Lochinvar boiler error code E23 means the inlet (return) water temperature sensor circuit is reading shorted. The control can no longer trust the temperature of the water coming back from your heating loop, so it will normally stop the burner until the fault is cleared. Confirm the meaning against the manual for your unit. Owners can check power, look for water on or around the boiler and try one reset only if the manual allows it. Testing and replacing the sensor, wiring or control board is licensed work.
If your Lochinvar boiler is showing E23 (Inlet Sensor Short), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Needs attention.
What E23 means on a Lochinvar boiler
The inlet (return) water temperature sensor circuit is reading shorted.
Common causes
- Faulty inlet temperature sensor
- Pinched or damaged sensor wiring
- Control board fault
What you can safely check first
- No safe homeowner action — this is an internal sensor fault
- Call a technician to test and replace the inlet sensor
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing E23 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E00 — Invalid Lockout
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E06 — Auto Reset High Limit
Frequently asked questions
Is E23 on a Lochinvar boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after E23?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar boiler error code E23: what it means for your heat and hot water
In plain terms, your boiler has a small temperature sensor where water returns from your radiators, baseboard convectors or in-floor loops. The control compares that return reading with the outlet reading to decide how hard to fire, when to turn the flame down and whether water is moving through the heat exchanger properly. When the inlet circuit reads as shorted, the control is getting a reading it treats as impossible, so it cannot make those decisions safely. On most units the result is that the burner will not fire while the code is active. Confirm the exact behaviour against the manual for your unit.
Sensors of this kind are commonly thermistors. Their electrical resistance changes as the water temperature changes, and the control converts that resistance into a temperature. A short means the circuit is reading far less resistance than any real water temperature could produce. That can come from the sensor itself failing, from the two wires touching or grounding somewhere along their run, from moisture bridging the connector, or less often from the input on the control board. The code tells you which circuit is complaining, not which of those parts is at fault. That is why a proper fix starts with measurement rather than a parts swap.
What you notice at home depends on how your system is set up. These are the symptoms owners usually describe when they call us about this code:
- Radiators, baseboards or heated floors going cool even though the thermostat is calling for heat.
- The display showing E23, sometimes with the circulating pump running briefly and then stopping.
- No hot water at the taps if the boiler also heats an indirect tank or is a combi model, while a separate gas water heater in the house keeps working normally.
- The code clearing after a power cycle, then returning within hours or by the next morning.
- A boiler that seemed fine through the autumn showing the code on the first properly cold night, when it is asked to work hardest.
- Drips, staining or a damp patch near the boiler, which can be connected to the fault (see the likely causes below).
Lochinvar boiler error code E23: what we check first, most likely cause first
The list near the top of this page names the usual suspects. Here is the order we actually work through them on site, what an owner can safely look at for each one, and the point where it becomes a licensed call. The order reflects what we generally find in the field, not a fixed rule. Every boiler gets measured before anything is replaced.
Metro Vancouver water is soft, so hydronic systems here tend to suffer from sludge and corrosion rather than hard limescale. That matters for this code mainly through leaks: corrosion at an old fitting, a weeping valve or a pump flange is a common source of the slow drip that eventually finds its way to a sensor connector.
- 1. Failed inlet temperature sensor. The most common finding. The sensing element breaks down with age and thousands of heat cycles, or moisture gets inside it. Owner check: none beyond noting whether the code is constant or comes and goes. Licensed call: always, because testing means isolating the circuit and comparing readings with a meter, and replacement usually means valving off or partially draining the boiler.
- 2. Damaged, pinched or chafed sensor wiring. Wires that rub against sheet metal, rest against a hot pipe or were pinched when a cover was refitted can wear through and short together or to ground. Owner check: without removing any panel, look for anything obviously crushed, melted or hanging loose where wiring is visible from outside. Licensed call: any wiring repair or rerouting inside the cabinet.
