Lochinvar boiler error code n05 (Fan Increased — Low Flame Current) is a status notification, not a lockout: the boiler control has raised fan speed because the flame current it measures is too low. Confirm against the manual for your unit. The boiler usually keeps giving heat and hot water, but the cause, most often a fouled flame sensor or combustion drift, should be checked by a licensed gas technician soon. If you smell gas or a CO alarm sounds, leave and call FortisBC or 911 from outside.
If your Lochinvar boiler is showing n05 (Fan Increased — Low Flame Current), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Status / informational.
What n05 means on a Lochinvar boiler
Notification (still running): the control has increased fan speed because the measured flame current is low.
Common causes
- Dirty flame sensor
- Combustion/gas pressure drift
- Early ignition-component wear
What you can safely check first
- No homeowner action — this is a combustion-related notification
- Have a technician check the flame sensor and combustion at the next service
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing n05 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E00 — Invalid Lockout
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E06 — Auto Reset High Limit
Frequently asked questions
Is n05 on a Lochinvar boiler serious?
It’s typically a status/informational code rather than a breakdown, but confirm against the symptoms. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after n05?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar boiler error code n05: what it means for your heat, hot water and safety
In plain terms, n05 is the boiler telling you it noticed something and adjusted itself. A modern Lochinvar condensing boiler proves its flame electronically: a sensor sitting in the flame carries a very small electrical current, and the control reads that current as proof that the burner is lit and burning properly. When the reading sags, the control responds by increasing fan speed, which changes the air and gas mix at the burner, to try to bring the signal back up. The display shows n05 so that you, and whoever services the boiler, know it had to do that. Confirm the exact wording and behaviour against the manual for your unit, because control software and display text vary between generations.
For your house, n05 usually means nothing obvious yet. The radiators or in-floor loops still warm up, and if the boiler also heats your domestic hot water through an indirect tank, the showers still run hot. The reason it matters is what n05 tends to come before. A flame signal that is drifting low is a signal getting closer to the point where the control can no longer prove flame at all, and at that point the boiler stops trying and locks out. On the coldest, wettest week of the winter, that is the difference between a planned service visit and a cold house waiting for a technician.
On the safety side, n05 is not a carbon monoxide alarm and it is not a gas leak warning. But a low flame signal often goes hand in hand with combustion that has wandered out of adjustment, and combustion that is out of adjustment is exactly what a technician measures with an analyser before deciding an appliance is fit to keep running. Treat the code as a reason to book a visit soon: not a reason to panic, and not a reason to ignore it.
What owners usually describe when they call us about Lochinvar error code n05:
- The display shows n05 now and then, then clears on its own
- The boiler sounds louder than usual, with a higher-pitched fan or a rushing sound at the burner
- The house still heats, but takes longer to come up to temperature on cold mornings
- The code shows up mostly at start-up or just after the burner lights
- The boiler sometimes tries to light more than once, or restarts partway through a heat call
- The code first appeared after heavy rain, a wind storm, leaf fall or snow that covered the outdoor vents
- The boiler has not had a full combustion service in a while
Lochinvar boiler error code n05: what we check first
These are the likely causes in the order we most often find them, most common first. The first three are the causes listed in the guide above; the rest are site conditions that commonly drag a flame signal down on a sealed-combustion condensing boiler. Each one is a starting point for diagnosis, not a conclusion. A low flame signal is a symptom, and the job on site is to prove which of these is producing it on your boiler before anything is replaced.
1. A dirty or worn flame sensor. Combustion slowly leaves a film on the sensor rod, and the ceramic insulator can crack or the rod can erode over many heating seasons. Either one weakens the current the control reads. Sometimes a careful cleaning restores a healthy reading; often, on an older sensor, replacement is the right call. Either way it happens inside the sealed combustion chamber, so it is technician work.
2. Combustion or gas pressure drift. A condensing boiler is set up to burn a precise mix of gas and air. If inlet gas pressure is marginal, for example on a cold morning when every gas appliance in the house is firing, or if the burner and its seals have aged, the mix moves and the flame signal follows. Only a manometer and a combustion analyser tell you which.
3. Early wear in ignition components. The igniter, its cable, its gasket and the ground path all affect how cleanly the burner lights and how stable the flame is in the first seconds. Wear here often shows up as n05 at start-up before it ever becomes a failed ignition.
4. Restricted intake or exhaust venting. In our climate this is a real one: leaves, moss, wasp and bird nests, snow banked against a sidewall terminal, or plastic left over a vent after exterior painting. A restricted pipe changes how much air reaches the burner.
5. Condensate not draining freely. A condensing boiler makes acidic water that must leave through a trap, a neutraliser and a drain. If that path backs up, it can interfere with combustion inside the heat exchanger.
6. Loose or corroded wiring or grounding in the flame-sensing circuit. Damp mechanical rooms and crawlspaces are common in Metro Vancouver, and a poor connection gives a weak, unsteady reading that looks random.
| Likely cause | What you might notice | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Dirty or worn flame sensor | Code comes and goes, often at start-up | None inside the boiler; note when and how often the code appears | Always: the sensor is inside the sealed combustion chamber |
| 2. Combustion or gas pressure drift | Louder fan, rougher light-off, code becoming more frequent | Confirm the gas valve to the boiler is fully open and other gas appliances run normally | Always: gas pressure and combustion adjustment are licensed gas work |
| 3. Early ignition-component wear | Several tries to light, occasional restarts | Confirm steady power and that the service switch is on | Always: igniter, cable and ground checks need meters and panel access |
| 4. Restricted intake or exhaust venting | Code after storms, snow, leaf fall or new nests | Look at the outdoor terminals from the ground; remove loose debris by hand only if safely reachable | If anything is lodged inside a pipe, a pipe is damaged, or the code persists |
| 5. Condensate not draining freely | Gurgling, water near the boiler, code during long run times | Look at the visible drain tubing and neutraliser for kinks, disconnection or overflow | If the trap or internal drain is blocked or water is inside the cabinet |
| 6. Loose or corroded sensor wiring or ground | Code appears at random, unrelated to weather | None; do not touch control wiring | Always: electrical diagnosis inside the appliance is technician work |
Can I fix Lochinvar error code n05 myself? Safe checks and where to stop
Some checks are yours and some are legally and practically ours. In BC, work on gas appliances, gas piping and venting, and most electrical work inside the appliance, is restricted to licensed trades. These are the checks a homeowner can safely make on a Lochinvar boiler showing n05, without opening anything. They are listed below.
What not to do: never open the burner compartment or remove the sealed front panel, loosen gas fittings, adjust the gas valve, jumper or bypass a sensor or switch, or keep power-cycling the boiler to make the code go away. Repeated resets do not fix a low flame signal. They hide the pattern a technician needs to see, and a boiler that keeps relighting with poor combustion is not one you want running unattended.
It becomes a licensed call when the code returns after one permitted reset, when the boiler moves from notifications into a lockout, when you hear unusual burner noise or see a flame through the sight glass that looks different from normal, when water appears inside or under the cabinet, or when any part of the venting looks cracked, disconnected or sagging. At that point the diagnosis needs meters, a combustion analyser and access inside the appliance, and that work belongs to a licensed gas technician.
Gas and carbon monoxide safety: if you smell gas, the rotten-egg odour added to natural gas, or a CO alarm sounds, do not touch light switches, the thermostat or the boiler. Get everyone out of the home, then call FortisBC or 911 from outside. Every home with a gas boiler should have working CO alarms near sleeping areas and on each level, tested regularly. A code on a boiler display is never a substitute for a CO alarm.
- Power: confirm the service switch near the boiler is on and the breaker has not tripped. Do not open the boiler cabinet to look further.
- Gas supply: confirm the manual gas valve on the pipe feeding the boiler is open, with the handle running in line with the pipe. If it was closed and you do not know why, leave it closed and call us.
- Thermostat: confirm it is calling for heat, is set above room temperature, and does not have low batteries.
- Reset: only if the owner manual for your unit allows it, and only once. If the code returns, stop resetting and book a visit.
- Outdoor terminals: look at the intake and exhaust terminals from a safe spot for snow, leaves, nests or plastic sheeting. Remove loose debris by hand only if you can reach it from the ground, never from a ladder on a wet roof.
- Condensate: look at the visible drain tubing and neutraliser for kinks, disconnection or water pooling under the boiler.
How our Lochinvar n05 repair visit works, step by step
Diagnostic service calls are $189.00. This is what that visit looks like when a BC Wide technician arrives for a Lochinvar boiler showing n05, from the phone call to the boiler running through a full heat call again.
The parts most often involved, in general terms, are the flame sensor, the igniter with its cable and gasket, the burner and its seals, and less often the gas valve, the blower or the control board when they measure out of specification. A flame sensor is one of the less expensive parts on a modern condensing boiler; a control board, gas valve or blower sits at the more expensive end. We tell you which it is, and why, in writing before you decide anything.
Who does the work matters on a gas appliance. BC Wide Home Services Ltd is an independent, Technical Safety BC licensed gas contractor (gas contractor licence LGA0090068, Class B gas licence CGA0028029), serving Metro Vancouver since 1999. Our own licensed gas fitters diagnose and repair the boiler. We service Lochinvar boilers as an independent contractor, not as an authorized dealer or warranty centre, so if your boiler may still be under manufacturer warranty, keep the purchase and installation paperwork handy and we will explain what a warranty claim involves. Where a repair requires a gas permit and inspection, for example replacing venting, we take out the permit and arrange the inspection.
- Step 1, booking: we ask what the display shows, how often n05 appears, when the boiler was last serviced, and whether anything changed recently, such as a renovation, a new gas appliance or a storm. We book same-day where we can, depending on the schedule and your location; we do not promise a fixed arrival window.
- Step 2, history before parts: we read the control’s stored history and operating data, so we can see how often the boiler has had to compensate, not just whether it is doing so at that moment.
- Step 3, flame signal measured, not guessed: we put a meter on the flame-sensing circuit and compare the live reading against the manufacturer-published specification for your model.
- Step 4, gas supply and combustion: we check inlet gas pressure with a manometer while the boiler and other gas appliances run, then test combustion with a calibrated analyser at low and high fire to see whether the burner mix is where the manufacturer’s documentation says it should be.
- Step 5, inspection with the boiler isolated: gas and power off, we inspect the flame sensor, igniter, wiring, grounds, burner and combustion chamber for fouling, cracking or corrosion, and follow the venting and condensate path end to end.
- Step 6, written findings and quote: you get the cause in plain language and a written quote before any work beyond diagnosis. Nothing proceeds until you approve it.
- Step 7, repair and safety testing: after the repair we re-measure the flame signal and combustion, test the safeties including flame proving, venting and condensate protection, confirm n05 no longer appears, and watch the boiler through a complete heat call before we leave.
Repair or replace an older Lochinvar boiler that shows n05?
Most of the time, n05 on its own points to a repair, and often a routine one: a flame sensor cleaned or replaced, combustion set back to specification, ignition parts renewed. The code does not mean the boiler is finished. Replacement only becomes a real conversation when n05 is one symptom among several on an older boiler, and when the cost of keeping it going starts to outweigh what it still has to give.
The deciding factors are the condition of the heat exchanger, how many major parts are failing at once, whether parts are still easy to get, and whether the boiler suits the house. In Metro Vancouver the water is soft, so problems on the hydronic side are sludge and corrosion rather than limescale. Dark, sludgy system water restricts the heat exchanger and makes a boiler work harder and run longer, which wears ignition parts and flame sensors faster. We look at the system water as well as the burner, because fixing n05 on a boiler whose heat exchanger is clogged only buys time.
Signs it is worth a replacement conversation rather than another repair:
If you are weighing it up, our in-home estimate for replacing or installing equipment is free and comes with a written quote. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. We will give you a straight answer on whether a repair makes sense; we would rather fix a sound boiler than replace it early.
- The heat exchanger shows corrosion, or is restricted by sludge that flushing will not clear
- Several major components are failing or measuring out of specification at the same time
- Parts for your boiler are hard to source or have long lead times
- The boiler is badly oversized for the house and short-cycles, wearing out ignition parts quickly
- You are renovating, adding a heating zone, or changing how the house makes domestic hot water
Lochinvar boiler error code n05 service near me in Greater Vancouver
We diagnose and repair Lochinvar boilers across Greater Vancouver: Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. The causes of n05 do not change from one city to the next, but the conditions around the boiler do, and that shapes what we look at first.
Across the whole region, our mild, wet coastal climate means boilers run long, steady heating seasons rather than short extreme ones. That is fairly easy on a heat exchanger, but it is steady wear on igniters and flame sensors, and the rain, moss and leaf fall are hard on outdoor vent terminals and condensate drains. Older housing stock and dense strata buildings add their own venting and access challenges.
Besides Lochinvar, we service boilers from Viessmann, IBC, Navien, Weil-McLain, Triangle Tube, Buderus, Bosch and Rinnai, as an independent contractor rather than a dealer for any of them.
Call (604) 473-9690 to book. Tell us the code on the display and how often you see it, and we will book the earliest visit we can, same-day where we can.
- Vancouver and Burnaby: many older houses have moved to condensing boilers over the years, sometimes reusing older piping and radiators. Older system water and mixed piping are where sludge tends to come from, and vent runs in older homes can be long or awkward.
- New Westminster, Coquitlam and the Tri-Cities: plenty of townhouses and strata buildings with boilers in tight mechanical closets and sidewall vent terminals near balconies, walkways or neighbouring units, where clearances and blockages matter.
- The North Shore: wetter than much of the region, and higher elevations tend to see more snow, so buried or iced terminals are a more common trigger after a cold snap.
- Richmond and Delta: low, flat and often windy, so wind-driven rain and debris around ground-level terminals are worth checking.
- Surrey and Langley: many newer and larger homes with in-floor radiant heating and multiple zones, where long run times put steady demand on the burner and ignition parts.
More questions homeowners ask
What does Lochinvar boiler error code n05 mean?
n05 means Fan Increased — Low Flame Current: the control has raised fan speed because the flame current it measures is low. It is a status notification, and the boiler normally keeps running while it shows. Confirm against the manual for your unit, and book a flame-sensor and combustion check soon so it does not progress to a lockout.
Can I reset a Lochinvar boiler showing n05?
Only if the owner manual for your unit allows it, and only once. Because n05 is a notification rather than a lockout, a reset is often not needed and will not fix a low flame signal. If the code comes back, stop resetting and have a licensed gas technician measure the flame signal and combustion.
Is it safe to run my Lochinvar boiler with an n05 code?
The boiler is designed to keep running while it shows n05, which is why it is a notification rather than a fault lockout. Keep your CO alarms working and book a check soon, because a low flame signal often comes with combustion drift. If you smell gas or a CO alarm sounds, leave the home and call FortisBC or 911 from outside.
Why does my Lochinvar boiler keep showing n05?
A code that keeps coming back means the cause is still there, and most often that is a fouled or worn flame sensor or combustion that has drifted out of adjustment. Worn ignition parts, a restricted vent terminal, a backed-up condensate drain or a poor connection in the sensing circuit can do it too. A technician with a meter and a combustion analyser can tell you which one it is.
How much does it cost to fix Lochinvar error n05?
It depends entirely on the cause, which is why we diagnose before we quote. Cleaning or replacing a flame sensor is usually at the modest end of boiler repairs, while a gas valve, blower or control board sits at the expensive end. You receive a written quote before any work beyond diagnosis.
Who repairs Lochinvar boilers near me in Greater Vancouver?
BC Wide Home Services Ltd is an independent, Technical Safety BC licensed gas contractor serving Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley since 1999. Our own licensed gas fitters diagnose and repair Lochinvar boilers. Call (604) 473-9690 and we will book the earliest visit we can, same-day where we can.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.