Lochinvar Boiler Code n08 — Inlet Sensor Shorted (Notification) | BC Wide

Boilers, Error Codes, Hvac

Lochinvar Boiler Code n08 — Inlet Sensor Shorted (Notification) | BC Wide — BC Wide Heating & Air Conditioning, Greater Vancouver
Home › Lochinvar Boiler Code n08 — Inlet Sensor Shorted (Notification) | BC Wide

Lochinvar Boiler Code n08 — Inlet Sensor Shorted (Notification) | BC Wide

Quick answer

Lochinvar boiler error code n08 is a notification that the inlet (return) temperature sensor circuit is reading shorted while the boiler keeps operating, so you usually still have heat and hot water for now. It is not a reason to keep resetting. Check power, the gas valve and the thermostat, leave every panel closed, and book a licensed technician to test the sensor and its wiring. Confirm the meaning against the manual for your unit, and call (604) 473-9690 for service across Greater Vancouver.

If your Lochinvar boiler is showing n08 (Inlet Sensor Shorted (Notification)), here’s exactly what it means and what to do. This guide is part of our full Lochinvar boiler error code list.

Severity: Needs attention.

What n08 means on a Lochinvar boiler

Notification: the inlet (return) temperature sensor circuit is reading shorted, but the boiler is still operating.

Common causes

  • Faulty inlet temperature sensor
  • Pinched or damaged sensor wiring

What you can safely check first

  1. No safe homeowner action — the sensor is internal
  2. Have a technician check and replace the inlet sensor

Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.

When to call a technician

This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Lochinvar boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.

BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.

Lochinvar boiler repair across Greater Vancouver

If a Lochinvar boiler showing n08 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.

Related Lochinvar boiler codes

Frequently asked questions

Is n08 on a Lochinvar boiler serious?

It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Lochinvar boilers 7 days a week across Greater Vancouver.

How do I reset a Lochinvar boiler after n08?

You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.

Lochinvar boiler error code n08: what it means for your heat, hot water and safety

In plain terms, n08 is the boiler telling you one of its sensors can no longer be trusted. The control watches the water coming back from your radiators, in-floor loops or indirect tank through the inlet (return) temperature sensor. When that circuit reads as shorted, the number the control receives makes no sense. Because this is a notification rather than a lockout, the boiler is still operating, so most homeowners see the code on the display and notice nothing else at first. Confirm the exact meaning against the manual for your unit, since display wording and behaviour can differ between models and software versions.

What it means for your heat: on many modulating condensing boilers the control compares the inlet and outlet readings to judge how much heat the system is taking and how hard the burner should fire. With a bad inlet reading, the boiler may lean on its other sensors and keep running, but heating can become less even, the burner may cycle on and off more than usual, and rooms at the end of a long zone can take longer to come up to temperature. How a particular unit responds varies, so treat any change in comfort as useful information for the technician rather than something to adjust yourself.

What it means for your hot water: if the boiler also heats an indirect domestic hot water tank, that tank depends on the same boiler running correctly. You may notice slower recovery after showers or a tank that does not seem as hot as it used to. A notification code does not usually stop hot water on its own, but a sensor fault that is left alone can be joined by other faults later, and those can stop the boiler.

What it means for safety: a shorted inlet sensor is not, by itself, a gas leak or a carbon monoxide problem. The boiler’s flame, pressure and water-level safeties are separate devices. The reason to book the repair anyway is that the control is now running with less information than it was designed for, and a wiring fault that has shorted one circuit can point to moisture, rubbing or heat damage inside the cabinet that a technician should see before it spreads.

The symptoms homeowners describe to us when n08 is on the screen usually sound like this:

  • The display shows n08 but the house still feels warm
  • The code comes and goes, often after the boiler has been running for a while
  • Radiators or floors heat unevenly, or one zone lags behind the others
  • The boiler seems to turn on and off more often than it used to
  • The indirect hot water tank recovers more slowly after heavy use
  • There is water staining, a drip or green or white corrosion near or under the boiler

Lochinvar boiler error code n08: what we check first, most likely cause to least

The table in this section lists the causes we find behind an inlet sensor short, in the order we most often see them on Greater Vancouver boilers. The first two match what the manufacturer documentation commonly lists; the others are what an experienced installer looks for when the obvious answer does not hold up on the meter. For every one of them, the fix itself is technician work, because it means opening the boiler cabinet and working on control wiring next to the gas train and burner.

Owner-safe checks are about confirming the boiler is otherwise healthy and gathering details that make the visit faster. None of them fix a shorted sensor, and none of them involve opening a panel. If anything in the checks below does not look right, or the code returns after a single permitted reset, stop there and call. Never open the cabinet, unplug or bridge the sensor, jumper anything, or keep cycling the power to clear the display; repeated resets can hide a fault rather than fix it.

Gas and carbon monoxide safety comes first with any boiler code. If you smell gas or a carbon monoxide alarm sounds, leave the home right away, do not operate light switches or appliances on the way out, and call FortisBC or 911 from outside. Keep working CO alarms near sleeping areas and near the boiler room, and test them regularly.

  • Power: confirm the boiler’s service switch is on and the breaker has not tripped. Do not open the electrical box or the boiler’s wiring compartment.
  • Gas: confirm the manual gas shut-off valve to the boiler is open, with the handle in line with the pipe. Do not adjust anything else on the gas line.
  • Thermostat: confirm it is set to heat and is calling above the current room temperature, and replace its batteries if it uses them.
  • Reset: only if the owner manual for your unit allows it, and only once. Because n08 is a notification, a reset may not clear it at all, and that is not a reason to try again.
  • Venting: outside, check the intake and exhaust terminals are clear of leaves, moss, nests, snow or anything stored against them.
  • Condensate: check the visible condensate drain line is connected and not kinked, and that there is no pooling water under the boiler.
  • Notes: photograph the display, write down when the code appears, and note any recent work on the boiler, leaks or new noises.
Likely cause (most common first)What is going onWhat the owner can safely doWhen it becomes a licensed call
1. Failed inlet (return) temperature sensorThe sensing element has broken down internally, so the control reads a short even though the wiring is soundNote the code and when it appears; confirm the house still has heat; do not touch the sensorAlways. The sensor is tested with a meter and replaced by a technician, then the boiler is re-tested
2. Pinched, chafed or damaged sensor wiringInsulation on the sensor leads has worn through against a sharp edge, pipe or bracket, so the conductors touchLook from outside the cabinet only and leave every panel closedAlways. Wiring inside the cabinet is repaired or replaced by a technician
3. Moisture or corrosion at the sensor connectorA drip from a weeping fitting, relief valve or condensate leak has wet the connector and created a path between the terminalsLook for drips, staining or a wet floor around the boiler and tell us what you seeAlways. Both the leak source and the damaged connector need attention
4. Loose or damaged harness connectionA plug disturbed during earlier work, or loosened by vibration over time, gives an erratic readingNothing inside the cabinet; mention any recent work done on the boilerAlways. Connections are checked, cleaned and re-seated by a technician
5. Control board input fault (least common)The sensor and wiring test good but the board is misreading that inputNothing; this is only found by testingAlways. Board diagnosis and replacement is technician work and one of the more expensive repairs, so you get a written quote first

How our Lochinvar boiler n08 repair visit works, step by step

An n08 visit should involve very little guesswork when it is done properly. Diagnostic service calls are $189.00. That covers a licensed technician coming out, finding the cause and explaining it to you before anything else happens. We aim for same-day where we can, depending on the day’s calls, travel and how much heat you have. Because n08 is a notification and the boiler is usually still running, we will tell you honestly when the next available slot is the better plan, and we never promise a guaranteed arrival window.

Here is how the visit runs from the phone call to the paperwork:

  • Step 1, booking: we ask for the code, the model information from the rating plate if you can read it without opening anything, what heats your domestic hot water, and whether the home is still warm.
  • Step 2, safety first on arrival: the technician checks for gas odour, asks about your CO alarms and looks at the venting and condensate path before the boiler is opened.
  • Step 3, reading the control: we read the active code and the fault history the boiler has stored, which often shows whether n08 is new, intermittent or has been building for weeks.
  • Step 4, testing with the right meters: the inlet sensor is checked against the manufacturer-published resistance and temperature chart for your model, and the wiring is checked end to end for a short, a chafe or moisture. Comparing the inlet reading with the outlet reading and the actual pipe temperature tells us whether the sensor, the wiring or the board is at fault.
  • Step 5, a written quote before any work beyond diagnosis: you see what failed, what we recommend and what it will cost, in writing. Nothing is replaced until you agree.
  • Step 6, the repair: most often a replacement inlet sensor, sometimes a section of wiring or a connector, and occasionally a fix to the leak that caused the moisture damage in the first place. Parts are matched to your model; we do not fit generic substitutes where the manufacturer specifies a part.
  • Step 7, testing the safeties after the repair: we run the boiler through a full heat call, confirm the code has cleared and stays cleared, check combustion, confirm system pressure, the relief valve and low-water protection are behaving, and confirm the vent joints are sealed.
  • Step 8, paperwork: you get a written record of what we found, what we did and anything worth watching, such as sludge in the system water or a circulator that is getting noisy.

Repair or replace: what an n08 code means for an older Lochinvar boiler

On its own, n08 is rarely a reason to replace a boiler. An inlet sensor is a modest part and the repair is routine. The question changes when the code shows up on an older boiler with other problems, because the visit that finds the sensor fault often uncovers the bigger story too.

Repair is usually the right call when the boiler is in the middle of its working life, the heat exchanger is clean and sound, combustion tests well and the only finding is the sensor or its wiring. Fix it, test it and keep going.

It is worth getting a replacement estimate when the boiler is near the end of its expected service life, the heat exchanger shows corrosion or heavy sludge, there have been repeated lockouts or several different faults over the last few heating seasons, parts for that generation are getting hard to source, or the control board itself is failing. A board on a modulating condensing boiler is one of the more expensive repairs, and on an old unit that money may be better put toward new equipment.

If you are weighing it up, we give you both options in writing: the repair quote and an in-home estimate for replacement, which is free. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. A replacement is also the chance to correct what older installs often got wrong: poorly routed or poorly pitched venting, no system cleaning when the boiler was changed, no dirt or magnetic separator on a sludgy system, and controls that were never set up for outdoor reset.

What you should see in writing on any boiler replacement quote:

  • The proposed boiler make and model, sized from a room-by-room heat-loss calculation rather than copied from the old rating plate
  • The venting route and materials, and whether any existing venting can be reused
  • System flushing or cleaning, and whether a dirt or magnetic separator is included
  • The gas permit and inspection from the authority for your address (Technical Safety BC, or the city in the City of Vancouver), plus electrical permits where needed
  • Removal and disposal of the old boiler
  • Start-up, combustion testing and control setup, including outdoor reset and indirect tank settings where fitted

Lochinvar boiler n08 service near me: Greater Vancouver areas we cover

We service Lochinvar boilers showing n08 across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Our base is in Burnaby, which keeps travel reasonable to most of the region.

Housing stock shapes what we find. Many older homes in Vancouver, Burnaby and New Westminster have hydronic systems that started life on a cast-iron boiler and were later converted to a high-efficiency condensing unit, and those systems can carry years of sludge that is hard on sensors, circulators and heat exchangers. On the North Shore and in parts of Coquitlam, homes built on slopes often have long piping runs and several zones, so an uneven or lagging zone is one of the first things owners notice. Newer townhouses and strata buildings in Surrey, Richmond, Langley and Delta frequently tuck the boiler into a tight closet or mechanical room, where access and the venting route decide how long a repair takes.

Strata owners should check with their strata manager before work in a shared mechanical room or on a building vent, and we can provide the paperwork a strata asks for. Our wet coastal climate matters as well: winters are mild but long and damp, so boilers run for much of the year, and outdoor vent terminals collect leaves and moss far more often than snow. Metro Vancouver water is soft, so hydronic trouble here is usually sludge and corrosion rather than scale, which is exactly why a moisture or corrosion-related sensor fault deserves a proper look.

Who to call for Lochinvar boiler error code n08: an independent TSBC-licensed contractor

BC Wide Home Services is an independent contractor licensed by Technical Safety BC, gas contractor licence LGA0090068 and Class B gas licence CGA0028029. We are not a Lochinvar dealer, authorized service centre or warranty centre. If your boiler may still be under manufacturer warranty, check the warranty terms and registration first, because some claims have to go through a specific channel; we will help you gather the details either way.

Boiler brands we service include Lochinvar, IBC, Weil-McLain, Navien, Rinnai and Bosch. We service these brands as an independent contractor and are not certified by or affiliated with any of them.

What you can expect from us on any boiler code visit:

  • Licensed gas fitters on our own team carry out the diagnosis and repair
  • Permits and inspections are taken out wherever the work requires them
  • A written quote before any work beyond the diagnosis
  • Manufacturer procedures followed for testing, parts and start-up
  • A plain-language explanation of what failed, with the old part shown to you on request
  • Serving Metro Vancouver homeowners since 1999
  • To book, call (604) 473-9690 with the code, the model information if you can read it from outside the cabinet, and a short note on what the boiler has been doing

More questions homeowners ask

What does n08 mean on a Lochinvar boiler?

It is a notification that the inlet (return) temperature sensor circuit is reading shorted while the boiler keeps operating. The usual causes are a failed inlet sensor or pinched or damaged sensor wiring. Confirm the meaning against the manual for your unit and have a licensed technician test the sensor and its wiring.

Can I reset a Lochinvar boiler showing error code n08?

Only if the owner manual for your unit allows a reset, and only once. Because n08 is a notification about a sensor circuit, a reset usually will not fix the cause and the code may come straight back. Do not keep cycling the power, open the cabinet or unplug the sensor; book a technician instead.

Is it safe to run my Lochinvar boiler with an n08 code?

The boiler is designed to keep operating with this notification, so in most cases it is reasonable to keep the heat on while you book a repair. Watch for changes in comfort, hot water or new codes, and make sure your CO alarms work. If you smell gas or a CO alarm sounds, leave the home and call FortisBC or 911 from outside.

How much does it cost to fix Lochinvar boiler error code n08?

The repair cost depends on what testing finds, so we diagnose first and quote second. A replacement inlet sensor is usually one of the simpler boiler repairs, while a control board is one of the more expensive. You get a written quote before any work beyond the diagnosis.

Can you fix a Lochinvar n08 code the same day in Greater Vancouver?

Same-day where we can. It depends on the day’s calls, where you are and whether the right part for your model is on hand. Because the boiler usually keeps running with n08, we will tell you honestly when the next available slot is the better plan, and we never promise a guaranteed arrival window.

Does an n08 code mean my Lochinvar boiler needs replacing?

Usually not. A shorted inlet sensor or damaged sensor wiring is a routine repair on a boiler that is otherwise sound. Replacement only comes into the conversation when an older boiler also shows heat exchanger corrosion, heavy sludge, repeated faults or a failing control board, and then you get a repair quote alongside an in-home replacement estimate.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a boiler be serviced?
Annual servicing is recommended for all residential boilers. BC Wide's annual service includes combustion analysis, heat exchanger inspection, expansion tank pressure check, condensate trap cleaning, and a full safety check. Annual maintenance is also required to keep most manufacturer warranties valid.
How much does a new boiler cost in Vancouver?
A typical residential high-efficiency gas boiler in Metro Vancouver costs $7,500–$15,000 installed, depending on size, brand, and whether the system is heating only or a combi unit that also handles hot water. BC Wide provides a free written quote with three options at different price points.
How long does a boiler last?
A well-maintained cast-iron boiler can last 25–30 years, a modern high-efficiency condensing boiler typically lasts 15–20 years, and a combi boiler 12–18 years. Annual servicing has the single biggest impact on lifespan.
My boiler is making a banging or kettling noise. Is that dangerous?
Kettling (a banging or whistling sound) is usually caused by limescale build-up on the heat exchanger and is a sign the system is overheating in localised spots. It will not always cause immediate failure but it shortens the life of the boiler and should be addressed within a few weeks.
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Yes. BC Wide is one of the few HVAC companies in the Lower Mainland with deep experience on European and high-end North American boilers including Viessmann, IBC, Baxi, Laars, Weil-McLain, NTI, Navien and Rinnai. We carry common parts in the truck.
Should I repair or replace my old boiler?
A useful rule: if the boiler is more than 15 years old and the repair cost is more than 50% of replacement, replacement is the better investment. BC Wide will give you both a repair quote and a replacement quote and let you decide.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote