Lochinvar boiler error code E00 (Invalid Lockout) means the boiler’s control has locked out and cannot match that lockout to a defined fault, which points to an internal control problem rather than a simple outside cause. Confirm against the manual for your unit. Expect no heat and, if the boiler feeds your hot water tank, no hot water. Cycle power once at the service switch. If E00 returns, stop and book a licensed gas technician. In Greater Vancouver call BC Wide at (604) 473-9690.
If your Lochinvar boiler is showing E00 (Invalid Lockout), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Critical — likely no heat / lockout.
What E00 means on a Lochinvar boiler
The control has registered a lockout that it cannot match to a defined fault condition, indicating an internal control fault.
Common causes
- Internal SMART SYSTEM control fault
- Corrupted control data
- Control board failure
What you can safely check first
- Note the code and cycle power once at the boiler’s service switch
- If it returns, call a licensed technician — the control board needs diagnosis
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing E00 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E06 — Auto Reset High Limit
- Lochinvar boiler E07 — Air Pressure Switch
Frequently asked questions
Is E00 on a Lochinvar boiler serious?
It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after E00?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar boiler error code E00: what it means for your heat, hot water and safety
In owner words, E00 means the boiler’s brain has stopped the boiler and cannot tell you why. On most fault codes the control points at something specific, such as a flame problem, a temperature limit or a blocked vent. With E00 (Invalid Lockout) the control registered a lockout it could not match to any defined fault condition, so the suspicion falls on the control itself. Confirm that meaning against the manual for your unit, because control software and code lists can differ between generations of equipment.
For your house, the practical result is simple: the burner will not fire while the lockout is active. Radiators, baseboard convectors or in-floor radiant loops will slowly cool. If your domestic hot water comes from an indirect tank heated by the boiler, or from a combi unit, hot water will run out as the stored water is used. A gas tank water heater on its own burner is separate and should keep working.
On safety, a lockout is the boiler doing its job. A control that is unsure of its own state is designed to fail toward off rather than keep firing, so E00 by itself is not a sign that the boiler is leaking gas. That changes immediately if you smell gas, hear a carbon monoxide alarm, see scorching around the boiler cabinet or notice water pooling under it. Those are not E00 problems; they are separate hazards that need a licensed response.
What owners usually tell us when they call about this code:
- The house was warm last night and cold this morning, and the display shows E00.
- The boiler display is lit but the burner never lights and the pumps are quiet.
- Hot water at the taps ran lukewarm, then cold, in a home with an indirect tank.
- The code cleared after switching power off and on, then came back within hours or days.
- E00 appeared after a power outage, a storm, or electrical work elsewhere in the house.
- The display is flickering, frozen, or showing E00 alongside odd or garbled readings.
Can I reset Lochinvar error code E00? The owner-safe checks, step by step
You can do a small set of checks before booking a visit, and doing them helps the technician because it rules out the easy causes. None of these steps involve opening a panel, touching wiring or working on the gas train. Gas work and the electrical work inside a boiler are restricted to licensed trades in BC, and a homeowner should never jumper, bypass or override a safety or control connection to get heat back.
Write the code down, and take a phone photo of the display before you touch anything. If there is a fault history menu that the owner manual tells you how to read, note what it shows. Then work through the table below in order and stop the moment the boiler runs normally or E00 returns.
- Do not keep resetting. Repeated resets on an unexplained lockout can mask a real safety fault and can make the control harder to diagnose.
- Do not remove the boiler front cover, unplug harnesses or reseat the control board.
- Do not clear snow or debris from a roof terminal yourself; call for help instead.
- If you smell gas or a carbon monoxide alarm sounds, leave the house now and call FortisBC or 911 from outside. Do not operate switches on the way out.
| Check | What to look for | Who does it |
|---|---|---|
| Power and service switch | The boiler service switch near the unit is on, and the breaker serving the boiler has not tripped. Do not reset a breaker more than once. | Homeowner |
| Gas supply valve | The manual gas shut-off on the line to the boiler is open (handle in line with the pipe). Do not loosen fittings or test for leaks yourself. | Homeowner can look; any gas work is licensed only |
| Thermostat calling | Thermostat set above room temperature, in heat mode, with fresh batteries if it uses them. | Homeowner |
| One power cycle | Switch the boiler off at the service switch, wait about a minute, switch it on. Only if the owner manual allows it, and only once. | Homeowner |
| Intake and exhaust terminals outside | Wall or roof terminals clear of leaves, snow, ice, nests or anything stacked against them. | Homeowner, from the ground only |
| Visible condensate drain | The plastic drain line from the boiler is not cracked, kinked or overflowing onto the floor or control area. | Homeowner can look; repairs are for the technician |
| E00 returns | Code comes back after the single reset, or within days. | Licensed gas technician |
Why does a Lochinvar boiler show E00? Likely causes, most common first
Because E00 means the control could not name the fault, diagnosis is about the control and everything that feeds it. In our experience on condensing boilers across the Lower Mainland, the causes below are ranked roughly from most to least common. Treat this as a general guide, not a diagnosis, and confirm the code meaning against the manual for your unit.
1. A one-off control glitch after a power event. Brownouts, outages and surges during winter windstorms are a common trigger for unexplained lockouts on electronic boiler controls. Owner check: did the power flicker or go out recently? A single power cycle may clear it. Licensed call: if it returns, or if the house has frequent power problems that may need surge protection or a dedicated circuit assessed by an electrician.
2. Corrupted or lost control data. The existing page notes corrupted control data as a cause. Settings and stored parameters can be disturbed so the control no longer trusts its own state. Owner check: none beyond the single reset. Licensed call: the technician checks and, where the manufacturer procedure allows, restores or reloads settings and verifies every safety afterward.
3. Moisture or heat stress reaching the electronics. A leaking condensate trap, a weeping relief valve or a small water leak above the cabinet can put moisture near the control. Owner check: look for drips, staining or a wet floor and report it. Licensed call: always, because water and gas appliance electronics do not mix and the source must be found and fixed first.
4. Loose or damaged connections to the control. Vibration, past service work and corrosion at terminals can cause intermittent signals the control cannot interpret. Owner check: none; do not open the cabinet. Licensed call: the technician inspects harnesses and terminals with the power isolated.
5. Internal control board failure. The existing page lists control board failure, and it is the cause owners most worry about. A control board is one of the more expensive parts on a modern boiler, which is exactly why it should be the conclusion of testing, not the first guess. Owner check: none. Licensed call: always, with the part confirmed against the boiler’s model and serial plate before ordering.
How our Lochinvar boiler E00 repair visit works, and what you should get in writing
We are an independent TSBC-licensed contractor, not an authorised dealer or warranty centre for any brand. Our gas work is done by our own licensed gas fitters under gas contractor licence LGA0090068 and Class B gas licence CGA0028029. Here is how a visit for an E00 lockout runs, step by step.
- Step 1, the call: we ask for the code, the photo of the display, what you already checked, the boiler’s approximate age and whether it also makes your hot water. We book same-day where we can; in a cold snap that is not always possible, and we will tell you honestly when the earliest slot is.
- Step 2, safety first on arrival: the technician checks for gas odour and combustion safety around the boiler and venting before anything else, and confirms the gas and power supplies.
- Step 3, read the history: we read the fault history and operating data the control has stored, and note conditions at the time of the lockout.
- Step 4, test, do not guess: with the right meters we check incoming voltage and polarity, grounding, low-voltage supply, connector condition and sensor readings, so a power or wiring problem is not mistaken for a failed board.
- Step 5, look at the whole system: condensate trap and drain, signs of moisture near the control, the intake and exhaust run, system pressure, and the condition of the hydronic water.
- Step 6, explain and quote: you get a plain-language explanation of what we found and a written quote before any work beyond diagnosis. The quote names the work and whether a part has to be ordered.
- Step 7, repair and verify: after the repair we run the boiler through full cycles, test the safeties and limits, check combustion, and confirm heat and hot water are back.
- Step 8, paperwork: where the work requires a gas permit, we pull it and the work is open to Technical Safety BC inspection. You keep a written record of what was done.
Lochinvar boiler with E00: repair or replace an older unit?
Most E00 calls end in a repair, not a replacement. A correctly diagnosed control problem on a boiler with a sound heat exchanger, healthy venting and clean system water is usually worth fixing. The repair-or-replace question only becomes real when the control fault arrives on an older boiler that is also showing other signs of wear.
On a condensing boiler, the heat exchanger is the part that decides the boiler’s remaining life. In Metro Vancouver our water is soft, so hydronic trouble here is rarely limescale; it is sludge and corrosion in the system water that slowly fouls the heat exchanger and stresses pumps and valves. If the technician finds dirty system water, a restricted heat exchanger, corrosion around connections or a history of repeat repairs, a new control may be good money after bad.
Parts availability matters as well. Controls for older generations of equipment can take time to source, and on some units a newer replacement control is supplied instead of the original. The technician should tell you plainly whether the part is available, what the lead time is, and whether that changes the recommendation.
What should push you toward repair, and what toward a replacement conversation:
- Lean repair: first significant fault, heat exchanger in good condition, clean system water, venting correct, part readily available.
- Lean replace: heat exchanger fouled or corroded, repeated lockouts across different parts over recent seasons, control parts hard to source, or the boiler is near the end of its expected service life.
- Either way: get it in writing. A replacement quote should cover sizing based on a heat loss calculation, venting, condensate disposal, system flushing and treatment, the gas permit, and how hot water will be handled.
- If you replace, the hydronic system should be cleaned and treated so the new boiler does not inherit the sludge that hurt the old one.
Lochinvar boiler error code E00 service near me in Greater Vancouver
We diagnose and repair Lochinvar boiler lockouts across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Our base is in Burnaby, and we have been working on Greater Vancouver heating systems since 1999.
The housing stock shapes the job. In older Vancouver and Burnaby homes, boilers often replaced original heating systems, so we commonly see mixed piping, older radiator circuits and system water that has never been treated. New Westminster and older North Shore homes can have tight mechanical rooms and long vent routes that complicate access. Townhouses and strata buildings in Richmond, Surrey, Coquitlam and the Tri-Cities may have boilers serving in-floor radiant heat, where strata rules on venting, access and permits come into play. In parts of Delta, Langley and Surrey with newer detached homes, combi units and indirect tanks are common, so an E00 often means both heat and hot water are down at once.
Our mild, wet coastal climate matters too. Constant rain and damp air are hard on outdoor vent terminals and condensate lines, and a wet mechanical room can put moisture where electronics do not want it. Short cold snaps with snow are when unexplained lockouts tend to be noticed, because the boiler is working its hardest and the house cools quickly.
Boiler brands we service include Lochinvar, IBC, Viessmann, Navien, Weil-McLain, Bosch and Rinnai. We work on these brands as an independent contractor; we are not a factory-authorised dealer or warranty centre for any of them, and warranty decisions rest with the manufacturer.
Why owners choose us for this call: we are a TSBC-licensed independent contractor, the work is done by our own licensed gas fitters, gas permits are pulled where required and the work is open to inspection, and you get a written quote before any work beyond diagnosis. Call (604) 473-9690.
More questions homeowners ask
What does Lochinvar boiler error code E00 mean?
E00 (Invalid Lockout) means the boiler’s control has locked out and cannot match the lockout to a defined fault condition, which points to an internal control fault. Confirm that meaning against the manual for your unit. In practice the burner will not fire, so you lose heat and possibly hot water until it is diagnosed.
Can I reset a Lochinvar boiler showing E00?
Yes, once, if the owner manual allows it: switch the boiler off at its service switch, wait about a minute and switch it back on. If E00 comes back, stop resetting and call a licensed gas technician. Repeated resets on an unexplained lockout can hide a real fault and do not fix anything.
Is it safe to run my Lochinvar boiler after E00 clears?
If a single power cycle clears it and the boiler runs normally, it is generally reasonable to keep using it while you watch for a repeat. If E00 returns, or you notice gas odour, a carbon monoxide alarm, water under the boiler or scorch marks, shut it off and get it checked. For gas odour or a CO alarm, leave the house and call FortisBC or 911 from outside.
Does E00 on a Lochinvar boiler always mean a new control board?
No. Power problems, loose or corroded connections, moisture near the electronics and corrupted settings can all produce an unexplained lockout. A proper diagnosis tests supply voltage, grounding, connections and the surrounding system before condemning the board, which is one of the more expensive parts on a boiler.
Why do I have no hot water with Lochinvar error code E00?
If your hot water comes from an indirect tank heated by the boiler, or from a combi unit, the lockout stops hot water production as well as heat. Stored hot water runs out and the taps go cold. A separate gas tank water heater with its own burner is not affected by the boiler’s lockout.
Who repairs Lochinvar boiler error code E00 near me in Greater Vancouver?
BC Wide repairs Lochinvar boiler lockouts across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor using our own licensed gas fitters, and we book same-day where we can. Call (604) 473-9690.
- Lennox Boiler Code 150 — Fan or fan wiring fault | BC Wide
- Lennox Boiler Code 18 — Gas valve fault | BC Wide
- Lennox Boiler Code 19 — Automatic water refill enabled | BC Wide
- Lennox Boiler Code 20 — Max water refill reached / Central Heating Flow or Flue NTC fault | BC Wide
- Lennox Boiler Code 321 — Domestic hot water NTC sensor fault | BC Wide
- Lennox Boiler Code 384 — False flame detected | BC Wide
- Lennox Boiler Code 385 — Under voltage (low supply voltage) | BC Wide
- Lennox Boiler Code 40 — Central Heating Return NTC fault | BC Wide
- Lennox Boiler Code 50 — Hot Water NTC fault (tank version) | BC Wide
- Lennox Boiler Code 53 — Flue obstruction – combustion off | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.