Why Is Your Lochinvar Combi Boiler Showing Error Codes?
A Lochinvar combi boiler error code means the control has held or locked out the burner to protect the boiler, your heating or your hot water. The cause is usually ignition, venting, water pressure, a sensor or the condensate drain. Write down the exact code and the model on the rating plate. Then check the power, the gas valve, the thermostat, the pressure gauge, the outside vent and the condensate line. Reset once, and only if the manual allows it. If the code comes back, call a licensed gas fitter.
- Learn the difference between a temporary blocking condition and a hard lockout that needs a manual reset.
- Most fault-code calls fall into a few families: ignition, venting, low water pressure, sensors, hot water production, and condensate drainage.
- Check the pressure gauge and condensate line, and reset the boiler once — repeated resets mask the real problem.
- Coastal patterns matter: condensate lines freeze during Arctic outflow cold snaps, and sidewall vents collect moss and wind-driven rain.
- Exact codes vary between Lochinvar control generations, so record the code shown and the rating-plate model before calling.
- BC Wide is a Technical Safety BC licensed gas contractor (LGA0090068) with Red Seal technicians across Metro Vancouver.
A fault code on a Lochinvar combi boiler has a talent for bad timing. The display starts flashing on the coldest morning of a Fraser Valley outflow wind, or the shower runs cold in a Burnaby condo twenty minutes before work. The reassuring part is that Lochinvar’s control platform is among the more communicative in the industry: it distinguishes temporary holds from hard lockouts, stores a history of recent faults, and usually points a trained technician toward the right subsystem before the boiler’s front panel ever comes off.
BC Wide Heating & Air Conditioning has worked on gas heating equipment across Greater Vancouver since 1999. As a Technical Safety BC licensed gas contractor (licence LGA0090068) with Red Seal technicians, we diagnose Lochinvar combi faults in everything from high-rise mechanical closets in Vancouver and Coquitlam to converted radiator systems in Kitsilano character homes.
One caution before we begin: Lochinvar has used several generations of controls across its combi lineup, and the exact code on your display depends on the specific model and control version installed. Rather than reproduce a code table that may not match your boiler, this guide is organized around fault categories — ignition, venting, water pressure, sensors, domestic hot water and condensate — because that is how a technician actually works through a diagnosis.
How Lochinvar Combi Controls Report Trouble
Faults come in two flavours. A blocking condition is a temporary hold: the control sees something out of range — a brief pressure dip, a temperature rising faster than it should — pauses the burner, and retries automatically once the condition clears. A lockout is more serious: the control has seen something safety-relevant, such as repeated failed ignition attempts or a limit trip, and it will not restart until someone manually resets it.
A blocking condition that clears itself once a season is usually nothing; a lockout, or a blocking code that recurs daily, means a component or condition is deteriorating. The control also stores a fault history, which our technicians read on arrival — a pattern over weeks often tells a clearer story than the single code on the screen. One reset after a lockout is reasonable; repeated resets stress the ignition components and delay diagnosis. Before you phone, note a few things down.
- The exact code or message on the display
- What the boiler was doing when it faulted — heating, making hot water, or idle
- How often it happens, and whether it clusters around cold weather
- The reading on the boiler’s pressure gauge
- The model designation on the rating plate
Ignition and Flame Failure: The Most Common Hard Lockout
Every burner start follows the same choreography: the fan proves airflow, the gas valve opens, the igniter sparks, and a flame-sensing circuit must confirm a stable flame within a short window. If flame cannot be proven after the allowed attempts, the control locks out. From the homeowner’s side, the boiler clicks and whirs, sometimes lights briefly, then goes quiet with an ignition or flame-failure fault.
The causes we find most often are worn or carbon-fouled electrodes, a weak flame-sensing signal from poor grounding, a dirty burner, and gas supply problems — a partially closed valve after renovations, or supply pressure sagging when other appliances fire simultaneously. In condensing combis there is one more suspect: condensate backing into the combustion side, which disturbs the flame and mimics a gas problem.
Our diagnosis reflects that list: manometer readings under static and firing conditions, electrode inspection and replacement, flame-current verification, burner cleaning where warranted, and a closing combustion analysis. The same lockout code can come from four different root causes, so we measure rather than swap parts on a guess.
Venting and Combustion-Air Faults in a Coastal Climate
Condensing combis use sealed plastic venting for both exhaust and combustion air, and the control constantly proves that air is moving as expected. A blocked termination, a fan not reaching commanded speed, or a proving device that will not close all produce venting or fan faults, and the boiler refuses to fire until airflow is restored.
The Lower Mainland gives these faults local character. Sidewall terminations collect moss and cedar debris, screens clog with insect nests, and exposed North Shore installations take wind-driven rain straight into the termination during winter storms. In condo mechanical closets we also see long concealed vent runs where inadequate slope lets condensate pool in a horizontal section — the classic symptom is gurgling followed by intermittent fan faults.
We inspect terminations first, then work back along the run: slope, support, pooled condensate, then fan and proving-device tests against specification. Where venting must be altered, that is a regulated gas alteration in British Columbia, and we handle the Technical Safety BC permit as part of the job — something strata councils should insist on seeing.
Low Water Pressure, Leaks and Circulation Faults
A combi’s heating circuit is a sealed, pressurized loop, and when pressure falls below minimum the boiler shuts down to protect the pump and heat exchanger from running dry. Check the gauge first: if it reads near the bottom of the scale, the code is telling the truth. Topping up once through the filling loop is a reasonable homeowner action — but if pressure drops again within days, water is leaving the system somewhere, and endlessly adding fresh water accelerates corrosion.
In Vancouver’s character homes, where combis often serve original cast-iron radiators, the leak is frequently a weeping radiator valve, an old union, or a hidden crawlspace pipe run. A subtler culprit is the expansion vessel: when its air charge is lost, pressure swings sharply between cold and hot, and the boiler throws faults that seem random until someone checks the vessel’s charge.
Circulation faults are the other side of the coin. A pump seized over the summer idle, an air lock after service, or a strainer choked with debris all prevent heat from moving away from the boiler, so the control sees temperature climbing too fast and shuts down. Noisy operation, uneven radiators and rapid cycling are the supporting evidence.
Temperature-Limit and Sensor Faults
Lochinvar combis carry layered temperature protection: an outlet high-limit function, flue-temperature monitoring, and cross-checks between sensors. A genuine limit trip almost always means heat is being made faster than it is carried away — which points back to circulation, not the limit device. Replacing a limit switch without asking why it tripped is how the same fault returns a month later.
Metro Vancouver has one advantage here: our mountain-fed water is naturally soft, so mineral scale matters less than in hard-water regions. The dominant local fouling problem is magnetite — fine black iron-oxide sludge from older steel and cast-iron radiator circuits converted to a condensing combi. It settles in the boiler’s narrow waterways, restricting flow and driving limit trips. A proper system cleanse and a magnetic filter on the return line are the standard remedies on any radiator conversion.
Sensor faults are their own category: the control flags a sensor as open or shorted when its resistance falls outside the plausible range. Sometimes the sensor has failed; at least as often the fault is wiring or a corroded connector — common in damp parkade-level mechanical rooms. We test against the manufacturer’s resistance-temperature data before condemning any component.
Hot Water Faults on the Combi Side
What makes a combi a combi is instantaneous hot water: a flow sensor detects a tap opening, a diverter valve redirects boiler output through a plate heat exchanger, and the burner modulates to hold delivery temperature. Each element can fail, and the result is sometimes a displayed code but just as often a symptom without one.
The symptoms map to causes fairly reliably. No hot water while heating still works points at a diverter stuck in the heating position or a flow sensor that no longer registers demand. Water cycling hot and cold suggests plate-exchanger fouling, an erratic flow signal, or crossflow at a failed mixing valve elsewhere. Merely lukewarm water at higher flow often reflects fouling compounded by winter conditions — coastal mains water is genuinely cold in January, and an exchanger that coped in September cannot keep up.
We verify flow detection, test the diverter electrically and mechanically, isolate the plate exchanger to assess restriction, and check external mixing valves — a frequent complication in condo closets where several trades have worked over the years.
Condensate Faults: The Quiet Cause of Winter Lockouts
A condensing combi extracts so much heat from its flue gases that water vapour condenses inside the boiler, and that mildly acidic condensate must drain continuously through a trap. When the trap or line blocks, condensate backs up — and the symptoms are deceptive: gurgling, an unstable flame, and ignition lockouts that look like a gas problem.
The coastal pattern makes this predictable. Most of the winter stays mild and wet; then an Arctic outflow arrives, and every condensate line routed through an unheated garage or along an exterior wall becomes a freezing candidate — precisely when the boiler works hardest. The signature is a boiler that locks out overnight during a cold snap and restarts obediently once the afternoon warms up.
The durable fix is routing: we move vulnerable runs indoors where possible, insulate those that must stay outside, clean the trap and any neutralizer at annual maintenance, and make sure the discharge point complies with drainage rules — a detail strata councils care about, since condensate discharge onto walkways is a recurring source of building disputes.
Symptom, Likely Cause and What BC Wide Does
The table below is a first-look reference, not a substitute for diagnosis — the same symptom can have several causes, and a licensed technician confirms with measurements. If your symptom is not listed, or two appear together, resist the urge to keep resetting: note the code and let the stored fault history do its job when the technician arrives.
| Symptom | Likely cause | What BC Wide does |
|---|---|---|
| Repeated ignition lockouts — clicks and fan noise but no flame | Worn electrodes, weak flame signal, or a gas supply problem | Measure gas pressures, replace ignition components, verify flame current, run combustion analysis |
| Lockouts only during cold snaps, clears in daytime | Frozen or blocked condensate line, iced vent termination | Thaw and clear the line, then re-route or insulate it; verify vent terminations |
| Pressure gauge near the bottom with a low-pressure code | Heating circuit leak or failed expansion vessel | Pressure-test the circuit, repair the leak, recharge or replace the vessel |
| Boiler heats up quickly then trips a limit | Circulation restriction, magnetite sludge, air lock or failing pump | Cleanse and flush the circuit, fit a magnetic filter, test or replace the pump |
| Hot water fluctuates between hot and cold | Fouled plate heat exchanger or flow-sensing fault | Isolate and assess the exchanger, test the flow sensor and diverter valve |
| Fan runs but the burner never lights | Vent blockage or air-proving fault | Inspect terminations and the vent run, test fan speed and proving devices |
| Gurgling noises before a lockout | Condensate backing up in the trap or heat exchanger | Clean the trap and neutralizer, correct drain slope and routing |
| The same code returns after every reset | A genuinely failed component, not a nuisance trip | Read the fault history, test the indicated subsystem, replace the confirmed part |
How a BC Wide Diagnostic Visit Works — and How Quickly Parts Arrive
A fault-code call follows a consistent structure: read the displayed code and stored history, verify the fundamentals many codes depend on — gas supply pressure, water pressure, condensate drainage — then narrow to the subsystem the evidence indicates. Any repair touching the combustion side finishes with a combustion analysis, because a boiler that starts is not the same as a boiler burning correctly. Where the work amounts to a regulated gas alteration under Technical Safety BC rules, we pull the permit — that is part of what hiring a licensed gas contractor means.
Parts sourcing for Lochinvar equipment in the Lower Mainland is well established. Common wear items — electrodes, sensors, gaskets, condensate traps — move through local wholesale channels routinely and can usually be obtained quickly. Model-specific components such as control boards, gas valves and heat exchangers can take longer depending on the unit’s generation, which is why we confirm the rating-plate model before ordering: the biggest avoidable delay in boiler repair is a wrong part arriving for a lookalike model.
We run these calls across Vancouver, Burnaby, Richmond, Surrey, Coquitlam, the Tri-Cities and the North Shore. For strata buildings we coordinate mechanical room access and resident notice with the property manager in advance — a locked penthouse mechanical room has delayed more boiler repairs than any parts shortage.
Repair or Replace: When a Code Is Telling You Something Bigger
Most fault codes end in a straightforward repair: one component tested, confirmed and replaced. But some patterns deserve a broader conversation — recurring heat-exchanger-related faults on an older unit, corrosion from years of marginal condensate drainage, several unrelated faults in a single season, or control parts becoming hard to source for an early-generation model.
Our framing is deliberately conservative: if the fault is isolated and the boiler otherwise sound, repair it. Replacement earns consideration when repairs start to recur or a strata is already planning mechanical upgrades and can fold the boiler into scope — noting that replacement triggers a fresh Technical Safety BC installation permit and often venting upgrades to current code. Either way, the sequence is the same: licensed diagnosis first, decision second. A fault code is data, not a verdict.
Frequently asked questions
Can I reset my Lochinvar combi boiler myself when it shows a fault code?
Yes — once. Note the exact code first, then reset or power-cycle the boiler. If it runs normally, keep an eye on it. If the same code returns, stop resetting: repeated attempts stress the ignition components and mask the pattern a technician needs. At that point call BC Wide at 604-473-9690 with the code, the rating-plate model and the pressure gauge reading ready.
Why does my boiler only lock out during cold snaps?
