Lochinvar boiler error code E06 means the outlet water temperature has gone above the setting of the boiler’s automatic-reset high limit (confirm against the manual for your unit). The burner shuts off, the water cools, and the boiler tries again on its own. In practice it almost always points to water not moving through the boiler fast enough: a weak or air-locked circulator, a closed valve, sludge or a drifting sensor. Check power, the thermostat and the pressure gauge, and call (604) 473-9690 if it keeps coming back.
If your Lochinvar boiler is showing E06 (Auto Reset High Limit), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Needs attention.
What E06 means on a Lochinvar boiler
The outlet water temperature has exceeded the setting of the automatic-reset high limit.
Common causes
- Inadequate water flow through the boiler
- Failed or air-locked circulator pump
- Closed valve or system blockage
- Faulty outlet temperature sensor
What you can safely check first
- Check the system pressure gauge and top up via the filling loop to normal pressure if you know how
- Make sure radiator/zone valves are open and the system is not air-locked
- Reset once; if it recurs, have a technician check flow, pump and sensors
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing E06 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E00 — Invalid Lockout
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E07 — Air Pressure Switch
Frequently asked questions
Is E06 on a Lochinvar boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after E06?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar Boiler Error Code E06: what it means for your heat, hot water and safety
In plain terms, E06 is the boiler protecting itself. The control watches the temperature of the water leaving the heat exchanger, and when that water gets hotter than the automatic-reset high limit allows, it shuts the burner down. Because this is an automatic reset rather than a manual one, the boiler does not usually lock you out for good. Once the water cools it fires again, which is why most homeowners describe E06 as heat that comes and goes rather than heat that has stopped completely. The code meaning above is how the existing guide states it; confirm against the manual for your unit, because the wording on the display and in the manual is what counts.
For your comfort, the effect is uneven heat. The burner keeps getting interrupted, so the boiler never delivers a steady supply of warm water to the radiators, baseboard or in-floor loops. Rooms closest to the boiler may feel fine while the far end of the house stays cool. If the boiler also heats an indirect hot water tank, showers can run lukewarm or the tank can take longer to recover after a bath.
For safety, the high limit tripping is actually the safety system doing its job. The concern is the reason behind it. A boiler that repeatedly overheats its own outlet water is working its heat exchanger, gaskets and circulator harder than they were designed for, and rising water temperature also raises system pressure, which can make the relief valve discharge. That is why E06 should be treated as a message that something in the water side of the system needs attention, not as a nuisance to clear and forget.
Here is how E06 usually shows up in owner words. If several of these sound familiar, the flow side of your system is the first place a technician will look.
- The boiler fires, runs for a few minutes, shuts off and shows E06, then starts again on its own a little later.
- Radiators or baseboard near the boiler are very hot, but rooms at the far end of the house or upstairs stay cool.
- In-floor radiant heat feels lukewarm even though the boiler seems to be working hard.
- You hear gurgling, rushing or trickling water in the pipes, which often means air is trapped in the system.
- The circulator pump hums, feels much hotter than usual, or you cannot hear or feel it running at all.
- Hot water from an indirect tank runs out sooner than it used to or takes longer to come back.
- The code appears mostly on cold mornings, when the boiler is firing hardest and only one zone is calling.
- There is water on the floor under the relief valve discharge pipe beside the boiler.
Why is my Lochinvar boiler showing error code E06? Likely causes, most common first
A modern condensing boiler has a compact heat exchanger with narrow water passages and a small volume of water inside it. That design lets it heat quickly and modulate efficiently, but it also means the boiler depends on a steady flow of water to carry the heat away. When flow drops, the water inside the heat exchanger heats up faster than the control can turn the flame down, the outlet temperature overshoots, and the automatic-reset high limit steps in. Almost every E06 we see traces back to that one mechanism, so the list below runs from the most common flow problems to the less common control and sensor issues.
1. A weak, seized or air-locked circulator pump. The pump is the heart of the system. If its impeller is clogged with debris, its bearings are worn, or a pocket of air is sitting in the pump housing, it may run without actually moving enough water. This is the single most common cause of an outlet temperature overshoot on a boiler of this type.
2. Air in the system. Air gets in after a repair, after a pressure drop, through a failed automatic air vent, or when a system has been drained and refilled without being purged properly. Air collects at high points and in the pump, and it blocks flow just as effectively as a closed valve.
3. A closed or partly closed valve. Isolation valves are sometimes left closed after service, zone valves can stick shut, and flow checks can jam. One closed valve in the wrong place can starve the boiler of return water.
4. Sludge and debris restricting flow. Metro Vancouver water is soft, so hydronic problems here are sludge and corrosion rather than limescale. Older steel and cast iron in the system shed fine black oxide that settles in strainers, low spots and the small passages of the heat exchanger. Over time that restriction is enough to trigger E06.
5. A small zone calling on its own. When only one short zone, such as a bathroom loop, calls for heat, the boiler may be firing into a load far smaller than its minimum output. The water has nowhere to send the heat and the outlet temperature climbs. This is a piping and control setup issue rather than a failed part.
6. An outlet temperature sensor or limit device reading incorrectly. A sensor that has drifted, a loose connection or a damaged wire can make the control believe the water is hotter than it is. This is less common than a true flow problem but it does happen, and it is confirmed by measurement, never by guessing.
7. Settings that have been changed. If the operating set point has been raised close to the limit setting, or settings were altered during previous service, normal operation can push the outlet temperature into the limit. Only a technician should review and change control settings.
| Likely cause | What an owner can safely check | When it becomes a licensed call |
|---|---|---|
| Circulator pump weak, seized or air-locked | Listen near the pump for a steady hum and note whether pipes near the boiler are much hotter than pipes further away | Any time the pump is silent, very hot, noisy or the code returns after one reset |
| Air trapped in the system | Listen for gurgling and note the reading on the pressure gauge compared with what the manual or your installer described as normal | If pressure is low or keeps dropping, or the system needs purging, which should be done by a technician |
| Closed or stuck valve | Look for any valve handle that is clearly turned across the pipe after recent work, without forcing anything | If you are not certain which way a valve should sit, or a zone valve seems stuck |
| Sludge and debris from corrosion | Note whether the system has ever been flushed or has a dirt or magnetic separator fitted | Flushing, cleaning strainers and adding treatment is licensed work on a pressurised gas boiler system |
| Small zone calling alone | Note which thermostat was calling when the code appeared and the time of day | Piping changes, buffer tanks or control changes are a technician job |
| Sensor or limit device reading wrong | Nothing beyond noting the code and when it happens | Always; sensors are tested with meters against the manufacturer chart |
| Control settings changed | Do not change settings; just note whether anyone has adjusted them recently | Always; settings are reviewed by the technician during diagnosis |
Can I reset a Lochinvar boiler with error code E06, and what is safe to check first?
Because E06 is an automatic-reset limit, the boiler will usually try again by itself once the water cools. If the owner manual for your unit allows a manual reset, one reset is reasonable. If the code returns, stop there. Repeatedly cycling power or resetting does not fix a flow problem, and it can hide a developing safety issue while the heat exchanger keeps getting overheated.
These are the checks a homeowner can safely make. They involve looking, listening and confirming that the boiler is being asked to run, nothing more.
- Power: confirm the boiler’s service switch is on and the breaker has not tripped. If a breaker has tripped more than once, leave it off and call.
- Gas supply: confirm the gas valve on the supply pipe to the boiler is open, with the handle running in line with the pipe. Do not touch any valve inside the boiler cabinet.
- Thermostat: confirm the thermostat is set to heat, has working batteries if it uses them, and is set above room temperature so it is genuinely calling.
- Reset: one reset only, and only if the owner manual for your unit says a reset is permitted.
- Outside vent terminals: check that the intake and exhaust terminals outside are clear of leaves, snow, ice, plastic or nests. Do not reach into a terminal while the boiler is running.
- Condensate drain: look at the visible condensate drain line and confirm it is not kinked, disconnected or sitting in standing water.
- Pressure gauge: read the gauge and note the number so you can tell the technician. Topping up pressure through the filling loop is something only an owner who has been shown how should do; if in doubt, leave it.
How our Lochinvar boiler error code E06 repair visit works
Here is what a proper E06 diagnosis and repair looks like from our side, step by step, so you know what you should see and what you should get in writing.
The parts most often involved in an E06 repair, in general terms, are the circulator pump, an automatic air vent, a zone valve or its actuator, a flow check, a strainer or separator, and occasionally the outlet temperature sensor or its wiring. A control board is one of the more expensive parts on a boiler and is rarely the true cause of E06, so we do not replace one without a measured reason. Labour for a heat exchanger cleaning or a full system flush is more involved than a pump swap, and the written quote will say which one your system needs and why.
