Lennox Furnace Code DS1 & DS2 alternating slow flash — Watchguard — failed to ignite | BC Wide

Error Codes, Furnace, Hvac

Lennox Furnace Code DS1 & DS2 alternating slow flash — Watchguard — failed to ignite | BC Wide — BC Wide Heating & Air Conditioning, Greater Vancouver
Home › Lennox Furnace Code DS1 & DS2 alternating slow flash — Watchguard — failed to ignite | BC Wide

Lennox Furnace Code DS1 & DS2 alternating slow flash — Watchguard — failed to ignite | BC Wide

Quick answer

On a Lennox furnace, DS1 and DS2 flashing alternately and slowly is a Watchguard lockout: the burners failed to ignite within the allowed number of trials, so the control has stopped trying and will retry on its own after its timed reset period. Confirm that meaning against the manual for your unit. Check that the thermostat is calling for heat, the furnace power switch is on, the gas supply valve is open and the outside vent pipes are clear. If it locks out again, stop resetting and book a licensed gas technician.

If your Lennox furnace is showing DS1 & DS2 alternating slow flash (Watchguard — failed to ignite), here’s exactly what it means and what to do. This guide is part of our full Lennox furnace error code list.

Severity: Critical — likely no heat / lockout.

What DS1 & DS2 alternating slow flash means on a Lennox furnace

Watchguard lockout: the burners failed to ignite within the allowed number of trials. After a 60-minute reset period the control will attempt ignition again.

Common causes

  • No or insufficient gas flow
  • Igniter not lighting the burner
  • Dirty or failed flame sensor
  • Dirty filter / restricted airflow
  • Blocked condensate drain or cracked hoses

What you can safely check first

  1. Check and replace a dirty air filter
  2. Confirm other gas appliances are working (so you know gas supply is on) — but do not touch the furnace gas valve or burners
  3. Clear any vent blockage outside and confirm the condensate drain is flowing

Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.

When to call a technician

This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.

BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.

Lennox furnace repair across Greater Vancouver

If a Lennox furnace showing DS1 & DS2 alternating slow flash won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.

Related Lennox furnace codes

Frequently asked questions

Is DS1 & DS2 alternating slow flash on a Lennox furnace serious?

It’s a lockout/safety code — the furnace has shut down and needs prompt diagnosis. BC Wide repairs Lennox furnaces 7 days a week across Greater Vancouver.

How do I reset a Lennox furnace after DS1 & DS2 alternating slow flash?

You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.

Lennox furnace error code DS1 DS2 alternating slow flash: what it means for you at home

In plain terms, your furnace tried to light and could not. Every heating call follows the same chain: the inducer fan purges the heat exchanger, the pressure switch proves the vent path is open, the igniter heats up, the gas valve opens, and the flame sensor has a few seconds to prove there is a flame. When that chain breaks more times than the control allows, the board stops trying and flashes DS1 and DS2 alternately and slowly. That pattern is the Watchguard failed-to-ignite lockout described at the top of this page. Confirm the meaning against the manual for your unit, because Lennox control boards differ between furnace generations.

What it means for your home: no heat from the furnace until the cause is found, or until the control retries and happens to succeed. The blower may keep running for a while after the failed attempts, which is normal. A furnace lockout does not affect a separate gas water heater, so you should still have hot water. If the water heater, the gas range or a gas fireplace has also stopped working, that is a strong clue the problem is the gas supply to the house rather than the furnace itself.

On safety: the lockout is the control doing its job. It refused to keep sending gas to burners that would not light. The lockout itself is not a hazard. Forcing the furnace to retry over and over by cycling the power is where trouble starts, because repeated failed trials and late, rough ignitions are hard on the burners, igniter and venting, and they can mask a gas-pressure or venting fault that a technician needs to find.

This is how owners usually describe the problem when they call us:

  • The house is getting cold, the thermostat says it is calling for heat, but no warm air comes out of the registers.
  • The furnace starts, a fan spins up and you hear a click or two, then it goes quiet without the burners lighting.
  • You can see an orange glow through the small sight window that fades away without the soft whoosh of the burners.
  • The burners light for a moment and then shut off, and this repeats a few times before the furnace goes silent.
  • The furnace works after you switch it off and on, then locks out again later the same day or overnight.
  • It only seems to happen on the coldest, wettest or windiest nights, or after a long run time.

Lennox furnace error code DS1 DS2 alternating slow flash: likely causes, most common first, and what you can check

These are the causes we find most often behind a Watchguard failed-to-ignite lockout on the Lennox furnaces we service around Metro Vancouver, listed roughly from most to least common in our experience. The last two columns separate what an owner can look at safely, without opening any panel, from the point where it becomes work for a licensed gas fitter.

  • Thermostat first: set it to Heat, a few degrees above room temperature, and replace its batteries if it uses them.
  • Power: the furnace service switch, which looks like a light switch on or near the furnace, is on, and the breaker has not tripped. Do not reset a tripped breaker more than once.
  • Gas supply valve: the handle on the gas pipe beside the furnace should be parallel to the pipe. If it was turned off and you do not know why, leave it off and call us rather than turning it on.
  • One reset only, and only if your owner manual describes one: switch the furnace off, wait a short while, switch it back on and watch a single ignition attempt. If DS1 and DS2 come back, stop.
  • Outside terminals: clear snow, leaves or debris from the intake and exhaust pipes by hand, without pulling or twisting the pipes.
  • Condensate: make sure the visible drain line is not kinked and that any condensate pump is plugged in and not overflowing.
  • Never remove the burner door, touch the gas valve on the furnace, jumper or bypass any switch, or keep resetting the furnace.
#Likely causeWhat you might noticeOwner-safe checkBecomes a licensed call when
1Dirty or failing flame sensorBurners light briefly, then shut off, several times before the lockoutNone inside the cabinet. Note how long the flame stays lit and tell the technicianAlways. Cleaning and testing the sensor means opening the burner compartment and measuring flame signal with a meter
2Igniter not lighting the burnerFan runs, but there is no glow or only a weak glow through the sight window, and no flameLook through the sight window without removing any panel and note what you seeAlways. Igniters are fragile and testing them involves live voltage inside the furnace
3No gas or not enough gas reaching the burnersIgniter glows but the burners never light. Other gas appliances may also be outConfirm the furnace gas supply valve handle sits in line with the pipe, and check whether the range, water heater or fireplace still lightRight away if other appliances are out, if you smell gas, or if the valve was already open. Gas pressure testing is licensed work
4Blocked intake or exhaust terminalLockouts on windy, snowy or leaf-heavy days. The fan runs, then everything stopsFrom outside, check the two plastic pipes where they leave the wall or roof and remove snow, leaves, ice or a nest by handIf the pipes are clear and it keeps locking out, or any vent pipe is cracked, sagging or separated
5Blocked condensate drain or cracked hosesWater near the furnace, gurgling sounds, lockouts after long run timesLook at the visible drain line, floor drain and any condensate pump for a kink, a clog or water on the floorIf there is water inside the furnace, the trap needs cleaning, or a hose inside the cabinet looks cracked
6Dirty filter or restricted airflowWeak airflow, several closed registers, the furnace cycling oddlyReplace a dirty filter with the correct size and open closed supply registers and return grillesIf the filter is clean, airflow is still poor and the lockout continues

Is it safe to keep resetting a Lennox furnace with DS1 and DS2 flashing? When it becomes a licensed gas call

No. A single reset, where your owner manual allows it, tells you whether the fault was a one-off, such as a brief gas interruption or a snow-blocked vent you have since cleared. A second lockout tells you there is a real fault, and every further reset adds more failed ignition attempts to a system that is already warning you. Frequent resets also erase the pattern a technician needs to see, such as a lockout that only happens after a long run, only in wind, or only on the first call of the morning.

It becomes a licensed call when the lockout returns after one reset; when the gas supply valve was already open and your other gas appliances work; when you can see the igniter glow but the burners never light; when the burners light and then drop out; when you see scorching, soot or discoloured wiring near the burner area; when there is water inside the cabinet; when any vent pipe is damaged or disconnected; or simply when you are not comfortable doing the checks above. In British Columbia, gas work, including anything on the gas valve, burners, manifold, venting connections and gas piping, is restricted to licensed gas fitters, and most electrical work inside the furnace is restricted to qualified trades as well.

Gas and carbon monoxide safety: if you smell gas, the rotten-egg odour added to natural gas, get everyone out of the house right away. Do not switch lights or appliances on or off, do not use a phone inside, and do not look for the leak. Once you are outside and well away from the house, call the FortisBC emergency line or 911. If a carbon monoxide alarm sounds, or anyone has a headache, nausea, dizziness or drowsiness that eases when they go outside, get everyone into fresh air and call 911 from outside. Every home with a gas furnace should have working CO alarms near sleeping areas and on each level; test them whenever you change the furnace filter.

Emergency and same-day timing: a no-heat lockout during a cold snap is a priority call for us. We offer same-day service where we can, depending on the day’s bookings and where you are in the region, but we will not promise a guaranteed arrival window. When you call (604) 473-9690, tell us the code, whether your other gas appliances work, and whether anyone in the house is especially vulnerable to the cold, so we can triage honestly and tell you how to stay safe and warm until we arrive.

How our Lennox furnace repair visit works, step by step

A failed-to-ignite lockout has several possible causes, and the fastest route to a lasting repair is measuring each link in the ignition chain instead of swapping parts until the code goes away. This is what a visit from one of our licensed gas fitters looks like.

  • Step 1, booking and triage: we ask about the code, when it started, whether lockouts follow wind, rain or long run times, and whether other gas appliances work. That tells the technician what to expect and what to bring.
  • Step 2, safety first on arrival: the technician checks for gas odour and carbon monoxide around the furnace and venting before anything else, then reads the current code and any fault history the control stores, where the board keeps one.
  • Step 3, watch a full ignition sequence: we watch the furnace go through a heating call from inducer start to pressure switch, igniter, gas valve and flame proving. Where the sequence stops tells us which part of the chain to test.
  • Step 4, measure with the right meters: depending on what we see, that means a multimeter on igniter resistance and supply voltage, a microamp reading of flame signal, a manometer on inlet and manifold gas pressure, a check of the pressure switch and vent path, and a combustion analyzer on the flue gases once the furnace is running.
  • Step 5, the parts most often involved: in general terms, Watchguard lockouts trace back to the flame sensor, the hot surface igniter, the gas supply or gas pressure, the pressure switch and its tubing, the inducer, the condensate trap and hoses, or the venting, and less often to the gas valve or the control board. We do not replace parts by trial and error.
  • Step 6, written quote before any work beyond diagnosis: anything that needs a new part or extra labour gets a written quote first, describing the part, why it failed and the work involved, and you decide whether to go ahead.
  • Step 7, repair and test the safeties: after the repair we run several complete heating cycles, confirm the flame proves reliably, check that the pressure switch, high-limit and rollout safeties respond as they should, confirm gas pressure and combustion readings sit within the manufacturer-published range for your model, and check for carbon monoxide at the furnace and in the living space.
  • Step 8, what you receive in writing: a record of the code, the readings taken, the cause we found, the parts replaced and anything we recommend keeping an eye on. If we find a condition we will not leave running, we tell you in writing and explain why.

Should I repair or replace an older Lennox furnace that keeps failing to ignite?

Most DS1 and DS2 lockouts are repairs, not replacements. A flame sensor, an igniter, a plugged condensate trap or a vent problem is a normal service item on any condensing gas furnace, and fixing it properly gives you back a reliable furnace. Replacement only enters the conversation when this repair is the latest of several, or when the diagnosis turns up something that is not worth fixing on an ageing unit.

These are the factors we weigh with you, honestly and in writing:

  • The age and service history of the furnace, and whether it has had repeat lockouts or several major parts replaced already.
  • The condition of the heat exchanger and cabinet: rust, corrosion from past condensate leaks, or signs of overheating change the picture.
  • Whether the part needed is one of the more expensive ones, such as the control board, inducer or gas valve, and whether it is still readily available for your model.
  • Whether the furnace is correctly sized and vented for the house, or has been short-cycling and running hot for years.
  • Comfort complaints you already live with, such as noisy ducts, cold rooms or uneven temperatures between floors.
  • Your plans: how long you expect to stay in the home, and whether you want to add cooling.

Lennox DS1 DS2 furnace repair near me: Greater Vancouver coverage, housing stock and who does the work

If replacement does make sense, our default recommendation for most Metro Vancouver homes is dual fuel: a heat pump that handles cooling and most of the heating season, paired with a high-efficiency gas furnace that takes over during cold snaps. Our mild coastal winters suit a heat pump for much of the year, and keeping the gas furnace as backup means you are not relying on the heat pump on the genuinely cold nights. We can quote a like-for-like furnace replacement and a dual-fuel option side by side so you can compare. Every option gets a written quote after we have seen the house, the venting and the gas line, and a furnace replacement in BC needs a gas permit and inspection, which we handle as the licensed contractor.

We service Lennox furnaces, and the same failed-to-ignite fault on other brands, across Greater Vancouver: Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities including Port Coquitlam and Port Moody, the North Shore, New Westminster, Delta and Langley. Each area has its own mix of housing, and the housing often shapes why a furnace fails to ignite.

  • Vancouver and Burnaby: many older detached houses where the furnace has been replaced once or twice in the same mechanical room, sometimes on gas lines and venting first laid out for an earlier appliance. Tight basement furnace rooms make airflow and service access part of the diagnosis.
  • Surrey, Langley and Delta: a broad mix of older ranchers and newer subdivisions. In many newer homes the furnace sits in an attic, crawlspace or garage, where condensate lines can sag or freeze and side-wall vent terminals take the weather.
  • Richmond: low-lying ground and many furnaces in garages or crawlspaces, so condensate drainage and condensate pump condition come up often.
  • Coquitlam, Port Coquitlam and Port Moody: hillside homes and townhouses where wind exposure on vent terminals and long condensate runs are common contributors to lockouts.
  • North Shore: higher elevations see more snow and wind than most of the region, so intake and exhaust terminals blocked by snow or ice are a real cause of winter lockouts.
  • New Westminster: plenty of older homes and townhouses with compact mechanical spaces, where furnaces are often tucked into closets with limited return air.

More questions homeowners ask

What does DS1 DS2 alternating slow flash mean on a Lennox furnace?

It indicates a Watchguard lockout: the burners failed to ignite within the allowed number of trials, so the control stopped trying and will retry on its own after its timed reset period. Confirm the meaning against the manual for your unit, since Lennox control boards vary between generations. It means no heat until the cause is found, but the lockout itself is a safety response, not a hazard.

Can I reset a Lennox furnace with DS1 and DS2 flashing?

Once, and only if your owner manual describes a reset. Switch the furnace off at its service switch, wait a short while, switch it back on and watch one ignition attempt. If DS1 and DS2 come back, stop resetting and call a licensed technician, because repeated resets add failed ignition attempts and can hide a gas or venting fault.

Is it safe to run my Lennox furnace after a Watchguard lockout?

If the furnace relights and runs normally after a single reset, with no gas smell and no carbon monoxide alarm, it is generally reasonable to use it while you book a service visit. If it locks out again, leave it off and have it diagnosed. If you smell gas or a CO alarm sounds, leave the house and call FortisBC or 911 from outside.

Why does my Lennox furnace fail to ignite only on cold or windy nights?

Weather-linked lockouts usually point to the vent path or the condensate system: wind can upset the pressure switch on exposed vent terminals, snow and ice can partly block the intake and exhaust pipes, and condensate lines in cold spaces can freeze. A weak flame sensor or igniter also tends to give up first when the furnace is working hardest. Clear the outside terminals by hand and book a technician if it repeats.

Can you fix a Lennox DS1 DS2 code the same day in Greater Vancouver?

Often, yes. We offer same-day service where we can, depending on bookings and your location, and no-heat calls in cold weather get priority, but we do not promise a guaranteed arrival window. If a specific part has to be ordered, we tell you how long it should take and make sure the furnace is left in a safe state in the meantime. Call (604) 473-9690 to book.

Does BC Wide repair Lennox furnaces under warranty?

We are an independent TSBC-licensed contractor, licence LGA0090068 and Class B gas licence CGA0028029, not a Lennox authorized dealer or warranty centre. We diagnose and repair Lennox furnaces like the other brands we service, including Carrier, Bryant, Trane, American Standard, Goodman, Amana, Rheem, Ruud, York, Daikin, KeepRite and Napoleon, and we give you a written record of the fault and the readings. If your furnace may still be under a manufacturer warranty, check the terms with the manufacturer or your original installer before parts are replaced.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a furnace be serviced?
Annual servicing is recommended for gas furnaces, ideally before the start of the heating season in September or October. Service includes burner cleaning, heat exchanger inspection, ignition check, blower motor cleaning, gas pressure adjustment and a full safety test for carbon-monoxide leaks.
How long does a furnace last in Vancouver's climate?
High-efficiency gas furnaces typically last 15–20 years with annual maintenance. Vancouver's mild climate means lower run-times than colder Canadian cities, which extends life — but salt-air corrosion near the coast and high humidity can shorten it.
Why is my furnace blowing cold air?
Common causes are a thermostat set to "on" instead of "auto", a tripped flame sensor, a clogged condensate drain shutting down a high-efficiency unit, low gas pressure, or a failed ignitor. Most are repairable in a single service visit.
How much does a new furnace cost in Vancouver?
A typical residential high-efficiency gas furnace in Metro Vancouver costs $4,500–$8,500 installed depending on size, brand and venting requirements. Variable-speed and modulating models are at the upper end.
What is the most reliable furnace brand?
In our experience servicing Vancouver homes since 1999, Carrier, Lennox, Bryant and York have produced the most reliable mid-to-high-efficiency furnaces with the best parts availability. Goodman and Rheem offer strong value at lower price points.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.