On a Lennox furnace, DS1 and DS2 both steady on, or one on and one off, is documented as a control board failure or a control that has been wired incorrectly. Confirm against the manual for your unit. In practice the furnace will usually not run a normal heating cycle, so expect no heat. Check that the breaker and furnace switch are on and the thermostat is calling, then stop. Testing or replacing the SureLight board and correcting wiring is licensed work. Call (604) 473-9690.
If your Lennox furnace is showing DS1 steady ON & DS2 steady ON (also ON/OFF or OFF/ON) (Control board failure / miswired), here’s exactly what it means and what to do. This guide is part of our full Lennox furnace error code list.
Severity: Critical — likely no heat / lockout.
What DS1 steady ON & DS2 steady ON (also ON/OFF or OFF/ON) means on a Lennox furnace
Both LEDs steady on, or one on and one off, indicates a circuit board failure or that the control has been wired incorrectly.
Common causes
- Failed SureLight control board
- Incorrect control wiring
What you can safely check first
- Confirm the furnace has power and the breaker is on
- No safe homeowner repair — this requires a technician to test or replace the control
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox furnace repair across Greater Vancouver
If a Lennox furnace showing DS1 steady ON & DS2 steady ON (also ON/OFF or OFF/ON) won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox furnace codes
- Lennox furnace DS1 & DS2 simultaneous slow flash — Normal power / standby
- Lennox furnace DS1 & DS2 simultaneous fast flash — Normal heat call
- Lennox furnace DS1 slow flash, DS2 steady ON — Primary/secondary limit open
- Lennox furnace DS1 OFF, DS2 slow flash — Pressure switch open / vent blocked
- Lennox furnace DS1 & DS2 alternating slow flash — Watchguard — failed to ignite
- Lennox furnace DS1 slow flash, DS2 OFF — Flame sensed without gas valve energized
Frequently asked questions
Is DS1 steady ON & DS2 steady ON (also ON/OFF or OFF/ON) on a Lennox furnace serious?
It’s a lockout/safety code — the furnace has shut down and needs prompt diagnosis. BC Wide repairs Lennox furnaces 7 days a week across Greater Vancouver.
How do I reset a Lennox furnace after DS1 steady ON & DS2 steady ON (also ON/OFF or OFF/ON)?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox furnace error code DS1 steady on DS2 steady on also on off: what it means for you
In plain terms, the two small diagnostic lights on the furnace control are not showing the normal status pattern printed on the label inside the furnace door. Instead, both lights sit on solidly, or one stays lit while the other stays dark and nothing changes. Lennox documents this as a circuit board failure or a control that has been wired incorrectly. Confirm against the manual for your unit, because control board generations differ and the label on your furnace is the final word.
What it means for your house is simpler: the control board is the part that runs the whole heating sequence. It decides when the draft inducer starts, when the igniter heats, when the gas valve opens, when the flame is proven and when the blower moves warm air through the ducts. If the board has failed or is wired wrong, that sequence cannot run reliably, so the usual result is no heat. Depending on how the board has failed, the blower may sit idle, or in some cases it may run without the burners ever lighting.
Your domestic hot water normally comes from a separate gas water heater, so showers and taps are usually unaffected by this fault. If you heat with a heat pump paired to this furnace, the heat pump side may still run in mild weather, but the gas backup you rely on during a cold snap will not be available until the control is repaired.
On safety: a board that cannot run its sequence will usually refuse to light the burners, which is the safe way for it to fail. The concern is a miswired control, because wiring mistakes can confuse the safety circuits the board relies on. That is why this pattern is treated as a stop-and-call fault rather than something to reset repeatedly.
In owner words, these are the symptoms people describe to us when they phone about this code:
- The house is getting cold, the thermostat says it is calling for heat, and the furnace is silent.
- Two small lights, visible through the viewing window on the blower door on many models, are both lit and not flashing.
- One light is on and the other is off, and neither one changes no matter what the thermostat does.
- The furnace fan runs constantly, or never starts at all, regardless of the thermostat setting.
- The problem started right after a power outage, a windstorm or a flicker in the lights.
- A new thermostat was installed, or other work was done near the furnace, and it has not run properly since.
Why a Lennox furnace shows DS1 and DS2 steady on: likely causes, most common first
The code itself points at two things: the SureLight control board or its wiring. What we actually find on site usually falls into one of the causes below, listed roughly in the order we see them. Each row shows what a homeowner may safely look at and the point where it becomes a call for a licensed technician.
Owner-safe checks are deliberately limited. You may confirm power, confirm the gas supply valve is open, confirm the thermostat is calling, look at the outside vent terminals and look at any condensate drain you can see without removing panels. A single reset is reasonable only if your owner manual allows it. Do not open the burner compartment or the control panel, do not jumper or bypass anything, and do not keep cycling the power hoping the lights will change. If one reset does not clear the pattern, the board or its wiring needs to be tested with meters.
Gas and carbon monoxide safety: if you smell gas, or a carbon monoxide alarm sounds, do not try any check at all. Leave the house with everyone in it, do not operate switches, and call FortisBC or 911 from outside. Every home with a gas furnace should have working carbon monoxide alarms near sleeping areas, and they are worth testing whenever the furnace has acted up.
| Likely cause | What you may notice | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Failed SureLight control board from age, heat or an internal component fault | Lights stuck on or stuck in a fixed on and off state, no heat, sometimes a fan that will not stop | Confirm breaker and furnace switch are on; one reset only if the manual allows it | Immediately after one reset fails; the board must be tested and replaced by a licensed technician |
| 2. Incorrect control wiring after a thermostat swap or other work | Fault began right after new thermostat, smart thermostat or other work near the furnace | Note what was changed and when; do not rewire terminals at the furnace | Right away; wiring at the furnace control is checked against the wiring diagram by a technician |
| 3. Power surge or outage damage | Fault appeared after a storm, outage or flicker | Check breaker, furnace switch and any surge protector on the circuit | If power is confirmed and the lights stay in this pattern |
| 4. Water or condensate reaching the board | Water stains, drips or a wet floor near the furnace; a high-efficiency unit with a slow drain | Look at the visible condensate drain line and floor for water; switch the furnace off if water is near the controls | Any time water has reached electrical parts or the drain is blocked inside the cabinet |
| 5. Loose or corroded low-voltage connections | Fault comes and goes, especially in a damp basement or crawlspace | None beyond a visual look from outside the cabinet | When the fault returns; connectors and harnesses are tested inside the furnace |
| 6. Incoming power or transformer problem | Lights behave oddly, other symptoms on the same circuit | Confirm the breaker has not tripped and the switch is fully on | If the breaker trips again or the pattern persists with power confirmed |
How our Lennox furnace DS1 DS2 repair visit works, step by step
A control board fault is diagnosed with meters, not by guessing from the lights. This is how a visit from one of our licensed technicians runs, so you know what to expect and what you should see before any money is committed to a repair.
The parts most often involved with this pattern, in general terms, are the furnace control board itself, the low-voltage transformer that feeds it, the wiring harness and connectors between the board and the furnace components, and the thermostat cable or the thermostat. A control board is one of the more expensive parts on a gas furnace, which is exactly why we confirm the fault on the bench of the actual furnace before we quote one.
- Step 1, the call: we ask what the two lights are doing, when it started, whether there was an outage or recent work, and the furnace model if you can read the label. We offer same-day where we can, but we never promise a guaranteed arrival window.
- Step 2, safety first: on arrival the technician checks for gas odour and carbon monoxide around the appliance and takes a first look at the venting before touching anything.
- Step 3, confirm the code: the light pattern is recorded and compared against the documentation for your specific model, so the diagnosis starts from the right reference.
- Step 4, test the supply: line voltage, polarity and grounding at the furnace are checked with a meter, then the low-voltage output from the transformer.
- Step 5, trace the wiring: thermostat wiring and furnace wiring are compared to the wiring diagram on the furnace door, which is how a miswired control is found and proven.
- Step 6, evaluate the board: inputs and outputs are tested, and the board is inspected for scorch marks, corrosion, moisture damage or loose connectors.
- Step 7, written quote: before any work beyond diagnosis, you get a written quote naming the part, the labour, and whether the part is on hand or must be ordered.
- Step 8, the repair: the correct replacement control for your model is installed and configured to match the original settings, or the wiring fault is corrected.
- Step 9, test the safeties: the furnace is run through full heating cycles while the limit, pressure switch, flame sensing and rollout protection are confirmed working, and the flue is checked for carbon monoxide.
- Step 10, paperwork: you receive a written record of what was found, what was replaced and what was tested, and we show you the old part.
Repair or replace: is a new control board worth it on an older Lennox furnace?
On a furnace that is otherwise healthy, replacing a failed control board is a normal, sensible repair. The board is an electronic part; it can fail on a furnace whose heat exchanger, burners and blower are all in good shape. In that case, a correct board, properly configured and tested, returns the furnace to full service.
The decision changes when the furnace is older and the board is only the latest problem. We look at the whole appliance during diagnosis, not just the board, and we put both options in writing when replacement is worth considering. These are the factors that decide it on site:
- Heat exchanger condition: any sign of cracking, heavy corrosion or flame problems moves the conversation toward replacement, and we will explain what we saw.
- Part availability: on some older models the original board is no longer easy to source, and a compatible replacement control has to be matched carefully.
- Other worn parts: an inducer motor, blower motor or igniter that is near the end of its life adds up quickly when combined with a board.
- Efficiency and venting: an older mid-efficiency furnace cannot be upgraded in place; a high-efficiency replacement means new plastic venting and a condensate drain, which we assess as part of the quote.
- Repair history: several no-heat calls in recent winters are a stronger signal than any single repair.
- Your plans: if you have been considering a heat pump, a dual-fuel system pairs a heat pump with a gas furnace kept as backup for cold snaps. Pairing it with a new furnace and a compatible thermostat is often the cleanest time to make that change.
- Paperwork: whichever way you go, you should see the scope, the equipment, the labour and the permit handling in writing before work starts.
Lennox furnace error code service near me: Greater Vancouver coverage
BC Wide is based in Burnaby and has served Metro Vancouver homes since 1999. We diagnose and repair Lennox control board faults across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley.
The housing stock varies a lot across that area, and it changes what we find. Older detached homes in Vancouver, Burnaby and New Westminster often have furnaces in tight basements, sometimes with wiring that has been added to by several owners over the years, which is exactly where a miswired control shows up. Townhouses and strata units in Richmond, Coquitlam and the Tri-Cities often have furnaces in closets or mechanical rooms where access and venting routes are limited. Newer neighbourhoods in Surrey and Langley tend to have high-efficiency furnaces with plastic venting and condensate drains, where a blocked drain can let water reach the controls. On the North Shore and in parts of Delta, damp crawlspaces and garages can be hard on low-voltage connections over time. These are general patterns, not rules, and your furnace may be different.
Our mild, wet coastal climate also matters. The heating season is long but usually moderate, so furnaces run many hours a year. Windstorms and short outages can stress control boards, and humid basements encourage corrosion on connectors. Cold snaps are when a failed board is noticed, and when calls peak, so getting a suspect furnace looked at before the cold arrives is the easier path.
Besides Lennox, our technicians service gas furnaces from Carrier, Bryant, Trane, American Standard, Rheem, Ruud, Goodman, Amana, York, Daikin and KeepRite. These are brands we service; we are an independent contractor, not an authorised dealer or warranty centre for any manufacturer.
Who should fix a Lennox DS1 DS2 fault, and what a correct job looks like in writing
In BC, work on gas appliances and their controls is restricted to licensed trades. BC Wide Home Services Ltd is an independent, Technical Safety BC licensed gas contractor (licence LGA0090068) and our technicians hold Class B gas licensing (CGA0028029). Diagnostics and repairs are done by our own staff, never subcontractors.
A correct control board repair is more than swapping a part. The replacement must be the right control for your furnace, configured to match how the furnace was set up, wired to the diagram on the door, and then proven through complete heating cycles with every safety confirmed. A furnace that simply lights once after a board swap has not been properly tested.
Permits follow the scope of the work. A full furnace replacement requires a gas permit and inspection, which we arrange. For component repairs, we tell you in writing whether a permit applies to your job.
Before you approve anything, you should have the following in writing:
- The diagnosis, including what was measured and why the board or wiring was identified as the cause.
- The exact part being installed and whether it is an original-equipment control or a compatible replacement.
- The labour and any additional parts, quoted before work beyond diagnosis begins.
- The warranty terms that apply to the part and to our workmanship.
- Confirmation after the repair that safeties were tested and the flue was checked for carbon monoxide.
More questions homeowners ask
What does DS1 steady on and DS2 steady on mean on a Lennox furnace?
It is documented as a control board failure or a control that has been wired incorrectly, and the same applies when one light is on and the other is off. Confirm against the manual for your unit. In practice it usually means no heat until a licensed technician tests the board and its wiring.
Can I reset a Lennox furnace when both DS1 and DS2 lights are on?
Only once, and only if your owner manual allows it, by switching the furnace off at its service switch and back on. If the lights return to the same pattern, stop. Repeated resets will not fix a failed board or a wiring fault and can hide a safety issue.
Is it safe to run my Lennox furnace with DS1 and DS2 steady on?
Do not try to force it to run. A failed board usually refuses to light the burners, but a miswired control can interfere with the safety circuits, so leave the furnace off and call a licensed technician. If you smell gas or a carbon monoxide alarm sounds, leave the house and call FortisBC or 911 from outside.
Can I replace a Lennox SureLight control board myself?
No. Replacing and configuring a gas furnace control is licensed work in BC, and the furnace must be tested afterwards with every safety confirmed. A homeowner may check power, the thermostat and the gas supply valve, but nothing inside the control or burner compartment.
Did my new thermostat cause the DS1 and DS2 lights to stay on?
It can. Incorrect control wiring is one of the documented causes of this pattern, and it often shows up right after a thermostat change. Tell the technician what was installed and when, and do not rewire terminals at the furnace yourself.
How fast can you fix a Lennox furnace control board fault in Greater Vancouver?
We offer same-day service where we can, but we never promise a guaranteed arrival window. Diagnosis is usually completed on the first visit; whether the repair is finished the same day depends on whether the correct control for your model is on hand or has to be ordered. Call (604) 473-9690 and we will tell you honestly what to expect.
- Lennox Boiler Code 150 — Fan or fan wiring fault | BC Wide
- Lennox Boiler Code 18 — Gas valve fault | BC Wide
- Lennox Boiler Code 19 — Automatic water refill enabled | BC Wide
- Lennox Boiler Code 20 — Max water refill reached / Central Heating Flow or Flue NTC fault | BC Wide
- Lennox Boiler Code 321 — Domestic hot water NTC sensor fault | BC Wide
- Lennox Boiler Code 384 — False flame detected | BC Wide
- Lennox Boiler Code 385 — Under voltage (low supply voltage) | BC Wide
- Lennox Boiler Code 40 — Central Heating Return NTC fault | BC Wide
- Lennox Boiler Code 50 — Hot Water NTC fault (tank version) | BC Wide
- Lennox Boiler Code 53 — Flue obstruction – combustion off | BC Wide
Frequently asked questions
How often should a furnace be serviced?
How long does a furnace last in Vancouver's climate?
Why is my furnace blowing cold air?
How much does a new furnace cost in Vancouver?
What is the most reliable furnace brand?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.