Lennox Furnace Code E240 — Low flame current in run mode | BC Wide

Error Codes, Furnace, Hvac

Lennox Furnace Code E240 — Low flame current in run mode | BC Wide — BC Wide Heating & Air Conditioning, Greater Vancouver
Home › Lennox Furnace Code E240 — Low flame current in run mode | BC Wide

Lennox Furnace Code E240 — Low flame current in run mode | BC Wide

Quick answer

Lennox furnace error code E240 means low flame current in run mode: the burners lit, but while the furnace was running the flame-sensing signal dropped too low, so the control treated it as a weak or lost flame and shut the gas off. Confirm the meaning against the manual for your unit. The usual culprit is a dirty or corroded flame sensor, followed by a poor ground, a dirty burner face or exhaust recirculating at the vent. Check power, filter and outside vent, then book a licensed gas technician.

If your Lennox furnace is showing E240 (Low flame current in run mode), here’s exactly what it means and what to do. This guide is part of our full Lennox furnace error code list.

Severity: Needs attention.

What E240 means on a Lennox furnace

iComfort: low flame current, or a loss of flame, while the furnace is running. The flame-rectification signal from the sensor is weak.

Common causes

  • Dirty or corroded flame sensor
  • Poor unit ground
  • Dirty burner face
  • Vent termination recirculating exhaust
  • Loose gas valve wiring

What you can safely check first

  1. Replace a dirty air filter
  2. Confirm the outdoor vent termination is clear and not recirculating exhaust
  3. Flame sensor cleaning is a technician task — schedule service if it recurs

Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.

When to call a technician

This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lennox furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.

BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.

Lennox furnace repair across Greater Vancouver

If a Lennox furnace showing E240 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.

Related Lennox furnace codes

Frequently asked questions

Is E240 on a Lennox furnace serious?

It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lennox furnaces 7 days a week across Greater Vancouver.

How do I reset a Lennox furnace after E240?

You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.

Lennox Furnace Error Code E240: what it means for your heat and your home

In plain terms, E240 tells you the furnace started properly and then could not hold on to proof of flame. Every modern gas furnace watches its own burner flame through a small metal rod called a flame sensor that sits in the flame. The control board sends a small voltage to that rod, the flame conducts a very small current back to the grounded burner, and the board reads that current. When the reading sags below what the control is programmed to accept while the furnace is in run mode, the board closes the gas valve rather than risk unburned gas. That is the safety system doing its job, not the furnace giving up on its own. Confirm the exact wording against the manual for your unit, because display text varies between control generations.

What you notice at home depends on how often it happens. In the early stages the furnace may run for a few minutes, shut down, wait, and relight, so the house still warms, just more slowly and unevenly. As the signal gets weaker the retries fail more often, and the control can lock the furnace out until power is cycled or a built-in lockout period passes. On a cold, wet night in Metro Vancouver that means a house that slowly loses heat while the thermostat keeps calling.

Your domestic hot water is a separate question. A Lennox gas furnace heats air, not tap water, so a separate gas tank or tankless water heater keeps working while the furnace shows E240. If your home has a heat pump paired with this furnace in a dual-fuel setup, the heat pump may carry the load in mild weather, but on colder days when the system calls for gas heat you lose that backup until the fault is fixed.

What owners usually tell us when they call about E240:

  • The furnace starts, blows warm air for a short while, then goes quiet and the air from the registers turns cool.
  • The thermostat says it is heating, but the rooms never reach the set temperature.
  • You hear the inducer fan and igniter cycle several times before the burners finally stay lit.
  • The furnace works fine in the morning and quits later in the day, or the other way around.
  • The furnace display or iComfort thermostat shows E240 and the furnace will not restart until the power is turned off and back on.
  • The trouble started or got worse after a windy or snowy stretch, or after a fence, deck or garden work went in near the outside vent pipes.
  • Treat E240 as a needs-attention fault. On its own it is not usually a gas leak or a carbon monoxide emergency, but some of the conditions that weaken a flame signal, especially exhaust being drawn back into the combustion air, deserve a licensed look soon rather than at the end of the season.

Lennox furnace error code E240 causes, most common first, and what you can check yourself

These are the causes we find most often on Lennox furnaces showing E240 in Greater Vancouver homes, roughly in the order we find them. The list tells you where a technician starts looking. It does not tell you which part to buy, and swapping parts without measuring is how people end up paying twice.

The checks you can safely do yourself, in this order:

Do not open the burner compartment, pull or sand the flame sensor, jumper wires, or bypass any safety switch. Repeated resets keep sending gas to a burner that is struggling to prove flame, and they erase the very pattern a technician needs to see.

Gas and carbon monoxide safety: if you smell gas, a rotten-egg or sulphur smell, or a carbon monoxide alarm sounds, do not reset the furnace, do not operate light switches or appliances, and do not go looking for the source. Get everyone out of the house, then call FortisBC or 911 from outside. Every home with a gas furnace should have working CO alarms near the sleeping areas and on each level.

  • 1. Dirty or oxidized flame sensor. Over months of running, combustion by-products and dust bake a thin film onto the rod. That film insulates it and the signal drops. This is the single most common reason for E240.
  • 2. Poor ground. The flame signal needs a clean return path through the burner assembly and furnace chassis back to the control. A loose ground screw, a corroded terminal or a weak ground in the house wiring lowers the signal even with a clean sensor.
  • 3. Dirty or misaligned burner. Dust, debris, rust flakes or a burner that has shifted can push the flame away from the sensor, so the rod sits at the edge of the flame instead of in it.
  • 4. Exhaust recirculation at the vent termination. On high-efficiency furnaces with two pipes outside, exhaust can be drawn back into the intake when the pipes are blocked, buried in snow, too close together, or boxed in by a new fence, deck or shrub. Oxygen-starved combustion air produces a lazy, lifting flame and a weak signal.
  • 5. Loose or corroded wiring at the gas valve or sensor lead. Vibration and heating cycles loosen connectors over time, and a sensor wire that rubs on sheet metal can leak signal to ground.
  • 6. Less often: low or unstable gas pressure, a cracked ceramic insulator on the sensor, or a fault in the control board itself. These need instruments to confirm and are never something to guess at.
  • Power: the furnace service switch, usually a light-style switch on or near the furnace, is on, and the breaker for the furnace has not tripped.
  • Gas supply: the manual shut-off valve on the gas line to the furnace is open, with the handle running in line with the pipe. If you find it closed and do not know why, leave it closed and call us.
  • Thermostat: it is set to heat, set a few degrees above the room temperature, and has fresh batteries if it uses them.
  • Filter: a clogged filter makes the furnace run hotter and pull more dust through the cabinet. Replace it if it is grey or loaded.
  • Outside vent: the intake and exhaust terminals are clear of snow, leaves, nests and anything newly stacked against the wall. Clear loose debris by hand only from a safe spot.
  • Condensate drain: where you can see the clear drain tubing, it is not kinked, disconnected or sitting in a full pan.
  • Reset: only if your owner manual allows it, and only once. Switch the furnace off at the service switch, wait about a minute, and switch it back on. If E240 returns, stop resetting and book service.
Likely causeWhat you might noticeWhat you can safely checkWhen it becomes a licensed call
Dirty or oxidized flame sensorFurnace lights, runs briefly, shuts down and retriesNothing inside the cabinet; note how often it happens and whenAny recurring E240; cleaning or replacing the sensor is a technician task
Poor groundFaults that come and go with no clear patternConfirm the furnace switch and breaker are on and not trippingAlways; ground and polarity testing needs meters and access to wiring
Dirty or misaligned burnerRougher light-off, faults after the furnace sat idle all summerReplace a dirty air filterAlways; burner work means opening the burner compartment
Exhaust recirculation at the ventFaults in wind or snow, or after outdoor work near the pipesLook at the outside pipes and clear snow, leaves or debris by handIf pipes are damaged, crowded together, or close to a window, deck or fence
Loose gas valve or sensor wiringFaults after the furnace was bumped, moved or recently worked onNone; do not touch control or gas valve wiringAlways; wiring inside the cabinet is licensed work
Low gas pressure or control faultOther gas appliances acting up, or faults that survive a sensor serviceCheck whether your other gas appliances light normallyAlways; gas pressure and board diagnosis need instruments

How our Lennox furnace E240 repair visit works, step by step

An E240 call is mostly diagnosis. The code tells us where to look, not what to replace, so the visit is built around measuring rather than swapping parts until the code goes away.

You should leave with paperwork that names what was found and what was done. If the venting needs to be rerouted or the gas valve replaced, that is regulated gas work, and where a permit is required we take it out and the job is open to inspection.

  • Step 1, the phone call. We ask what the display or thermostat shows, how often the furnace shuts down, whether anything has changed outside near the vents, and whether anyone smells gas. If there is any gas or CO concern, we tell you to leave the house and call FortisBC or 911 first.
  • Step 2, booking. We offer same-day where we can. That depends on the day’s workload, traffic and where you are in the region, so we give you an honest window rather than a guaranteed arrival time.
  • Step 3, the fault history. Many Lennox controls store recent fault codes. Reading them shows whether E240 is new or has been building for weeks, and whether other faults are happening alongside it.
  • Step 4, measuring the flame signal. The technician reads the actual flame current with a meter set up for very small currents while the furnace runs, so we see the number the control sees instead of judging by how the flame looks.
  • Step 5, checking the return path. We verify the ground from the burner to the chassis and back to the electrical panel, plus line-voltage polarity, because a clean sensor cannot overcome a poor ground.
  • Step 6, combustion and venting. Gas pressure is checked with a manometer, the burner face and flame pattern are inspected, and the venting is checked outside for recirculation, slope and blockage. On high-efficiency units we check the condensate path as well.
  • Step 7, a written quote. Before any work beyond the diagnosis, you get a written quote that explains what we found, what we recommend and what it costs. Nothing goes ahead until you approve it.
  • Step 8, the repair. The parts most often involved are the flame sensor, its lead and connections, ground connections, the burner assembly, and the outside vent terminals. Less often it is the gas valve or the control board.
  • Step 9, testing the safeties. We run the furnace through several full heating cycles, re-read the flame signal, and test the safety controls, including the pressure and limit switches, before we leave.

Lennox furnace E240 on an older unit: repair or replace?

Most E240 calls end in a repair, not a new furnace. A flame sensor, a ground connection or a vent correction is a small part of the furnace, and fixing it does not commit you to anything larger. The replacement conversation only makes sense when the E240 visit turns up other problems.

Here is what we weigh with you, and put in writing:

A control board is one of the more expensive parts on a gas furnace, so if the diagnosis points to the board on an older unit, we say so plainly and put both the repair and the replacement option on the written quote. We do not push replacement to clear a sensor fault.

  • Heat exchanger condition. Any sign of cracking, through-rust or flame rollout changes the conversation immediately, because that is a safety issue, not a comfort one.
  • Repair history. If the furnace has needed several unrelated repairs over recent seasons, money spent now may only be buying time until the next failure.
  • Parts availability. Controls and gas valves for older Lennox furnaces can take longer to source, and a long wait for a part in January is a real cost even when the part itself is not expensive.
  • Fit with the house. Many older furnaces were sized by rule of thumb. A replacement is a chance to size properly from a load calculation and correct duct and airflow problems at the same time.
  • Your plans for cooling. If you want air conditioning, a replacement can pair a new gas furnace with a heat pump in a dual-fuel system, so the heat pump handles mild weather and the gas furnace carries the cold snaps.

Lennox furnace error code E240 service near me in Greater Vancouver

We service Lennox furnaces across Metro Vancouver from our base in Burnaby. Housing stock varies a lot across the region, and it shapes how and why E240 shows up. The notes below are general patterns we see, not rules for every home on every street.

Our climate matters too. Metro Vancouver winters are mild and wet rather than bitterly cold, so furnaces run long, low-demand cycles through months of damp weather. That combination encourages slow sensor fouling and corrosion at electrical connections, which is why E240 often appears in the middle of the heating season rather than on the first cold night. Strata townhomes add another layer: the vent terminal may sit on common property, so check your strata rules before anyone changes the venting, and we will work with your strata manager where it is needed.

  • Vancouver: a mix of older character houses, homes with basement suites, and newer townhomes. Furnaces in older houses are often in tight basement rooms where storage and dust crowd the cabinet.
  • Burnaby and New Westminster: many established houses where the furnace has been replaced at least once, sometimes reusing older venting or gas piping that we check carefully.
  • Surrey, Delta and Langley: many newer subdivisions with high-efficiency furnaces vented through a side wall, where fences, decks and landscaping added later can end up close to the vent terminals.
  • Richmond: much of the city sits on low, flat ground, and side-wall vents near grade can collect leaves and debris.
  • Coquitlam and the Tri-Cities, including Port Coquitlam and Port Moody: hillside houses and townhouse complexes where vent terminals can face the prevailing wind or sit in sheltered corners.
  • The North Shore: homes at higher elevations generally see more snow than the rest of the region, so a buried or iced intake is a more likely trigger after a winter storm.

Why homeowners call BC Wide for Lennox furnace error code E240

BC Wide Home Services Ltd is an independent, Technical Safety BC licensed gas contractor (licence LGA0090068), based in Burnaby and serving Metro Vancouver since 1999. Our gas work is done by our own licensed gas fitters under our Class B gas licence CGA0028029, not by subcontractors.

We are not a Lennox dealer, an authorised service centre or a warranty centre. We are an independent contractor that services Lennox furnaces alongside the other major brands. If your furnace is still under a manufacturer warranty, check its terms before you book and keep your installation paperwork handy.

What you can expect on every E240 call:

Furnace brands we service include Lennox, Carrier, Bryant, Trane, American Standard, Goodman, Amana, Daikin, York, Rheem, Ruud, Keeprite and Napoleon.

Call (604) 473-9690 and tell us the code on the display. That one detail helps us bring the right meters and the right expectations to your door.

  • Licensed gas fitters doing the diagnosis and the repair.
  • Measured readings rather than guesses: flame signal, gas pressure, ground and venting.
  • A written quote before any work beyond the diagnosis.
  • Permits and inspections where the work requires them.
  • Honest timing: same-day where we can, and a straight answer when we cannot.

More questions homeowners ask

What does Lennox furnace error code E240 mean?

It means low flame current in run mode: the furnace lit, but while it was running the flame sensor signal dropped below what the control accepts, so it treated the flame as weak or lost and shut off the gas. Confirm the meaning against the manual for your unit. The most common cause is a dirty or corroded flame sensor, followed by a poor ground, a dirty burner or exhaust recirculating at the vent.

Can I reset a Lennox furnace showing E240?

Once, and only if your owner manual allows it: switch the furnace off at its service switch, wait about a minute and switch it back on. If E240 comes back, stop resetting and book a licensed technician. Repeated resets hide the pattern a technician needs to see and keep cycling gas through a burner that cannot prove flame.

Is it safe to run my Lennox furnace with an E240 code?

The control shuts the gas off when it cannot prove flame, so the code itself is the safety system working. Do not keep forcing the furnace to run with resets, and book service soon, because exhaust recirculating into the intake is one possible cause. If you smell gas or a CO alarm sounds, leave the home and call FortisBC or 911 from outside.

Can I clean the flame sensor myself to fix Lennox E240?

We recommend you do not. Reaching the sensor means opening the burner compartment of a gas appliance, and in BC that work belongs with a licensed gas technician. A sensor cleaning also addresses only one of several causes, so if the real problem is a poor ground or vent recirculation, the code comes back.

How fast can I get Lennox furnace E240 repair near me in Greater Vancouver?

We offer same-day where we can, depending on the day’s bookings and where you are in Metro Vancouver, and we never promise a guaranteed arrival window. Many E240 repairs are finished on the first visit when the cause is the sensor, a connection or the vent. Call (604) 473-9690 to check availability.

Is BC Wide a Lennox authorised dealer or warranty centre?

No. BC Wide is an independent Technical Safety BC licensed gas contractor (licence LGA0090068) that services Lennox furnaces along with other major brands. If your furnace is still under manufacturer warranty, check its terms before booking.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a furnace be serviced?
Annual servicing is recommended for gas furnaces, ideally before the start of the heating season in September or October. Service includes burner cleaning, heat exchanger inspection, ignition check, blower motor cleaning, gas pressure adjustment and a full safety test for carbon-monoxide leaks.
How long does a furnace last in Vancouver's climate?
High-efficiency gas furnaces typically last 15–20 years with annual maintenance. Vancouver's mild climate means lower run-times than colder Canadian cities, which extends life — but salt-air corrosion near the coast and high humidity can shorten it.
Why is my furnace blowing cold air?
Common causes are a thermostat set to "on" instead of "auto", a tripped flame sensor, a clogged condensate drain shutting down a high-efficiency unit, low gas pressure, or a failed ignitor. Most are repairable in a single service visit.
How much does a new furnace cost in Vancouver?
A typical residential high-efficiency gas furnace in Metro Vancouver costs $4,500–$8,500 installed depending on size, brand and venting requirements. Variable-speed and modulating models are at the upper end.
What is the most reliable furnace brand?
In our experience servicing Vancouver homes since 1999, Carrier, Lennox, Bryant and York have produced the most reliable mid-to-high-efficiency furnaces with the best parts availability. Goodman and Rheem offer strong value at lower price points.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote