Lennox boiler error code 20 means one of two things, depending on context: the boiler has reached its maximum number of automatic water refills, or a central-heating flow or flue NTC temperature sensor circuit is faulty (confirm against the manual for your unit). Either way the boiler has locked out to protect itself. Check for visible leaks, note the pressure gauge, reset once only if your manual allows it, then call a licensed gas technician. BC Wide services Lennox boilers across Greater Vancouver: (604) 473-9690.
If your Lennox boiler is showing 20 (Max water refill reached / Central Heating Flow or Flue NTC fault), here’s exactly what it means and what to do. This guide is part of our full Lennox boiler error code list.
Severity: Needs attention.
What 20 means on a Lennox boiler
Depending on context, the maximum number of automatic water refills has been reached, or an NTC temperature sensor (central-heating flow or flue) circuit is faulty.
Common causes
- Repeated auto-refills due to a persistent leak
- Faulty or disconnected flow/flue NTC sensor
- Sensor wiring fault
What you can safely check first
- Check for visible leaks and watch the pressure gauge
- Sensor faults require a technician – do not attempt to replace sensors yourself
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox boiler repair across Greater Vancouver
If a Lennox boiler showing 20 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox boiler codes
- Lennox boiler 10 — External probe / sensor cable fault
- Lennox boiler 12 — Water flow switch open
- Lennox boiler 13 — Water flow switch closed
- Lennox boiler 18 — Gas valve fault
- Lennox boiler 19 — Automatic water refill enabled
- Lennox boiler 40 — Central Heating Return NTC fault
Frequently asked questions
Is 20 on a Lennox boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lennox boilers 7 days a week across Greater Vancouver.
How do I reset a Lennox boiler after 20?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox Boiler Error Code 20: what it means for your heat, hot water and safety
In plain owner words, code 20 is the boiler telling you it has stopped trusting either its water supply or its temperature readings. On the refill side, a boiler with an automatic fill tops up the heating loop when the pressure drops. That should happen rarely. When it keeps happening, the control counts the refills and, once it reaches its limit, locks out rather than keep pouring fresh water into a system that is losing it somewhere. On the sensor side, the boiler relies on NTC thermistors to know how hot the water leaving the heat exchanger is and how hot the flue gases are. If one of those circuits reads something impossible, the control cannot safely fire the burner, so it shuts down.
What you notice depends on how your system is set up. Most owners describe some combination of the following.
The important point: code 20 is a protective lockout, not a gas leak warning. The boiler is doing its job by refusing to run. It is, however, a fault that keeps coming back until the cause is found, and on a gas appliance, a boiler that is reset over and over is a boiler being run outside the conditions its safeties expect. If you ever smell gas or your carbon monoxide alarm sounds, stop reading: leave the house, do not operate switches or the boiler on your way out, and call FortisBC or 911 from outside.
- Radiators, baseboard convectors or in-floor heat going lukewarm, then cold
- The display showing 20 with the burner off and the pump quiet or only running briefly
- If your Lennox is a combi model, no hot water at the taps either, because the same burner makes your domestic hot water
- The pressure gauge sitting lower than it normally does, or creeping back up after the boiler refills itself
- Water marks, a damp tray, or a white or rusty crust under a valve, a fitting or the relief-valve discharge pipe
- The code clearing after a reset, then returning hours or days later
Lennox boiler error code 20: likely causes, most common first
These are the causes we find most often behind this code, listed in the order we tend to find them on Greater Vancouver boilers. The owner-safe check in each row is the full extent of what a homeowner should do. Everything past that point involves gas controls, live wiring or pressurised hot water, and it belongs to a licensed technician.
Two of these deserve a closer word. On Metro Vancouver hydronic systems, the slow leak and the weeping relief valve are tied to how our water behaves. Our municipal water is soft, so we rarely see limescale inside heating loops. What we see instead is sludge and corrosion: magnetite and rust particles that circulate, settle in low spots and foul valves, air vents and sensor pockets. Every litre of fresh water an auto-fill adds brings in new dissolved oxygen, which feeds more corrosion, which makes more sludge. A boiler that has been quietly refilling itself for months has usually been speeding up its own wear, which is exactly why the control is designed to stop counting and lock out.
The sensor causes are less dramatic but just as real. An NTC thermistor changes its electrical resistance as its temperature changes. When a sensor fails or its connector corrodes, the control sees a reading that cannot belong to a working boiler and refuses to fire. A technician confirms this by measuring resistance at a known temperature and comparing it with the manufacturer-published chart for your model, not by swapping parts until the code clears.
What not to do: do not open the cabinet, unplug or replace sensors, jumper or bypass anything, cap a dripping relief valve, bleed radiators on a boiler that is already losing pressure, or keep resetting. If your owner manual describes a pressure top-up procedure, doing it once and writing down the reading is reasonable; doing it every day only feeds the leak. One reset, only if your manual permits it, is the limit.
| Likely cause | What is going on | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Slow leak in the heating loop | Water escapes from a radiator valve, a manifold, a fitting or a pipe; pressure drops and the auto-fill keeps topping up until it reaches its refill limit | Look along visible piping, radiator valves and under the boiler for drips, stains or crust; write down the gauge reading morning and evening | When the gauge keeps falling or you find a wet fitting; hidden leaks in walls or slabs need isolation and pressure testing |
| 2. Weeping pressure relief valve | If the expansion tank has lost its air charge, pressure spikes as the water heats and the relief valve dumps water, which the boiler then replaces | See whether the relief-valve discharge pipe is wet or dripping into its drain or bucket | Right away; relief valves and expansion tanks are safety devices and are never adjusted, capped or recharged by an owner |
| 3. Air vent or bleed point losing water | Automatic air vents meant to release air can stick open and spit water, especially on systems carrying sludge | Look for damp marks or drips at vents on top of the boiler, on the pipework or at high points | When a vent is wet; it is serviced or replaced with the system isolated and depressurised |
| 4. Faulty central-heating flow NTC sensor | The thermistor on the heating flow reads out of range, so the control cannot judge water temperature | Note whether the code appeared with no sign of water loss, or after a power outage or surge | Always; testing needs a meter, the manufacturer resistance chart and access inside the cabinet |
| 5. Faulty flue NTC sensor | The sensor that monitors flue gas temperature reads open or shorted, so the boiler cannot confirm safe combustion conditions | Confirm the outside intake and exhaust terminal is clear of snow, leaves, debris or nests | Always; the flue sensor is part of the combustion safety chain |
| 6. Sensor wiring or connector fault | A loose, corroded or chafed connection, often below an old drip, makes a good sensor look bad | Look, without opening any panel, for signs that water has run down the boiler casing | Always; the repair is inside the control compartment |
How our Lennox boiler error code 20 repair visit works, step by step
Here is what a correct visit looks like when one of our licensed gas technicians arrives for a code 20. You are welcome to watch any part of it, and you will not be asked to approve a repair before you know exactly what it is and why.
Besides Lennox, the boiler and combi brands we service include Navien, Rinnai, Bosch, Noritz, Takagi, Rheem, Bradford White and A. O. Smith. We are an independent contractor, not a factory-authorized dealer or warranty centre for any of them, so if your boiler may still be under manufacturer warranty, check the warranty terms before booking a repair, and tell us so we can document the fault properly.
- Step 1, the phone call. We ask what the display shows, whether the code clears after one reset, what the pressure gauge reads, whether you have heat and hot water, and whether you have seen water anywhere. We book same-day where we can; in a cold snap the schedule fills, and we tell you honestly if the earliest slot is the next day.
- Step 2, safety first on arrival. Before anything else the technician checks for gas odour and combustion spillage around the boiler and its venting, and confirms there is a working carbon monoxide alarm nearby.
- Step 3, read the history. Many boilers keep recent fault information. The technician reviews it alongside your account of when the code started to decide whether this is the refill branch or the sensor branch of code 20.
- Step 4, the water side. With the system cool and safe, the technician checks the cold fill pressure, the expansion tank air charge, the relief valve, the auto-fill and every accessible fitting, valve and vent. If the loss is not visible, the loop is isolated and pressure-tested zone by zone until the leak is located.
- Step 5, the sensor side. With the right meter, each NTC sensor and its wiring is tested against the manufacturer-published resistance values for your model, and connectors are inspected for corrosion, heat damage or water tracking.
- Step 6, a written quote before any work beyond diagnosis. You get the cause in plain language, the repair options and a written quote. Nothing is replaced until you approve it.
- Step 7, the repair and the safeties. In general terms, the parts most often involved are a sensor, a connector or harness section, a relief valve, an expansion tank, an air vent, or a leaking valve or fitting. Afterwards the technician refills and purges the loop, checks pressure cold and hot, confirms combustion, tests the safety controls and runs the boiler through a full heating call, plus a hot water draw on a combi.
- Step 8, the paperwork. Your invoice names the cause, what was replaced, the readings that confirmed the fix, and anything worth watching, such as sludge in the loop or a valve near the end of its life.
Should I repair or replace an older Lennox boiler with code 20?
For most code 20 calls the honest answer is repair. A failed sensor, a corroded connector, a worn relief valve or an expansion tank that has lost its charge are normal service items, and replacing a whole boiler over one of them makes no sense. The decision only changes when code 20 turns out to be a symptom of something larger.
Replacement belongs in the conversation when the water loss traces back to the boiler itself, such as a leak inside the heat exchanger; when the system has run on fresh make-up water for so long that the heat exchanger is fouled and corroded; when parts for your particular model are hard to source; or when this repair would be one of several in a short span. A heat exchanger is one of the most expensive parts on any boiler, and on an older unit it often tips the decision.
On a sludged loop, a correct repair is often more than one part. Flushing the system, fitting or cleaning a dirt separator or magnetic filter where one makes sense, and dosing the water with a suitable inhibitor protect the new parts and the boiler from the same cycle starting again. We explain why each item is on the quote, and you can decline anything that is not essential to the fault.
If replacement does come up, we quote it in writing with the permit and inspection included, and we size the new gas boiler or combi from a heat-loss assessment rather than simply matching the old nameplate. We will not push replacement to clear a code that a proper repair fixes.
- Repair usually makes sense: a single failed sensor or connector, a relief valve or expansion tank fault, an external leak at a valve or fitting, or a boiler that otherwise runs cleanly
- Ask for a replacement quote alongside the repair quote: a leak inside the boiler, heavy corrosion inside the cabinet, parts that are difficult to source, or repeated lockouts across different faults
- Plan the loop as well as the boiler: if the leak is in buried or in-slab piping, the repair plan for the piping matters as much as the boiler decision
Lennox boiler error code 20 service near me: Greater Vancouver coverage
We service Lennox boilers across Greater Vancouver from our Burnaby base, including Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. The housing stock varies a great deal across that area, and it shapes how a code 20 call usually unfolds.
In Vancouver and Burnaby we work on many older houses where a newer boiler has been connected to hydronic piping that was installed long before it. Mixed pipe materials and long-serving radiator valves are common places for slow leaks, and older loops tend to carry more sludge, so the refill branch of code 20 is the one we often chase there.
Older homes in New Westminster and on the North Shore can have heating runs hidden inside walls and floors, which makes pressure testing by zone the only sensible way to find a leak. Hillside lots can also put the venting terminal in awkward or sheltered spots, which matters when the flue sensor branch is involved.
In the Tri-Cities, Surrey, Richmond, Delta and Langley we see a wide range of homes, including newer houses and townhomes with in-floor radiant heat on manifolds, where a leaking manifold fitting or a tired expansion tank is a frequent trigger.
Strata townhomes and some low-rise buildings add a step. The boiler may be yours, but access, venting through shared walls and any work touching common property can need the strata’s approval. We help you sort that out before work begins so the repair is not held up halfway.
Our mild, wet coastal climate means boilers run long, gentle seasons rather than short, hard ones, so a slow leak can go unnoticed for months before the refill limit is reached. Heavy autumn rain and leaf fall make a fouled outside terminal more likely than snow here, though a snowfall can still bury a low-mounted terminal.
Who should fix Lennox boiler error code 20: licences, permits and what you should see in writing
In BC, work on gas appliances is restricted to licensed gas fitters working under a licensed gas contractor, and most electrical work inside the boiler is restricted too. That is not a formality: a code 20 repair can involve flue temperature sensing and combustion safety, the very systems that decide whether the boiler vents its exhaust safely.
BC Wide Home Services Ltd has served Metro Vancouver since 1999 as an independent Technical Safety BC licensed contractor, gas contractor licence LGA0090068 and Class B gas licence CGA0028029. The technician at your door is our own licensed gas fitter. Where the work needs a permit, such as a boiler replacement or a change to gas piping or venting, we pull it and arrange the inspection.
Before you approve any code 20 repair, from us or anyone else, you should see the following.
Call (604) 473-9690 to book a diagnosis. If you smell gas or a carbon monoxide alarm sounds at any point, leave first and call FortisBC or 911 from outside, then call us.
- The cause named in plain language, with the branch identified: a refill fault or a sensor fault
- A written quote listing parts and labour before any work beyond diagnosis begins
- Confirmation of who holds the gas licence on the job and whether a permit applies
- After the repair, the readings that show the fix worked: pressure cold and hot, sensor values and a combustion check
- Notes on anything to keep an eye on, such as sludge, an ageing expansion tank or a valve close to the end of its life
More questions homeowners ask
What does error code 20 mean on a Lennox boiler?
Depending on context, it means either the boiler has reached its maximum number of automatic water refills, or a central-heating flow or flue NTC temperature sensor circuit is faulty. Confirm the meaning against the manual for your unit. In both cases the boiler has locked out to protect itself, and the cause needs to be found rather than reset away.
Can I reset Lennox boiler error code 20 myself?
Once, and only if your owner manual says a reset is allowed for this code. If the code comes back, stop resetting: on the refill branch each reset lets the boiler add more fresh water to a system that is losing it, and on the sensor branch the fault simply returns. At that point it is a call for a licensed technician.
Is it safe to run my Lennox boiler with code 20 showing?
The boiler will not fire while the code is active, which is the safe outcome. The risk comes from resetting it again and again to force it back on, which runs it outside the conditions its safeties expect and can mask a flue sensor problem. If you smell gas or a CO alarm sounds, leave and call FortisBC or 911 from outside.
Why does my Lennox boiler keep losing pressure and showing code 20?
Ongoing pressure loss almost always means water is leaving the system, through a leaking valve or fitting, a relief valve weeping because the expansion tank has lost its charge, an air vent spitting water, or occasionally a leak inside the boiler. The automatic fill keeps replacing that water until the control reaches its refill limit. A technician locates the loss by isolating and pressure-testing the loop rather than guessing.
How much does it cost to fix Lennox boiler code 20?
It depends entirely on which cause is behind it. A sensor, connector, relief valve or expansion tank is a routine repair, while a leak inside the boiler or in buried piping is a much larger job. We diagnose first and give you a written quote before any work beyond diagnosis.
Who fixes Lennox boilers near me in Greater Vancouver?
BC Wide services Lennox boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the Tri-Cities, the North Shore, New Westminster, Delta and Langley, with same-day visits where we can. We are an independent TSBC-licensed contractor, not a Lennox dealer or warranty centre. Call (604) 473-9690 to book.
- Lennox Boiler Code 150 — Fan or fan wiring fault | BC Wide
- Lennox Boiler Code 18 — Gas valve fault | BC Wide
- Lennox Boiler Code 19 — Automatic water refill enabled | BC Wide
- Lennox Boiler Code 321 — Domestic hot water NTC sensor fault | BC Wide
- Lennox Boiler Code 384 — False flame detected | BC Wide
- Lennox Boiler Code 385 — Under voltage (low supply voltage) | BC Wide
- Lennox Boiler Code 40 — Central Heating Return NTC fault | BC Wide
- Lennox Boiler Code 50 — Hot Water NTC fault (tank version) | BC Wide
- Lennox Boiler Code 53 — Flue obstruction – combustion off | BC Wide
- Lennox Boiler Code 55 — PCB requires calibration | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.