Lochinvar boiler error code E21 means the outlet (supply) water temperature sensor circuit is reading open or shorted, so the control can no longer trust the temperature of the water leaving the boiler and will normally hold the burner off until the fault is fixed (confirm against the manual for your unit). It is not a homeowner repair. Check power, the gas valve and the thermostat, reset once only if your manual allows it, then call a licensed gas technician at (604) 473-9690.
If your Lochinvar boiler is showing E21 (Outlet Sensor Open/Short), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Needs attention.
What E21 means on a Lochinvar boiler
The outlet (supply) water temperature sensor circuit is reading open or shorted.
Common causes
- Faulty outlet temperature sensor
- Damaged or disconnected sensor wiring
- Control board fault
What you can safely check first
- No safe homeowner action — this is an internal sensor fault
- Call a technician to test and replace the outlet sensor
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing E21 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E00 — Invalid Lockout
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E06 — Auto Reset High Limit
Frequently asked questions
Is E21 on a Lochinvar boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after E21?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar boiler error code E21: what it means for your heat and hot water
In plain terms, your Lochinvar boiler has a small temperature sensor where heated water leaves the heat exchanger and heads out to your radiators, baseboard convectors or in-floor loops. The control reads that sensor constantly. It uses the reading to decide how hard to fire the burner, when to ease off, and when to stop. E21 tells you the reading itself has gone electrically wrong: either the circuit is broken somewhere (open) or two conductors are touching where they should not (short). It does not mean your water is actually dangerously hot or cold. It means the boiler has lost its eyes on the supply water, so it does the safe thing and stops heating. Confirm the exact meaning and lockout behaviour against the manual for your unit.
That protective shutdown is why the house cools off. If your domestic hot water comes from an indirect tank that the boiler heats, your showers will go lukewarm too. If your hot water comes from a separate water heater, hot water is not affected by this code, only space heating is.
Here is how E21 usually shows up in owner words, the things people tell us on the phone:
- The boiler display shows E21 and the burner will not light, or it lights briefly and shuts down again.
- Radiators, baseboards or heated floors are going cold even though the thermostat is calling for heat.
- You can sometimes hear a pump running but there is no warmth coming through, because the circulator may keep moving water while the burner stays off.
- Hot water runs lukewarm or cold when the tank is heated by the boiler.
- The code appeared after a power interruption, a windstorm outage or a recent service visit.
- The code comes and goes: it clears for a few hours or days and then returns, which often points to a connection rather than a completely dead sensor.
- There is water on the floor under the boiler or a drip near the controls, which can wet the sensor wiring.
Lochinvar boiler error code E21: likely causes, most common first, and what you can safely check
These are listed in the order we generally run into them on Lochinvar boilers in Greater Vancouver homes. It is a ranking from field experience, not a statistic, and your boiler can be the exception.
1. The outlet sensor itself has failed. The sensor is a temperature-dependent resistor that lives through thousands of heating cycles. Over years it can drift, crack internally or fail outright, reading as open or shorted. There is no owner check for this beyond noting that the code is steady and returns immediately after one permitted reset. The technician confirms it by measuring the sensor’s resistance and comparing it with the manufacturer’s resistance-to-temperature chart at the real water temperature.
2. A loose, corroded or partly unseated connector. The plug at the sensor or at the control board can work loose from vibration, from earlier service work, or from corrosion on the pins in a damp mechanical room. This is the classic cause of an E21 that comes and goes. You should not touch the connector yourself; just note whether the code is intermittent, because that detail helps the diagnosis.
3. Damaged sensor wiring. The harness can chafe against sheet metal, get pinched when a panel is refitted, or be damaged by heat if it was routed too close to hot surfaces. In garages and crawlspaces, rodents chewing wiring is a real possibility. Inside the cabinet this is a licensed check; outside it, you can mention to us any signs of mice near the boiler.
4. Moisture at the sensor or connections. A dripping fitting, a weeping relief valve, a condensate leak or very damp air in a basement mechanical room can wet the connections and upset the reading. You can safely look, without opening anything, for water pooling under the boiler, a drip from piping above it, or a condensate line that has come loose or is overflowing.
5. A control board input fault. This is the least common cause and it is only confirmed after the sensor, connectors and harness all test good. The control board is one of the more expensive parts on a modern boiler, so it should never be replaced on a guess. A correct diagnosis proves everything upstream first.
- Power: make sure the boiler’s service switch is on and its breaker has not tripped. You may reset a tripped breaker once; if it trips again, leave it off and call.
- Gas supply: the gas valve handle on the pipe feeding the boiler should sit in line with the pipe (open). Do not operate any other gas valve or fitting.
- Thermostat: confirm it is set to heat, set above room temperature, and has fresh batteries if it uses them.
- Reset: only if your owner manual describes a reset, and only once. If E21 comes back, stop and call. Repeated resets hide the problem and can mask a separate safety issue.
- Outside terminals: from outdoors, check that the intake and exhaust pipes are clear of snow, leaves and nests. Look only; never remove caps or pipe sections.
- Condensate drain: check that the visible drain line is connected and not overflowing or pooling on the floor.
- Write it down: when the code appeared, whether it clears, any recent power outage or service work. That saves diagnostic time.
| Likely cause | What you might notice | What you may safely do | What the licensed technician does |
|---|---|---|---|
| Failed outlet sensor | E21 is steady and returns right after one reset | Note the code and when it started; do not reset repeatedly | Measures sensor resistance against the manufacturer chart at actual water temperature and replaces with the specified part |
| Loose or corroded connector | E21 comes and goes, sometimes after the boiler is bumped or after service | Write down when it appears and clears | Inspects pins and plugs, cleans or replaces the connector, confirms a solid reading |
| Damaged wiring harness | Intermittent or steady E21, sometimes after other work near the boiler | Tell us about rodents or recent work in the area | Tests continuity end to end, repairs or replaces the harness, reroutes it away from heat and sharp edges |
| Moisture on connections | Water under the boiler, a drip from piping, a loose condensate line | Look from outside the cabinet; place a container under an obvious drip | Finds and fixes the water source, dries and protects the connections, then retests |
| Control board input fault | E21 persists even though sensor and wiring are good | Nothing beyond calling for diagnosis | Checks the board input per the manufacturer procedure and replaces the board only once everything upstream is proven |
What you should never do with an E21 code, and the gas and carbon monoxide safety line
Do not open the boiler’s front jacket to get at the burner, gas valve or control wiring. Do not unplug and replug the sensor, jumper any terminals, swap a sensor from another appliance, or install a sensor bought online without knowing it is the manufacturer-specified part. Do not keep cycling power to force the boiler to fire. In British Columbia, gas work must be done by a licensed gas fitter and most electrical work inside the appliance belongs to licensed trades. The owner-safe checks above are the full list of what a homeowner should do.
Gas and carbon monoxide safety: E21 is a sensor fault, not a carbon monoxide warning. But your Lochinvar is a combustion appliance, and any boiler that has been misbehaving deserves a proper combustion check when it is repaired. If you smell gas (a rotten-egg odour) or a carbon monoxide alarm sounds, leave the home immediately with everyone in it, do not operate light switches or appliances on the way out, and call FortisBC or 911 from outside. Keep working carbon monoxide alarms near sleeping areas and near the mechanical room, and test them regularly.
How our Lochinvar boiler E21 repair visit works, step by step
Diagnostic service calls are $189.00. That covers a licensed technician coming to your home, testing the boiler properly and telling you what failed. Nothing beyond diagnosis is done until you have approved a written quote. We book same-day where we can, depending on the day’s workload and where you are, and we will not promise an arrival window we cannot keep.
This is the sequence a correct E21 visit should follow, whoever you hire:
- Booking: tell us the code, what the boiler is doing, whether your hot water is affected, and any recent work or outages. If you can, send a photo of the display and the boiler’s rating plate so we can look at parts before arriving.
- Arrival and safety first: before touching the controls, we check for gas odour, look at the venting and the area around the boiler, and take carbon monoxide readings in the room.
- Read the control: we review the code and any stored fault history the unit keeps, so we know whether E21 is new, recurring or intermittent.
- Meter the sensor: with a digital multimeter we measure the sensor’s resistance and compare it to the manufacturer’s chart at the water temperature we measure separately. A reading that matches the chart clears the sensor; one that is open, shorted or far off condemns it.
- Test the circuit: we check continuity of the harness from sensor to board, inspect connector pins for corrosion or looseness, and look for chafing, heat damage or moisture along the run.
- Prove the board last: only when the sensor and wiring test good do we check the control board’s input following the manufacturer’s procedure. A board is never replaced on suspicion.
- Written quote: you get, in writing, what failed, what part it needs, the labour involved, and whether the part is on our truck or has to be ordered. Work starts only when you approve it.
- Repair: we fit the manufacturer-specified part, route the wiring clear of heat and sharp edges, and fix any water source that contributed to the fault.
- Test the safeties: we confirm the new reading matches the real water temperature, run the boiler through full heating cycles, verify the high-limit and other safety controls respond, perform a combustion check, and confirm the venting and condensate drain are working.
- Hand-over: we explain what we found and what we did, and tell you what to watch for so a recurrence is easy to report.
Repair or replace an older Lochinvar boiler showing E21?
On its own, E21 is rarely a reason to replace a boiler. The outlet sensor and its wiring are small parts compared with the boiler itself, and a correctly diagnosed sensor or connector repair usually puts the boiler back into reliable service. Where the conversation changes is when E21 is one fault among several on a boiler that is already showing its age.
In Metro Vancouver the question usually comes down to the condition of the heat exchanger and the water inside the system. Our water is soft, so hydronic systems here do not tend to suffer from hard-water limescale. What we do see is sludge and corrosion: magnetite and debris that build up over years, especially in older systems with steel piping or radiators, and that can restrict flow through a modern heat exchanger. A boiler that is clean inside with a sensor fault is a straightforward repair. A boiler with a restricted heat exchanger, recurring lockouts and corrosion is a different decision.
- Lean toward repair when the boiler has a good service history, the heat exchanger is in good condition, the fault traces to the sensor, a connector or a harness, and parts are readily available.
- Ask for a replacement estimate when E21 is one of several recurring faults, the heat exchanger shows corrosion or restriction, parts for an older control platform are hard to get, or the boiler has needed major repairs repeatedly.
- Look at the whole system: sizing, venting condition, condensate handling, circulators and the quality of the system water all matter as much as the code on the screen.
- Get it in writing: whichever way you go, you should see the reasoning, the work proposed and what the job includes before you decide.
Lochinvar boiler E21 service in Vancouver, Burnaby, Surrey and across Greater Vancouver
We are based in Burnaby and have worked on boilers across Metro Vancouver since 1999. We cover Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities including Port Coquitlam and Port Moody, the North Shore including North Vancouver and West Vancouver, New Westminster, Delta and Langley.
Housing stock shapes how an E21 call goes. In Vancouver and New Westminster, many older homes were converted from older hydronic or gravity systems, and a modern condensing boiler may have been tied into original piping and radiators, which raises the sludge and corrosion question. In Burnaby, Coquitlam and the Tri-Cities we often work in basement mechanical rooms and in townhouse and strata units where the boiler sits in a tight closet, so access and moisture from nearby plumbing are worth checking. On the North Shore, larger homes with multiple zones and in-floor heating are common, and the wet, shaded lots mean outdoor vent terminals can collect leaves and debris. Richmond and Delta homes often have mechanical equipment in garages, where rodents and damp air can affect wiring. In Surrey and Langley, newer subdivisions frequently have in-floor heating with boilers in garages or utility rooms. These are general patterns, not rules, and every house is assessed on its own.
In strata buildings, check your bylaws and let your property manager know before work, especially if venting runs through common property. For replacements we take out the gas permit with Technical Safety BC, and the work is inspected as required.
Boiler brands we service include Lochinvar, IBC, Navien, Rinnai, Bosch, Weil-McLain and Burnham. We are an independent contractor, not a dealer or warranty centre for any manufacturer, and we work on every brand neutrally.
Why Greater Vancouver homeowners call BC Wide for a Lochinvar E21 repair
BC Wide Home Services Ltd is a TSBC-licensed independent gas contractor, gas contractor licence LGA0090068 and Class B gas licence CGA0028029. Our work is done by our own licensed gas fitters, not passed to subcontractors. Gas work that needs a permit gets one, and it is inspected as Technical Safety BC requires.
You will always know where you stand. Diagnostic service calls are $189.00, and you get a written quote before any work beyond diagnosis. If the right answer is a new boiler, the in-home estimate for the replacement is free, and if you go ahead with the replacement or installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. If your boiler is still under manufacturer warranty, check your paperwork first: warranty claims go through the manufacturer’s own process, and we can tell you what we found so you can pursue it. Call (604) 473-9690 to book.
More questions homeowners ask
What does E21 mean on a Lochinvar boiler?
E21 on a Lochinvar boiler means the outlet (supply) water temperature sensor circuit is reading open or shorted. The control cannot trust the temperature of the water leaving the boiler, so it normally stops heating to protect itself. Confirm against the manual for your unit, and have a licensed technician test the sensor, wiring and connections.
Can I reset a Lochinvar boiler E21 code?
Only if your owner manual describes a reset, and only once. If E21 returns, stop resetting and call a licensed gas technician. A sensor circuit fault will keep coming back until the sensor, connector or wiring is fixed, and repeated resets can hide a separate safety problem.
Is it safe to run my Lochinvar boiler with an E21 error?
In most cases the boiler will not run properly with E21, because the control holds the burner off when it cannot read the supply temperature. Do not try to force it to fire by cycling power or bypassing anything. If you smell gas or a carbon monoxide alarm sounds, leave the home and call FortisBC or 911 from outside.
Why does my Lochinvar E21 code come and go?
An intermittent E21 usually points to a loose or corroded connector, a chafed wire, or moisture reaching the connections, rather than a completely dead sensor. Note when it appears and clears and whether there is any water near the boiler. A technician can then test the circuit while the fault is present and find the weak point.
How much does it cost to fix Lochinvar boiler error code E21?
Diagnostic service calls are $189.00, and after testing you get a written quote for the specific repair before any work starts. The total depends on whether the fault is the sensor, a connector, the wiring or the control board, which is why a proper diagnosis comes first. Call (604) 473-9690 to book.
Who fixes Lochinvar boiler E21 near me in Greater Vancouver?
BC Wide services Lochinvar boilers in Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are a TSBC-licensed independent contractor, licence LGA0090068, and we book same-day where we can. Call (604) 473-9690.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
- Lochinvar Boiler Code E23 — Inlet Sensor Short | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.