Lennox boiler error code 135 means the boiler’s control has logged an interruption of the gas supply as an internal error, so it stops firing and usually locks out. That leaves you with no heat, and no hot water if the boiler also heats your water. Confirm the meaning against the manual for your unit. Check that the gas valve is open, the power is on and your other gas appliances work. Reset once, and only if the manual allows it. If 135 comes back, call a licensed gas fitter. If you smell gas, leave and call FortisBC or 911 from outside.
If your Lennox boiler is showing 135 (Interruption of gas supply (internal error)), here’s exactly what it means and what to do. This guide is part of our full Lennox boiler error code list.
Severity: Critical — likely no heat / lockout.
What 135 means on a Lennox boiler
An internal control error related to interruption of the gas supply / combustion.
Common causes
- Gas supply problem
- Gas valve or control board fault
What you can safely check first
- Confirm gas supply is on
- This is an internal/gas-control fault – call a licensed technician
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox boiler repair across Greater Vancouver
If a Lennox boiler showing 135 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox boiler codes
- Lennox boiler 10 — External probe / sensor cable fault
- Lennox boiler 12 — Water flow switch open
- Lennox boiler 13 — Water flow switch closed
- Lennox boiler 18 — Gas valve fault
- Lennox boiler 19 — Automatic water refill enabled
- Lennox boiler 20 — Max water refill reached / Central Heating Flow or Flue NTC fault
Frequently asked questions
Is 135 on a Lennox boiler serious?
It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs Lennox boilers 7 days a week across Greater Vancouver.
How do I reset a Lennox boiler after 135?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox Boiler Error Code 135: what it means for your heat, hot water and safety
In plain terms, code 135 means the boiler went to fire and the gas was not there the way it expected. Its control treated that as an internal fault rather than something to retry forever. The meaning at the top of this page stands: an internal control error tied to an interruption of the gas supply or combustion. Confirm it against the manual for your unit, because the exact wording, and whether the boiler retries before it locks out, can differ between Lennox boiler generations.
Day to day, the effect is simple. The burner will not stay lit, so the hydronic loop stops getting heat. Radiators, baseboard convectors or in-floor radiant zones cool off over a few hours. In a well-insulated house you may not notice until the next morning. If the boiler also makes your domestic hot water, either as a combi or by heating an indirect tank, the hot water runs out too. The circulator pump may keep running for a while, so the boiler can sound busy even though nothing is being heated.
On safety, a lockout means the boiler is protecting you. It stopped firing because conditions were not right. The risk comes from what happens next: resetting it over and over, fiddling with the gas valve, or assuming the gas utility will sort it out and waiting days. If the lockout is hiding a real gas pressure problem or a failing gas valve, don’t keep running the boiler like that.
Here is how homeowners usually describe code 135 when they call us:
- The house is cold and the thermostat is calling for heat, but the boiler is silent or only the pump is humming.
- The display shows 135, sometimes with a lockout or service message next to it.
- Hot water goes lukewarm and then cold, if the boiler also heats the household water.
- The boiler clicks and tries to light, gives up, and shows the code again.
- It started right after gas work, a new gas appliance, a FortisBC meter change or a power flicker.
- A reset gets it going for a day or two, then 135 comes back, often on the coldest mornings when everything in the house is running.
Lennox Boiler Error Code 135: what we check first, most likely cause first
The order below is how we work through a gas-supply fault on site. We start with the simplest explanations and finish with the internal electronics. It is a working order, not a statistic. Your boiler may skip straight to cause five. For each cause, the table shows what an owner can safely look at and where it becomes work for a licensed gas fitter.
1. The gas is off or was interrupted upstream. A shut-off valve left closed after other work, a meter that was turned off, or utility work on the street will all starve the boiler. If the stove, fireplace and water heater have no gas either, the problem is not the boiler.
2. Gas pressure is low or unstable at the boiler. This is the cause we find most often in older Metro Vancouver houses that have added gas appliances over the years. The gas line was sized for the original furnace or boiler and a water heater. Now it also feeds a range, a fireplace and maybe a tankless water heater. When everything fires at once, the boiler at the end of the run gets less gas than it needs and drops out.
3. Air in the gas line after new piping or meter work. A line that was opened and not properly purged can deliver a slug of air instead of gas, and the boiler fails to light. This usually shows up right after gas work and needs the line purged correctly.
4. The gas valve on the boiler is failing. A valve that opens slowly, opens inconsistently or does not open at all looks to the control like the gas has vanished. We test this with meters, not by guessing.
5. The control board or its wiring has a fault. This is the internal part of an internal error. Loose or corroded connectors, a damaged wiring harness, an unstable power supply or a board hit by a surge can all report a gas interruption that never happened.
6. Combustion-side problems the control reads as a lost flame. A blocked intake or exhaust terminal, a condensate trap backing up into the boiler, or a weak flame signal from a dirty or worn flame sensor can all end the burn cycle in a way that points back to this code.
| Likely cause | What you can check safely | When it becomes a licensed call |
|---|---|---|
| Gas off or interrupted upstream | See if the stove, fireplace or water heater lights. Check that the lever on the boiler’s gas shut-off is parallel to the pipe. | If nothing in the house has gas, call FortisBC. If only the boiler is affected, call a gas fitter. |
| Low or unstable gas pressure | Note whether 135 appears when other gas appliances are running at the same time. | Always. Measuring pressure at rest and under load takes a manometer and a licensed gas fitter. |
| Air in the line after gas work | Write down when the gas work was done and by whom. | Always. Purging a gas line is licensed gas work. |
| Failing gas valve | Nothing to check. Do not touch or adjust the valve. | Always. Only a gas fitter can test or replace a gas valve. |
| Control board or wiring fault | Confirm the boiler’s service switch and breaker are on. Do not open the cabinet. | Always. Live-voltage diagnosis inside the boiler is licensed work. |
| Blocked venting, condensate or weak flame signal | Look at the outside terminals for snow, leaves or nests. Check that the visible condensate line is not kinked or pooling. | If the terminals are clear and the code persists, or if water is collecting inside or under the boiler. |
Can I reset Lennox boiler code 135 myself? The one-reset rule and the safety line
Yes, once, and only if the manual for your unit says a manual reset is allowed for this lockout. A reset is a test. If the boiler fires and stays running, the cause may have been a passing interruption, like utility work or a closed valve you have just opened. If it locks out with 135 again, the boiler is telling you the problem is real, and every reset after that is just repeating a failed ignition attempt. Do these checks first, in this order:
Do not remove the boiler’s front panels, do not open the gas train or burner compartment, and do not jumper, bypass or disconnect any safety switch or sensor. Do not adjust the gas valve or the regulator. Do not keep cycling the power to force a light-off. Gas work and most electrical work inside a boiler are legally restricted to licensed trades in BC, and those rules exist for a reason.
The safety line is simple. If you smell gas, which most people describe as rotten eggs, do not flip switches, use the phone indoors or try to relight anything. Get everyone out, then call FortisBC’s emergency line or 911 from outside. If a carbon-monoxide alarm sounds, get everyone into fresh air and call 911. Carbon monoxide has no smell, so make sure you have working CO alarms near sleeping areas and on every level with a fuel-burning appliance. Before you leave, it helps to note what the display showed and when it happened, because that history speeds up diagnosis.
- Power: make sure the boiler’s service switch is on and its breaker has not tripped. A boiler that lost power mid-cycle can come back confused.
- Gas: find the shut-off valve on the gas line to the boiler. The lever should sit parallel to the pipe. Then check whether another gas appliance in the house lights normally.
- Thermostat: make sure it is set to heat and set above the room temperature, so the boiler is actually being asked to run. Replace the batteries if it uses them.
- Outside terminals: on a sealed-combustion boiler, look at the intake and exhaust pipes where they leave the house. Clear snow, leaves or debris by hand, from outside only. Leave a nest for the technician.
- Condensate drain: look at the visible drain line and any pump. Check that it is not kinked, frozen or overflowing. Do not take the trap apart.
- One reset: if the manual allows it, reset once and watch for a few minutes. If 135 comes back, stop and call (604) 473-9690.
How our Lennox boiler error code 135 repair visit works, step by step
Code 135 is a gas-and-controls fault, so the visit is built around measuring, not swapping parts until the code goes away. Here is what a correct diagnostic looks like from our side, and what you should see in writing at the end.
On timing: we work same-day where we can. That depends on how many no-heat calls are already booked and where you are in Greater Vancouver. We will tell you honestly what is realistic when you call, and we never promise a guaranteed arrival window.
In general terms, the parts most often involved in a gas-supply internal error are the gas valve, the control board, the igniter and flame sensor, and the wiring harness that connects them. Just as often the boiler itself is fine, and the fix is upstream: a properly sized gas line, a correct purge after gas work, or a fault FortisBC has to correct at the meter or regulator. A control board is one of the more expensive parts on a modern boiler, which is exactly why we prove it has failed before recommending one. The written quote names the part, the reason and the testing behind it.
BC Wide Home Services Ltd is an independent contractor licensed by Technical Safety BC (gas contractor licence LGA0090068, Class B gas licence CGA0028029). We have served Metro Vancouver since 1999. Our own licensed gas fitters do the diagnosis and repair. When the work needs a gas permit, such as a boiler replacement or a change to the gas piping, we take out the permit and arrange the inspection. We are not a Lennox authorized dealer or warranty centre. If your boiler may still be under manufacturer warranty, check the warranty terms and the manufacturer’s service requirements before any repair, and we will tell you up front if that affects who should do the work.
- Step 1, the phone call: we ask what the display shows, when 135 first appeared, whether other gas appliances work, whether there was recent gas work or a meter change, and whether the boiler also heats your water.
- Step 2, safety first on arrival: we check for gas leaks around the boiler, the gas line and the connections, and check the room for carbon monoxide before anything is fired.
- Step 3, fault history: we read the stored faults on the control, because the pattern of earlier lockouts often points to the cause before a single tool comes out.
- Step 4, gas supply: we measure the gas pressure going into the boiler, both at rest and while the boiler and other gas appliances are firing. We also check whether the gas line is sized for the total load the house now carries.
- Step 5, ignition and flame: we watch the light-off sequence, measure the flame signal with a meter, and inspect the igniter and flame sensor.
- Step 6, gas valve and control: we confirm the board is sending the right signal to the gas valve and the valve is responding. Then we check connectors, the wiring harness, grounding and the board’s power supply.
- Step 7, venting and condensate: we inspect the intake and exhaust from end to end, plus the condensate trap and drain.
- Step 8, a written quote before any work beyond diagnosis: you see the cause, the fix and the parts involved before we start the repair.
- Step 9, repair and verify: after the repair we run a combustion analysis. We then test the safeties, including the high limit, low-water protection and flame proving, to confirm they shut the burner down when they should.
Repair or replace a Lennox boiler that keeps showing code 135?
One code 135 lockout almost never justifies a new boiler. The question only comes up when 135 keeps coming back, when the part that failed is expensive or hard to get, or when the boiler is old enough that more failures are coming. Here is how we weigh it with owners.
First, find out whether the boiler is really at fault. If the cause is an undersized gas line or low pressure, a new boiler on the same line can throw the same kind of fault. In that case the money belongs in the gas piping, not the appliance. Second, look at the boiler’s condition. Metro Vancouver water is soft, so hydronic systems here tend to suffer from sludge and corrosion inside the loop, not limescale. A boiler pushing heat through a dirty, corroded loop works harder and wears its components faster. Third, look at parts support. On older Lennox boiler models, some control parts can become slow or difficult to source, and that matters when the house is cold.
- Repair usually makes sense when the boiler is well within its expected service life, the heat exchanger and venting are in good condition, the fault traces to one component or the gas supply, and parts are readily available.
- Replacement deserves a serious look when the boiler is near the end of its expected life, there have been several significant repairs in recent years, the heat exchanger shows corrosion or leaks, or key control parts are no longer reasonably available.
- Before any replacement, ask for a room-by-room heat-loss calculation rather than a like-for-like size swap, a check of the gas line against the new load, a venting plan that meets current code, and a plan to clean and treat the hydronic loop.
- If you also want air conditioning, ask about a dual-fuel setup: a heat pump for mild weather, with a gas appliance kept as backup for cold snaps. Your installer can explain how that would fit with your hydronic system.
- Whatever you decide, get it in writing: a written quote that lists the scope, the permit, the commissioning steps and what is not included.
Lennox boiler error code 135 service near you in Greater Vancouver
We service gas boilers and hydronic systems across Greater Vancouver from our base in Burnaby. Housing stock shapes how a gas-supply fault shows up, so here is what we tend to see. These are patterns from our work, not statistics, and your house may be different.
Vancouver and New Westminster: many older homes have gas piping that was added to piece by piece over the decades. A boiler at the end of a long, older run is the classic setup for pressure dropping out when other appliances fire. Burnaby: a mix of older detached houses and newer townhomes, where boilers often sit in tight mechanical closets and venting routes are constrained. Surrey and Langley: many newer and larger homes, plus some rural properties with long gas runs, where the household gas load has often grown since the original build. Richmond and Delta: a lot of houses and townhomes with mechanical rooms at ground level or in garages, where condensate drainage and access matter. Coquitlam and the Tri-Cities, meaning Coquitlam, Port Coquitlam and Port Moody, and the North Shore: hillside lots, wetter and leafier conditions, and intake and exhaust terminals that collect leaves and debris through fall and winter.
In strata buildings and multi-unit homes, gas supply and venting can involve common property. If your boiler serves a strata unit, check with your strata manager about who controls the gas meter and the shared venting before work starts. We can coordinate with them.
Boiler brands we service include Lennox, IBC, Viessmann, Weil-McLain, Lochinvar, Buderus, Navien, Rinnai and Bosch. We are an independent licensed contractor that services these brands. We are not certified, authorized or appointed by any of them. Call (604) 473-9690 to book a diagnostic anywhere in our Greater Vancouver service area.
More questions homeowners ask
What does Lennox boiler error code 135 mean?
It means the boiler’s control has logged an interruption of the gas supply or combustion as an internal error and stopped firing, usually with a lockout. Confirm the exact meaning against the manual for your unit. In practice you lose heat, and you lose hot water too if the boiler heats your water.
Can I reset Lennox boiler error code 135?
Once, and only if the manual for your unit allows a manual reset for this lockout. First check the power, the gas valve, the thermostat and the outside vent terminals. If 135 comes back after one reset, stop and call a licensed gas fitter, because repeated resets can hide a real gas or control fault.
Is it safe to run my Lennox boiler after code 135 clears?
If it cleared after you opened a closed gas valve or after utility work finished, and it runs normally with no gas smell, it is generally fine to keep using it while you watch for the code. If the code clears and then returns, or you notice any gas smell or CO alarm, stop using the boiler. If you smell gas, leave and call FortisBC or 911 from outside.
Why does my Lennox boiler show code 135 when my gas stove works fine?
A working stove proves gas is reaching the house, not that enough gas at the right pressure is reaching the boiler. Undersized or overloaded gas piping, a failing gas valve or a control fault can all trigger 135 while other appliances light normally. A gas fitter has to measure the pressure at the boiler under load to know which it is.
Can you fix Lennox boiler error code 135 the same day?
Same-day where we can, depending on how many no-heat calls are already booked and where you are. Many gas-supply and wiring faults can be fixed on the first visit. A failed gas valve or control board may need parts ordered. We tell you honestly what is realistic and never promise a guaranteed arrival window.
Does Lennox boiler code 135 mean I need a new boiler?
Usually not. Code 135 often traces to the gas supply, a gas valve or a control or wiring fault, and all of those can be repaired. Replacement only becomes a real question if the boiler is near the end of its life, the heat exchanger is in poor condition or the parts are hard to get, and you get a written quote either way.
- Lennox furnace g61mpv error codes
- Lennox furnace error code 225
- Goodman furnace error codes 6 blinks
- Boiler error message f28
- Miller furnace error codes
- Kelvinator furnace error codes
- Lennox furnace error code 270
- Airquest furnace error codes
- Heil furnace error code 4
- John Wood Water Heater Error Codes & Troubleshooting in Greater Vancouver
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.