas supply or gas isolation valve closed
  • Ignition electrode or flame sensor fault
  • Gas valve fault
  • Air in the gas line
  • Condensate blockage tripping combustion

What you can safely check first

  1. Check that other gas appliances work and the boiler gas valve is open
  2. Confirm the boiler has power
  3. Attempt one reset by holding the Reset button 1-3 seconds
  4. If it locks out again, stop and call a licensed gas technician

Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.

When to call a technician

This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.

BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.

Lennox boiler repair across Greater Vancouver

If a Lennox boiler showing 128 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.

Related Lennox boiler codes

Frequently asked questions

Is 128 on a Lennox boiler serious?

It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs Lennox boilers 7 days a week across Greater Vancouver.

How do I reset a Lennox boiler after 128?

You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.

Lennox Boiler Error Code 128: what it means for your heat, hot water and safety

Put simply, code 128 means the boiler went through its lighting sequence and the control board never got proof of a flame, or it had a flame and then lost it. The control will not keep sending gas into a combustion chamber that is not burning it, so it closes the gas valve and locks out. The lockout is the boiler protecting you. The real fault is whatever stopped the flame from lighting or from being sensed. Display formats differ between control generations, so confirm the exact wording of the code against the manual for your unit.

For your heat, the radiators, baseboard convectors or in-floor loops stop getting hot water and cool down over the next few hours. A concrete slab with in-floor tubing holds heat for a long time, so many owners only notice the next morning when the house feels cold. For your hot water, it depends on how the system is set up. A combi boiler makes hot water directly, so the taps go cold right away. A boiler that heats an indirect storage tank leaves you with whatever hot water is already in the tank, and that runs out over the day. A standalone gas water heater is not affected by a boiler lockout.

For your safety, a boiler sitting in lockout is not dangerous in itself. The gas valve is closed and nothing is burning. The risk comes from what people do next: resetting it over and over, switching the power off and on to clear the code, or taking off covers to look inside. Every forced restart sends another charge of gas toward the burner, and if a vent or the combustion seal is the cause, every restart puts more combustion products where they should not be.

Here is what owners usually tell us on the phone before they find the code on the display:

  • The radiators are lukewarm or cold even though the thermostat is calling for heat.
  • The boiler clicks, the fan starts, we hear the igniter ticking, and then it goes quiet.
  • It lit for a moment, then went out, and the code came up.
  • The shower went cold halfway through (combi boilers and indirect tanks).
  • A reset fixed it yesterday, and now the same code is back.
  • It only seems to happen on windy, very wet or very cold nights.
  • There is water on the floor near the boiler, or the condensate tube looks full.
  • We heard gurgling from the boiler just before it locked out.
  • Someone did gas work in the house recently, like a new range, a fireplace or a meter change.

Lennox boiler code 128 likely causes, most common first, with the checks you can safely do

The order below is what we tend to find on condensing gas boilers in Metro Vancouver homes, from most common to least common. Your boiler may be different, and more than one cause can show up at once. A fouled flame sensor and a sluggish condensate drain often turn up together on a boiler that has not been serviced for a while. The owner-safe checks are the only steps a homeowner should take. Anything that means opening the cabinet, the burner compartment, the gas train or the control wiring is licensed work in BC.

If you smell gas at any point, or a carbon monoxide alarm goes off, do not try any of these checks. Leave the house right away and leave the door open behind you. Do not touch light switches, the thermostat, the boiler reset or anything else electrical. Once you are outside and well clear, call FortisBC or 911. Have everyone checked if anyone has a headache, nausea or dizziness. Every home with a gas boiler should have working carbon monoxide alarms near the sleeping areas and on each level.

Likely cause (most common first)What you might noticeOwner-safe checkWhen it becomes a licensed call
1. Gas supply interrupted or the boiler gas valve left closedCode shows up after renovation work, a meter change or another trade working nearby. The gas range or fireplace may not light either.See whether other gas appliances light. Make sure the handle on the boiler gas shut-off valve is in line with the pipe (open).If the valve is open and other appliances work, or if any appliance will not stay lit. Never loosen fittings or bleed gas lines yourself.
2. Flame sensor or ignition electrode dirty, worn or out of positionClicking and ticking, then nothing, or a flame that lights and drops out within moments.None beyond confirming power and gas. Do not open the burner compartment.Always. Measuring the flame signal and setting the electrode gap needs meters and a licensed technician.
3. Blocked condensate drain or trapGurgling, water near the boiler, or the code coming up after a long heating run.Look at the condensate tubing you can see outside the cabinet for kinks, a pulled-off end, or an outdoor section that has frozen. Check that a condensate pump, if you have one, is plugged in.If there is water inside the cabinet, the trap is full, or the code comes back after the visible line is clear.
4. Air intake or exhaust terminal blockedLockouts on windy or wet nights, after a snowfall, or in fall when leaves are coming down.From outside, look at the vent terminal on the wall. If you can reach it safely from the ground, clear leaves, snow or debris by hand.If the terminal is on the roof or damaged, pipes look disconnected, you see a nest inside, or there is scorching or heavy staining.
5. Air in the gas line after recent gas workCode right after a new gas appliance went in or the meter was replaced.One reset if your manual allows it. Nothing more.If it locks out again. Purging a gas line is licensed gas work.
6. Low gas pressure when other appliances are runningLockouts that happen when the dryer, range, fireplace or water heater is also running.Make a note of which appliances were on when the code showed up. That note helps the diagnosis.Always. Checking supply pressure and pipe sizing needs a licensed gas fitter with a manometer.
7. Poor ground or a loose connection in the flame-sensing circuitLockouts that come and go with no pattern.Check that the breaker or service switch for the boiler is on and has not tripped.Always. Do not open the control wiring or the junction boxes.
8. Gas valve or control board faultRepeated code 128 when everything above checks out.None.Always. Valve and board diagnosis is done with the power on and the gas live, so it is strictly licensed work.

How our Lennox boiler error code 128 repair visit works

A flame failure lockout gets diagnosed by testing, not by guessing. Replacing parts one by one until the code stops is the slowest and most expensive way to fix a boiler, and it often leaves the real cause in place. This is how one of our licensed gas technicians handles a code 128 call, step by step.

On parts, the ones most often involved in a flame failure are the flame sensor, the ignition electrode and its cable, the condensate trap and drain parts, the gas valve, and the control board. Sensors and electrodes are usually simple swaps. A control board or gas valve is one of the more expensive parts on a gas boiler. That is exactly why we measure before recommending one, and why your quote names the part and the reason for it.

On timing, we do same-day visits where we can, and a no-heat call with no hot water goes near the front of the line. We will not promise you a guaranteed arrival window. When the schedule is full we tell you so, and we tell you what you can safely do in the meantime.

  • Step 1, the phone call: we ask what the display shows, whether any gas work was done recently, whether your other gas appliances work, and whether you can smell gas. If you can, we send you to FortisBC first.
  • Step 2, on arrival: we confirm the code on the display, read the stored fault history if the control keeps one, and ask how often it has been locking out and in what weather.
  • Step 3, venting and condensate: we check the intake and exhaust from end to end, the terminal outside, the joints we can reach, the condensate trap and the drain path, and look for any sign of flue gas escaping.
  • Step 4, gas supply: we measure inlet gas pressure with a manometer, with the boiler off and again while it fires, and with other gas appliances running if the history points that way. We leak-test the connections we have touched.
  • Step 5, ignition and flame proof: we watch a full lighting sequence, measure the flame signal with a meter, and check the sensor, electrode condition, electrode gap, ignition cable and ground.
  • Step 6, combustion: once the boiler is firing steadily, we run a combustion analysis and compare the readings with the manufacturer-published targets for your model.
  • Step 7, safeties: we test the safety devices the boiler relies on, such as the air pressure switch, the high-limit control, the condensate safety and the low-water protection where fitted, so we know none of them is being masked.
  • Step 8, written quote: if the fix goes beyond the diagnosis, you get a written quote that names the cause, the part or work, and anything else we found, before any of that work starts. You decide.
  • Step 9, after the repair: we run the boiler through several heating cycles, and a hot water demand if it is a combi, confirm the code does not return, and show you what failed and why.

Should you repair or replace a Lennox boiler that keeps showing code 128?

Most code 128 calls end in a repair, not a replacement. A dirty flame sensor, a blocked condensate trap or a vent terminal full of leaves does not mean the boiler has reached the end of its life. The question changes when the boiler is older, the same lockout keeps coming back after proper repairs, or the diagnosis finds damage in a part that is costly to replace on an ageing appliance.

We give you the facts and leave the decision to you. When replacement does come up, it is not a like-for-like swap. A new boiler should be sized from a heat loss calculation for your home, not from the rating plate on the old one. Venting has to meet current code and the manufacturer instructions, the gas line has to be checked for the new load, and the job is done under a gas permit through Technical Safety BC. We service a wide range of boiler brands, including Lennox, Navien, IBC, Viessmann, Lochinvar, Bosch, Rinnai and Weil-McLain. We are an independent contractor, not a dealer for any of them, so we can talk about every option on its merits.

  • Repair usually makes sense when: the boiler is in good shape overall, the cause is clearly identified and fixed, parts are available, and the heat exchanger and venting check out.
  • Repair usually makes sense when: the lockout traces back to maintenance, such as a fouled sensor, a full trap or a blocked terminal, which a regular service schedule prevents.
  • Replacement deserves a conversation when: the boiler is well into its service life and needs a costly part such as a control board or gas valve on top of other worn components.
  • Replacement deserves a conversation when: the heat exchanger shows corrosion, leaks or heavy sludge damage, which on a condensing boiler often points to a system-water problem as well.
  • Replacement deserves a conversation when: the boiler is badly oversized and short-cycles, which wears ignition parts faster and makes lockouts more likely.
  • Replacement deserves a conversation when: replacement parts for your model are hard to source and every repair means a long wait in winter.
  • Either way: ask for the reasoning in writing, including what the technician measured, so you can compare options calmly instead of deciding in a cold house.

Lennox boiler error code 128 service in Greater Vancouver: what local homes add to the picture

Our mild, wet coastal climate shapes how flame failure lockouts happen here. Wind-driven rain and heavy fall leaf drop are a common source of trouble at sidewall vent terminals, especially low ones on the windward side of a house. Our cold snaps are short, but when they come, snow can drift over a terminal near the ground and an outdoor condensate line can freeze, and both can stop a condensing boiler from lighting. If code 128 shows up during a cold spell, look at the terminal and the outdoor condensate run first, from the ground only.

Metro Vancouver water is soft, so hydronic systems here do not tend to build up limescale. What we do see in older loops is sludge and corrosion: magnetite and debris carried round the system that strain circulators and foul the heat exchanger. That does not cause code 128 directly, but a boiler struggling with poor water flow runs hotter and cycles harder, which wears ignition parts faster. On older systems we often recommend checking the system water and filtration at the same visit.

Strata homes add their own steps. Many townhouses and condos have boilers in tight closets or shared mechanical rooms, with vent terminals the strata controls. Let us know if you need building access arranged, and check whether your strata has rules about vent terminals or contractors before replacement work. We cover all of Greater Vancouver from our base in Burnaby, and the housing stock differs from city to city. The notes below are general patterns, not a description of any particular home:

  • Vancouver: a wide mix, from older character houses where hydronic systems have been converted and updated over the years to newer laneway homes and condos with compact wall-hung boilers.
  • Burnaby: our home base, with many post-war houses alongside large townhouse and strata complexes, where boiler access and terminal location are often the first things we sort out.
  • Surrey: many newer subdivisions with radiant in-floor heating, plus older ranchers where gas lines have been extended as appliances were added.
  • Richmond: a flat, wet landscape where boilers in garages and low sidewall terminals are common, so standing water, debris and condensate drainage get extra attention.
  • Coquitlam and the Tri-Cities: hillside homes in Coquitlam, Port Coquitlam and Port Moody can have terminals exposed to strong wind, and higher neighbourhoods see more snow.
  • The North Shore: North Vancouver and West Vancouver homes at higher elevations get colder nights and more snow than the rest of the region, and split-level layouts can mean long vent runs.
  • New Westminster: plenty of older and heritage housing with tight mechanical spaces and gas piping that may have been modified several times.
  • Delta: exposed, windy spots in Ladner and Tsawwassen make vent terminal placement and debris worth checking on every call.
  • Langley: a mix of newer developments and acreage properties, where long gas runs and outbuildings can affect gas pressure at the boiler.

Why trust BC Wide with a Lennox boiler code 128 lockout

BC Wide Home Services Ltd has worked on gas heating in Greater Vancouver since 1999. We are an independent, Technical Safety BC licensed gas contractor, licence LGA0090068, with Class B gas licence CGA0028029. Your boiler is diagnosed and repaired by our own licensed gas fitters, not passed along to someone else.

We are not an authorised Lennox dealer or a manufacturer warranty centre, and we will not pretend to be. If your boiler may still be under manufacturer warranty, check the warranty terms and the manufacturer process first, because some warranties set out who has to do the work. If you are out of warranty, or would simply rather have an independent technician look at it, we service the brand just as we service every other boiler brand we work on.

Gas work that needs a permit, such as boiler replacement or changes to gas piping, is done under a permit through Technical Safety BC, and the work is open to inspection. You get a written quote before any work beyond the diagnosis, a clear explanation of what we found, and a written record of what we measured and changed. No pressure, no surprise work. To book a code 128 diagnosis anywhere in Greater Vancouver, call (604) 473-9690.

More questions homeowners ask

What does Lennox boiler error code 128 mean?

Code 128 on a Lennox boiler is a flame failure (no flame / ignition lockout). The boiler failed to detect a flame, or lost the flame, and locked out for safety. Confirm the meaning against the manual for your unit. The code tells you the boiler protected itself. A technician still has to find out why the flame was not proven.

Can I reset Lennox boiler error code 128 myself?

Yes, once, and only if your owner manual allows a reset. First check that the boiler has power, the gas valve is open and the thermostat is calling for heat. If the code comes back after that one reset, stop and call a licensed gas technician. Repeated resets or cycling the power can hide a real safety problem.

Is it safe to run my Lennox boiler after code 128?

If one permitted reset clears the code and the boiler runs normally, it is generally fine to use while you book a service, because the cause has not gone away. If the code keeps returning, leave the boiler in lockout and do not force it to run. If you smell gas or a carbon monoxide alarm sounds, leave the house and call FortisBC or 911 from outside.

Why does my Lennox boiler show code 128 on windy or snowy nights?

Weather-related lockouts usually point to the vent terminal or the condensate drain. Wind can upset combustion air at an exposed sidewall terminal, while snow, leaves or a frozen outdoor condensate line can block it. Check the terminal from the ground and clear debris only if you can reach it safely. If it keeps happening, have the venting checked by a licensed technician.

Will Lennox boiler code 128 stop my hot water as well as my heat?

It depends on how your hot water is made. A combi boiler or a boiler-fed indirect tank relies on the boiler, so a lockout stops hot water, right away on a combi and once the tank is used up on an indirect. A separate gas water heater keeps working. Tell us which setup you have when you call so we can set the priority.

Can BC Wide fix Lennox boiler error code 128 near me today?

We do same-day visits across Greater Vancouver where we can, and no-heat calls go near the front of the line. We do not promise a guaranteed arrival time, and when the schedule is full we say so plainly. Call (604) 473-9690 and describe the code and any gas smell, and we will tell you honestly when a licensed gas fitter can be there.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a boiler be serviced?
Annual servicing is recommended for all residential boilers. BC Wide's annual service includes combustion analysis, heat exchanger inspection, expansion tank pressure check, condensate trap cleaning, and a full safety check. Annual maintenance is also required to keep most manufacturer warranties valid.
How much does a new boiler cost in Vancouver?
A typical residential high-efficiency gas boiler in Metro Vancouver costs $7,500–$15,000 installed, depending on size, brand, and whether the system is heating only or a combi unit that also handles hot water. BC Wide provides a free written quote with three options at different price points.
How long does a boiler last?
A well-maintained cast-iron boiler can last 25–30 years, a modern high-efficiency condensing boiler typically lasts 15–20 years, and a combi boiler 12–18 years. Annual servicing has the single biggest impact on lifespan.
My boiler is making a banging or kettling noise. Is that dangerous?
Kettling (a banging or whistling sound) is usually caused by limescale build-up on the heat exchanger and is a sign the system is overheating in localised spots. It will not always cause immediate failure but it shortens the life of the boiler and should be addressed within a few weeks.
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Yes. BC Wide is one of the few HVAC companies in the Lower Mainland with deep experience on European and high-end North American boilers including Viessmann, IBC, Baxi, Laars, Weil-McLain, NTI, Navien and Rinnai. We carry common parts in the truck.
Should I repair or replace my old boiler?
A useful rule: if the boiler is more than 15 years old and the repair cost is more than 50% of replacement, replacement is the better investment. BC Wide will give you both a repair quote and a replacement quote and let you decide.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote