Quick answer

Lennox boiler error code 13 means the control sees the water flow switch closed when it expects it open, pointing to a stuck switch, a wiring fault, a control board fault or a circulation problem. Confirm that meaning against the manual for your unit. The boiler will normally refuse to fire, so you lose heat and possibly hot water. Check power, the gas valve and the thermostat, try one reset only if the manual allows it, then call a licensed gas technician at (604) 473-9690.

If your Lennox boiler is showing 13 (Water flow switch closed), here’s exactly what it means and what to do. This guide is part of our full Lennox boiler error code list.

Severity: Needs attention.

What 13 means on a Lennox boiler

The flow/pressure switch is stuck in the closed state when the control expects it open, indicating a switch or circulation fault.

Common causes

  • Faulty or stuck flow switch
  • Wiring fault
  • Control board fault

What you can safely check first

  1. You may attempt one reset
  2. If it returns, the flow switch and wiring need a technician

Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.

When to call a technician

This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.

BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.

Lennox boiler repair across Greater Vancouver

If a Lennox boiler showing 13 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.

Related Lennox boiler codes

Frequently asked questions

Is 13 on a Lennox boiler serious?

It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lennox boilers 7 days a week across Greater Vancouver.

How do I reset a Lennox boiler after 13?

You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.

Lennox boiler error code 13: what it means for your heat, hot water and safety

In plain terms, your boiler has a small switch whose only job is to tell the control board whether water is moving through the boiler, or on some designs whether the system is holding the pressure it should. Before the burner is allowed to light, the control checks that this switch is in the position it expects for that step of the sequence. Code 13 says the switch is reporting closed when the control expects it to be open. Because the control cannot trust that signal, it stops the normal firing sequence and waits. The exact logic differs between models, so confirm the meaning against the manual for your unit before acting on it.

For your heat, that usually means the radiators, baseboard convectors or in-floor loops stop warming up. In our mild, wet coastal climate a house loses heat slowly, so many owners only notice hours later when the rooms feel damp and cool rather than cold. For your hot water, it depends on the setup. If the boiler also heats an indirect storage tank, the tank will keep supplying hot water for a while and then go lukewarm. If the boiler is the only source of domestic hot water, you may lose hot water sooner.

For your safety, code 13 on its own is a control-side fault, not a gas leak warning. The boiler is doing the right thing by refusing to fire on a signal it cannot rely on. The danger comes from what happens next. Repeated resets, jumper wires across the switch, or running the boiler with the switch bypassed remove a protection that exists to stop the heat exchanger being fired without proper water movement. A heat exchanger fired without flow can overheat, and that is the kind of damage that turns a switch repair into a much bigger conversation.

Here is how owners usually describe the problem when they call us about a Lennox boiler showing 13:

  • The display shows 13 and the radiators or floors are cold.
  • It clicks and the pump hums, but the burner never lights.
  • It worked after one reset, then the code came back within the hour.
  • The pump seems to run all the time, even when the house is already warm.
  • The code started right after a pump, zone valve or thermostat was changed.
  • The indirect hot water tank is slowly going lukewarm.
  • There is a gurgling or rushing sound in the pipes before the code appears.
What you noticeWhat it often tells usYour next step
Code 13 appears on every heat callA switch or wiring fault that is present all the timeNote the time, try one reset only if the manual allows, then call
Code 13 appears only some of the timeAn intermittent connection, a sticking switch or a control timing issueWrite down when it happens and what else was running
Pump runs constantly before the codeWater is genuinely moving when the control expects it stoppedTell us about any recent pump, zone or thermostat work
Code started after other work on the systemPossible wiring or setup change during that workKeep the paperwork from that visit for the technician
Rushing or gurgling soundsAir or debris in the loop affecting how the switch behavesDo not drain or refill yourself; book a diagnosis

What causes Lennox boiler error code 13? Likely causes, most common first

The existing guide above lists the three headline causes: a faulty or stuck flow switch, a wiring fault and a control board fault. On site, those headline causes break down into a few specific situations. The order below reflects what we tend to find first on hydronic boilers in Metro Vancouver homes, not a statistic, and every unit should be confirmed against its own manual and wiring diagram.

Metro Vancouver water is soft, so hydronic problems here are mostly sludge and corrosion debris rather than limescale. Over years, fine dark sludge from steel and iron components settles in the low-flow parts of the loop, and a flow switch is one of the places it can collect. That is why a stuck switch is so often the first thing we look at, and why we also look at the water itself rather than just swapping the switch.

  • 1. Flow switch stuck closed. Sludge, debris or simple wear holds the switch in the closed position after the water stops. Owner-safe check: one reset if the manual allows it, then note whether the code returns straight away. Licensed call: yes, the switch and its surroundings need to be tested and, if needed, cleaned or replaced.
  • 2. Circulation running when the control expects it stopped. If a pump keeps running because a relay is stuck, an external pump was wired to run continuously, or a zone controller is holding a call, water really is moving and the switch is truthfully reporting closed. Owner-safe check: make sure no thermostat is set far above room temperature and tell us about any recent zone or pump work. Licensed call: yes, the pump wiring and controls need tracing.
  • 3. Wiring fault at the switch or harness. Chafed insulation, a pinched harness, a corroded or loose connector, or moisture from a weeping fitting can make the circuit read closed even when the switch is open. Owner-safe check: look, without touching, for any visible water dripping onto the boiler or its wiring. Licensed call: yes, this is electrical diagnosis inside the appliance.
  • 4. Wiring changed during earlier work. A pump, zone valve or thermostat replaced recently and wired differently from the original is a common trigger. Owner-safe check: find the invoice or notes from that visit. Licensed call: yes, the wiring needs to be checked against the boiler’s diagram.
  • 5. Control board misreading the input. Less common, but a board can misread a correctly working switch. We only reach this conclusion after the switch, wiring and circulation have tested correctly. Owner-safe check: none. Licensed call: yes, and a board is one of the more expensive parts, so we prove it before quoting it.
Likely causeWhat we see on siteOwner-safe checkLicensed work needed
Stuck flow switchSwitch reads closed with the pump off and no flowOne reset if the manual allowsTest, clean or replace the switch
Pump running when it should notFlow present at a point in the sequence where it should be stoppedCheck thermostat settings, report recent workTrace pump relays and zone controls
Damaged or wet wiringCircuit reads closed with the switch disconnectedLook for visible drips, do not touchRepair wiring and stop the water source
Incorrect wiring after other workWiring that does not match the boiler diagramFind paperwork from the earlier visitRewire to the manufacturer diagram
Control board faultSwitch, wiring and flow all test correctly but the board still reads closedNoneConfirm the fault, then quote the board in writing

Lennox boiler code 13: what a homeowner can safely check, and what to leave alone

You are allowed to do the basic checks below. Everything beyond them is gas or electrical work inside a fuel-burning appliance, which in BC is restricted to licensed trades. Doing these checks first is useful even if you end up calling us, because it rules out the simple things and gives the technician a head start.

  • Power: confirm the boiler’s service switch is on and the breaker has not tripped. If the breaker trips again, leave it off and call.
  • Gas supply: confirm the manual gas shut-off valve to the boiler is in the open position, with the handle in line with the pipe. Do not open or adjust anything else in the gas train.
  • Thermostat: confirm it has power, is set to heat, and is calling for heat a few degrees above room temperature, not far above it.
  • One reset only, and only if the owner manual for your unit allows it. If code 13 returns, stop there; repeated resets can hide a real fault.
  • Outside intake and exhaust terminals: on a direct-vent boiler, check from outside that the terminals are clear of leaves, snow, nests or anything stacked against them.
  • Visible condensate drain: on a condensing boiler, look at the drain line and any condensate pump for an obvious kink, disconnection or overflowing reservoir. Do not take it apart.
  • Pressure gauge: read the gauge on the boiler or near it and note the number for the technician. Do not drain, refill or bleed the system to chase this code.
  • Leave alone: the burner compartment, gas valve, control board, flow switch, wiring harness, pump wiring and any jumper or bypass. Never wire around the switch to get heat back.
CheckHomeowner may do itLicensed technician only
Breaker and service switchYes, switch on onceRepeated tripping or wiring faults
Manual gas shut-off valveYes, confirm it is openAnything in the gas train beyond that valve
Thermostat settingsYesThermostat or zone wiring changes
ResetOnce, if the manual allowsAny repeat lockout diagnosis
Vent terminals outsideYes, clear visible debrisVent repairs or changes
Flow switch, board, pump wiringNoYes

How our Lennox boiler error code 13 repair visit works, step by step

We are BC Wide Home Services Ltd, an independent TSBC-licensed gas contractor (licence LGA0090068, Class B gas licence CGA0028029) working in Metro Vancouver homes since 1999. We are not a Lennox authorised dealer or warranty centre; Lennox is one of the boiler brands we service. Here is what happens when you book us for code 13.

  • 1. The call: we ask what the display shows, when it started, whether you have reset it, and whether any pump, zone or thermostat work was done recently. We book same-day where we can, but we never promise an arrival window we cannot keep.
  • 2. Safety first on arrival: the technician checks for gas odour and combustion safety around the boiler before anything else, and confirms you have working CO alarms.
  • 3. Confirm the code: we read the fault and its history if the control stores it, and check the meaning against the manual and wiring diagram for your exact model.
  • 4. Test the switch with the right meter: we check the switch state with the pump off and with the pump running, so we know whether the switch is stuck or truthfully reporting flow.
  • 5. Trace circulation and wiring: we check pump relays, any external pumps and zone controls, and look for chafed, wet or incorrectly connected wiring.
  • 6. Look at the water: on soft-water hydronic systems we check for sludge and corrosion debris, because a new switch in a dirty loop can stick again.
  • 7. Written quote before any work beyond diagnosis: you see the cause, the parts most often involved in general terms (switch, harness or connector, pump relay or control, or the board), and the price in writing before we go ahead.
  • 8. Repair and test the safeties: after the repair we run the boiler through full heat calls, confirm the flow switch and other safeties respond correctly, and check combustion and venting.
  • 9. Paperwork: you get a written record of what we found, what we changed, and anything we recommend watching. Where the work requires a gas permit, we take it out and arrange the inspection.

Should you repair or replace a Lennox boiler that keeps showing code 13?

A code 13 fault on its own is rarely a reason to replace a boiler. A stuck switch, a damaged wire or a miswired pump are repairable, and on a sound boiler we will tell you so. The question changes when code 13 is one symptom of a system that is wearing out, or when the repair would mean a control board on a boiler that already has other problems.

What decides it on site is the condition of the heat exchanger, the state of the water in the loop, how available the parts are for that model, and whether the boiler still suits the house. Older boilers in Metro Vancouver were often sized for draughtier houses; after window upgrades and insulation, some are now oversized and short-cycle. If you are looking at replacement anyway, that is the moment to get the heat loss checked rather than matching the old size.

If you do replace, we install and service modern condensing boilers and combi units from brands including Navien, Rinnai, Noritz, Bosch and A. O. Smith, discussed neutrally as an independent contractor. We will give you a written quote for repair and, if it makes sense, a separate written quote for replacement, so you can compare them side by side without pressure.

FactorLeans toward repairLeans toward replacement
Cause of code 13Switch, wiring or pump control faultCode 13 alongside other recurring faults
Heat exchanger conditionSound, no leaks or heavy corrosionLeaking, cracked or heavily corroded
Parts availabilityParts readily available for the modelParts discontinued or hard to source
Water in the loopClean or easily cleanedHeavy sludge that has damaged components
Repair scopeOne component, proven faultyControl board plus other major parts on an older unit
Fit for the houseBoiler suits the current heat lossBoiler now clearly oversized or undersized

Lennox boiler error code 13 repair near you: Greater Vancouver coverage

We service Lennox boilers and other hydronic systems across Greater Vancouver from our base in Burnaby. Housing stock varies a lot across the region, and it affects how a code 13 repair goes, so here is what we commonly see, described honestly rather than as hard rules.

Vancouver: many older houses and character homes have hydronic heat that has been modified over the decades, so extra pumps and zone controls added over time are worth tracing carefully. Burnaby and New Westminster: a mix of older houses, townhouses and strata buildings, where boilers in mechanical closets or shared spaces can make access part of the job. Surrey, Delta and Langley: many newer subdivisions and larger homes with in-floor radiant zones and more complex controls. Richmond: a lot of townhouse and strata housing where boilers often sit in tight spaces and strata rules can affect when and how work is done. Coquitlam and the rest of the Tri-Cities (Port Coquitlam and Port Moody): a mix of established houses and newer hillside and townhouse developments with zoned radiant heat. The North Shore: hillside homes in North Vancouver and West Vancouver where boiler rooms can be tucked away and vent terminals sit close to grade, so outside checks matter.

Whatever the city, the standards are the same. Diagnosis and repairs are done by our own licensed gas fitters under our TSBC gas contractor licence. Gas work that needs a permit gets one, with the inspection arranged. You get a written quote before any work beyond diagnosis, and we book same-day where we can.

Boiler and combi brands we service include Lennox, Navien, Rinnai, Noritz, Bosch, A. O. Smith, Rheem and Bradford White. We are an independent contractor, not an authorised dealer or warranty centre for any of them. Call (604) 473-9690 to book a Lennox boiler code 13 diagnosis.

Gas and carbon monoxide safety: if you smell gas or a CO alarm sounds, do not reset the boiler or touch any switches. Leave the house, then call FortisBC or 911 from outside. Keep working CO alarms on every level and near sleeping areas.

More questions homeowners ask

What does Lennox boiler error code 13 mean?

It means the control sees the water flow switch closed when it expects it to be open, so it will not run the normal firing sequence. The usual causes are a stuck switch, a wiring fault, a pump running when it should be stopped, or a control board fault. Confirm the meaning against the manual for your unit, because the logic varies by model.

Can I reset Lennox boiler error code 13 myself?

You can try one reset if the owner manual for your unit allows it. If code 13 comes back, stop resetting and call a licensed gas technician. Repeated resets do not fix a stuck switch or a wiring fault and can hide a real safety problem.

Is it safe to run my Lennox boiler with code 13 showing?

The boiler normally will not fire while code 13 is active, which is the safe outcome. What is not safe is jumping out or bypassing the flow switch to force it to run, because that removes the protection that stops the heat exchanger being fired without proper water flow. Leave the boiler in lockout and book a diagnosis.

Is Lennox boiler code 13 caused by low boiler pressure?

Not usually. Code 13 is about the switch reading closed when it should be open, which points to a stuck switch, wiring or a pump running when it should not, rather than low pressure. Read the pressure gauge and tell the technician the number, but do not drain or refill the system to chase this code.

Who repairs Lennox boiler error code 13 near me in Greater Vancouver?

BC Wide Home Services Ltd repairs Lennox boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed gas contractor, licence LGA0090068, not a Lennox dealer or warranty centre. Call (604) 473-9690 to book.

Can you fix a Lennox boiler code 13 the same day?

Same-day where we can, depending on the schedule and on whether the part is on hand. Many code 13 faults, such as wiring or pump control problems, can be repaired on the first visit, while a switch or board may need to be sourced. You get a written quote before any work beyond diagnosis either way.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a boiler be serviced?
Annual servicing is recommended for all residential boilers. BC Wide's annual service includes combustion analysis, heat exchanger inspection, expansion tank pressure check, condensate trap cleaning, and a full safety check. Annual maintenance is also required to keep most manufacturer warranties valid.
How much does a new boiler cost in Vancouver?
A typical residential high-efficiency gas boiler in Metro Vancouver costs $7,500–$15,000 installed, depending on size, brand, and whether the system is heating only or a combi unit that also handles hot water. BC Wide provides a free written quote with three options at different price points.
How long does a boiler last?
A well-maintained cast-iron boiler can last 25–30 years, a modern high-efficiency condensing boiler typically lasts 15–20 years, and a combi boiler 12–18 years. Annual servicing has the single biggest impact on lifespan.
My boiler is making a banging or kettling noise. Is that dangerous?
Kettling (a banging or whistling sound) is usually caused by limescale build-up on the heat exchanger and is a sign the system is overheating in localised spots. It will not always cause immediate failure but it shortens the life of the boiler and should be addressed within a few weeks.
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Yes. BC Wide is one of the few HVAC companies in the Lower Mainland with deep experience on European and high-end North American boilers including Viessmann, IBC, Baxi, Laars, Weil-McLain, NTI, Navien and Rinnai. We carry common parts in the truck.
Should I repair or replace my old boiler?
A useful rule: if the boiler is more than 15 years old and the repair cost is more than 50% of replacement, replacement is the better investment. BC Wide will give you both a repair quote and a replacement quote and let you decide.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote