Quick answer

Lochinvar boiler error code E19 means the flue (vent) temperature sensor circuit is reading open or shorted, so the control cannot trust the exhaust temperature and stops the burner. Confirm the meaning against the manual for your unit. Expect no heat and, on many systems, no hot water until it is repaired. It is not an owner repair: check power, the gas valve and the thermostat, reset once only if your manual allows it, then book a licensed gas technician at (604) 473-9690.

If your Lochinvar boiler is showing E19 (Flue Sensor Open/Short), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.

Severity: Needs attention.

What E19 means on a Lochinvar boiler

The flue (vent) temperature sensor circuit is reading open or shorted.

Common causes

  • Faulty flue temperature sensor
  • Damaged or disconnected sensor wiring
  • Control board fault

What you can safely check first

  1. No safe homeowner action — this is an internal sensor fault
  2. Call a technician to test and replace the flue sensor

Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.

When to call a technician

This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.

BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.

Lochinvar boiler repair across Greater Vancouver

If a Lochinvar boiler showing E19 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.

Related Lochinvar boiler codes

Frequently asked questions

Is E19 on a Lochinvar boiler serious?

It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.

How do I reset a Lochinvar boiler after E19?

You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.

Lochinvar boiler error code E19: what it means for your heat and hot water

In plain terms, the flue temperature sensor is the boiler’s thermometer on the exhaust side. The control board watches it continuously so it can tell whether the flue gases are running hotter than the venting is designed to handle. When the board sees an open or shorted reading on that circuit, it no longer has a number it can trust, and a well-designed control does the cautious thing: it stops firing the burner and posts E19. That is the boiler protecting the vent, the house and the people in it, not a random glitch. Confirm the exact meaning against the manual for your unit, because display wording differs between control generations.

What it means for you depends on how your system is piped. If the boiler only heats radiators, hydronic baseboard loops or in-floor tubing, the house will slowly cool once the code appears. If the same boiler also heats an indirect hot water tank, which is common in Metro Vancouver hydronic homes, hot water will run out as the stored supply is used up. Circulator pumps may still run for a short time after the burner stops, so you may hear the system working while the rooms keep cooling.

From a safety standpoint, E19 on its own does not mean there is carbon monoxide in your home. It means one of the safeties that watches the exhaust has lost its signal. Treat it seriously, leave the burner off, and do not try to keep the boiler running with repeated resets. Here is what owners usually describe when they call us about it:

  • The boiler display shows E19 and the burner will not light.
  • Radiators, baseboards or heated floors are lukewarm or cold.
  • Hot water from an indirect tank runs out sooner than usual or goes cold.
  • The boiler restarts after a power cycle, then shows E19 again within minutes or hours.
  • The code comes and goes, often after a long run on a cold, wet morning.
  • There is water, rust staining or a damp smell near the top of the boiler or around the vent connection.

Lochinvar boiler error code E19: likely causes, most common first

These are the causes we see most when a Lochinvar boiler reports a flue sensor open or short, listed from most to least common. Each one includes what you can safely look at yourself and the point where it becomes work for a licensed technician. None of these causes is something a homeowner should repair. The owner checks are about ruling out the basics and giving the technician a clear history of what happened.

1. The flue temperature sensor itself has failed. On a condensing boiler the sensor lives in a warm, wet exhaust stream, and sensors age. The internal element can open, or its insulation can break down and short. Owner check: none on the sensor itself. Note when the code first appeared and whether it comes and goes. Licensed call: the technician measures the sensor against the manufacturer’s published values and replaces it with the correct part if it is out of range.

2. A loose, corroded or wet sensor connection. The sensor connects to the control through a small plug and wiring harness. Condensate, a weeping vent joint or an old leak can corrode the terminals, and a plug can work loose from vibration or after an earlier service visit. Owner check: from outside the cabinet only, look for water, drips or rust staining around the top of the boiler, the vent pipe connection and the condensate drain. Do not remove the cover. Licensed call: cleaning or replacing the connector and finding where the moisture is coming from.

3. Damaged wiring between the sensor and the control. Wiring can chafe on sheet metal edges, get pinched when a panel is refitted, or be damaged by heat if it was routed poorly. Owner check: none inside the cabinet. Tell us if anyone has worked on the boiler recently. Licensed call: continuity and short-to-ground checks on the harness, then repair or replacement.

4. A control board fault. This is the least common cause, but the board is what reads the sensor, and a failed input on the board can look exactly like a failed sensor. Owner check: none. Licensed call: a board is only condemned after the sensor and wiring test good, because a control board is one of the more expensive parts on a modern boiler and should never be replaced on a guess.

A note on vent terminals and the condensate drain: a blocked terminal or a backed-up condensate trap usually trips other safeties rather than a sensor open or short. Backed-up condensate and water in the vent can, however, wet the sensor connection and lead to cause 2, which is why both are part of the owner checks in the table below.

Owner-safe checkWhat you are looking forStop and call when
Power and boiler service switchSwitch on, breaker not tripped, display litThe breaker trips again or the display stays dark
Gas supply valve at the boilerValve handle in line with the pipe, meaning openYou smell gas at any point: leave and call from outside
Thermostat or zone callSet above room temperature, in heat mode, batteries freshThe thermostat is calling but E19 is still on the display
One reset, only if your manual allows itThe code clears and stays clear through a full heating cycleE19 comes back: do not keep resetting
Outside intake and exhaust terminalsClear of snow, leaves, nests or a new obstructionA terminal is damaged, disconnected or keeps icing
Visible condensate drain lineNot kinked or frozen, no water pooling under the boilerWater is pooling under or leaking from the cabinet

How our Lochinvar boiler E19 repair visit works, step by step

Diagnostic service calls are $189.00. That covers a licensed gas technician coming to your home and finding the actual cause of the E19, not guessing at it. Here is what the visit looks like from your side.

  • Step 1, the call: we ask for the code, when it started, whether it clears with a reset, whether the boiler also heats your hot water, and whether anyone has worked on it recently. Same-day where we can, depending on the day’s schedule, and we will tell you honestly if it has to be the next available slot.
  • Step 2, safety first: a gas odour check at the appliance and piping, a look at the combustion air and the area around the boiler, and a visual check of the vent from the boiler to the outside terminal.
  • Step 3, read the control: where your model stores a fault history, we read it so we know whether E19 is new or recurring and what else has been logged alongside it.
  • Step 4, test with meters, not parts: the flue sensor is measured against the manufacturer’s published values, the connector and harness are checked for continuity and shorts, and the control input is confirmed. This step is what separates a sensor problem from a wiring or board problem.
  • Step 5, find the reason: if moisture caused the fault, we trace where the water came from, such as a vent joint, the condensate trap or the drain line, because a new sensor in a wet connector will fail again.
  • Step 6, a written quote before any work beyond diagnosis: you see the part, the labour and what it fixes in writing, and nothing proceeds without your approval.
  • Step 7, repair and prove it: after the repair we fire the boiler, watch it through a full cycle, confirm the flue sensor reading rises sensibly as the exhaust warms, check combustion and test the safeties before we leave.

Repair or replace: is an older Lochinvar boiler with E19 worth fixing?

For most boilers, E19 is a repairable fault. A flue sensor or connector is a modest repair relative to the value of the boiler, and a sound boiler with a healthy heat exchanger should simply be fixed. We say that plainly because the code alone is not a reason to replace anything.

The picture changes when E19 is one of several problems on an older unit. On the visit we look at the condition of the heat exchanger, corrosion inside the cabinet, how often the boiler has needed repairs, whether parts for your control generation are still readily available, and whether the boiler was sized correctly for the house in the first place. If the honest answer is that the boiler is near the end of its life, we will tell you, and we will still put the repair option in writing so the choice stays yours.

If you decide to replace, the in-home estimate for a replacement or new installation is free, and if you go ahead with a replacement or installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.

Boiler brands we service include Lochinvar, IBC, Viessmann, Weil-McLain, Navien, Rinnai and Bosch. We are an independent TSBC-licensed contractor, not a dealer, warranty centre or factory service agent for any of them, so a replacement recommendation is based on your house, your piping and your hot water needs rather than on a brand we have to sell. A proper replacement quote should show you, in writing:

  • The boiler and any indirect tank or controls being proposed, by brand and product family
  • The venting plan: route, terminal location and required clearances
  • Any gas piping changes, if the line has to be re-sized or re-run for the new boiler
  • The condensate drain and neutralizer arrangement
  • The gas permit and inspection through Technical Safety BC
  • What is removed and disposed of, and what warranty registration you are responsible for

Lochinvar boiler error code E19 service across Greater Vancouver

We repair Lochinvar boilers showing E19 across Greater Vancouver: Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Our shop is in Burnaby, which keeps travel reasonable across most of the region, but we never promise a fixed arrival window.

Housing stock shapes these calls. In Vancouver, Burnaby and New Westminster, many older homes have had an older boiler replaced with a modern condensing unit, and the vent often runs through a sidewall or a tight chase that was never planned for one. On the North Shore and in parts of Coquitlam, homes built on slopes can have long or awkward vent runs. In Surrey, Delta, Langley and Richmond, newer detached homes and townhouses often run in-floor heat and an indirect tank off the same boiler, so an E19 stops both heat and hot water at once. In strata buildings, vent terminals and condensate routes may sit on common property, which can mean coordinating with the strata or property manager before work starts. These are general patterns, not rules, and every house is checked on its own merits.

Our climate matters too. Metro Vancouver’s mild, wet coastal winters mean long, steady heating seasons with a lot of condensing operation, which pushes constant moisture through the vent and condensate system. Rain driven against a sidewall terminal, autumn leaves and the occasional snowfall on a low terminal are all things we see. Our water is soft, so on the hydronic side we look for sludge and corrosion rather than hard-water limescale, and we will flag it if dirty system water is part of a wider problem.

Why homeowners call BC Wide for a Lochinvar E19, and when it becomes a licensed call

BC Wide Home Services has worked on Metro Vancouver heating systems since 1999. We are an independent contractor licensed by Technical Safety BC, gas contractor licence LGA0090068, Class B gas licence CGA0028029, and the diagnosis and repair are done by our own licensed gas fitters.

It becomes a licensed call the moment the owner checks are done and E19 is still on the display, or straight away if it returns after one reset. In BC, gas appliance work and most electrical work inside the boiler are restricted to licensed trades, so do not open the cabinet, unplug or jumper the sensor, or bypass anything to get heat back. A jumpered flue sensor removes the boiler’s protection against overheated exhaust and can put the vent and your household at risk.

Gas and carbon monoxide safety: if you smell gas or your carbon monoxide alarm sounds, leave the house right away, do not operate switches, and call FortisBC or 911 from outside. Every home with a gas boiler should have working CO alarms near sleeping areas and on each level, tested regularly. Once the house is safe, call BC Wide at (604) 473-9690.

  • Licensed gas technicians do the work; nobody unlicensed opens the gas train, burner compartment or control wiring.
  • Gas permits and inspections are taken out wherever the work requires them, such as a boiler replacement or gas piping change.
  • A written quote comes before any work beyond the diagnosis, so there are no surprises on the invoice.
  • Honest timing: same-day where we can, and a straight answer when we cannot.
  • Independent advice: we service many brands and recommend what fits the house, not what a supplier wants sold.

More questions homeowners ask

What does Lochinvar boiler error code E19 mean?

E19 means the boiler’s flue (vent) temperature sensor circuit is reading open or shorted, so the control cannot trust the exhaust temperature and stops the burner. Confirm the meaning against the manual for your unit. The cause is usually the sensor, its connector or its wiring, and less often the control board.

Can I reset a Lochinvar boiler showing E19?

Only if your owner manual allows a reset, and only once. If E19 comes back, stop resetting, because repeated resets can hide a real fault and will not repair a sensor circuit. Leave the burner off and book a licensed gas technician.

Is it safe to run my Lochinvar boiler with an E19 code?

The boiler is designed not to fire while E19 is active, and you should not try to force it. Never jumper or bypass the flue sensor to get heat back. E19 alone does not mean carbon monoxide is present, but if a CO alarm sounds or you smell gas, leave and call FortisBC or 911 from outside.

Who fixes Lochinvar boiler error code E19 near me in Greater Vancouver?

BC Wide’s licensed gas technicians repair Lochinvar boilers showing E19 across Vancouver, Burnaby, Surrey, Richmond, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor, not a factory service centre. Call (604) 473-9690; same-day where we can.

Will a new flue sensor fix E19 for good?

Usually, when the sensor itself has failed and the connection is dry and sound. If moisture from a vent joint or condensate problem caused the fault, a new sensor on its own may fail again, so we trace the source of any water before closing the job. If the sensor and wiring test good, the control board is checked next.

Does Lochinvar error code E19 mean I will lose hot water too?

If your Lochinvar boiler also heats an indirect hot water tank, yes, the stored hot water will run out while the boiler is locked out. If your hot water comes from a separate water heater, only space heating is affected. Your technician can confirm how your system is piped during the visit.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a boiler be serviced?
Annual servicing is recommended for all residential boilers. BC Wide's annual service includes combustion analysis, heat exchanger inspection, expansion tank pressure check, condensate trap cleaning, and a full safety check. Annual maintenance is also required to keep most manufacturer warranties valid.
How much does a new boiler cost in Vancouver?
A typical residential high-efficiency gas boiler in Metro Vancouver costs $7,500–$15,000 installed, depending on size, brand, and whether the system is heating only or a combi unit that also handles hot water. BC Wide provides a free written quote with three options at different price points.
How long does a boiler last?
A well-maintained cast-iron boiler can last 25–30 years, a modern high-efficiency condensing boiler typically lasts 15–20 years, and a combi boiler 12–18 years. Annual servicing has the single biggest impact on lifespan.
My boiler is making a banging or kettling noise. Is that dangerous?
Kettling (a banging or whistling sound) is usually caused by limescale build-up on the heat exchanger and is a sign the system is overheating in localised spots. It will not always cause immediate failure but it shortens the life of the boiler and should be addressed within a few weeks.
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Yes. BC Wide is one of the few HVAC companies in the Lower Mainland with deep experience on European and high-end North American boilers including Viessmann, IBC, Baxi, Laars, Weil-McLain, NTI, Navien and Rinnai. We carry common parts in the truck.
Should I repair or replace my old boiler?
A useful rule: if the boiler is more than 15 years old and the repair cost is more than 50% of replacement, replacement is the better investment. BC Wide will give you both a repair quote and a replacement quote and let you decide.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote