Lochinvar boiler error code E13 means the flue (vent) temperature has gone past its limit and the boiler has locked out to protect the venting, so expect no heat and, with an indirect tank, no hot water. Check power, the gas valve, the thermostat call, system pressure and the outside vent terminals, then reset once only if your manual allows it. If E13 returns, call a licensed gas technician: the usual causes are poor water flow, a fouled heat exchanger, combustion or the flue sensor. Confirm against your unit’s manual.
If your Lochinvar boiler is showing E13 (Flue Temperature Limit), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Critical — likely no heat / lockout.
What E13 means on a Lochinvar boiler
The flue (vent) temperature has exceeded its limit and the boiler has locked out.
Common causes
- Scaled or fouled heat exchanger
- Restricted water flow
- Combustion problem
- Faulty flue temperature sensor
What you can safely check first
- Check that system pressure is normal and flow is not restricted
- Reset once; recurring flue over-temperature requires a technician to inspect the heat exchanger and combustion
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing E13 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E00 — Invalid Lockout
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E06 — Auto Reset High Limit
Frequently asked questions
Is E13 on a Lochinvar boiler serious?
It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after E13?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar boiler error code E13: what it means for your heat, hot water and safety
In plain words, E13 means the boiler shut itself down because the exhaust leaving it got hotter than it is allowed to. The flue temperature limit is a safety, not a comfort setting. Many residential Lochinvar boilers are condensing models, and a condensing boiler normally sends out relatively cool exhaust because it pulls so much heat out of the flue gas before it leaves. When the flue sensor reports exhaust that is too hot, the control reads it as a sign that heat is not moving into the boiler water the way it should, and it locks the burner out rather than risk overheating the vent pipe or the heat exchanger. Control generations differ, so confirm the exact meaning against the manual for your unit.
For you, that usually shows up as one or more of these, in the words homeowners use when they call us:
- The house is cooling off and the radiators, fin-tube convectors or in-floor loops feel lukewarm or cold.
- Hot water runs out or never gets hot, if your domestic hot water comes from an indirect tank heated by the boiler.
- The display shows E13 and the boiler will not relight on its own.
- The boiler fired hard for a long time, then went quiet, often during a long run on a cold night.
- The code clears with a reset but comes back hours or days later.
- The pressure gauge reads lower than you normally see, or you hear gurgling or rushing water in the pipes.
- The vent pipe near the boiler feels unusually hot, looks discoloured or sags, or there is a hot plastic smell in the mechanical room.
Lochinvar boiler error code E13: what we check first, most likely cause to least
This is the order our licensed gas fitters work in on a Lochinvar E13 call in Greater Vancouver. Every cause on the list explains the same thing: heat from the burner is not being carried away by the boiler water, so it leaves through the flue instead. We rank them by how often we find them, and we prove each one with readings before anything is replaced.
- 1. Poor water flow through the boiler. This is the most common reason we find. If water does not move through the heat exchanger fast enough, the burner heat has nowhere to go and the exhaust runs hot. Typical culprits are a circulator pump that is weak, seized or not getting power, air trapped at a high point, an isolation valve left closed or half closed after earlier work, a clogged strainer or dirt separator, and near-boiler piping that was never set up for the flow the boiler needs. Owner check: look at the pressure gauge and listen for gurgling. Licensed call: the pump, valves, purging and any piping.
- 2. A fouled heat exchanger. Metro Vancouver water is soft, so we rarely see hard-water limescale here. What we do see is black iron-oxide sludge and corrosion debris, usually from older radiators and steel piping that were never cleaned or treated when a newer boiler went in. That sludge coats the water side and chokes flow. On the fire side, combustion deposits and debris build up when yearly maintenance is skipped. Either way heat stops transferring and the flue runs hot. Owner check: note when the boiler was last serviced. Licensed call: cleaning, flushing and water treatment.
- 3. Combustion out of adjustment. If the boiler is over-firing, the gas input is off, or the air-fuel mix has drifted, the flame can produce more heat than the heat exchanger absorbs. A partly blocked intake or exhaust terminal can upset combustion too. Owner check: make sure the outside terminals are clear. Licensed call: gas pressure, combustion analysis and any adjustment, which is licensed gas work in BC.
- 4. A failing flue temperature sensor or its wiring. Sensors drift, connectors corrode and wires get pinched or heat-damaged. A bad sensor can report hot exhaust that is not really there. We rank this fourth on purpose: we confirm the reading is wrong with our own instruments before we replace a sensor, because swapping a sensor that was telling the truth only hides a real overheating problem.
- 5. Settings or system changes. A boiler set up for one heating layout that later had zones added or removed, an indirect tank piped in, or control settings changed can end up running in a way that pushes flue temperatures up. We review settings and recent changes last, once the hardware checks out.
| Likely cause | What you may notice | What the owner can safely check | When it becomes a licensed call |
|---|---|---|---|
| Poor water flow (pump, air, valves, strainer) | Gurgling, low pressure, some rooms cold while the boiler runs hard | Read the pressure gauge, listen for air, note any recent work on the system | Any pump, valve, purging or piping work |
| Fouled heat exchanger (sludge or combustion deposits) | E13 on long runs, dark water seen during past service, no maintenance in years | Check service records and the date of the last cleaning | Always: flushing, cleaning and water treatment are technician work |
| Combustion out of adjustment | Louder or rougher firing, heavier exhaust plume outside | Clear snow, leaves or nests from the outside terminals by hand | Gas pressure, combustion testing and adjustment are licensed gas work |
| Flue temperature sensor or wiring | E13 at odd times, even on short or mild runs | Nothing inside the cabinet; note when the code appears | Testing and replacing the sensor and its harness |
| Settings or system changes | E13 started after a renovation, new zone or new indirect tank | Write down what changed and when | Reviewing control settings and the piping layout |
Can I reset a Lochinvar boiler showing E13? Owner-safe steps in order
Yes, once, and only if the owner’s manual for your boiler allows a reset. Before that single reset, work through these checks. None of them involve opening the boiler, and all of them help the technician who comes next.
- Power: make sure the service switch near the boiler is on and the breaker has not tripped. Do not open the boiler cabinet or any electrical box.
- Gas: confirm the manual shut-off valve on the gas line to the boiler is open, with the handle in line with the pipe. If you find it closed and do not know why, leave it closed and call us, because someone may have shut it for a reason. Do not loosen, adjust or relight anything on the gas line.
- Call for heat: make sure a thermostat is actually calling for heat by turning it up a few degrees, or that the indirect tank is calling for hot water.
- Pressure: read the boiler pressure gauge. If it is well below where it normally sits, write that down for the technician. Only top up the system if your manual describes it as an owner task; if it does not, leave it for us.
- Outside terminals: go outside and look at the intake and exhaust terminals. With the boiler off, clear snow, wet leaves, a wasp or bird nest, or anything stacked against them, by hand, from outside. Do not pull, twist or disconnect the vent pipe.
- Condensate: look at the visible condensate drain line and trap without opening anything. A kinked, frozen or overflowing line is worth reporting.
- Reset once: if the manual allows it, reset a single time. Note whether E13 comes back and roughly how long it took. That timing is useful diagnostic information.
When E13 stops being an owner job, and the safety line you should never cross
If E13 returns after your one reset, stop there. Do not keep resetting and do not cycle the power to clear the code. Every reset lets the boiler fire again into the same fault, and repeated overheating is exactly what damages plastic venting and heat exchangers. Never bypass, jumper or unplug the flue sensor to get heat back. The flue temperature limit is the only thing standing between hot exhaust and the vent pipe that carries it out of your home.
In BC, work on the gas train, burner, combustion settings and venting is licensed gas work under Technical Safety BC rules, and line-voltage wiring belongs to a licensed trade as well. A homeowner may look, listen, clear the outside terminals by hand and reset once where the manual allows. Opening the burner compartment, testing sensors, adjusting gas pressure, purging air from the piping, changing the pump and flushing the system are all for a licensed technician.
Gas and carbon monoxide safety: a boiler locked out on E13 is not burning gas, but the cause still matters. Overheated exhaust can soften or crack plastic vent pipe and loosen joints, and a damaged vent can leak flue gas into the house. If you smell gas or a carbon monoxide alarm sounds, leave the home now and call FortisBC or 911 from outside. Do not reset the boiler, do not flip switches and do not go back in until you are told it is safe. Every home with a gas boiler should have working carbon monoxide alarms near the sleeping areas.
While you wait for a technician, keep the house warm safely: close doors to unused rooms, add layers and keep blinds shut at night. Never use a gas range or oven to heat the home.
How our Lochinvar boiler E13 repair visit works, step by step
Diagnostic service calls are $189.00. That covers the visit and a proper diagnosis by a licensed gas fitter. Any repair work beyond the diagnosis is quoted in writing before it starts, and you decide whether to go ahead.
- 1. You call (604) 473-9690 and tell us the code, what you already checked and whether it came back after one reset. We book same-day where we can. During cold snaps that is not always possible, and we will tell you honestly what the next opening is rather than promise an arrival window.
- 2. On arrival, the technician reads the lockout history and any stored readings the control keeps, and confirms the code against the manual for that specific unit.
- 3. We measure rather than guess: a combustion analyzer at the flue, a manometer on the gas supply, a multimeter on the flue sensor and its circuit, and temperature readings across the supply and return piping to judge whether water is really moving.
- 4. We check the circulator, isolation valves, strainer or dirt separator, air elimination and system pressure, and we look at the boiler water itself. Dark, sludgy water tells us a lot about the heat exchanger.
- 5. Where the readings point to it, we inspect the heat exchanger and burner, and we walk the vent run looking for heat damage, sagging, discolouration and poor joints.
- 6. You get a written quote that names the fault, the parts most likely involved and the labour, before any work beyond diagnosis.
- 7. After the repair we test the safeties: we confirm the flue sensor reads correctly, run the boiler through full heating and hot-water cycles, re-check combustion and confirm it modulates down without returning to E13.
- 8. You get a written record of what we found, what we measured and what we did, which is worth keeping for future service and resale.
Should I repair or replace an older Lochinvar boiler that keeps showing E13?
Most E13 lockouts are repairable. The parts most often involved, in general terms, are the circulator pump, the flue temperature sensor or its harness, burner and ignition components after a combustion problem, and the labour and materials for a heat exchanger cleaning and system flush with proper water treatment and a dirt separator. A control board is one of the more expensive parts on a boiler and is rarely the real cause of E13, so we do not jump to it. Replacement becomes a real conversation when the heat exchanger itself is damaged, when an older boiler has a history of repeat lockouts, or when the original installation was never right for the house.
The only free service BC Wide offers is the in-home estimate for replacing or installing equipment. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. A proper replacement quote should show, in writing, how the boiler was sized for your home, the venting route and terminal locations, whether the gas line is adequate, how the old system will be cleaned and treated before the new boiler is connected, and who pulls the gas permit.
| Situation | Repair usually makes sense when | Replacement deserves a look when |
|---|---|---|
| Heat exchanger condition | It is fouled but sound, and cleaning restores heat transfer | It is cracked, corroded through or badly deformed from overheating |
| Lockout history | This is the first E13 or the first in a long time | E13 and other lockouts keep returning despite earlier repairs |
| System water | Sludge can be flushed and the system treated and protected | Old piping keeps shedding debris and the boiler has already suffered from it |
| Parts availability | The needed parts are readily available for your unit | Key parts are hard to source for an older control generation |
| Venting | The vent run is undamaged and meets current requirements | The vent was heat-damaged or would need rerouting anyway |
| Fit for the home | The boiler heats the home well when it is working | It was oversized or undersized, or the home has changed a lot since |
Lochinvar boiler error code E13 repair near you in Greater Vancouver
We service Lochinvar boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock shapes how E13 shows up. In older parts of Vancouver, Burnaby, New Westminster and the North Shore, we often find newer condensing boilers connected to original radiators and steel piping, which is where much of the sludge behind flow-related E13 comes from. In townhouse and strata buildings across Burnaby, Coquitlam, Richmond and Surrey, vent runs can be long or terminate close to a neighbour’s wall or a balcony, so we pay close attention to vent condition, and any change to the vent route may need strata council approval. Newer homes in Surrey, Langley, Delta and Richmond more often have in-floor radiant heat, where mixing valves and zone settings play a bigger part.
Our mild, wet coastal climate means boilers here spend long stretches running gently, then work hard during the short cold snaps we get most winters. Those hard runs are when a marginal pump or a partly fouled heat exchanger tends to tip over into E13. Wet leaves in fall and the occasional heavy snowfall can also block low vent terminals.
Boiler brands we service include Lochinvar, IBC, Navien, Viessmann, Weil-McLain, Buderus, Triangle Tube, Bosch and Rinnai. These are brands we service as an independent contractor. We are not an authorised dealer or warranty centre for any of them, so if your boiler may still be covered by the manufacturer, keep your paperwork and installation records handy when you call.
- TSBC-licensed independent contractor serving Metro Vancouver since 1999: gas contractor licence LGA0090068, Class B gas licence CGA0028029.
- Our own licensed gas fitters do the diagnosis and the repair.
- Gas permits pulled and inspections arranged wherever the work requires them.
- A written quote before any work beyond diagnosis, and a written record of what was done.
- Honest timing: same-day where we can, and a straight answer when we cannot. Call (604) 473-9690.
More questions homeowners ask
What does error code E13 mean on a Lochinvar boiler?
E13 is the Flue Temperature Limit: the flue (vent) temperature has exceeded its limit and the boiler has locked out. In practice it means heat from the burner is leaving through the exhaust instead of going into the boiler water, most often because of poor water flow or a fouled heat exchanger. Confirm the meaning against the manual for your unit.
Can I reset a Lochinvar boiler E13 myself?
You can reset once, and only if your owner’s manual allows it, after checking power, the gas valve, the thermostat call, system pressure and the outside vent terminals. If E13 returns, stop and call a licensed gas technician. Repeated resets let the boiler keep overheating its exhaust, which can damage the vent pipe and the heat exchanger.
Is it safe to run my Lochinvar boiler after an E13 code?
Not if the code keeps coming back. A boiler that repeatedly hits its flue temperature limit is running in a way that can soften or crack plastic venting and let flue gas into the home. If you smell gas or a carbon monoxide alarm sounds, leave the home and call FortisBC or 911 from outside.
Why does my Lochinvar boiler keep going to E13 on cold nights?
Cold nights are when the boiler fires hardest and longest, so a weak circulator, trapped air or a partly fouled heat exchanger shows up then. In Metro Vancouver the fouling is usually iron-oxide sludge from older piping rather than hard-water scale. A technician can measure flow and combustion to find which one it is.
Can a dirty heat exchanger cause E13 on a Lochinvar boiler?
Yes. Sludge on the water side or combustion deposits on the fire side stop heat moving into the boiler water, so more of it leaves through the flue. The fix is a professional cleaning and system flush, followed by water treatment and usually a dirt separator so the problem does not come straight back.
Who repairs Lochinvar boiler error code E13 near me in Greater Vancouver?
BC Wide Home Services Ltd repairs Lochinvar boilers across Vancouver, Burnaby, Surrey, Richmond, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor, not a dealer, and our licensed gas fitters give you a written quote before any work beyond diagnosis. Call (604) 473-9690; we book same-day where we can.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
- Lochinvar Boiler Code E23 — Inlet Sensor Short | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.