Lochinvar boiler error code E22 means Inlet Sensor Open: the control is reading the inlet (return) water temperature sensor circuit as open, so it cannot see the temperature of water coming back from your heating loop. Confirm the meaning against the manual for your unit. The cause is usually a failed sensor, a loose or corroded connector or damaged wiring, and occasionally the control board. It is not a homeowner repair: a licensed technician has to test the circuit with a meter to find which part has failed.
If your Lochinvar boiler is showing E22 (Inlet Sensor Open), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Needs attention.
What E22 means on a Lochinvar boiler
The inlet (return) water temperature sensor circuit is reading open.
Common causes
- Faulty inlet temperature sensor
- Disconnected or broken sensor wiring
- Control board fault
What you can safely check first
- No safe homeowner action — this is an internal sensor fault
- Call a technician to test and replace the inlet sensor
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing E22 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E00 — Invalid Lockout
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E06 — Auto Reset High Limit
Frequently asked questions
Is E22 on a Lochinvar boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after E22?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar boiler error code E22: what it means for your heat and hot water
In plain terms, E22 tells you the boiler has lost one of its eyes. A Lochinvar boiler relies on several temperature sensors to decide when to fire, how hard to fire and when to back off. The inlet sensor sits on the return side, where water comes back from your radiators, in-floor loops or fin-tube convectors. When that circuit reads open, the control is effectively reading nothing at all, so it cannot trust its own picture of what is happening inside the heat exchanger. Confirm the exact meaning, and how your boiler responds to it, against the manual for your unit, because control behaviour differs between model families and generations.
What you notice at home depends on how your system is piped. On a heating-only boiler, the usual result is a house that slowly cools while the thermostat keeps calling. If the boiler also heats an indirect hot water tank, your domestic hot water can fade as the tank cools down. Plenty of Metro Vancouver homes run both heat and hot water off one boiler, so a single sensor fault can take out both at once. These are the symptoms owners usually describe to us:
- The display shows E22 and the boiler will not fire, or it fires briefly and then stops.
- Radiators or heated floors are lukewarm or cold even though the thermostat is calling for heat.
- Hot water from an indirect tank runs out sooner than normal or never gets properly hot.
- The code clears after the power is switched off and on, then comes back within hours or days.
- The code appeared after recent work near the boiler, a leak, or a damp spell in the mechanical room.
- You can hear the circulator pump running, but the burner never lights.
Lochinvar boiler error code E22: likely causes and what we check first
Below are the causes we find behind an inlet sensor open message, with the most common first. The owner-safe column is short on purpose. This is an internal sensor circuit, and the guidance at the top of this page stands: there is no homeowner repair for it. The checks are about ruling out simple problems and giving the technician useful information, not about clearing the code.
E22 is a message about the sensor circuit, not a verdict on the sensor itself. The open reading can come from the sensor, the plug, the wire between them or the board that reads it. Replacing the sensor on a guess fixes some of these jobs and wastes a part on the rest, which is why we test the whole circuit from end to end.
- Power: confirm the boiler’s service switch is on and the breaker has not tripped. Do not open the boiler cabinet.
- Gas supply: confirm the manual shut-off valve on the gas line to the boiler is open, with the handle in line with the pipe. If you are not sure, leave it alone and tell us.
- Thermostat: make sure it is set to heat and above room temperature, and change the batteries if it uses them.
- One reset only, and only if the owner manual for your model describes a reset procedure. If E22 comes back, stop there.
- Outside intake and exhaust terminals: from outdoors, check they are clear of leaves, nests, snow or anything stacked against them. Do not remove or loosen terminal parts.
- Condensate drain: look at the visible drain line and any condensate pump for a kink, a loose hose or pooled water. Do not take the trap apart.
| Likely cause (most common first) | What is going on | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Loose or partly unseated sensor connector | Vibration, heating and cooling cycles or earlier service work can leave the plug sitting just off its contacts, which reads as an open circuit. | Nothing inside the cabinet. Note whether anyone has worked on the boiler recently and tell the technician. | Always. Reseating the plug means opening the boiler cabinet near live wiring and the gas train. |
| 2. Corroded or wet connector pins | A drip from a fitting, relief valve or condensate line onto the wiring harness can corrode the pins until they lose contact. | Without opening anything, look for water on the floor, drips under the boiler or a wet wall behind it. Take a photo. | As soon as moisture is involved, both the leak and the connector need a technician. |
| 3. Failed inlet temperature sensor | The sensing element inside the probe has broken internally, so it reads open whatever the water temperature is. | None. The sensor is on the water side of the boiler and can only be tested with a meter. | Always. Testing against the manufacturer’s resistance chart and replacing the sensor are technician work. |
| 4. Damaged wiring between sensor and control | Wire chafed on a sharp edge, damaged by heat, pinched by a panel or chewed by rodents in a garage or crawlspace. | From outside the cabinet, look for droppings or nesting material around the boiler. Do not touch any wiring. | Always. Wiring repair inside a gas appliance is licensed work. |
| 5. Control board input fault | Less common. The board’s input for that sensor fails, so a good sensor still reads open. | None. | Always. A board fault is only confirmed after the sensor and wiring have tested good. |
How our Lochinvar boiler repair visit works for an E22 code
Be realistic about what the owner checks above can do. A tripped breaker or a closed gas valve causes different behaviour, and a blocked vent or a backed-up condensate trap usually shows up as a different fault. They are worth checking because they are quick, safe and useful to the technician, not because they will clear an open sensor. Never jumper the sensor plug, bypass a safety or keep cycling the power to force the boiler to run. Repeated resets on an active fault hide what is actually wrong and can mask a second problem.
Diagnostic service calls are $189.00. That pays for a licensed gas fitter to come out, find the actual cause of the code and explain it to you before anything else happens. We book same-day where we can. In a cold snap the schedule fills quickly, so we will give you an honest earliest slot rather than promise an arrival window. Here is how the visit runs:
- Step 1, history first: we ask when E22 started, whether it clears on a reset, and what work, leaks or weather happened around that time. Intermittent faults usually have a story behind them.
- Step 2, read the control: we review the fault history and the live sensor readings on the boiler display, and compare the inlet reading with the other water sensors to see whether the open is constant or comes and goes.
- Step 3, isolate and test the sensor: with the power isolated, we unplug the sensor, measure its resistance with a digital multimeter and check the result against the manufacturer’s published temperature-to-resistance table for that sensor. An open reading, or one far off the chart, means the sensor has failed.
- Step 4, test the wiring: if the sensor tests good, we check the continuity of the wiring back to the control, flex-test it for an intermittent break and inspect the pins for corrosion or heat damage.
- Step 5, the control board comes last: a control board is one of the more expensive parts on a modulating condensing boiler, so we only call it after the sensor and wiring are proven good.
- Step 6, written quote before the work: if the fix goes beyond the diagnosis, you get a written quote listing the part, the labour and what it will solve before we start.
- Step 7, repair and test the safeties: after the repair we restore power and gas, run the boiler through a full heating cycle, confirm the sensor is reading believable temperatures, test the safeties (high limit, low-water protection where fitted, ignition and flame proving) and check combustion with an analyzer.
- Step 8, leave it documented: you get a written record of what we found, what we replaced and the readings we took once the repair was done.
Repair or replace an older Lochinvar boiler showing E22?
E22 on its own is rarely a reason to replace a boiler. A temperature sensor is one of the less expensive parts on the appliance, and the repair is usually simple once the cause has been proven. The parts most often involved are the inlet temperature sensor, its connector or a section of the wiring harness, and now and then the control board. We do not guess part numbers over the phone. The correct sensor is matched to the model and serial plate on your boiler. The decision changes when the code is just the latest in a run of problems on an older unit. These are the things that decide it on site:
If replacement makes sense, the in-home estimate for a new boiler is free and comes in writing. It covers sizing, venting, the permit and what happens to your existing piping. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. If a repair makes sense, we will say so plainly. We are an independent contractor, so we have no reason to push a particular brand or a replacement you do not need.
Whichever way you go, the water in the system matters. When we replace a boiler we flush the system, add a water treatment suited to the system, and fit a dirt and magnetite separator where the piping allows. A new boiler connected to a dirty old system simply inherits the sludge, along with the same risk of sensor and heat exchanger trouble.
- Heat exchanger condition: with Metro Vancouver’s soft water, the long-term problem is sludge and corrosion, not limescale. A heat exchanger clogged with magnetite sludge or showing corrosion is a bigger concern than any sensor.
- Repair history: several different faults over a few heating seasons usually means more are coming.
- Parts availability: some control and wiring parts for older generations become harder to source, so we check before we quote.
- Venting and condensate: an old vent that no longer meets current requirements, or a condensate setup that has been dripping onto the boiler, adds to the cost of keeping the old unit going.
- System fit: if the boiler was oversized, short-cycles constantly, or the house has been renovated since it went in, a correctly sized replacement may serve you better.
Lochinvar boiler error code E22 service across Greater Vancouver
We work on Lochinvar boilers in Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock varies a lot across that area, and it affects how an E22 call goes. These are general patterns we tend to see, not rules:
The climate across the region is mild and wet. That means long heating seasons run at low output rather than deep cold, a lot of on-off cycling, and many damp mechanical spaces. Mild weather is easy on a boiler’s burner, but it puts a great many heating and cooling cycles on sensors and connectors. That is one reason sensor-circuit faults show up on boilers that otherwise run well.
Boiler brands we service include Lochinvar, IBC, Viessmann, Weil-McLain, Navien, Rinnai, Bosch and Triangle Tube. We are an independent contractor that services these brands, not an authorised dealer or warranty centre for any of them. If your boiler may still be under the manufacturer’s warranty, check your paperwork first. We will document what we find so you have it for any claim.
- Vancouver and Burnaby: many older houses have been converted to condensing boilers, often in a tight basement or utility room shared with the water heater, where poor access and drips onto the wiring can both be factors.
- New Westminster and the North Shore: older homes on sloped lots often have boilers in damp lower levels, so moisture around connectors is one of the first things we look for. Homes higher up on the North Shore also get more snow drifting against side-wall vent terminals than most of the region.
- Surrey, Delta and Langley: many newer detached houses have radiant in-floor heating, and boilers in garages can be exposed to rodents and to cold air.
- Richmond: many townhouses and strata homes have compact mechanical closets, plus strata rules on access and venting that we work within.
- Coquitlam, Port Coquitlam and Port Moody: a mix of older split-levels and newer townhouse developments, with both basement and closet installations.
Why Greater Vancouver homeowners call BC Wide for Lochinvar boiler error codes
BC Wide Home Services Ltd has worked on heating systems in Metro Vancouver since 1999. We are an independent contractor licensed by Technical Safety BC under gas contractor licence LGA0090068, and our gas work is done by licensed gas fitters (Class B gas licence CGA0028029). We are not an authorised dealer or warranty centre for Lochinvar or any other manufacturer.
On a correct E22 job, you should get in writing how the fault was found and confirmed, which part was replaced, the readings taken after the repair, which safeties were tested, the combustion check result, and any other concerns we noticed such as sludge, a weeping fitting or a venting issue. To book, call (604) 473-9690.
Gas and carbon monoxide safety: a condensing boiler burns natural gas inside your home. If you smell gas (an odour like rotten eggs) or your carbon monoxide alarm sounds, do not attempt a reset or operate any switches. Leave the house, then call FortisBC or 911 from outside. Every home with a gas boiler should have working CO alarms near the sleeping areas.
- Licensed gas fitters on every gas job: our own technicians, not subcontractors.
- Permits and inspections taken out wherever the work requires them, for example a boiler replacement or changes to gas piping.
- A written quote before any work beyond the diagnosis, so the scope and the price are agreed first.
- Plain explanations: where we can, we show you the meter readings and the failed part.
- Honest timing: same-day where we can, and a straight answer when we cannot.
More questions homeowners ask
What does Lochinvar boiler error code E22 mean?
E22 means Inlet Sensor Open: the control is reading the inlet (return) water temperature sensor circuit as open. Confirm the meaning against the manual for your unit. The cause can be the sensor, its connector, the wiring or, less often, the control board, and only a meter test shows which one.
Can I reset a Lochinvar boiler with an E22 code?
Only once, and only if the owner manual for your model describes a reset. If E22 comes back, stop resetting, because an open sensor circuit will not fix itself and repeated resets can hide a second fault. Leave the boiler off and call a licensed technician.
Is it safe to run my Lochinvar boiler with error code E22?
Do not try to force it to run. The code is the control protecting the boiler because it cannot read the return water temperature, and the sensor must never be jumpered or bypassed. If you smell gas or a CO alarm sounds, leave the house and call FortisBC or 911 from outside.
Can I replace the inlet sensor on my Lochinvar boiler myself?
No. The sensor sits inside a gas appliance near the gas train and live wiring, and the job means testing against the manufacturer’s resistance chart and testing the safeties afterwards. In BC that is work for a licensed technician, and homeowners should stick to the outside-the-cabinet checks described above.
Why does E22 keep coming back on my Lochinvar boiler?
A code that comes and goes usually points to an intermittent connection, such as a corroded pin, a plug that is not fully seated, or a wire that breaks contact as it heats and cools. It is also common when a sensor has been replaced but the real fault was in the wiring. Testing the whole circuit end to end, including a flex test of the wiring, is how it gets fixed for good.
Do you repair Lochinvar boiler error code E22 near me in Greater Vancouver?
Yes. BC Wide services Lochinvar boilers in Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the Tri-Cities, the North Shore, New Westminster, Delta and Langley, booking same-day where we can. Call (604) 473-9690 and have the code and your boiler’s model plate details ready.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E23 — Inlet Sensor Short | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.