★ 4.7 Google rating · Serving Greater Vancouver since 1999
ServicesBrandsRebates ReviewsAboutContact 📞 Call (604) 473-9690

Lennox Furnace Code DS1 & DS2 alternating fast flash — Bad ground / low line voltage / igniter circuit | BC Wide

Error Codes, Furnace, Hvac

Lennox Furnace Code DS1 & DS2 alternating fast flash — Bad ground / low line voltage / igniter circuit | BC Wide — BC Wide Heating & Air Conditioning, Greater Vancouver
Home › Lennox Furnace Code DS1 & DS2 alternating fast flash — Bad ground / low line voltage / igniter circuit | BC Wide

Lennox Furnace Code DS1 & DS2 alternating fast flash — Bad ground / low line voltage / igniter circuit | BC Wide

Quick answer

On a Lennox furnace, DS1 and DS2 alternating in a fast flash points to one of three things: an improper main ground, incoming line voltage below 75 volts, or a broken igniter or open igniter circuit (confirm against the manual for your unit). The furnace will not light, so you lose heat until the cause is fixed. Check the breaker and the furnace service switch, then stop. Ground, voltage and igniter repairs are licensed work. Call BC Wide at (604) 473-9690.

If your Lennox furnace is showing DS1 & DS2 alternating fast flash (Bad ground / low line voltage / igniter circuit), here’s exactly what it means and what to do. This guide is part of our full Lennox furnace error code list.

Severity: Needs attention.

What DS1 & DS2 alternating fast flash means on a Lennox furnace

Indicates an improper main ground or line voltage below 75 volts, OR a broken igniter, OR an open igniter circuit.

Common causes

  • Improper or missing equipment ground
  • Low incoming line voltage (below 75 V)
  • Broken hot-surface igniter or open igniter circuit

What you can safely check first

  1. Check that the furnace breaker is fully on and not tripped
  2. If the whole home has low voltage / brown-out conditions, contact your utility
  3. Igniter and ground repairs require a technician

Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.

When to call a technician

This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.

BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.

Lennox furnace repair across Greater Vancouver

If a Lennox furnace showing DS1 & DS2 alternating fast flash won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.

Related Lennox furnace codes

Frequently asked questions

Is DS1 & DS2 alternating fast flash on a Lennox furnace serious?

It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lennox furnaces 7 days a week across Greater Vancouver.

How do I reset a Lennox furnace after DS1 & DS2 alternating fast flash?

You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.

Lennox furnace error code DS1 DS2 alternating fast flash: what it means for you

In plain words, the furnace control board ran its start-up checks before lighting the burners and found something it cannot trust. Either the electrical foundation the board depends on is not right (a solid equipment ground and enough incoming line voltage), or the part that actually lights the gas is not working (the hot-surface igniter and the wiring that feeds it). As this page describes it, the code covers an improper main ground or line voltage below 75 volts, or a broken igniter or open igniter circuit. Confirm that wording against the manual for your unit, because control boards differ between Lennox model generations. Until the cause is found, the board will not open the gas valve, so the burners stay off.

For you, that means no heat from the furnace. Your gas water heater is a separate appliance with its own controls, so hot water normally keeps working, unless the same electrical problem in the house is affecting other equipment too. On the safety side, the control is doing exactly what it was designed to do by refusing to light. The real risk is what happens next: repeated resets, jumper wires, removed panels or someone poking at live wiring. A poor ground is also a shock concern on its own, which is one more reason the cover panels stay on until a licensed technician arrives.

Why does the ground matter so much on a gas furnace? A modern furnace control uses the equipment ground as its reference point when it senses flame and checks its own circuits. If that ground path is loose, corroded or missing, the board’s readings stop making sense and it locks out rather than guess. Low line voltage starves the igniter so it cannot reach lighting temperature. An open igniter circuit means no current reaches the igniter at all. Three different causes, one outcome: the furnace will not attempt to light the gas.

  • The furnace was running fine yesterday and now the house is cold.
  • The thermostat says it is calling for heat, but nothing seems to happen at the furnace.
  • I hear the furnace start up, a click, and then it shuts down and a light on the board flashes quickly.
  • It started right after a power outage, a windstorm or some electrical work in the house.
  • The lights dim or flicker when the furnace or another large appliance starts.
  • It came back after I switched the power off and on, then quit again a few hours later.
  • I can see through the little window that there is no glow and no flame.

Lennox furnace error code DS1 DS2 alternating fast flash: likely causes, most common first

The order below reflects what installers commonly find on service calls for this kind of ignition and power fault, not a statistic. Every furnace is different, which is why the cause has to be proven with a meter before any part is replaced. For each cause, we list what an owner can safely look at and the point where it becomes licensed work.

  • 1. A worn or cracked hot-surface igniter. Igniters are a wear part. They heat to a glow on every single cycle, and over the seasons the element can crack or fail open. Owner-safe check: confirm the power and the thermostat call, and if your furnace has a viewing window, notice whether anything glows during a start attempt. Do not remove the panel to look. Licensed work: testing the igniter, replacing it with the correct part for your model, and confirming it is mounted in the right position relative to the burner.
  • 2. A loose, burnt or corroded connection in the igniter circuit. The igniter is fed through a plug at the control board, a harness and a connector near the burner. Heat cycling, vibration and the damp air in many Lower Mainland basements and crawlspaces can loosen or corrode those connections. Owner-safe check: none beyond the basics, because these connections sit behind panels. Licensed work: inspecting the harness and connectors for heat damage, testing continuity, and repairing or replacing the connection.
  • 3. A poor or missing equipment ground. A loose ground screw, a ground conductor that was never properly landed at the furnace, a renovation that left the furnace circuit without a sound ground, or a corroded ground at the panel can all trigger this code. Owner-safe check: think back to any recent electrical work, panel changes or basement renovations and mention them when you call. Licensed work: a gas technician checks and corrects the ground at the furnace; if the fault is in the house wiring or panel, a licensed electrician handles it.
  • 4. Low line voltage reaching the furnace. Causes include a loose or worn breaker, a loose neutral, a long or undersized circuit, a furnace sharing a circuit with other loads, or a utility-side brownout during a storm. Owner-safe check: make sure the breaker is fully on, notice whether lights dim around the house, and if neighbours are affected too, contact BC Hydro. Licensed work: measuring voltage at the furnace under load and tracing where it drops.
  • 5. A control board fault. Less common, but possible. A board that misreads a good ground or a good igniter will show the same code. This is the last thing we condemn, only after the igniter, wiring, ground and supply voltage all test good, because a control board is one of the more expensive parts on a gas furnace and replacing one on a guess is money wasted.
Likely causeWhat you might noticeOwner-safe checkWho fixes it
Worn or cracked igniterStart attempt but no glow, no flame, then lockoutConfirm power and thermostat call onlyLicensed gas technician
Loose or corroded igniter wiringIntermittent: works sometimes, fails other timesNone behind panels; note when it failsLicensed gas technician
Improper equipment groundCode appears after electrical work or renovationTell us about recent electrical changesGas technician at the furnace; electrician for house wiring
Low line voltageLights dim, fault during storms or heavy loadsBreaker fully on; check if neighbours are affectedUtility, electrician or gas technician depending on where the drop is
Control board faultCode persists after all other checks passNoneLicensed gas technician, after testing everything else

Can I reset a Lennox furnace flashing DS1 and DS2? Safe checks and where to stop

Yes, there are a few things a homeowner can safely do before calling, and none of them involve opening the furnace. Work through this short list in order and stop as soon as something looks wrong.

  • Check the furnace breaker in your electrical panel. It should be fully on, not sitting in the middle tripped position.
  • Check the furnace service switch, which usually looks like a light switch on or near the furnace. Make sure it is on.
  • Confirm the gas supply valve to the furnace is in the open position, with the handle in line with the pipe. Do not adjust anything else on the gas line.
  • Confirm the thermostat is set to heat and set a few degrees above room temperature, and replace its batteries if it uses them.
  • Confirm the furnace front door is fully seated in place. Do not remove it.
  • On a high-efficiency furnace, look outside at the intake and exhaust pipe terminals and clear away any snow, leaves, a nest or debris you can reach from the ground.
  • Look at the visible condensate drain line and trap from outside the cabinet for an obvious kink, disconnection or water on the floor.
  • Reset the furnace once, and only if your owner manual allows it, by switching the service switch off, waiting a moment, and switching it back on.

When the DS1 DS2 code becomes a licensed call, and the gas and CO safety line

If the code comes back after that one reset, stop. Repeated resets put extra stress on an igniter that is already weak, can hide an intermittent ground fault that shows up again on the coldest night, and push people toward shortcuts. Never remove panels, jumper or bypass a switch, tape down the door switch, or install parts bought online. Igniter, ground, wiring and control work on a gas appliance is restricted to licensed trades in BC, and the house wiring side belongs to a licensed electrician.

Call a licensed technician right away if the code returns, the breaker trips again, you notice a hot-plastic or burning smell, you see scorch marks or melted insulation, the lights dim every time the furnace starts, or you simply are not sure. A furnace that will not light is an inconvenience. A furnace that someone has forced to light can become a hazard.

Gas and carbon monoxide safety: if you smell gas, which is usually described as a rotten-egg smell, or your carbon monoxide alarm sounds, leave the home with everyone in it. Do not touch light switches, the thermostat or the furnace on your way out. Once you are outside, call FortisBC or 911. Do not go back inside until you are told it is safe. Every home with a gas furnace should have working CO alarms near the sleeping areas and on each level, tested regularly.

How our Lennox furnace repair visit works, step by step

A correct repair for this code is about measurement, not guessing. Here is what a visit from BC Wide looks like, and what you should expect to see in writing at the end.

  • 1. Phone triage. We ask what the board is flashing, when it started, and whether there was an outage, storm or electrical work. For no-heat calls we offer same-day where we can, and we tell you honestly when it is not possible. We never promise a guaranteed arrival window.
  • 2. Safety first on arrival. The technician checks for any gas smell, takes a carbon monoxide reading around the furnace and looks over the venting before touching the appliance.
  • 3. Read and confirm the code. We read the flashing pattern, confirm it against the manual for your unit, and check any stored fault history the control keeps.
  • 4. Measure line voltage under load. With a calibrated meter we measure the supply at the furnace at rest and again while the inducer and blower are running, because a weak connection often only shows up under load.
  • 5. Test the ground path. We check the equipment ground at the furnace and confirm the supply wiring is landed correctly.
  • 6. Test the igniter circuit. We test the igniter itself and the continuity of the circuit from the board to the igniter, and inspect the plug, harness and connectors for heat damage or corrosion.
  • 7. Explain and quote. We show you what we found in plain words and give you a written quote before any work beyond the diagnosis. If the problem is in the house wiring or panel, we tell you in writing that it needs a licensed electrician.
  • 8. Repair with the correct part. The parts most often involved with this code are the hot-surface igniter, an igniter harness or connector, the ground connection, and occasionally the control board. Parts are matched to your model.
  • 9. Test the safeties. We run several full heat cycles and confirm the ignition sequence, flame, pressure switch, limit and rollout safeties, venting and combustion, and on a high-efficiency unit the condensate drain.
  • 10. Paperwork. You receive a written invoice listing the fault found, the measurements taken, the parts replaced and any recommendations.

Repair or replace an older Lennox furnace with a DS1 DS2 fault?

In most cases this code leads to a repair, not a replacement. A worn igniter, a corroded connector or a loose ground is not a reason to retire a furnace that is otherwise sound. The decision changes when the DS1 DS2 fault is one of several problems arriving at once on an older unit.

If replacement does make sense, BC Wide leads with dual fuel: a heat pump paired with a gas furnace that stays in place as backup for cold snaps. The heat pump handles the mild, wet shoulder seasons that make up much of a Metro Vancouver winter, and the gas furnace carries the load when temperatures drop. We put both options, repair and replacement, in a written quote so you can compare them side by side. Replacement involves a gas permit through Technical Safety BC and an inspection, which we arrange.

About trust: BC Wide Home Services Ltd is an independent Technical Safety BC licensed gas contractor (licence LGA0090068, Class B gas CGA0028029) serving Metro Vancouver since 1999. Our work is done by our own licensed gas fitters. We are not a Lennox dealer or a manufacturer warranty centre. If your furnace may still be under a manufacturer warranty, check your registration and warranty terms before the repair, and we will tell you what we find so you can follow the manufacturer’s process.

  • Repair usually wins when the heat exchanger, inducer and blower are sound and the fault traces to one worn part or connection.
  • Replacement becomes worth discussing when the furnace is near the end of its expected service life, has needed several major parts recently, or has heat exchanger or venting concerns.
  • Parts availability matters: on older Lennox models, some original control parts can be harder to source, and that can affect both timing and the repair decision.
  • Comfort complaints such as uneven rooms, noisy operation or short cycling are worth raising during the same visit, because they change the value of a repair.

Lennox furnace DS1 DS2 repair in Vancouver, Burnaby, Surrey, Richmond, Coquitlam and across Greater Vancouver

Our mild, wet coastal climate shapes how this fault shows up. Furnaces here run long, low-demand heating seasons, so igniters rack up a lot of cycles. Damp basements, crawlspaces and garages encourage corrosion on connectors and ground terminals. Winter windstorms bring outages and voltage dips, and it is common for owners to notice this code the morning after the power flickered.

In Vancouver, many older houses and basement suites have electrical systems that were added to over decades, which is exactly where a ground or circuit problem can hide. Burnaby and New Westminster mix older homes with townhouses, where furnaces often sit in tight closets that make ventilation and access part of the job. Surrey, Langley and Delta include many newer subdivisions alongside older properties, and both bring their own wiring and venting layouts. In Richmond, homes are generally built without full basements, so furnaces are often in a utility closet, a crawlspace or the garage. Coquitlam and the rest of the Tri-Cities, Port Coquitlam and Port Moody, have plenty of hillside homes with long runs from the panel to the furnace. On the North Shore, in North Vancouver and West Vancouver, heavier rainfall and nearby foliage mean outdoor intake and exhaust terminals are worth checking during the visit.

Brands we service for gas furnace ignition and control faults include Lennox, Carrier, Bryant, Trane, American Standard, Goodman, Amana, Rheem, Ruud, York, Daikin, KeepRite and Napoleon. These are brands we service as an independent contractor, not brands we are certified by. If your Lennox furnace is flashing DS1 and DS2 anywhere in Greater Vancouver, call BC Wide at (604) 473-9690 and we will book the earliest visit we can.

More questions homeowners ask

What does DS1 and DS2 alternating fast flash mean on a Lennox furnace?

It means the control has found an improper main ground, line voltage below 75 volts, or a broken igniter or open igniter circuit, and it will not light the burners until that is corrected. Confirm the meaning against the manual for your unit, since boards vary by model generation. A licensed technician uses a meter to find out which of the three it is.

Can I reset my Lennox furnace when DS1 and DS2 are flashing?

You can reset it once, and only if your owner manual allows it, by turning the service switch off and back on. If the code returns, stop and call a licensed technician. Repeated resets stress a weak igniter and can hide an intermittent ground fault.

Is it safe to run my Lennox furnace with the DS1 DS2 code?

The furnace will not light with this code active, and you should not try to force it. Never jumper, bypass or open the panels to get it running. If you smell gas or your CO alarm sounds, leave the home and call FortisBC or 911 from outside.

Can a power outage cause a Lennox furnace to flash DS1 and DS2?

An outage or brownout can be the moment the code appears, because low voltage or a surge can expose an igniter or connection that was already weak. If the code clears after power is fully restored and one reset, keep an eye on it. If it returns, have the furnace tested, and contact BC Hydro if your neighbours also have low power.

Do I need an electrician or a gas fitter for this Lennox furnace code?

Start with a licensed gas technician, because the igniter, igniter wiring and furnace-side ground are part of the gas appliance. If testing shows the problem is in the house wiring, breaker or panel, that work belongs to a licensed electrician. We tell you in writing which side the fault is on.

Can you fix a Lennox furnace DS1 DS2 code the same day near me in Greater Vancouver?

Same-day where we can, across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. It depends on the schedule that day and whether the correct part is in stock for your model. Call (604) 473-9690 and we will give you an honest answer about timing.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a furnace be serviced?
Annual servicing is recommended for gas furnaces, ideally before the start of the heating season in September or October. Service includes burner cleaning, heat exchanger inspection, ignition check, blower motor cleaning, gas pressure adjustment and a full safety test for carbon-monoxide leaks.
How long does a furnace last in Vancouver's climate?
High-efficiency gas furnaces typically last 15–20 years with annual maintenance. Vancouver's mild climate means lower run-times than colder Canadian cities, which extends life — but salt-air corrosion near the coast and high humidity can shorten it.
Why is my furnace blowing cold air?
Common causes are a thermostat set to "on" instead of "auto", a tripped flame sensor, a clogged condensate drain shutting down a high-efficiency unit, low gas pressure, or a failed ignitor. Most are repairable in a single service visit.
How much does a new furnace cost in Vancouver?
A typical residential high-efficiency gas furnace in Metro Vancouver costs $4,500–$8,500 installed depending on size, brand and venting requirements. Variable-speed and modulating models are at the upper end.
What is the most reliable furnace brand?
In our experience servicing Vancouver homes since 1999, Carrier, Lennox, Bryant and York have produced the most reliable mid-to-high-efficiency furnaces with the best parts availability. Goodman and Rheem offer strong value at lower price points.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote