On a Lennox furnace, DS1 OFF with DS2 slow flash points to the pressure switch: it is open, or keeps opening during a heat call, which the control reads as a blocked intake or exhaust vent, a blocked condensate line, or a switch that was closed before the combustion air blower started (confirm against the manual for your unit). The furnace stops heating to protect you. Clear snow, leaves or nests from the outside vent terminals and check the condensate drain. If the code returns, call a licensed gas technician at (604) 473-9690.
If your Lennox furnace is showing DS1 OFF, DS2 slow flash (Pressure switch open / vent blocked), here’s exactly what it means and what to do. This guide is part of our full Lennox furnace error code list.
Severity: Needs attention.
What DS1 OFF, DS2 slow flash means on a Lennox furnace
The pressure switch is open or has opened 5 times during a single heat call. Also indicates a blocked inlet/exhaust vent, a blocked condensate line, or a pressure switch that was closed before the combustion air blower started.
Common causes
- Blocked intake or exhaust vent (snow, ice, leaves, nests, debris outside)
- Blocked or full condensate drain line
- Pressure switch or inducer fault
- Cracked or disconnected pressure tubing
What you can safely check first
- Go outside and clear the intake and exhaust vent terminations of snow, ice, leaves, or debris
- Check that the condensate drain line is not clogged or kinked and that the drain is flowing
- Check the filter and registers for airflow restriction
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox furnace repair across Greater Vancouver
If a Lennox furnace showing DS1 OFF, DS2 slow flash won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox furnace codes
- Lennox furnace DS1 & DS2 simultaneous slow flash — Normal power / standby
- Lennox furnace DS1 & DS2 simultaneous fast flash — Normal heat call
- Lennox furnace DS1 slow flash, DS2 steady ON — Primary/secondary limit open
- Lennox furnace DS1 & DS2 alternating slow flash — Watchguard — failed to ignite
- Lennox furnace DS1 slow flash, DS2 OFF — Flame sensed without gas valve energized
- Lennox furnace DS1 steady ON, DS2 slow flash — Rollout switch open / connector loose
Frequently asked questions
Is DS1 OFF, DS2 slow flash on a Lennox furnace serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lennox furnaces 7 days a week across Greater Vancouver.
How do I reset a Lennox furnace after DS1 OFF, DS2 slow flash?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox furnace error code DS1 OFF DS2 slow flash: what it means for you
In plain terms, the furnace is refusing to light, or refusing to keep running, because it cannot prove that combustion gases have a clear path out of the house. Before the burners are allowed to fire, the inducer (the small fan mounted on the burner box) starts, pulls air through the heat exchanger and the vent, and that suction closes the pressure switch. If the switch never closes, opens partway through the cycle, or was already closed before the inducer started, the control board stops the sequence and shows this pattern on its two diagnostic lights. Confirm the exact meaning against the manual for your unit, because Lennox control boards differ between generations.
For your household, that comes down to three things. Heat: the house will slowly cool, and the furnace may try, fail, wait and try again, so you hear the inducer start and stop without the burners lighting, or the burners light briefly and shut down. Hot water: a furnace does not heat your domestic water, so a separate tank or tankless water heater should keep working; if both stop at the same time, that points to something shared, such as the gas supply or a common vent, and it is worth mentioning when you call. Safety: the pressure switch is doing its job. It is a safety device, and this code is the furnace protecting you from running with a vent that may not be clearing combustion gases properly.
Here is how homeowners usually describe it when they call us:
- The thermostat is calling for heat, but the registers blow cold air or nothing at all.
- A humming or whirring fan starts, runs for a short while, then stops, and no flame ever appears.
- The furnace runs for a few minutes, shuts off, then tries again later on its own.
- A gurgling or sloshing sound comes from inside the cabinet or from the drain hose.
- There is water around the base of the furnace or a drip near the condensate trap.
- The problem shows up during heavy rain, strong wind, snow or a hard frost and clears afterward.
- There is a whistling or fluttering sound at the plastic vent pipes outside the house.
Lennox furnace error code DS1 OFF DS2 slow flash: likely causes, most common first
This is roughly the order we find them on Metro Vancouver service calls, from most to least common. Most of the time the pressure switch itself is not broken; it is accurately reporting a real airflow or drainage problem upstream of it. That is why replacing the switch alone, without finding out why it opened, so often brings the same code back within days.
Two causes deserve a special mention for coastal homes. Wind blowing across a sidewall terminal can change the pressure the switch sees and briefly open it, and long stretches of heavy rain can push water into a vent that is not pitched correctly, where it pools and restricts flow. Both produce a code that seems to come and go with the weather. A short note of when the code appears (time of day, the weather, how long the furnace had been running) is one of the most useful things you can hand the technician.
| Likely cause (most common first) | What the owner usually notices | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Blocked outside intake or exhaust terminal | Code appears after snow or frost, after a windy day with blowing leaves, or in spring when birds or wasps nest in the pipes | Look at both pipe ends outside and gently clear debris you can reach safely from the ground | If the terminals are clear and the code returns, or the pipes are cracked, loose, crushed or too close to grade |
| 2. Blocked or backed-up condensate drain or trap | Gurgling, water near the furnace, code worse after long run times on cold days | Check the visible drain hose is not kinked, crushed or sitting in standing water at the floor drain or pump | If the trap inside the cabinet needs cleaning, the condensate pump has failed, or there is water inside the burner area |
| 3. Cracked, kinked, loose or water-filled pressure tubing | Intermittent code that comes and goes with no obvious pattern | Look only; do not pull, blow into or reconnect the tubing | Always; the technician inspects, clears or replaces the tubing and checks the port it connects to |
| 4. Venting problem inside the house | Code started after a renovation, a new ceiling, or a moved furnace; vent pipe joints sag, drip or look separated | Look for visibly disconnected or sagging vent pipe without touching it | Always; vent slope, joints, supports, length and fittings are gas-code items |
| 5. Weak or failing inducer motor | Louder rattling, grinding or humming fan, slower start, code worse on cold mornings | None; listen and describe the sound to the technician | Always; the inducer is tested electrically and for the suction it actually produces |
| 6. Faulty pressure switch | Code persists even though venting and drain are clear | None | Always; the switch is tested with a manometer before it is condemned and replaced with the correct rated part, never bypassed |
| 7. Restriction inside the furnace, such as the collector box or the condensing side of the heat exchanger | Repeated code after the simpler causes are ruled out, sometimes with water reaching the inducer | None | Always; this means opening sealed combustion components |
What can I check myself before calling, and what should I leave alone?
Work through these in order. Each one is safe for a homeowner, needs no tools, and does not involve opening the furnace. If any step turns up something you are unsure about, stop there and call.
Do not open the burner compartment, remove the inducer, pull or blow into the pressure tubing, jumper or bypass the pressure switch, tape over vent joints, or keep cycling the power. A bypassed pressure switch lets the furnace fire with no proof that the vent is clear, and that is exactly how carbon monoxide ends up in living space. Gas work, gas venting and most electrical work on a furnace are legally restricted to licensed trades in BC, so anything past the checks above is a job for a licensed technician.
Gas and carbon monoxide safety: if you smell gas (a rotten-egg odour) or a carbon monoxide alarm sounds, do not touch light switches, the thermostat or the furnace. Get everyone, including pets, out of the home and call FortisBC or 911 from outside. Every home with a gas furnace should have working CO alarms near the sleeping areas, tested regularly and replaced when they reach the end of their service life.
- Power: confirm the furnace service switch (it looks like a light switch on or near the furnace) is on and that the breaker has not tripped. Do not take the door panels off to look inside.
- Gas supply: confirm the manual gas shut-off valve at the furnace is open, with the handle running in line with the pipe. If your other gas appliances work normally, the gas supply is probably fine.
- Thermostat: make sure it is set to heat, set a few degrees above room temperature, and has fresh batteries if it uses them.
- Filter: a clogged filter does not usually cause this particular code by itself, but replace it if it is dirty, since a technician will ask.
- Outside terminals: find the two plastic pipes where the furnace vents through the wall or roof. Clear snow, ice, leaves, cobwebs or nesting material you can safely reach from the ground. Do not climb onto a roof and do not push anything down the pipes.
- Condensate drain: follow the visible drain hose from the furnace to the floor drain or condensate pump. Make sure it is not kinked, pinched under a storage box or sitting under water. If a condensate pump is full and not running, note that for the technician.
- Reset once, and only if your owner’s manual says a reset is allowed: turn the furnace service switch off, wait the time the manual states, then turn it back on. If the code returns, stop. Repeated resets can hide a safety problem and add wear to the ignition parts.
How our repair visit works for a Lennox DS1 OFF, DS2 slow flash fault
Here is what a correct diagnosis looks like from our side, so you know what to expect at the door and what you should see in writing. We aim for same-day where we can. During a cold snap, when many no-heat calls arrive at once, we triage and tell you honestly when we can be there; we do not promise a guaranteed arrival window.
Parts most often involved, in general terms: pressure tubing, condensate trap and drain components, the condensate pump, the pressure switch itself, the inducer motor, and sections of vent pipe or terminal fittings. Tubing, trap and drain work is usually the lighter end of the job. An inducer motor or a vent reroute is a bigger job, and a control board is one of the more expensive parts on a gas furnace, which is why we prove a board has failed before anyone recommends replacing one.
- Phone triage: we ask for the code, when it started, what the weather was doing when it appeared, and whether anyone has smelled gas or heard a CO alarm. A gas smell or an alarm goes to FortisBC or 911 first, not to us.
- Read and confirm the code: the technician reads the diagnostic lights and any stored fault history the control keeps, and confirms the pattern against the Lennox documentation for your model.
- Measure, do not guess: with a manometer on the pressure circuit, we measure the actual suction the inducer produces and compare it with the rating printed on the switch. That one test separates a venting or drain problem from a weak inducer or a faulty switch.
- Inspect the whole vent run: intake and exhaust from the furnace to the terminals, including slope, joints, supports, clearances at the terminal, and any length or fittings added during a past renovation.
- Clear and flow-test the condensate system: the trap, internal hoses, the drain line and any condensate pump, refilled and checked for proper drainage.
- Electrical checks: inducer motor voltage and current draw, switch operation at rest and while running, and the wiring and connectors in the pressure circuit.
- Written quote before any work beyond diagnosis: you see what needs doing, which part, and why, in writing, before we proceed. Nothing gets replaced on a hunch.
- Repair, then test the safeties: after the repair we run full heat cycles and confirm the pressure switch, flame sensing, high limit and rollout safeties all behave as they should, and check for combustion spillage.
- Walk you through it: you get the readings, what failed and why, and what to watch for so you can spot the early signs if it ever comes back.
Should I repair or replace an older Lennox furnace that keeps showing this code?
Most DS1 OFF, DS2 slow flash faults are repairs, not replacements. A blocked terminal, a clogged trap, cracked tubing or a worn pressure switch is a modest fix on almost any furnace. The repair-or-replace question only becomes real when the cause sits deeper in the equipment or the venting, on a furnace that is already well into its service life. These are the factors we put in front of you:
If replacing does make sense, many Metro Vancouver homeowners look at a dual-fuel setup: a heat pump handles most of the heating and cooling through our long, mild shoulder seasons, and a gas furnace stays in place as backup for cold snaps. We lay out both paths, repair and replacement, in writing so you can decide without pressure. Replacing a gas furnace in BC is permitted work done by licensed gas fitters, and the permit and inspection should be listed on any replacement quote you receive.
- Age and repair history: an older furnace with several recent repairs is a different decision than a younger unit with its first fault.
- Where the fault actually is: a failed inducer or a restriction in the collector box or condensing heat exchanger is a larger job than tubing or a trap, and on an aging unit it is worth pricing replacement alongside the repair.
- Heat exchanger condition: if inspection shows corrosion, cracking or water damage in the combustion components, that changes the conversation, and we will show you what we see rather than just tell you.
- Parts availability: parts for older control generations can take longer to source, which matters in the middle of winter.
- Venting: if the existing vent run does not meet current requirements, a corrected vent is part of either path, and reworking a vent for an old furnace may make less sense than doing it once for new equipment.
Lennox furnace DS1 OFF DS2 slow flash service near me in Greater Vancouver
BC Wide Home Services Ltd is based in Burnaby and has served Metro Vancouver since 1999. We diagnose and repair pressure switch, venting and condensate faults on Lennox furnaces across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley.
Housing varies a great deal across those areas, and it changes what we tend to find. Older detached homes in parts of Vancouver, Burnaby and New Westminster often have high-efficiency furnaces that replaced older equipment, with sidewall vents fitted between windows, decks and a neighbour’s wall, so terminal clearances and vent routing come up often. Many newer subdivisions in Surrey, Langley and the Tri-Cities have furnaces in garages or crawl spaces where condensate lines can be long or run to a pump. On the North Shore, homes higher up the slopes can see more snow and frost at vent terminals than the rest of the region. In Richmond and Delta, open, low-lying ground can mean more wind across sidewall terminals. Townhouses and strata homes everywhere can have tight clearances and rules about changes to exterior walls, so we check strata requirements before proposing any vent change.
Our wet coastal climate matters too. Here it is usually long stretches of rain, not deep cold, that expose a poorly pitched vent or a slow condensate drain.
- Independent TSBC-licensed contractor, licence LGA0090068, with Class B gas licence CGA0028029.
- Gas work done by licensed gas fitters, with permits and inspections arranged wherever the work requires them.
- A written quote before any work beyond the diagnosis.
- Independent, not an authorized dealer or warranty centre for any manufacturer; if your furnace may still be under manufacturer warranty, we tell you what to check before work starts.
- Furnace brands we service include Lennox, Carrier, Bryant, Trane, American Standard, Goodman, Amana, Rheem, Ruud, York, Daikin, KeepRite and Napoleon.
- Call (604) 473-9690. Same-day where we can.
More questions homeowners ask
What does DS1 OFF DS2 slow flash mean on a Lennox furnace?
It means the control has found the pressure switch open, or opening repeatedly during a heat call, which usually points to a blocked intake or exhaust vent, a blocked condensate line, or a switch that was already closed before the combustion air blower started. Confirm the meaning against the manual for your unit. The furnace will not heat reliably until the cause is found and fixed.
Can I reset a Lennox furnace showing DS1 OFF DS2 slow flash?
Once, and only if your owner’s manual allows it, after you have cleared the outside vent terminals and checked the condensate drain. Turn the furnace service switch off, wait the time the manual gives, and turn it back on. If the code comes back, stop resetting and call a licensed technician, because repeated resets can hide a safety fault.
Is it safe to run my Lennox furnace with a pressure switch fault?
The furnace will not run properly with this code, and that is deliberate: the pressure switch stops the burners when it cannot prove the vent is clear. Never bypass or jumper the switch to force the furnace to run. If you smell gas or a CO alarm sounds, leave the home and call FortisBC or 911 from outside.
Why does my Lennox pressure switch code come back when it rains or gets windy?
Weather-linked codes usually point to the vent or the drain rather than the switch. Wind across a sidewall terminal can change the pressure the switch sees, and rain can collect in a vent pipe that is not sloped correctly or slow down a condensate drain. A technician measures the actual pressure and inspects the vent run to find which one it is.
Can you fix a Lennox DS1 OFF DS2 slow flash code the same day?
Same-day where we can. Many of these faults are cleared on the first visit when the cause is a blocked terminal, drain, tubing or switch and the part is on the truck. Jobs that need an inducer motor, a special-order part or a vent reroute can take longer, and during a cold snap we triage no-heat calls, so we tell you honestly what to expect.
Does fixing furnace venting need a permit in BC?
Altering or replacing gas appliance venting, or replacing the furnace, is gas work that generally needs a permit and must be done by a licensed gas fitter. Simple repairs such as clearing a condensate drain or replacing pressure tubing usually do not involve a permit. Your contractor should state in writing whether a permit applies to the work on your quote.
- Lennox Boiler Code 150 — Fan or fan wiring fault | BC Wide
- Lennox Boiler Code 18 — Gas valve fault | BC Wide
- Lennox Boiler Code 19 — Automatic water refill enabled | BC Wide
- Lennox Boiler Code 20 — Max water refill reached / Central Heating Flow or Flue NTC fault | BC Wide
- Lennox Boiler Code 321 — Domestic hot water NTC sensor fault | BC Wide
- Lennox Boiler Code 384 — False flame detected | BC Wide
- Lennox Boiler Code 385 — Under voltage (low supply voltage) | BC Wide
- Lennox Boiler Code 40 — Central Heating Return NTC fault | BC Wide
- Lennox Boiler Code 50 — Hot Water NTC fault (tank version) | BC Wide
- Lennox Boiler Code 53 — Flue obstruction – combustion off | BC Wide
Frequently asked questions
How often should a furnace be serviced?
How long does a furnace last in Vancouver's climate?
Why is my furnace blowing cold air?
How much does a new furnace cost in Vancouver?
What is the most reliable furnace brand?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.