Lennox boiler error code 133 means the boiler tried to light, could not prove a flame, and locked out, usually because the gas supply was interrupted or the flame was lost (confirm against the manual for your unit). You will normally have no heat and, on a combi, no hot water. Check that other gas appliances work, the boiler gas valve is open and the outside vent terminals are clear, then try one reset only if the manual allows it. If 133 returns, call a licensed gas technician.
If your Lennox boiler is showing 133 (Interruption of gas supply or flame failure), here’s exactly what it means and what to do. This guide is part of our full Lennox boiler error code list.
Severity: Critical — likely no heat / lockout.
What 133 means on a Lennox boiler
The boiler locked out after failing to establish a flame, typically due to interrupted gas supply (a no-ignition lockout).
Common causes
- Gas supply turned off or gas valve closed
- Gas meter / supply issue
- Ignition electrode, flame sensor or gas valve fault
What you can safely check first
- Verify the gas supply is on and other gas appliances work
- Confirm the boiler gas isolation valve is open
- Attempt one reset (hold Reset 1-3 seconds); if it returns, call a licensed gas technician
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox boiler repair across Greater Vancouver
If a Lennox boiler showing 133 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox boiler codes
- Lennox boiler 10 — External probe / sensor cable fault
- Lennox boiler 12 — Water flow switch open
- Lennox boiler 13 — Water flow switch closed
- Lennox boiler 18 — Gas valve fault
- Lennox boiler 19 — Automatic water refill enabled
- Lennox boiler 20 — Max water refill reached / Central Heating Flow or Flue NTC fault
Frequently asked questions
Is 133 on a Lennox boiler serious?
It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs Lennox boilers 7 days a week across Greater Vancouver.
How do I reset a Lennox boiler after 133?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox Boiler Error Code 133: what it means for your heat, hot water and safety
In plain terms, 133 is the boiler telling you it went through its lighting sequence and never saw a stable flame, so it shut the gas off and stopped trying. Confirm the exact wording against the manual for your unit, but the practical result is the same in nearly every home: the boiler sits in lockout until the cause is cleared and the control is reset. It is a protective shutdown. The control is doing exactly what it is designed to do, which is refuse to keep sending gas into a combustion chamber where it cannot confirm that gas is burning.
Every time your thermostat calls for heat, a modern gas boiler runs the same sequence. The control checks its safeties, the combustion fan purges the chamber, a pressure switch or sensor proves that air is moving through the vent, the igniter sparks, and the gas valve opens for a short trial period. A flame sensor then has to prove that a flame is actually present. If the sensor never sees flame, or sees it and then loses it, the boiler retries a limited number of times and then locks out. That lockout is what you are looking at on the display.
What that means for your household depends on how the boiler is set up. If it only heats radiators or in-floor loops, you lose space heat while hot water from a separate tank may carry on. If it is a combi boiler, or it heats an indirect tank, you lose hot water as well. Radiant floors and cast-iron radiators hold heat for a while, so the house cools slowly, which is why people are often slow to notice. Here is what a 133 lockout usually looks like from the homeowner’s side:
- The radiators or heated floors are going cold even though the thermostat is calling for heat.
- The hot water runs lukewarm and then cold, on a combi boiler or an indirect tank.
- You hear the fan start and a clicking or ticking from the igniter, then the boiler goes quiet.
- The display shows 133 with a lockout or reset indication instead of the normal status.
- The boiler lit after a reset but showed 133 again later the same day or the next morning.
- Other gas appliances in the house, such as the range or fireplace, are not lighting either.
- There is water near the base of the boiler, or the condensate tubing looks kinked or full.
