Lochinvar boiler error code n06 is a notification that the domestic-hot-water (DHW) sensor on a combi model has a fault, so the boiler cannot properly read or control the temperature of your tap hot water (confirm against the manual for your unit). Space heating may keep working, but hot water can run too cool, too hot or uneven. There is no safe homeowner fix because the sensor is internal: check power and the gas valve, reset once only if your manual allows it, then book a licensed technician.
If your Lochinvar boiler is showing n06 (DHW Sensor Fault (Combi Only)), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.
Severity: Needs attention.
What n06 means on a Lochinvar boiler
Notification: the domestic-hot-water sensor on a combi model has a fault, which can affect hot-water temperature control.
Common causes
- Faulty DHW temperature sensor
- Loose or damaged sensor wiring
What you can safely check first
- No safe homeowner action — the DHW sensor is internal
- Have a technician test and replace the DHW sensor
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Lochinvar boiler repair across Greater Vancouver
If a Lochinvar boiler showing n06 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Lochinvar boiler codes
- Lochinvar boiler E00 — Invalid Lockout
- Lochinvar boiler E01 — Memory Lockout
- Lochinvar boiler E02 — Fan Speed Fault
- Lochinvar boiler E04 — Flow Switch Fault
- Lochinvar boiler E05 — Flame Out of Sequence
- Lochinvar boiler E06 — Auto Reset High Limit
Frequently asked questions
Is n06 on a Lochinvar boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.
How do I reset a Lochinvar boiler after n06?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Lochinvar boiler error code n06: what it means for your heat and hot water
In plain terms, n06 tells you the boiler has stopped trusting one of its own thermometers. A combi boiler heats your home and your tap water from one burner. To make hot water, the control needs to know how warm the water leaving the domestic side actually is, and it gets that reading from the DHW sensor. When the reading is missing, out of range or does not make sense, the control flags n06. The guide above lists the severity as needs attention: it is not the same as a flame or venting lockout, but it is a real fault that will not stay cleared for long on its own.
What the boiler does next depends on the model and its software, so confirm against the manual for your unit. In the homes we visit, owners usually describe the symptoms rather than the code, which is why we list them here in owner words. If any of these match what you are seeing alongside n06 on the display, the sensor circuit is the first place a technician will look.
- Hot water at the taps is lukewarm even though the radiators or in-floor heat feel normal.
- Shower temperature surges hot then cool, or swings while nobody touches the handle.
- Hot water is noticeably hotter than usual, which is a scald risk for children and older family members.
- The boiler fires for hot water, stops, then fires again in short bursts.
- The n06 notification comes and goes, often after the boiler has been making hot water for a while.
- Space heating seems fine, but hot water has been unreliable for days or weeks before the code appeared.
Why does one hot-water sensor cause so much trouble on a combi boiler?
The DHW sensor is a small temperature probe whose electrical resistance changes as the water temperature changes. The control converts that resistance into a temperature and uses it to set the burner firing rate and to manage how heat is sent to the domestic side instead of the heating loop. If the probe reads wrong, the control is effectively driving blind. That is why a fault that sounds minor can produce hot water that is both inconsistent and, in some cases, hotter than you set it. If you notice scalding temperatures at a tap, stop using hot water and call a technician rather than waiting.
The causes below are listed in the order we usually find them on site with combi boilers. The existing page names the two headline causes; this list adds what sits behind them, and for each one the check an owner can safely make and the point where it becomes work for a licensed technician.
1. The DHW sensor itself has failed. Temperature probes age. Years of heating and cooling cycles can break down the element inside, and a probe that drifts slowly can produce intermittent n06 notifications long before it fails outright. The only way to confirm it is to measure the sensor against the manufacturer’s resistance-and-temperature chart, which means opening the cabinet. That is licensed work.
2. A loose, corroded or damaged connector or wire. The sensor connects to the control through a small plug and a short wiring run. Vibration, heat and the occasional bump during other work can loosen the plug or chafe the insulation. Corrosion on the pins shows up more often than people expect in damp basements, garages and crawlspace utility rooms. A technician checks continuity end to end and reseats or repairs the connection.
3. The sensor has lost good contact with the pipe or fitting it reads. If a clip-on probe has slipped or its mounting has loosened, it reads the air around it rather than the water, and the control sees numbers that do not match what the burner is doing. It is a quick repair once found, but finding it needs the cover off.
4. Moisture reaching the sensor connection. A slow weep from a fitting on the domestic or heating side inside the cabinet can drip onto the sensor plug. If you can see water on the floor under the boiler or staining on the cabinet, mention it when you call; the weep needs fixing as well as the sensor.
5. A control board input problem. This is the least common cause, but it is real: if the sensor and wiring test good, the board’s input for that sensor may be at fault. A control board is one of the more expensive parts on a boiler, so a careful technician proves the simpler parts are good before recommending one.
| Likely cause | What you may notice | Owner-safe check | Licensed work |
|---|---|---|---|
| Failed DHW sensor | Lukewarm or swinging hot water, n06 returns after a reset | Note when the code appears and what the hot water was doing | Resistance test against the manufacturer chart, sensor replacement |
| Loose or damaged wiring or connector | Code comes and goes, sometimes after the unit is bumped or after other work nearby | None inside the cabinet; do not open the cover | Continuity test, reseat or repair the harness |
| Sensor slipped off its mounting | Readings that do not track the burner, erratic hot water | None inside the cabinet | Remount the probe and confirm readings at a measured temperature |
| Moisture on the connection | Water under the boiler, staining, code after heavy hot-water use | Look under the unit without touching wiring and photograph any water | Find and fix the weep, dry and test the connection |
| Control board input fault | Sensor and wiring test good but n06 persists | None | Board diagnosis and replacement only after the other causes are ruled out |
Is it safe to keep running a Lochinvar boiler that shows n06?
Usually the boiler can keep heating the house while n06 is displayed, but hot water is the part to watch. If hot water is merely lukewarm, it is reasonable to live with it for a short time while you book a technician. If it is running hotter than normal, stop using hot water at the taps, warn everyone in the house, and treat it as urgent. Do not keep clearing the notification to get through the week: repeated resets hide the pattern a technician needs to see, and on any boiler a habit of resetting can mask a separate safety problem.
These are the only checks an owner should make, without tools and without opening anything. They will not fix a failed sensor, but they rule out the simple things and give the technician useful information.
- Power and service switch: confirm the boiler’s service switch is on and the breaker has not tripped. Do not work inside the electrical panel beyond resetting a tripped breaker once.
- Gas supply: confirm the gas valve on the pipe leading to the boiler is open, with the handle in line with the pipe. Do not loosen fittings or touch the gas valve inside the boiler.
- Thermostat: confirm the thermostat is calling for heat and has fresh batteries if it uses them, so you know whether heating and hot water are both affected.
- One reset only, and only if your owner manual allows it. Write down whether n06 returns and how long it took.
- Outside vent terminals: check that the intake and exhaust terminals outside are clear of leaves, snow, wasp nests or anything stacked against them.
- Condensate drain: look at the visible condensate line and make sure it is not kinked, disconnected or sitting in a pool of water. Do not take it apart.
- Record the symptoms: when n06 appears, what the hot water was doing and anything else on the display. A photo of the display helps.
When does Lochinvar error code n06 become a licensed technician call?
Stop at the owner checks. Do not remove the front cover, unplug connectors, jumper or bypass the sensor, or fit a replacement part bought online. The cabinet holds the gas valve, burner, ignition and line-voltage wiring. In BC, gas work must be done by a licensed gas fitter and most electrical work by licensed trades. Work done otherwise can create a hazard and can complicate a manufacturer warranty claim.
It becomes a licensed call as soon as any of these is true: n06 returns after one permitted reset, hot water is scalding or swings widely, you see water inside or under the cabinet, the display shows anything else alongside n06, or the heating side has also stopped. At that point the next step is a meter on the sensor circuit, not another reset.
Gas and carbon-monoxide safety: if you smell gas, or a carbon-monoxide alarm sounds, do not operate light switches or the boiler. Leave the home with everyone in it, then call FortisBC or 911 from outside. Every home with a gas boiler should have working CO alarms near sleeping areas, tested regularly. An n06 notification is not itself a gas fault, but any boiler visit is a good time to confirm your alarms work and your venting is sound.
How our Lochinvar boiler n06 repair visit works, step by step
When you call (604) 473-9690, we ask for the code, the symptoms you noted and roughly how old the boiler is. We book a visit and offer same-day where we can; in a cold snap or a busy week it may be the next available slot, and we will tell you honestly which it is rather than promise an arrival window we cannot keep.
Diagnostic service calls are $189.00. If the visit shows the boiler should be replaced and you go ahead with a replacement or new installation through BC Wide, the diagnostic charge is waived and taken off the installation. The in-home estimate for a replacement or new installation is free.
- Step 1, confirm the code and history: the technician reads the display, checks any stored fault history the control keeps and asks what you have noticed. The code meaning is confirmed against the manual for your unit.
- Step 2, safety first: we check accessible gas fittings for leaks, look at the venting and intake, and confirm combustion is behaving before chasing the sensor.
- Step 3, test the sensor circuit with the right meters: the DHW sensor’s resistance is measured and compared with the manufacturer’s published chart at the measured water temperature, then the wiring and connector are checked for continuity and corrosion.
- Step 4, find the real cause: sensor, wiring, mounting, moisture or the control board input. The parts most often involved are the DHW sensor itself, its connector and harness, and its clip or mounting; the control board is involved far less often, and we rule out the simpler causes first.
- Step 5, written quote before any work beyond diagnosis: you see the part needed, the labour involved and what the repair does and does not cover, in writing, before anything else is done.
- Step 6, repair and test: once approved, the part is fitted, hot water is run at more than one tap to confirm stable temperature, and the boiler’s safeties are tested, including flame sensing, venting and the condensate path, before we leave.
- Step 7, paperwork: you get a written record of what we found and did. Where the work needs a permit, such as gas-line changes or a replacement, we pull it and arrange the inspection.
Repair or replace an older Lochinvar combi boiler with an n06 fault?
On its own, n06 is rarely a reason to replace a boiler. A DHW sensor is a modest part and the repair is usually straightforward. The question becomes real when the sensor fault is one of several problems, or when the diagnosis points to the control board on a boiler that is already well into its service life. We weigh the same factors on every older unit and put them in writing.
Age and history come first: how long the boiler has been in, how many repairs it has had, and whether faults are getting closer together. Next is the heat exchanger and water condition. Metro Vancouver water is soft, so the problem we see in hydronic systems is sludge and corrosion rather than limescale, and a heat exchanger fouled by sludge or showing corrosion changes the repair decision far more than a sensor does. Parts availability matters too, because older boards and harnesses can take time to source when you are without reliable hot water. Then there is fit for the house today: a growing family, a renovation that added a bathroom or a suite, or a move to in-floor heat can mean the combi no longer suits how you live. Finally, a replacement may need venting or gas-line changes to meet current code, and an honest replacement quote includes them.
If repair makes sense, we say so and quote the repair. If replacement makes more sense, the in-home estimate is free and you receive written options. Some owners choose a combi again; others prefer a heating boiler with a separate indirect hot-water tank. Who does the work matters: BC Wide is an independent contractor licensed by Technical Safety BC under gas contractor licence LGA0090068, with Class B gas licence CGA0028029, and the work is done by our own licensed gas fitters, with permits and inspections where required. We are not a dealer or warranty centre for Lochinvar or any other manufacturer, so our advice is not tied to selling one brand. Brands we service on combi and hydronic equipment include Lochinvar, Navien, Rinnai, Bosch, Noritz, Takagi, Rheem, Bradford White and A. O. Smith.
Lochinvar boiler n06 repair near me: Greater Vancouver areas we cover
We service Lochinvar combi and heating boilers across Greater Vancouver from our Burnaby base. Housing stock varies a lot across the region and it shapes what we find when we open a boiler cabinet, so here is an honest, general picture rather than a claim about any one street.
- Vancouver: a mix of older houses converted to include suites, laneway homes and townhouses. Combi boilers often sit in tight mechanical closets, where heat and moisture around the cabinet can be harder on wiring and connectors.
- Burnaby and New Westminster: older detached houses alongside many strata townhouses and low-rise buildings, where access, strata rules and vent locations shape the visit.
- Surrey, Delta and Langley: many larger family homes with heavy hot-water demand, where a combi works hard and sensor or wiring wear can show up sooner.
- Richmond: many townhouse complexes and homes with the boiler in a garage or utility room, so we look closely for damp and corrosion at connections.
- Coquitlam and the Tri-Cities: hillside houses next to newer strata developments; we often coordinate access and vent-terminal checks with strata requirements.
- The North Shore: wetter, cooler hillside sites where outside vent terminals can collect leaves and debris, and where older homes may have had their hydronic systems updated more than once.
More questions homeowners ask
What does Lochinvar boiler error code n06 mean?
It is a notification that the domestic-hot-water sensor on a combi model has a fault, which can affect hot-water temperature control. Confirm against the manual for your unit, since display wording can vary by model and software. In practice the boiler cannot trust its hot-water temperature reading, so tap water may run cool, hot or uneven.
Can I reset a Lochinvar boiler n06 code myself?
Only once, and only if your owner manual says a reset is allowed. If n06 returns, stop resetting: the sensor is internal and the fault will keep coming back until the sensor circuit is tested and repaired. Repeated resets also hide the pattern a technician needs for diagnosis.
Is it safe to run my Lochinvar boiler with n06 showing?
Heating often continues, and a short wait for a technician is usually reasonable if hot water is just lukewarm. If hot water is hotter than normal, stop using it and treat it as urgent because of the scald risk. If you smell gas or a CO alarm sounds, leave the home and call FortisBC or 911 from outside.
Will a Lochinvar n06 fault stop my heating?
Not necessarily. The fault is on the hot-water sensor, so on many units heating carries on while hot water is affected; confirm against the manual for your unit. If heating has stopped as well, there may be a second problem, and a licensed technician should diagnose it.
Is a Lochinvar n06 repair covered by warranty?
That depends on the boiler’s age, registration and the manufacturer’s terms, which nobody can state for your unit without the paperwork. Check your registration documents or contact the manufacturer or original installer. We are an independent contractor, not a warranty centre, but we give you a written record of what we found so you can pursue a claim if one applies.
Who repairs Lochinvar boilers near me in Greater Vancouver?
BC Wide services Lochinvar boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor under licence LGA0090068 and offer same-day where we can. Call (604) 473-9690 to book a diagnosis.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.