That pattern almost always points to condensate. During Arctic outflow events, condensate lines routed through garages or along exterior walls can freeze, backing acidic condensate into the boiler and causing flame instability and lockouts. Iced vent terminations produce a similar signature. A boiler that restarts fine in milder weather is the giveaway — the fix is thawing, then permanently re-routing or protecting the vulnerable run.
Do error codes mean the same thing on every Lochinvar combi model?
No. Lochinvar has used multiple control generations across its combi lineup, and the same displayed code can mean different things on different units. Writing down the exact code together with the rating-plate model matters more than searching a generic code list online. Our technicians confirm meanings against the documentation for your specific model before drawing conclusions.
Is a fault code dangerous? Should I shut off the gas?
A lockout is the boiler doing its job — the control detected something out of range and put the appliance into a safe, non-firing state, so you do not normally need to shut off the gas. The exception is unrelated to codes: if you ever smell gas, leave the building, avoid switches and open flames, and contact FortisBC’s emergency line first. Fault diagnosis can wait; a suspected gas leak cannot.
Does boiler repair in BC require a permit?
It depends on scope. Like-for-like replacement of a minor component during service is handled under the gas contractor’s licence, while a regulated gas alteration — changing venting, replacing the appliance, modifying gas piping — requires a Technical Safety BC permit. BC Wide determines what the job requires and pulls the permit when needed; strata councils should ask any contractor to confirm permitting in writing.
Several suites in our strata show boiler faults at the same time — is that a building problem?
Quite possibly. When multiple units fault together, we look for shared causes first: building gas supply pressure sagging under simultaneous demand, a shared venting or make-up air issue, water pressure changes after plumbing work, or a cold snap freezing several similarly routed condensate lines at once. A single diagnostic visit examining the pattern across suites is far more efficient than treating each boiler in isolation, and it is how we structure strata service calls.
BC Wide Heating & Air Conditioning — serving Greater Vancouver since 1999
Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians. Call 604-473-9690 or book a free replacement estimate.
Lochinvar Combi Boiler Error Code Guide: What the Code Means for Your Heat and Hot Water
Whatever the exact wording on the display, a code on a Lochinvar combi boiler means the same thing to you as the owner. The control has found something outside its safe operating window, so it has stopped, slowed or held the burner. A combi boiler makes space heat and domestic hot water with one burner and one heat exchanger, so one fault usually takes out both at once. Code lists differ between control generations, so check what your specific code means in the manual for your unit.
For you, it comes down to three questions. Do you still have heat? Do you still have hot water at the taps? Is there any sign of a safety problem, such as a gas smell, a carbon monoxide alarm, water on the floor or soot around the vent? The first two are about comfort and can usually wait for a booked visit. The third cannot wait.
These are the symptoms homeowners describe to us when they call about a Lochinvar combi boiler error code, in their own words:
- The display is flashing and the radiators or in-floor loops are going cold.
- The heat works, but the shower runs lukewarm or turns cold partway through.
- The boiler tries to light, clicks or whooshes, stops, and then tries again.
- It ran fine all night and then locked out on the first really cold morning of the week.
- There is gurgling inside the boiler, or a drip or puddle under the condensate line.
- The pressure gauge needle sits lower than it used to, or keeps dropping.
- The code clears after a reset, then comes back within hours or days.
What Can I Safely Check When My Lochinvar Combi Boiler Shows an Error Code?
Here are the likely causes, listed in the order we most often find them on Greater Vancouver calls, with the checks an owner can safely make for each. None of these checks involve removing a cover. If a check does not clear the problem, stop there and write down what you saw. Those notes shorten the diagnosis.
Reset once, and only if your owner manual describes a reset for that code. A second or third reset fixes nothing. Each failed attempt repeats a cycle the control was designed to stop, and it can hide the real fault or make it worse. Never open the front panel, bypass a switch, jumper a sensor or run the boiler with the cover off.
| Likely cause (most common first) | Owner-safe check | When it becomes a licensed call |
|---|---|---|
| 1. Condensate drain blocked or frozen | Look at the visible condensate line and the spot where it drains. Note kinks, ice, a hose that has come loose, or water pooling under the boiler. | When the line looks clear but the code returns, or when the trap or neutralizer needs to be opened, cleaned or replaced. |
| 2. Low system water pressure | Read the pressure gauge and compare it with the range marked on the gauge or in the manual. Look for drips at the valves and fittings you can see. | When pressure is low, keeps dropping, or the relief valve is discharging. Refilling the system and finding the leak are technician work. |
| 3. Blocked intake or exhaust terminal | From outside, look at the vent terminals for snow, leaves, moss, nests, or plastic sheeting left from renovation work. | When the terminals are clear and the code continues, or any vent pipe is cracked, sagging or separated. |
| 4. Ignition or flame failure | Make sure the gas shut-off valve to the boiler is open (handle in line with the pipe) and that the other gas appliances in the home are working. | Any repeat lockout after one permitted reset. Igniters, flame sensors and gas valves are licensed gas work. |
| 5. Power or thermostat problem | Make sure the boiler switch and the breaker are on. Make sure the thermostat is set to heat, is set above room temperature, and has fresh batteries. | When the breaker trips again, or the display is blank even though the boiler has power. |
| 6. Sensor, limit or circulation fault | Note whether radiators or floor zones heat unevenly or the boiler cycles on and off quickly. Record the code and when it shows up. | Always. Sensors, pumps and limit controls are diagnosed with meters by a licensed technician. |
When Does a Lochinvar Combi Boiler Error Code Need a Licensed Gas Fitter?
Gas and carbon monoxide safety comes first. If you smell gas (a rotten-egg odour) or a carbon monoxide alarm sounds, do not reset the boiler and do not operate light switches. Get everyone out of the home, then call FortisBC or 911 from outside. Do not go back in until you are told it is safe. Any home with a gas boiler should have working carbon monoxide alarms near the sleeping areas. Test them when you test your smoke alarms.
Call a licensed technician when the code returns after one permitted reset or the boiler locks out again and again in cold weather. Call too if there is water on the floor, the relief valve is dripping or the pressure reading keeps falling. Soot, scorching or condensation around the vent where it should not be is another reason to call. So is banging, kettling or loud gurgling. Any code that points to ignition, flame, venting or a temperature limit is a licensed call from the start.
In BC, work on the gas valve, burner, ignition system, venting and gas piping must be done by a licensed gas fitter working for a contractor licensed by Technical Safety BC. Most electrical work inside the boiler is also licensed work. For an owner, safe means looking, writing down what you see, and the single reset your manual describes. Everything behind the cover belongs to the technician.
Metro Vancouver’s soft water shapes what we find inside these boilers. Heating-loop trouble here is usually sludge, magnetite and corrosion debris circulating through the loops, not hard-water limescale. On the hot-water side of a combi, deposits are modest and come mainly from heat. That is why a circulation or temperature code on an older system often traces back to the condition of the heating-loop water rather than the boiler’s electronics.
Lochinvar Combi Boiler Error Code Service: What Happens From Your Call to a Working Boiler
Diagnostic service calls are $189.00. Here is what that visit covers and what you should see the technician do.
- 1. Your call. Tell us the code exactly as it appears, the model from the rating plate, when the problem started and what you have already checked. We book same-day where we can. During a cold snap, demand rises, and we will tell you honestly when our first realistic opening is.
- 2. Safety on arrival. Before any repair work, the technician checks for gas leaks and carbon monoxide at the boiler and the vent.
- 3. Reading the control. We pull the stored fault history as well as the current code, because the pattern of recent faults often points to the real cause.
- 4. Measuring, not guessing. Depending on the fault, this can mean a combustion analysis, gas pressure at the valve, flame signal, sensor resistance, voltage at the control and system water pressure. We also inspect the condensate path and the full vent run.
- 5. Finding the part or condition. In general terms, the parts most often involved are the igniter and flame sensor, the condensate trap and line, temperature sensors and limits, the circulator or the hot-water diverter parts, and the pressure-sensing parts. Less often it is the control board or the gas valve.
- 6. A written quote before any work beyond diagnosis. You get the finding, the recommended repair and the price in writing. Nothing goes ahead until you approve it.
- 7. Repair, then test the safeties. We run the boiler through both a heating call and a hot-water call, confirm the flame and combustion readings, check the limit and pressure safeties, and clear the fault history so any new fault stands out.
- 8. Paperwork you keep. You get a written record of what we found, what we did and anything we recommend watching.
Who Should Fix a Lochinvar Combi Boiler Error Code? Licensing, Permits and Quotes in Writing
BC Wide Home Services Ltd is an independent contractor licensed by Technical Safety BC, under licence LGA0090068 and Class B gas licence CGA0028029. Our gas work is done by licensed gas fitters, and we have worked on gas heating in Metro Vancouver since 1999. We are not an authorized dealer or warranty centre for Lochinvar or any other manufacturer. Lochinvar is a brand we service. If your boiler may still be under the manufacturer’s warranty, start with the warranty process in your paperwork, and we can document our findings to support the claim.
Here is what a correct job looks like in writing: the code and fault history we found, the readings that confirmed the cause, the repair you approved and the price, all before the work starts. When the job needs a gas permit, such as a boiler replacement or changes to the gas piping or venting, we take out the permit, and the work is open to inspection.
On an older Lochinvar combi that keeps throwing codes, the honest answer is sometimes replacement rather than another repair. Signs that point that way include heat-exchanger corrosion, discontinued parts, or sludge damage that keeps coming back. In that case we give you both options in writing. The in-home estimate for a replacement or new installation is free. If you go ahead with the replacement through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.
Besides Lochinvar, these are the combi boiler and tankless brands we service. We name them here as brands we service, not brands we are certified by:
- Lochinvar
- Navien
- Rinnai
- Noritz
- Bosch
- A. O. Smith
- Rheem
- Bradford White
- Takagi
Lochinvar Combi Boiler Error Code Repair Near Me: Greater Vancouver Coverage
We take Lochinvar combi boiler error code calls across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. The housing in each area affects which codes we tend to see.
In Vancouver and Burnaby, many combi boilers sit in older houses that were converted from an earlier heating system. It is common to find a newer boiler connected to old radiator or in-floor loops, and the condition of those loops often drives circulation and temperature codes. Basement mechanical rooms in these homes can also be tight, which makes vent routing and condensate drainage harder to get right.
In New Westminster, Richmond, Burnaby and the Tri-Cities, a lot of combi boilers serve townhouses and strata units. In these homes the vent often ends on a sidewall or balcony close to neighbours’ windows and walkways. Strata rules can affect access to the vent terminal and the shared spaces where it runs, so tell us when you book if a building manager needs notice.
Homes higher up on the North Shore tend to get more snow and longer cold spells than the rest of the region. That is often where frozen condensate lines and snow-blocked terminals show up first. In Surrey, Delta and Langley, outflow winds from the Fraser Valley can drive rain and cold air into sidewall vents. Housing there ranges from older acreage homes to newer subdivisions, so boiler age and installation quality vary widely.
Across the region, our mild, wet coastal climate is the common factor. Moss and debris build up on vent terminals, damp mechanical spaces are hard on electrical connections, and a few hard freezes each winter catch condensate lines that were never protected. When you call, tell us your area and where the vent ends outside. It helps us plan the visit.
More questions homeowners ask
What does a Lochinvar combi boiler error code mean?
It means the boiler’s control has found a condition outside its safe limits and has held or locked out the burner. Most codes fall into a few groups: ignition, venting, water pressure, sensors, hot water or condensate. The exact meaning depends on your control generation, so check it against the manual for your unit and write the code down before you call.
Can I reset a Lochinvar combi boiler error code myself?
Yes, once, and only if your owner manual describes a reset for that code. If the code comes back, stop resetting and call a licensed technician, because repeated resets hide the cause and can make some faults worse. Never reset the boiler if you smell gas or a carbon monoxide alarm is sounding.
Is it safe to run my Lochinvar combi boiler with an error code showing?
A boiler in lockout is not running, which means the control is doing its job. It is not safe to force it to run with repeated resets, by bypassing a sensor, or with the covers off. If there is a gas smell, a carbon monoxide alarm, a water leak or soot at the vent, leave the boiler off and call.
How much does a Lochinvar combi boiler diagnostic cost in Greater Vancouver?
Our diagnostic service call is $189.00. Any repair beyond the diagnosis is quoted in writing before work begins. If the diagnosis leads you to replace the boiler and you go ahead with the replacement through BC Wide, the $189.00 diagnostic charge is waived and the in-home replacement estimate is free.
Who repairs Lochinvar combi boilers near me in the Lower Mainland?
BC Wide services Lochinvar combi boilers in Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We book same-day where we can, and we tell you honestly when that is not possible. Call (604) 473-9690 with the code and the model from the rating plate.
Is BC Wide a Lochinvar authorized dealer or warranty centre?
No. BC Wide is an independent contractor licensed by Technical Safety BC (LGA0090068, gas licence CGA0028029), and Lochinvar is a brand we service, not a brand we are authorized by. If your boiler may still be under warranty, check the manufacturer’s process in your paperwork first, and we can document our findings to support the claim.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.