Lennox furnace error code E200 means the flame rollout limit switch is open (confirm against the manual for your unit). The furnace saw flame or hot combustion gas where it should not be, and it is blocking heat until the cause is found and the switch is reset. Set the thermostat to OFF, check that the outdoor intake and exhaust pipes are clear of snow, leaves or nests, and do not reset the switch yourself. For a licensed gas technician, call (604) 473-9690.
If your Lennox furnace is showing E200 (Furnace rollout limit switch open), here’s exactly what it means and what to do. This guide is part of our full Lennox furnace error code list.
Severity: Critical — likely no heat / lockout.
What E200 means on a Lennox furnace
iComfort: the furnace flame rollout limit switch is open. The control will not allow heating until the cause of the rollout trip is corrected and the switch is reset.
Common causes
- Flame rollout from a blocked vent, restricted heat exchanger, or unstable flame
- Blocked or obstructed intake/exhaust vent pipe
What you can safely check first
- Set the system to OFF
- Check for and clear any blockage at the outdoor intake and exhaust vent terminations
- Do not reset the rollout switch yourself — call a technician to find the cause
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lennox furnace repair across Greater Vancouver
If a Lennox furnace showing E200 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lennox furnace codes
- Lennox furnace DS1 & DS2 simultaneous slow flash — Normal power / standby
- Lennox furnace DS1 & DS2 simultaneous fast flash — Normal heat call
- Lennox furnace DS1 slow flash, DS2 steady ON — Primary/secondary limit open
- Lennox furnace DS1 OFF, DS2 slow flash — Pressure switch open / vent blocked
- Lennox furnace DS1 & DS2 alternating slow flash — Watchguard — failed to ignite
- Lennox furnace DS1 slow flash, DS2 OFF — Flame sensed without gas valve energized
Frequently asked questions
Is E200 on a Lennox furnace serious?
It’s a lockout/safety code — the furnace has shut down and needs prompt diagnosis. BC Wide repairs Lennox furnaces 7 days a week across Greater Vancouver.
How do I reset a Lennox furnace after E200?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lennox furnace error code E200: what it means for your heat, hot water and safety
Put simply, E200 means your furnace has shut itself down to protect your home. On a Lennox iComfort system the code points to an open flame rollout limit switch (confirm against the manual for your unit). The switch sits near the burners. It opens when flame or very hot combustion gas rolls out of the space it is meant to stay in. Once the switch opens, the control stops calling for gas, and the house cools until someone finds and corrects the cause.
Heat: expect no heat at all, or a furnace that lights for a moment and shuts off before the house warms up. Hot water: in most homes the water heater is a separate appliance, so hot water keeps working. The one exception is a water heater that shares a chimney or vent connector with the furnace. If that shared flue is blocked, it can affect both appliances. If your water heater sits next to the furnace on a common vent, tell the technician.
Safety: rollout means combustion is not going where it should. That is why this code is treated as critical and not as a nuisance fault. The switch did its job. The real work is finding out why flame or hot gas escaped, because the same conditions that cause rollout can also push carbon monoxide into the living space.
Here is what homeowners usually tell us when they call about this code:
- The thermostat is calling for heat, but the vents blow cool air or nothing at all.
- The furnace starts and the burners light, then everything stops after a short time.
- The thermostat or iComfort screen shows E200 or a rollout message, and heat is locked out.
- Before the code appeared there was a scorched mark near the burner opening or a hot, singed smell.
- Heavy snow, a windstorm or yard work happened near the outside vent pipes just before the fault.
- The furnace ran fine for years, then began faulting after a renovation, new insulation, or a new appliance in the same room.
| What you notice | What it often points to | Who should handle it |
|---|---|---|
| E200 on screen, no heat, outside vent pipes buried in snow or leaves | Restricted intake or exhaust disturbing the draft | Owner may clear the outside terminal; a technician confirms the cause and resets the switch |
| Burners light, then shut down quickly | Flame being pushed out of the burner area | Licensed gas technician |
| Scorch or soot marks near the burner opening | Rollout that has happened more than once, possibly a restricted heat exchanger | Licensed gas technician; do not keep running the furnace |
| Code appeared after a renovation or a new appliance was added | Combustion air starved or venting disturbed | Licensed gas technician to check venting and combustion air |
| CO alarm sounding, or people feeling headachy, dizzy or sick | Combustion gases getting into the home | Leave the house and call 911 or FortisBC from outside |
Lennox furnace error code E200: likely causes, most common first, and the owner-safe check for each
In Metro Vancouver homes, these are the causes we find most often behind a rollout trip on a gas furnace, roughly in order. For each one you will see what you can safely look at and the point where it becomes a job for a licensed gas fitter. Under BC rules, anything inside the burner compartment, the gas valve, the venting connections and the control wiring is work for a licensed technician.
- 1. Blocked outdoor intake or exhaust terminal. High-efficiency furnaces that vent through a side wall can be choked by a snow drift, wet leaves, a wasp or bird nest, or a shrub grown over the pipes. Owner check: from safe footing, look at the two pipes outside and gently clear snow or debris from around the openings, without pushing anything into the pipe. Licensed call: the pipes look clear and the code stays, or something is lodged inside a pipe.
- 2. Venting inside the house is restricted or has failed. A sagging, disconnected or cracked vent pipe stops combustion gases from leaving cleanly, and so does a deteriorated chimney liner on an older mid-efficiency setup. Owner check: look but do not touch, and note any pipe joint that has visibly separated or is dripping. Licensed call: always, because vent repairs are gas work.
- 3. Restricted heat exchanger. Soot or debris inside the heat exchanger, or wear on an older furnace, leaves the flame no clean path, so it curls out toward the switch. Owner check: none beyond noting the furnace’s age and any scorch marks. Licensed call: always. This cause matters most when deciding whether to repair or replace.
- 4. Unstable or lifting flame. Dirty burners, wrong gas pressure, a misaligned burner, or a draft inducer that is not moving enough air can all make the flame unstable. Owner check: confirm the handle on the furnace’s gas supply valve is open (in line with the pipe) and change nothing else. Licensed call: gas pressure and burner work are for licensed technicians only.
- 5. Starved combustion air. A furnace shut into a small room, a new solid door, fresh weatherstripping, or a strong kitchen or bath exhaust fan can starve or pull against older furnaces that draw air from the room. Owner check: make sure the furnace room door, grilles and louvres are not newly blocked by storage. Licensed call: the room was renovated, or the code seems tied to exhaust fans running.
- 6. Condensate drain problem disturbing the venting side. On a condensing furnace, a backed-up trap or hose can upset the draft and pressure switch circuit. Owner check: look at the visible clear tubing and trap for standing water or a hose that has come off. Licensed call: clearing or rebuilding the trap and testing the pressure switch circuit.
- 7. A faulty switch. Now and then the switch itself has failed, but we treat that as the last explanation, never the first. Swapping a rollout switch without proving why it opened is how unsafe furnaces get put back into service.
What not to do with a Lennox E200 code, and when it becomes a licensed call
Some basic checks apply in every case. Make sure the furnace power switch (usually a light-style switch on or near the furnace) is on. Set the thermostat to heat and above room temperature. Check that the gas valve handle is open. If all three are fine and you have cleared the outdoor terminals, you have done everything a homeowner should do.
Do not reset the rollout switch, open the burner door, jumper or bypass any safety, or keep cycling power in the hope that the code clears. Many rollout switches are manual-reset devices inside the burner compartment, so a person has to investigate before heat can come back. If the owner manual for your unit allows a single power cycle after you clear an outdoor blockage, try it once only. If E200 returns, stop and call.
It is a licensed call as soon as any of these is true: the code comes back, you see scorch marks or soot, the vent pipes look damaged or disconnected, you are unsure whether the gas valve is set correctly, or anyone in the home has symptoms like headache, nausea or dizziness that ease when they go outside.
Gas and carbon monoxide safety: if you smell gas (a rotten-egg odour) or your CO alarm goes off, do not operate light switches, the thermostat or the furnace. Get everyone out first, then call FortisBC or 911 from outside. Every home with a gas furnace should have working CO alarms near the bedrooms. Rollout is exactly the kind of fault they are there for.
How our Lennox E200 repair visit works, step by step
A rollout fault needs a methodical visit, not a quick reset-and-go. Here is how our technicians handle it, so you know what a correct job looks like and what you should get in writing.
- 1. Phone triage. When you call (604) 473-9690 we ask what the screen shows, whether anyone has reset anything, whether a CO alarm has sounded, and what the outside vent pipes look like. We book same-day where we can. During a cold snap the schedule fills quickly, so we will tell you honestly when the earliest realistic visit is and never promise an arrival window we cannot keep.
- 2. Safety check on arrival. Before opening anything, the technician tests the air around the furnace and in the living space for carbon monoxide with a calibrated meter and makes sure the gas is safely controlled.
- 3. Visual inspection. The burner area, rollout switch, vent connections, condensate trap and outdoor terminals are checked for scorch marks, soot, separated pipes, moisture and blockages.
- 4. Measurements with the right instruments. Depending on the furnace, this covers gas pressure, draft or vent pressure, inducer and pressure switch operation, flame character and combustion readings in the flue.
- 5. Heat exchanger assessment. After a rollout, the heat exchanger is checked for restriction and damage, using whatever access the furnace design allows. If we think a camera inspection is needed, we tell you so and explain why.
- 6. Written findings and quote. You get the cause, the recommended fix and a written quote before any work beyond diagnosis starts. Nothing gets replaced on a guess.
- 7. Repair and full safety test. After the fix the switch is reset. The furnace then runs through several full heating cycles while the technician confirms the rollout switch, high limit, pressure switch and flame sensing all work. A final CO check finishes the test.
- 8. Written record. You keep a record of what we found, what we did, and anything to monitor or plan for.
| Part or area | What it does | Why it can be involved in E200 |
|---|---|---|
| Outdoor intake and exhaust terminals | Bring in combustion air and carry exhaust outside | A blockage disturbs the draft and can push flame out of the burner area |
| Vent pipe and connections | Carry combustion gases out of the house | Sags, separations or cracks restrict flow |
| Draft inducer | Pulls combustion gases through the furnace | Weak airflow can let the flame drift out |
| Burners | Mix gas and air and hold a stable flame | Dirt or misalignment makes the flame lift or roll |
| Heat exchanger | Transfers heat while keeping combustion gases separate | Restriction or damage leaves the flame nowhere to go |
| Condensate trap and tubing | Drain water from a condensing furnace | A backup can upset the venting side |
| Rollout limit switch | Opens when flame or heat escapes the burner area | Replaced only when testing proves the switch itself has failed |
Should I repair or replace a Lennox furnace that keeps showing E200?
Most E200 calls turn out to be repairs. A blocked terminal, a sagging vent or dirty burners can be corrected, and the furnace goes back to running safely. Replacement only comes into the conversation when the cause is the heat exchanger, or when the furnace is older and has a growing list of faults. Heat exchanger and control work are among the more expensive repairs on a gas furnace, so in that case we put both options on paper and leave the choice to you.
What tips the decision: the furnace’s age and general condition, the condition of the heat exchanger, whether parts are still available, how often it has needed service lately, and whether the house was comfortable even when the furnace worked. If you have the original registration paperwork, keep it handy. We are an independent contractor and not a warranty centre, so check any manufacturer coverage directly with the manufacturer rather than relying on what someone remembers.
If replacement makes sense, we usually start by talking through dual fuel. A heat pump handles most of the mild, wet Metro Vancouver heating season, and a new high-efficiency gas furnace is kept as backup for cold snaps. Gas stays available when you need it most. A furnace replacement needs a gas permit and inspection, and we take care of both.
| What we find | Usually points toward | Why |
|---|---|---|
| Outdoor terminal blocked, furnace otherwise healthy | Repair | Clearing and protecting the terminal fixes the root cause |
| Vent pipe separated or sagging | Repair | Venting can be corrected and re-supported to code |
| Burners dirty or misaligned, heat exchanger sound | Repair | Cleaning and adjustment restore a stable flame |
| Heat exchanger restricted but intact on a younger furnace | Repair, with a written assessment | Cleaning may be possible, and we explain its limits |
| Heat exchanger cracked or deteriorated | Replacement discussion | A damaged heat exchanger is a safety problem, not a tune-up item |
| Older furnace with repeat faults and comfort complaints | Replacement discussion, including dual fuel | Money spent on an aging unit may not fix the bigger picture |
Lennox furnace E200 repair near me: Greater Vancouver areas we cover and why it happens here
Our wet coastal climate shapes how rollout faults show up here. Through the long fall, wet leaves, needles and moss collect around side-wall vent terminals. The occasional heavy snowfall can bury low terminals overnight. Mild shoulder seasons also mean furnaces cycle on and off a lot, so a marginal draft problem gets plenty of chances to trip the switch. Housing stock matters too. Furnaces are often fitted into spaces never designed for them, and venting gets disturbed during renovations.
Vancouver: older character houses where modern furnaces were fitted into basements and old chimneys, plus newer infill with tight mechanical rooms. Burnaby, our home base: post-war bungalows, split-levels and townhouse complexes, with every vent arrangement you can imagine. Surrey: newer subdivisions and townhouses, where side-wall terminals often sit close to grade, fences and landscaping. Richmond: many homes with furnaces in garages or small utility rooms, where combustion air and storage clutter are worth checking.
Coquitlam and the Tri-Cities, including Port Coquitlam and Port Moody: hillside homes where wind and heavier snow at higher elevations can affect vent terminals. The North Shore, North Vancouver and West Vancouver: wetter, more wooded lots, with more snow up the slopes and plenty of forest debris around outdoor pipes. New Westminster: a lot of older housing and converted homes where chimneys and shared vents need a careful look. Delta and Langley: a mix of established neighbourhoods, newer developments and larger lots where long vent runs and exposed terminals are common.
Lennox is one of many brands we service. Our technicians also work on gas furnaces from Carrier, Bryant, Trane, American Standard, Rheem, Goodman, Amana, York and Daikin. We are an independent contractor that services these brands, not a factory-authorized dealer for any of them.
More questions homeowners ask
What does Lennox error code E200 mean?
On a Lennox iComfort system, E200 means the furnace flame rollout limit switch is open; confirm against the manual for your unit. The control will not allow heating until the cause of the rollout is corrected and the switch is reset. Treat it as a safety shutdown, not a nuisance code.
Can I reset a Lennox furnace E200 code myself?
No, not the rollout switch itself. It sits inside the burner compartment, and resetting it without finding the cause can put an unsafe furnace back into service. You can clear snow or debris from the outdoor vent terminals and check the power switch, thermostat and gas valve. After that, call a licensed gas technician.
Is it safe to run my Lennox furnace with an E200 code?
No. Rollout means flame or hot combustion gas is escaping where it should not, and the same conditions can push carbon monoxide into the house. Leave the thermostat off and have the furnace inspected. If a CO alarm sounds or you smell gas, get everyone out and call 911 or FortisBC from outside.
Why does my Lennox furnace keep showing E200 after it was reset?
Because the reset cleared the switch but not the cause. A repeat E200 usually means a venting restriction, an unstable flame, starved combustion air or a restricted heat exchanger. A technician has to measure draft, gas pressure and combustion to find it, and should hand you a written quote before any repair.
Can a Lennox E200 code be fixed the same day in Greater Vancouver?
Often it can, when the cause is a blocked terminal, a vent problem or burner cleaning, and we book same-day where we can. A heat exchanger problem or a part that has to be ordered takes longer. During a cold snap our schedule fills quickly, so we tell you honestly when the earliest realistic visit is.
Can snow or leaves on my outside vent pipes cause a Lennox E200 code?
Yes, a blocked intake or exhaust terminal is one of the most common reasons for a rollout trip on a side-wall vented furnace. Gently clear snow, leaves or nests from around the openings without pushing anything into the pipes. If the code is still there, a technician needs to reset the switch and confirm the furnace runs safely.
- Lennox Boiler Code 150 — Fan or fan wiring fault | BC Wide
- Lennox Boiler Code 18 — Gas valve fault | BC Wide
- Lennox Boiler Code 19 — Automatic water refill enabled | BC Wide
- Lennox Boiler Code 20 — Max water refill reached / Central Heating Flow or Flue NTC fault | BC Wide
- Lennox Boiler Code 321 — Domestic hot water NTC sensor fault | BC Wide
- Lennox Boiler Code 384 — False flame detected | BC Wide
- Lennox Boiler Code 385 — Under voltage (low supply voltage) | BC Wide
- Lennox Boiler Code 40 — Central Heating Return NTC fault | BC Wide
- Lennox Boiler Code 50 — Hot Water NTC fault (tank version) | BC Wide
- Lennox Boiler Code 53 — Flue obstruction – combustion off | BC Wide
Frequently asked questions
How often should a furnace be serviced?
How long does a furnace last in Vancouver's climate?
Why is my furnace blowing cold air?
How much does a new furnace cost in Vancouver?
What is the most reliable furnace brand?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.