On a Lochinvar boiler, b06 means Low Voltage: the supply voltage to the control has dropped too low for safe operation, so the control temporarily blocks the burner until power recovers (confirm against the manual for your unit). The code itself does not damage the boiler, but heat and hot water stop while it shows. Check the breaker and service switch, reset once only if the manual allows, and call a licensed technician if it returns. BC Wide serves Greater Vancouver, same-day where we can: (604) 473-9690.
If your Lochinvar boiler is showing b06 (Low Voltage), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Needs attention.
What b06 means on a Lochinvar boiler
Temporary blocking: the supply voltage to the control has dropped too low for safe operation.
Common causes
- Low or unstable building supply voltage
- Loose power wiring connection
- Overloaded circuit
What you can safely check first
- Confirm other devices on the same circuit work and the breaker is on
- If building voltage seems low or unstable, have an electrician/technician check the supply
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing b06 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E00 — Invalid Lockout
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E06 — Auto Reset High Limit
Frequently asked questions
Is b06 on a Lochinvar boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after b06?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar boiler error code B06: what it means for your heat and hot water
In plain terms, b06 is the boiler protecting itself from bad power. The control needs a steady supply to run the igniter, the combustion blower, the gas valve and its own safety checks. When the incoming voltage sags below what the control treats as safe, it stops the burner rather than try to light on weak power. The page above describes this as a temporary block, which on many installs means the boiler clears itself and fires again once the supply recovers. Confirm the exact behaviour against the manual for your unit, because control versions differ.
What that means inside your house depends on what the boiler does. If it only heats, the radiators, fin-tube convectors or in-floor loops go cool and the rooms drift down slowly. Hydronic systems hold a lot of heat in the water and the floor, so you may not notice for an hour or two. If the boiler also makes domestic hot water through an indirect tank, the tank stops recovering and showers run out early. If the boiler is set up to make hot water on demand, the tap goes cold at the same moment the heat stops.
B06 is not a gas leak warning and it is not a carbon monoxide warning on its own. It is an electrical supply fault. The real concern is whatever is causing the low voltage: loose connections heat up over time, and repeated sags are hard on the electronics in the boiler and on everything else sharing that circuit.
Here is how owners usually describe it when they call us and b06 turns out to be behind it:
- The display shows b06 and the burner will not light, but the screen and the pump still seem to be alive.
- The code comes and goes, often right when a dryer, freezer, microwave or power tool starts up somewhere in the house.
- Heat stopped overnight or during a windstorm, and by morning the boiler was running again with no one touching it.
- Lights in the mechanical room or nearby rooms dim or flicker when the boiler tries to start.
- The boiler display goes blank for a moment or reboots on its own.
- The indirect hot water tank runs out sooner than usual for no obvious reason.
- A hot-plastic or burning smell near the boiler’s power switch or outlet. If you notice that, switch the boiler off at the breaker and call.
What causes Lochinvar boiler error code B06? Likely causes, most common first
The control only knows that the voltage it sees is too low. It cannot tell you why. In the boilers we work on across Metro Vancouver, the causes fall into a short list. The table puts them in the order we tend to find them, with what you can safely look at yourself and the point where it becomes work for a licensed trade.
Owner-safe checks, in this order:
- Confirm the boiler’s service switch is on and the breaker feeding it has not tripped. If it has, you may reset the breaker once. If it trips again, leave it off and call.
- Make sure the gas supply valve to the boiler is open, with the handle in line with the pipe. B06 is not a gas fault, but a valve left closed after other work will cause trouble once the power is sorted.
- Check that the thermostat or zone control is actually calling for heat and has fresh batteries if it uses them.
- If the owner manual allows a reset for this code, do it once. If the code comes back, stop and call.
- Outside, check that the intake and exhaust terminals are clear of leaves, snow, nests, garden furniture or anything stacked against them.
- Look at the condensate drain where you can see it: not kinked, not frozen at an outdoor discharge point, not backing up into the boiler.
- Do not remove the boiler’s front panel, open the electrical junction box, test terminals with a meter, jumper anything, or cycle power over and over to force the boiler to light. Each forced restart on weak power stresses the control, and it can hide a second fault.
| # | Likely cause | What you can safely check | When it becomes a licensed call |
|---|---|---|---|
| 1 | Shared or overloaded circuit: the boiler shares a circuit with other loads, and the voltage dips when something large starts | Notice whether the code appears when a dryer, freezer, microwave or shop tool kicks on. Check that the breaker has not tripped. | If there is a clear pattern or the breaker trips more than once. Moving the boiler to its own circuit is electrical work. |
| 2 | Loose or corroded connection at the service switch, receptacle or junction box feeding the boiler | Look without touching inside anything: is the switch fully on, is the plug fully seated if the boiler is cord-connected, are there scorch marks or warmth on the cover plate | Any heat, discolouration, buzzing or smell. Switch off at the breaker and call. Opening boxes is licensed work. |
| 3 | Building or utility supply dip: storms, grid work, an undersized service, or a failing connection in the panel | Do lights dim through the whole house? Did neighbours lose power or see flickering? Is there a utility notice for your area? | House-wide dimming or flickering points to the panel or the service. That is an electrician and possibly the utility. |
| 4 | Worn power switch, cord or plug supplying the boiler | Visual only: a cracked cord, a plug that feels loose, a switch that feels soft or does not click cleanly | Replacement of the switch, cord or receptacle is licensed work. |
| 5 | Backup power source, such as a generator or battery inverter, that sags under load | Does the code only appear when the house is running on backup power? | Sizing and transfer equipment are electrical work. We can tell you what the boiler needs to see. |
| 6 | Fault in the boiler’s own power path: control transformer, harness connector, or the control reading voltage incorrectly | Nothing. These parts are behind the boiler panels. | Always a licensed gas technician, and it is found by measuring, not by swapping parts. |
Is it safe to run a Lochinvar boiler with code B06, and when is it a licensed call?
A boiler showing b06 is usually sitting in a safe state, because the control has already stopped the burner. The risk comes from two places: what happens next, and whatever is causing the voltage problem. Repeatedly flipping the power to get a few minutes of heat out of the boiler puts the control through starts on weak power, and a connection that is loose enough to drop voltage is also loose enough to heat up. That is why the honest answer is that it is safe to wait, but not safe to keep forcing it.
It becomes a licensed call when any of these happen:
- The code returns after one reset, or shows up more than once in a day.
- The breaker feeding the boiler trips again after you reset it once.
- You see scorch marks, smell hot plastic, or hear buzzing at the switch, outlet or panel.
- Lights dim through the house whenever the boiler starts.
- The boiler display reboots, freezes, or shows other faults alongside b06.
- The house is losing heat and you have elderly occupants or infants at home, or pipes in an unheated crawlspace or garage are at risk in a cold snap.
- Gas and carbon monoxide safety: if you smell gas, a rotten-egg odour, leave the home right away without switching lights or appliances on or off, and call FortisBC or 911 from outside. If a carbon monoxide alarm sounds, get everyone out and call 911 from outside. Do not go back in to check the boiler. Every home with a gas boiler should have working CO alarms near sleeping areas and on each level, tested regularly. Nothing about b06 changes that rule.
How our Lochinvar boiler error code B06 repair visit works, step by step
A low-voltage fault sits right on the line between two licensed trades in BC. Work on the boiler’s gas train, burner, venting and appliance controls is licensed gas work under Technical Safety BC. Wiring in the building, meaning the panel, the circuit and the switch box feeding the boiler, falls under electrical rules and usually needs a licensed electrical contractor. A good diagnosis tells you which side of that line the fault sits on before anyone replaces anything. We book same-day where we can, depending on the day’s workload and where our technicians are in the region, and we never promise an arrival window we cannot hold.
This is what a B06 visit looks like from start to finish:
- 1. Booking call. We ask what the display shows, whether the code clears on its own, what else in the house is running when it appears, and whether you have heat and hot water right now. That tells us whether the problem is likely on the boiler side, the building side, or both.
- 2. Arrival and safety check. The technician confirms there is no gas odour, asks about your CO alarms, and reads the boiler’s fault history if the control stores one, so we can see how often b06 has been logged and what else appeared around it.
- 3. Measure, do not guess. Supply voltage is measured at the boiler with the burner idle and again while the blower and igniter are drawing power, because a connection that reads fine at rest can sag under load. We compare readings at the boiler against readings upstream to find where the drop happens.
- 4. Trace the power path. Switch, cord or hard-wired connection, junction, then inside the appliance: the control transformer, harness connectors and the control’s own reading. In general terms, the parts most often involved are a loose or heat-damaged connector, a worn switch or receptacle, a failing transformer and, less often, the control board itself. The board is one of the more expensive parts on a modern condensing boiler, which is exactly why it is the last thing we condemn, not the first.
- 5. Check the rest of the boiler while it is open. Venting, condensate trap and drain, the low-water cutoff, the pressure relief valve and system pressure. Metro Vancouver water is soft, so closed loops here tend to develop sludge and corrosion rather than limescale. We look at that too, because dirty system water makes the pump and burner work harder.
- 6. Written quote before any work. If the fix goes beyond the diagnosis, you get a written quote describing the work and the parts in plain language before anything is replaced. You decide before we start.
- 7. Repair, then test the safeties. After the repair we run the boiler through a full heating call, confirm the voltage holds under load, verify the safeties trip and reset as designed, check combustion and venting, and clear the fault history so any recurrence is easy to read later.
- 8. Findings in writing. You get what we measured, what we replaced, what we ruled out, and anything we found that is outside our scope, such as a panel or service problem that belongs with an electrician. When the cause is in the house wiring, we say so plainly and can help you coordinate the electrical side.
Repair or replace an older Lochinvar boiler that keeps showing B06?
A low-voltage code on its own is rarely a reason to replace a boiler. In most cases the fault is outside the boiler, or in a small part of its power path, and fixing it returns the unit to normal operation. Replacement becomes a fair question only when b06 is one symptom among several on an older unit.
These are the things we weigh with you on site before anyone talks about replacement:
- Repair history: whether the boiler has needed several repairs over the last few heating seasons, or this is the first fault in years.
- Heat exchanger condition: corrosion, weeping, or heavy sludge from years of untreated system water.
- Parts availability for older control platforms, which can make a board-level repair slow or impractical.
- Whether the boiler still suits the house after renovations, window upgrades, an added suite or finished basement.
- Whether you want to change how hot water is made, for example keeping an indirect tank versus going to on-demand hot water.
- Venting and condensate routing that may no longer meet current code for its location, which turns a straight swap into a larger job.
- If replacement is on the table, you get a written quote for both paths, repair and replacement, so you can compare them side by side. We do not push replacement because a code is on the screen.
Lochinvar boiler error code B06 service near you across Greater Vancouver
We service gas boilers and hydronic systems in Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities including Port Coquitlam and Port Moody, the North Shore, New Westminster, Delta and Langley. Low-voltage faults look a little different from one part of the region to another, mostly because of the age and layout of the housing and how the electrical service has been changed over the years.
In Vancouver, Burnaby and New Westminster, a lot of the housing is older and has been renovated more than once, so circuits were often added piece by piece over decades. It is common to find a boiler sharing a circuit with laundry or kitchen loads, which is a classic setup for b06. In Richmond and in the newer townhouse and strata stock around the region, mechanical closets tend to be compact, and in-suite boilers sometimes sit close to other equipment on shared circuits. Strata buildings with a central boiler plant are usually handled through the strata’s own mechanical arrangements; we focus on in-suite, townhouse and house boilers.
Across Surrey, Delta and Langley there is a mix of newer subdivisions and larger rural or acreage properties. Longer service runs, outbuildings on the same supply, and backup generators are more common on the rural side, and each can bring voltage sag into the picture. On the North Shore and in hillside parts of the Tri-Cities, treed lots and coastal windstorms mean more outages and flickers, and leaves and debris around intake and exhaust terminals are a regular find. These are tendencies we see in the field, not rules, and every house gets measured on its own terms.
Why owners call BC Wide for a Lochinvar b06: BC Wide Home Services Ltd has worked on Metro Vancouver heating systems since 1999. We are an independent contractor licensed by Technical Safety BC, gas contractor licence LGA0090068 and Class B gas licence CGA0028029, and the technicians on your boiler are licensed gas fitters. Brands we service for gas boilers and hydronic systems include Lochinvar, IBC, Viessmann, Navien, Weil-McLain, Buderus, Triangle Tube, Rinnai, Bosch and Burnham. We are not a factory-authorized dealer or warranty centre for any of them, so if your boiler is still under manufacturer warranty, keep your paperwork handy and we will document what we find. Where a job needs a permit, we take out the permit and arrange the inspection. You get a written quote before any work beyond diagnosis. Call (604) 473-9690.
More questions homeowners ask
What does B06 mean on a Lochinvar boiler?
B06 means Low Voltage: the supply voltage to the boiler’s control has dropped too low for safe operation, so the control temporarily blocks the burner. Confirm against the manual for your unit. It is an electrical supply fault, not a gas or carbon monoxide warning on its own, but the cause still needs to be found.
Can I reset a Lochinvar boiler with error code B06?
Only once, and only if the owner manual allows it for this code. Because b06 is described as a temporary block, the boiler often clears itself when the voltage recovers. If the code comes back, stop resetting and call a licensed technician, because repeated restarts on weak power stress the control and can hide a second fault.
Is it safe to run my Lochinvar boiler with B06 showing?
The boiler is usually in a safe state while b06 shows, because the burner is stopped. What is not safe is forcing it to run by cycling power, or ignoring signs like a warm switch, scorch marks, buzzing or a hot-plastic smell. If you notice any of those, switch it off at the breaker and call (604) 473-9690.
Why does my Lochinvar boiler show B06 only at night or during storms?
That pattern usually points to the supply rather than the boiler. Storms and grid work cause voltage dips, and at night other large loads in the house can start at the same time as the boiler. A technician can measure voltage at the boiler under load to confirm whether the drop is coming from the building, the circuit or the appliance itself.
Do I need an electrician or a gas technician for Lochinvar code B06?
Start with a licensed gas technician who can measure at the boiler and trace the power path inside the appliance. If the drop is in the building wiring, the panel or the circuit, that part goes to a licensed electrical contractor, and we tell you that in writing. Diagnosing first keeps you from paying for parts that were never the problem.
Can you fix a Lochinvar boiler showing B06 near me in Greater Vancouver today?
Same-day where we can, depending on the day’s workload and where you are in the region, but we do not promise a guaranteed arrival time. We cover Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Call (604) 473-9690 and tell us what the display shows.
- Lennox Boiler Code 150 — Fan or fan wiring fault | BC Wide
- Lennox Boiler Code 18 — Gas valve fault | BC Wide
- Lennox Boiler Code 19 — Automatic water refill enabled | BC Wide
- Lennox Boiler Code 20 — Max water refill reached / Central Heating Flow or Flue NTC fault | BC Wide
- Lennox Boiler Code 321 — Domestic hot water NTC sensor fault | BC Wide
- Lennox Boiler Code 384 — False flame detected | BC Wide
- Lennox Boiler Code 385 — Under voltage (low supply voltage) | BC Wide
- Lennox Boiler Code 40 — Central Heating Return NTC fault | BC Wide
- Lennox Boiler Code 50 — Hot Water NTC fault (tank version) | BC Wide
- Lennox Boiler Code 53 — Flue obstruction – combustion off | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.