Lennox boiler error code 133: likely causes, most common first
This is roughly the order we find causes in on Greater Vancouver service calls, from most to least common. The owner-safe column is what a homeowner can look at without tools and without opening anything. Everything in the last column is a licensed gas fitter’s job under BC rules, because it means testing gas pressure or opening the gas train, burner or control wiring.
| Likely cause | What you might notice | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| Gas supply interrupted at the meter or utility side | No gas appliance in the house will light; the cooktop burners do not catch | Try another gas appliance and check for a utility notice about work in your area | If the meter was shut off, only the gas utility turns it back on, and a licensed fitter should relight and check the appliances |
| Boiler gas isolation valve closed or partly closed | Other gas appliances work and only the boiler fails | Look at the valve on the gas line to the boiler; a handle in line with the pipe usually means open | If the valve is stiff, leaking, or you are unsure which valve feeds the boiler, stop and call |
| Fouled, cracked or misaligned flame sensor or ignition electrode | The boiler lights briefly and drops out, or lights only on the second or third try | None beyond one permitted reset; these parts sit inside the sealed burner compartment | Always licensed: cleaning, gapping or replacing electrodes means opening the burner and re-making the seal |
| Low gas pressure at the boiler | Lockouts when the range, dryer or fireplace runs at the same time, or in the coldest weather | Note which appliances were running when 133 appeared; that pattern helps the technician | Always licensed: measuring inlet and manifold pressure and checking pipe sizing is gas fitting |
| Blocked air intake or exhaust terminal | Lockouts on windy or stormy days; leaves, moss, a nest or ice visible at the outside pipes | From the ground or balcony, look at the terminals and clear loose leaves or snow by hand without disturbing the pipes | If the pipes are damaged, disconnected or sagging, or something is lodged deep inside |
| Blocked or frozen condensate drain | Gurgling at the boiler, water near the base, or a condensate pump alarm | Look along the visible drain tubing for kinks, a disconnected end or a full pump reservoir | If water is inside the cabinet or the trap needs dismantling and cleaning |
| Gas valve, ignition or control fault | Repeated 133 with gas, venting and drainage all confirmed fine | None; do not tap, jumper or bypass anything | Always licensed: needs electrical and combustion testing before any part is condemned |
Can I keep resetting a Lennox boiler with code 133, and when is it a licensed call?
One reset, and only if the manual for your unit permits it. A boiler that lights after one reset and then runs normally may have had a one-off supply interruption, such as gas utility work on the street or a valve someone bumped. A boiler that throws 133 again has told you something is genuinely wrong, and every further reset sends another trial of gas into a chamber that has already failed to prove flame. Do not keep cycling the power switch, do not open the front panel, and never jumper or bypass a sensor or switch to get heat back.
Treat 133 as a licensed call as soon as any of these is true: it has returned after one reset; you have confirmed gas is on and the valve is open and it still will not light; the boiler is lighting on a second or third attempt rather than the first; you can see water, corrosion or scorching around the cabinet or through the viewing window; or the lockout keeps happening at the same time of day or under the same conditions.
In British Columbia, work on gas appliances, gas piping and the gas train of a boiler is regulated by Technical Safety BC and must be done by a licensed gas fitter working under a licensed gas contractor. That includes cleaning or replacing a flame sensor, adjusting gas pressure, replacing a gas valve and opening the sealed combustion chamber. Most electrical work on the control circuits is restricted as well. The homeowner’s part is the outside-the-cabinet checks above and a good description of what happened. It helps to write down when 133 appeared, what the weather was doing, which other gas appliances were running and how many times it has happened, because many boilers keep only a short fault history.
Gas and carbon monoxide safety comes before getting the heat back on:
- If you smell gas (a rotten-egg or sulphur odour), do not reset the boiler, do not switch lights or appliances on or off, and do not use a phone inside. Get everyone out, then call FortisBC’s emergency line or 911 from outside.
- If a carbon monoxide alarm sounds, get everyone into fresh air and call 911 from outside. Do not go back in to check the boiler.
- Headaches, dizziness or nausea that ease when you leave the house are a warning sign of carbon monoxide. Leave and call 911.
- Keep a working CO alarm near sleeping areas and on the level with the boiler, and test it regularly.
- Never block, tape or cover the boiler’s combustion air intake or exhaust terminal, even temporarily.
- Flame failure and carbon monoxide are different faults, but they share causes: a partly blocked vent, recirculating exhaust or low gas pressure can produce both an unstable flame and poor combustion. That is why we test combustion on every 133 call rather than just getting the boiler to light.
How our Lennox boiler error code 133 repair visit works
This is the sequence our licensed gas fitters follow on a 133 call. BC Wide is an independent TSBC-licensed contractor, not a Lennox dealer or warranty centre, so we diagnose and repair the boiler you have on its merits and tell you plainly what we find.
- Step 1, the phone call. Call (604) 473-9690 and tell us the code, when it started, whether other gas appliances work and whether you smell gas. We book same-day where we can. In a cold snap the schedule fills quickly, so we tell you honestly when we can and cannot get there and never promise an arrival window we cannot keep.
- Step 2, safety first on arrival. We check for gas leaks around the boiler, the piping and the meter with a detector, check carbon monoxide levels in the room, and look at the vent terminals before touching the controls.
- Step 3, read the history. We note the code, any lockout history the control stores, and the conditions you recorded, then watch a full ignition attempt to see exactly where in the sequence it fails.
- Step 4, measure instead of guessing. We test gas pressure at the boiler inlet with the boiler firing and with other gas appliances running, read the flame signal from the sensor with a meter, check ignition, grounding and polarity, and confirm the air-proving switch and venting.
- Step 5, inspect the burner side. If the readings point there, we open the sealed burner compartment to inspect the flame sensor, ignition electrode, burner surface and insulation, and check the condensate trap and drain.
- Step 6, a written quote before work. Diagnosis comes first. If the repair goes beyond diagnosis, you get a written quote that describes the fault, the part or work needed and why, before we do anything further. You decide whether to go ahead.
- Step 7, repair and re-test. After the repair we run the boiler through repeated ignition cycles, test the safeties, check combustion with an analyser, confirm the vent and condensate are clear, and leave the system heating and, where applicable, making hot water.
- Step 8, paperwork. You get a written record of what was found and what was done. Where the work requires a gas permit, we pull it and arrange the inspection.
Repair or replace an older Lennox boiler that keeps showing 133?
The parts most often involved in flame-failure lockouts, in general terms, are the flame sensor or ignition electrode, the ignition lead and grounding, the gas valve, the condensate trap and drain, and occasionally the control board. A control board or gas valve is one of the more expensive parts on a boiler, which is exactly why we prove the fault with meters before recommending either. Plenty of 133 calls turn out to be supply, venting, drainage or sensor problems rather than a major component.
One 133 lockout on a boiler that has otherwise been reliable is almost always a repair. The question changes when the code keeps coming back on an older unit, especially alongside other faults. The point at which a boiler is worth replacing varies a great deal with how it was installed and maintained, so we judge the condition of the unit in front of us rather than its age alone.
In Metro Vancouver, our soft water means the hydronic side of a boiler rarely suffers from limescale. What we find instead is sludge and corrosion: magnetite and debris in older loops, particularly where steel pipe or old radiators share a system with a newer condensing boiler. Sludge is hard on the heat exchanger and can make the boiler short-cycle, which adds wear to the ignition parts. It is one of the factors in a repair-or-replace conversation.
- If replacement makes sense, we show you why in writing and give you written quotes for each option side by side, so you can compare a like-for-like gas boiler with any other approach that suits the house, including dual-fuel options that keep gas heat as backup for cold snaps.
- We will not push a replacement on a boiler that only needs a sensor cleaned or a drain cleared.
- Ask for the repair quote and the replacement quote together and decide with both in hand.
| Factor | Leans toward repair | Leans toward replacement |
|---|---|---|
| Lockout history | First or occasional 133 with a clear cause found and fixed | Repeated lockouts over several seasons with different causes each time |
| Heat exchanger condition | Clean, dry, no visible corrosion | Corrosion, weeping or heavy sludge damage visible on inspection |
| Parts availability | Parts readily available through supply houses | Key parts discontinued or hard to source |
| Venting and terminals | Venting and terminal locations meet current requirements | Venting needs major rework even to keep the existing boiler |
| Comfort and hot water | House heats evenly and hot water meets the household’s needs | Uneven heat, frequent cold showers, or the household has outgrown the system |
| Scope of the repair | A sensor, electrode, drain or gas pressure correction | A heat exchanger or several major parts at once on an older unit |
Lennox boiler error code 133 repair near you in Greater Vancouver
Our licensed gas fitters work on boilers throughout Greater Vancouver from our base in Burnaby, where BC Wide has operated since 1999. Coverage includes Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities (Port Coquitlam and Port Moody), the North Shore (North Vancouver and West Vancouver), New Westminster, Delta and Langley.
The housing stock shapes how a 133 call goes. Many older detached homes in Vancouver, Burnaby and New Westminster have hydronic systems that were converted to a condensing boiler at some point, sometimes on a gas line originally sized for a smaller load that later picked up a range, fireplace or dryer. Those are the homes where low gas pressure under combined demand tends to come up. Newer townhouses and condos in parts of Surrey, Richmond, Coquitlam and Langley more often have combi boilers in closets with sidewall or rooftop terminals, where condensate routing and terminal clearances matter more. On the North Shore and in leafier parts of Delta, rain, moss and tree debris at intake and exhaust terminals are a frequent find. Every house is different, so we confirm on site rather than assume.
In strata buildings the vent terminal may sit on a balcony or a common wall, and the gas meter may be in a shared meter room. If the work touches common property or a shared gas line, we coordinate with your strata manager or building operator before we start.
Our mild, wet coastal climate is easy on boilers in one way and hard in another. Long damp shoulder seasons keep boilers cycling on and off, which works the ignition system harder than a steady winter load. Wind-driven rain and the occasional snowfall can push water or ice at sidewall terminals. Cold snaps are short, but they are exactly when every gas appliance in the house runs at once.
Boiler and combi brands we service include Lennox, IBC, Navien, Rinnai, Bosch and Noritz. We are an independent contractor, not a dealer or factory-authorized service centre for any of them, and we work on the equipment you already have. Why homeowners call us for a 133 lockout:
- TSBC-licensed independent gas contractor, licence LGA0090068, with Class B gas licence CGA0028029.
- Repairs done by our own licensed gas fitters.
- Gas permits pulled and inspections arranged wherever the work requires them.
- A written quote before any work beyond diagnosis, with the fault explained in plain language.
- Same-day where we can, and honest timing when we cannot.
- Call (604) 473-9690 to book a Lennox boiler visit anywhere in Greater Vancouver.
More questions homeowners ask
What does Lennox boiler error code 133 mean?
It means the boiler tried to light, could not prove a flame, and locked out; this page describes it as an interruption of gas supply or flame failure. Confirm the exact wording against the manual for your unit. The usual result is no heat, and no hot water on a combi or indirect-tank system, until the cause is fixed and the boiler is reset.
Can I reset a Lennox boiler showing code 133?
Once, and only if the manual for your unit allows it, after you have confirmed the gas is on and the boiler gas valve is open. If 133 comes back, stop resetting and call a licensed gas technician. Repeated resets send more gas into a chamber that has already failed to prove flame and can hide a real safety problem.
Is it safe to run my Lennox boiler after a 133 lockout?
If it reset once and runs normally, with no gas smell and no CO alarm, it is generally reasonable to use while you book a check. If it locks out again, lights roughly or you smell gas, do not keep running it. With a gas smell or a CO alarm, leave the house and call FortisBC or 911 from outside.
Why does my Lennox boiler show 133 when the stove or fireplace is on?
That pattern usually points to gas pressure dropping at the boiler when other appliances draw gas at the same time, which can come from undersized piping or a supply problem. It is not something a homeowner can test or fix. A licensed gas fitter measures pressure under load and corrects the piping or supply if needed.
Can a blocked vent cause Lennox boiler code 133?
Yes, it can contribute. A blocked or partly blocked intake or exhaust terminal, or exhaust being drawn back into the intake, can make the flame unstable so the sensor loses it. You can safely clear loose leaves or snow from outside terminals by hand; anything damaged or lodged inside the pipe needs a technician.
Who fixes Lennox boiler error code 133 near me in Greater Vancouver?
BC Wide’s licensed gas fitters repair boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor, not a Lennox dealer, and you get a written quote before any work beyond diagnosis. Call (604) 473-9690; we book same-day where we can.
- Lennox furnace g61mpv error codes
- Lennox furnace error code 225
- Goodman furnace error codes 6 blinks
- Boiler error message f28
- Miller furnace error codes
- Kelvinator furnace error codes
- Lennox furnace error code 270
- Airquest furnace error codes
- Heil furnace error code 4
- John Wood Water Heater Error Codes & Troubleshooting in Greater Vancouver
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.