Brands we service on hydronic systems include Lochinvar, IBC, Navien, Viessmann, Weil-McLain, Bosch and Rinnai. We are an independent contractor and service these brands; we are not a factory-authorized dealer or warranty centre for any of them. If your boiler is still under a manufacturer warranty, keep your paperwork handy and we will tell you honestly if a warranty route makes more sense for a particular part.
BC Wide Home Services Ltd is a TSBC-licensed independent contractor that has worked on Greater Vancouver heating systems since 1999 (gas contractor licence LGA0090068, Class B gas licence CGA0028029). Gas work is done by our licensed gas fitters. Where the job requires a permit, such as a boiler replacement or a gas piping alteration, we pull it and the work is open to inspection. You get a written quote before any work beyond diagnosis, and you are never asked to approve a repair that has not been explained.
- Step 1, the call: when you phone (604) 473-9690 we ask when E06 appears, which zones were calling, what the pressure gauge reads and whether anyone has worked on the system recently. We offer same-day where we can, and we tell you honestly when we cannot.
- Step 2, safety first: on arrival the technician checks for gas leaks around the boiler, takes an ambient carbon monoxide reading, and looks over the venting and the outside terminals.
- Step 3, fault history: the boiler control stores recent faults, so we read the history to see how often E06 has occurred and under what conditions.
- Step 4, measurement: we measure supply and return temperatures to see how much the water heats up as it passes through the boiler, check pump operation and current draw, read system pressure, and test the outlet sensor against the manufacturer’s resistance chart. Combustion is checked with an analyser.
- Step 5, find the cause: the readings tell us whether the problem is flow, air, sludge, piping, a sensor or a setting. We explain what we found in plain language.
- Step 6, written quote: before any work beyond diagnosis, you receive a written quote naming the fault, the parts and the labour involved.
- Step 7, the repair: once approved, we complete the work, purge air properly, and restore pressure to the correct level for your system.
- Step 8, test the safeties: we run the boiler through a full heat call on each zone, confirm the high limit and other safeties respond correctly, and confirm the outlet temperature stays where it should.
- Step 9, paperwork: you get a written record of what was found, what was done, and anything we recommend watching.
Should I repair or replace an older Lochinvar boiler that keeps showing E06?
In most cases, E06 is a system problem rather than a boiler problem. The boiler is reporting that water is not carrying heat away fast enough, and the cause usually lives in the pump, valves, air or sludge outside the cabinet. Replacing the boiler without fixing that cause simply moves the same fault onto a new appliance, and a new compact heat exchanger can be fouled by an old dirty system just as quickly.
Replacement starts to make sense when the heat exchanger itself is badly fouled or damaged, when the boiler has a history of repeated failures across several systems, when parts for an older control have become hard to source, or when the house has changed so much through renovations that the boiler is now badly matched to the load. In those cases we will lay out both options side by side in writing, with the reasons, and let you decide. Any replacement is permitted gas work and includes a proper system flush, separator and treatment so the new boiler starts in clean water.
| Situation | Usually points toward | Why |
|---|---|---|
| Pump, air vent or zone valve found faulty | Repair | The boiler is fine; a single component is starving it of flow |
| Sludge in strainers and piping, heat exchanger still clean | Repair with flush and separator | Cleaning the system removes the restriction and protects the boiler |
| Heat exchanger heavily fouled or damaged | Discuss replacement | A damaged exchanger is one of the most expensive parts and limits remaining life |
| Repeated faults across several systems over recent seasons | Discuss replacement | Ongoing repairs may no longer be a sensible use of money |
| Small zones short-cycling after a renovation | Repair through piping or control changes | The boiler is mismatched to the zones, not worn out |
| Control parts difficult to source for an older unit | Discuss replacement | Long waits for parts mean long periods without reliable heat |
Lochinvar boiler error code E06 service near you across Greater Vancouver
We diagnose and repair E06 faults on Lochinvar boilers in Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Timing depends on the day’s workload and how far you are from our Burnaby base; we offer same-day where we can, and we never promise a guaranteed arrival window.
Housing stock shapes how this fault shows up. In older parts of Vancouver, Burnaby and New Westminster, many homes have had a modern condensing boiler connected to radiators and piping that were originally installed for a much older boiler. That older pipework often carries years of corrosion sludge, and a compact heat exchanger is far less forgiving of it, which is a classic route to E06. Our soft coastal water means the culprit is usually black oxide sludge rather than scale.
On the North Shore and in parts of Coquitlam and Port Moody, larger hillside homes often run several heating zones on different floors, and high points in the piping make trapped air more likely. In newer subdivisions in Surrey and Langley, in-floor radiant systems with long loops and mixing controls are common, and a single small zone calling on a mild day can push a boiler into its limit. Townhouses and strata homes in Richmond, Delta and across the region often have boilers in tight closets where pumps and valves are hard to reach, and in strata buildings we confirm with the owner whether any work needs strata approval before we start.
Our mild, wet climate also matters. Boilers here spend much of the year running at low load during the shoulder seasons, which is exactly when small-zone overshoot happens. Fallen leaves and the occasional snowfall can also block outside vent terminals, so keep them clear through autumn and winter.
If you smell gas or your carbon monoxide alarm sounds at any point, leave the house immediately and call FortisBC or 911 from outside. Do not operate switches or try to reset the boiler. Every home with a gas boiler should have working carbon monoxide alarms on each level and near sleeping areas. For everything else about E06, call (604) 473-9690 and a licensed technician will walk you through next steps.
More questions homeowners ask
What does Lochinvar boiler error code E06 mean?
E06 means the outlet water temperature has exceeded the setting of the boiler’s automatic-reset high limit, so the burner shuts off until the water cools. Confirm against the manual for your unit. It usually points to poor water flow through the boiler from a pump, air, a closed valve or sludge, rather than a failed boiler.
Can I reset a Lochinvar boiler showing E06?
The boiler normally resets itself once the water cools, because E06 is an automatic-reset limit. If your owner manual permits a manual reset, try it once only. If the code comes back, stop resetting and book a licensed technician, because the cause will keep recurring until the flow problem is fixed.
Is it safe to run a Lochinvar boiler with error code E06?
The high limit is doing its job by shutting the burner down, so the boiler is protecting itself in the short term. Running it for weeks while it keeps overheating its own outlet water stresses the heat exchanger, gaskets and pump and can make the relief valve discharge. If you smell gas or a carbon monoxide alarm sounds, leave the house and call FortisBC or 911 from outside.
Why does my Lochinvar boiler show E06 mostly on cold mornings?
Cold mornings are when the boiler fires hardest, so any shortfall in flow shows up as a fast temperature rise at the outlet. It is also common when only one small zone is calling and the boiler has nowhere to send its heat. A technician can measure the temperature rise across the boiler and check zoning and pump operation to confirm which it is.
Will flushing the system fix Lochinvar boiler error code E06?
A flush fixes E06 when sludge is the real cause, which is common in Metro Vancouver because our soft water leads to corrosion sludge rather than scale. It will not fix a failed pump, a stuck valve or a faulty sensor. That is why we measure first and put the recommended repair in a written quote before doing any work.
Who repairs Lochinvar boiler error code E06 near me in Greater Vancouver?
BC Wide Home Services Ltd is an independent TSBC-licensed contractor that services Lochinvar boilers across Vancouver, Burnaby, Surrey, Richmond, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are not a factory-authorized dealer, but our licensed gas fitters diagnose and repair the brand. Call (604) 473-9690; we offer same-day where we can.
- Lennox Boiler Code 150 — Fan or fan wiring fault | BC Wide
- Lennox Boiler Code 18 — Gas valve fault | BC Wide
- Lennox Boiler Code 19 — Automatic water refill enabled | BC Wide
- Lennox Boiler Code 20 — Max water refill reached / Central Heating Flow or Flue NTC fault | BC Wide
- Lennox Boiler Code 321 — Domestic hot water NTC sensor fault | BC Wide
- Lennox Boiler Code 384 — False flame detected | BC Wide
- Lennox Boiler Code 385 — Under voltage (low supply voltage) | BC Wide
- Lennox Boiler Code 40 — Central Heating Return NTC fault | BC Wide
- Lennox Boiler Code 50 — Hot Water NTC fault (tank version) | BC Wide
- Lennox Boiler Code 53 — Flue obstruction – combustion off | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.