- 3. Water at the sensor connector. A weeping fitting, a slow leak at a pump flange or a leaking condensate line can drip onto the connector and bridge the terminals. Owner check: look for drips, crusty residue or rust staining on and under the boiler and along the condensate line. Licensed call: tracing and fixing the leak, then drying or replacing the connector and sensor.
- 4. Control board input fault. Less common, and only concluded after the sensor and wiring both test good. Owner check: none. Licensed call: always. A control board is one of the more expensive parts on a boiler, so it should never be the first guess.
- 5. Fault that started after other work. Sometimes the code appears soon after a pump change, new piping or other work near the boiler, because a connector or wire was disturbed. Owner check: tell the technician what was done and when. Licensed call: yes, to inspect connectors and wire routing.
| Likely cause | What it looks like to you | What you may safely do | When it becomes a licensed call |
|---|---|---|---|
| Failed inlet sensor | Code returns quickly after any reset; no visible damage | Note when the code appears and whether it is constant | Straight away; testing and replacement need meters and a partial drain-down |
| Damaged or pinched wiring | Code comes and goes, sometimes when the pump starts or the cabinet vibrates | Look at visible wiring without opening any panel | Any repair or rerouting inside the cabinet |
| Water on the connector | Drips, staining or residue on or below the boiler | Keep the area dry, place a tray, photograph where water appears | Finding the leak source and drying or replacing parts |
| Control board input | Sensor and wiring test good but the code persists | Nothing; do not keep resetting | Always; board diagnosis and replacement |
| Disturbed after other work | Code started soon after a pump, piping or other job | Tell the technician what was done and when | Inspection of connectors and wire routing |
Can I reset a Lochinvar boiler showing E23, and what can I safely check?
There is a short list of checks you can do yourself. None of them involve opening the boiler cabinet, and none of them will repair a failed sensor, but they rule out the simple things and give the technician useful information before they arrive.
What you should not do: open the front cover or control compartment, unplug or replug sensor connectors, jumper or bypass anything, swap sensors between positions, or keep cycling power to squeeze a few more hours of heat out of the boiler. Gas appliance work in BC is legally restricted to licensed gas fitters, and electrical work inside the appliance belongs with a qualified technician. A boiler forced to run without a valid return-water reading has lost one of the inputs it uses to protect its own heat exchanger.
Gas and carbon monoxide safety: E23 is not a gas leak or a combustion fault in itself, but any gas boiler deserves the same caution. If you smell gas (a rotten-egg or sulphur odour) or your carbon monoxide alarm sounds, do not touch light switches or the boiler, get everyone out of the house, and call FortisBC or 911 from outside. Every home with a gas appliance should have a working CO alarm near the sleeping areas, so test yours while you are thinking about it.
- Power: confirm the boiler’s service switch is on and its breaker has not tripped. If the breaker trips again after you reset it, leave it off and call.
- Gas supply: confirm the manual gas valve on the line to the boiler is in the open position. E23 is a sensor fault rather than a gas fault, but a closed valve is worth ruling out.
- Thermostat: confirm it is calling for heat, set above the current room temperature, with working batteries if it uses them.
- One reset, only if your owner manual allows it: follow the manual’s reset procedure once. If E23 returns, stop there. Repeated resets do not fix a sensor and can hide a developing problem.
- Venting terminals outside: check that the intake and exhaust terminals are clear of leaves, snow, nests or anything stacked against them. This does not cause E23, but a blocked terminal on top of a sensor fault makes diagnosis harder.
- Condensate drain: where the drain line is visible, check that it is not kinked, disconnected or overflowing, and that no water is pooling near the boiler.
- Water on or near the boiler: look for drips, damp, rust staining or crusty residue on the casing, the floor and the nearby piping. Take photos to show the technician.
- Pressure gauge: note the reading on the boiler’s pressure gauge and pass it on. Do not add water or open any valve to change it unless your manual specifically tells owners to.
How our Lochinvar boiler E23 repair visit works, step by step
Diagnostic service calls are $189.00. That covers a licensed technician attending, finding the actual cause of the code and explaining it to you before any repair work is done.
What a correct job looks like when we leave: a boiler running through a full heating cycle with no fault code on the display, correct and sensible inlet and outlet readings, no water at any joint, wiring neatly secured away from heat, and an invoice that names both the part replaced and the cause found. If anyone proposes replacing the control board first without measuring the sensor and wiring, it is fair to ask why.
- Step 1, booking: when you call (604) 473-9690 we ask what the display shows, whether the code is constant or intermittent, whether you have heat and hot water, and whether there is any water near the boiler. We book same-day where we can. In a cold snap that is not always possible, and we will tell you honestly what timing is realistic rather than promise an arrival window.
- Step 2, first look: the technician confirms the code on the display, checks any stored fault history the control keeps, and looks over the boiler, venting, condensate line and nearby piping for leaks or signs of past work.
- Step 3, measurement: the inlet sensor circuit is isolated and measured with a meter, and the reading is compared with the manufacturer-published values for the actual water temperature at the time. The wiring is checked for continuity and for shorts between conductors and to ground, along its full run wherever it can be reached.
- Step 4, finding the true cause: from those results the fault is pinned on the sensor, the wiring, the connector or, only once everything else tests good, the control board input. If water is involved, the leak source is traced first so it does not ruin the replacement part.
- Step 5, written quote: before any work beyond the diagnosis, you receive a written quote describing the repair. In general terms the parts most often involved are a replacement inlet sensor, a wiring section or connector, the sealing or replacement of a leaking fitting, or in rarer cases a control board. Nothing proceeds until you approve it.
- Step 6, the repair: power is isolated, the boiler is valved off or partially drained as needed, the correct component for your boiler is fitted, and wiring is rerouted away from hot surfaces and sharp edges and properly secured.
- Step 7, refill and test: the system is refilled and purged of air, pressure is restored, and the boiler is run through a full heating cycle. We confirm the inlet and outlet readings agree with each other, check that the safety and limit controls operate, leak-test any gas joint that was disturbed, and confirm combustion and venting are normal.
- Step 8, the paperwork: you get a written record of what was found, what was replaced and anything we recommend watching, so the next technician, your strata or a future buyer can see the history of the boiler.
Should I repair or replace an older Lochinvar boiler with an E23 fault?
In most cases an E23 repair is a sensor, wiring or connector job, and on a boiler in otherwise good condition that is clearly worth doing. One failed sensor is not a reason to replace a boiler. The question only becomes real when the E23 visit uncovers bigger problems, or when the boiler is already near the end of its service life and the owner wants an honest view before spending on it again.
Repair is usually the right call when the boiler is in good overall condition, the heat exchanger is clean and dry, the fault traces cleanly to a sensor, wire or connector, and the system has been reliable until now. Replacement deserves a conversation when you see the signs below:
- The heat exchanger shows corrosion, leaks or heavy sludge build-up that cleaning cannot reasonably fix.
- The fault is in the control board on an older unit, and replacement parts are hard to source or slow to arrive.
- The boiler has a history of repeated lockouts and repair visits over recent heating seasons.
- Your heating needs have changed: a renovation, an addition, a secondary suite, or a change in how you want domestic hot water supplied.
- The venting or condensate arrangement no longer meets current requirements and would need rework in any case.
- If replacement is on the table, the in-home estimate for replacing or installing equipment is free. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.
- A replacement boiler in BC needs a gas permit and an inspection. We size from the house and its heating loops rather than copying the old boiler’s label, and we look at venting, condensate disposal, the condition of the system water, and whether the existing loops need flushing or a dirt separator to protect the new heat exchanger. All of it goes into a written quote before you decide.
Lochinvar boiler service near me: Greater Vancouver coverage, brands and who does the work
BC Wide services hydronic boilers across Greater Vancouver from our base in Burnaby: Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities (Port Coquitlam and Port Moody), the North Shore (North Vancouver and West Vancouver), New Westminster, Delta and Langley.
Housing stock shapes how these jobs go. Older homes in Vancouver, Burnaby and New Westminster often have hydronic systems that have been converted or extended over the decades, sometimes with a modern high-efficiency boiler connected to older radiator loops, which is exactly where sludge and corrosion at fittings tend to show up. On the North Shore, hillside homes commonly have in-floor radiant loops and boilers tucked into tight mechanical rooms. In Surrey, Langley, Richmond, Delta and the Tri-Cities, many newer houses and townhouses use combi boilers or a boiler with an indirect tank in a compact closet, where wiring runs close to piping and service access is limited. In strata buildings the boiler may sit in a tight or shared space and the vent terminal location can be governed by strata rules, so we coordinate access with the owner and, where needed, the strata manager.
Our mild, wet coastal winters mean many boilers run long, gentle cycles for months at a time rather than short hard bursts. That steady duty, combined with damp basements, crawlspaces and garages, is part of why moisture at connectors and slow corrosion at fittings are such common findings on Metro Vancouver boilers.
Brands we service include Lochinvar, Navien, Viessmann, IBC, Buderus, Weil-McLain, Rinnai and Bosch, along with other common residential boiler brands. We are an independent contractor, so we work on the boiler you already have rather than steering you towards one manufacturer.
Who does the work: BC Wide Home Services Ltd is an independent, Technical Safety BC licensed gas contractor (licence LGA0090068, Class B gas licence CGA0028029), serving Metro Vancouver since 1999. Repairs are carried out by our own licensed gas fitters. We are not an authorised dealer or warranty centre for any boiler brand. If your boiler is still within the manufacturer’s warranty period, check your warranty terms before booking any repair; we can document what we found so you can take it up with the manufacturer. Permits are pulled where the work requires one, inspections are arranged, and you receive a written quote before any work beyond diagnosis. To book, call (604) 473-9690.
More questions homeowners ask
What does E23 mean on a Lochinvar boiler?
E23 means the inlet (return) water temperature sensor circuit is reading shorted; confirm the meaning against the manual for your unit. The control can no longer trust the temperature of the water coming back from your heating loop, so it normally stops the burner. The cause is usually the sensor itself, its wiring or moisture at the connector, and less often the control board.
Can I reset a Lochinvar boiler with error code E23?
You can try one reset if your owner manual allows it, following the manual’s procedure exactly. If E23 comes back, stop and call a licensed technician. A reset cannot repair a shorted sensor circuit, and repeated resets can hide a problem that needs attention.
Is it safe to run my Lochinvar boiler with an E23 code?
On most units the boiler will not fire while E23 is active, so in practice it is not running, and you should never try to force it by jumpering or bypassing the sensor. The code itself is the control protecting the boiler from running on a bad reading. If you smell gas or your CO alarm sounds, leave the house and call FortisBC or 911 from outside.
How long does a Lochinvar E23 repair take?
Once the cause is found and the correct part is on hand, a sensor or wiring repair is usually finished in a single visit, including refilling, purging air and test-firing the boiler. A control board fault, or a leak that needs piping repair first, can take longer, particularly if parts must be ordered. We tell you on the visit what timing is realistic.
Will error code E23 come back after the sensor is replaced?
If the sensor really was the cause, a correct replacement normally ends the code. E23 tends to return when the underlying cause was missed, such as chafed wiring, a slow leak dripping onto the connector, or a control board input fault. That is why we measure the wiring and look for water before replacing anything, and why your invoice should name the cause found.
Who repairs Lochinvar boilers near me in Greater Vancouver?
BC Wide repairs Lochinvar and other boiler brands in Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed gas contractor, not a dealer or warranty centre, and the work is done by our own licensed gas fitters. Call (604) 473-9690; we book same-day where we can.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.