- Depending on the exact model, the Knight parts that most often need replacing are the igniter, flame sensor, gas valve, combustion blower, circulator, water pressure sensor, control board and condensate trap.
- Combustion and control parts should be brand-matched to the rating-plate model and serial; circulators, expansion tanks and relief valves are matched by specification instead.
- In Metro Vancouver the water is soft, so heating-side trouble on these boilers is usually sludge and corrosion, not scale.
- Homeowners can check the thermostat, service switch, breaker and pressure gauge; all gas, combustion and wiring work belongs to a licensed technician.
- Repeat failures, heat exchanger problems or several costly parts failing together are reasons to assess the whole boiler before ordering anything.
If you have been told a part on your Lochinvar Knight boiler has failed, it is most likely the igniter, the flame sensor, the combustion blower, the gas valve, a circulator pump, the water pressure sensor, the control board or the condensate trap, depending on the exact model and generation. Most of these can be replaced on their own without replacing the boiler. Combustion and control parts should be matched to your unit’s rating-plate model and serial number, while pumps and some hydronic accessories are matched by specification rather than brand. Before any part is ordered, a licensed technician should confirm the diagnosis, find out what caused the failure and give you a written quote. BC Wide Home Services is an independent TSBC-licensed contractor in Burnaby that services the Knight family across Metro Vancouver. Call (604) 473-9690.
Which parts wear out on a Lochinvar Knight boiler?
The Knight is a condensing, sealed-combustion gas boiler. A variable-speed blower draws in outdoor air and premixes it with gas, the burner fires into the heat exchanger (stainless steel on the Knight units we typically see), and the control modulates the flame to match the heating load. That design is efficient, but it depends on several small, precise parts agreeing with each other every time the boiler fires. When one of them drifts or fails, the control locks the burner out instead of letting it run unsafely.
The table below lists the components that most often bring a Knight in for service, what each one does, what the owner usually notices, and whether the replacement needs to be a brand-matched part. Exact components vary by model and generation, so treat this as a guide rather than a parts list for your specific unit.
| Component | What it does | What the owner usually notices | Brand-matched part? |
|---|---|---|---|
| Igniter | Lights the gas and air mixture at the start of each firing cycle | The boiler tries to start, clicks or hums, then locks out with no flame | Yes |
| Flame sensor | Proves to the control that a stable flame is present | The burner lights briefly, shuts off, and repeats several times before locking out | Yes |
| Gas valve | Meters gas to the burner under the control board’s direction | No ignition despite a working igniter, rough starts, or a gas smell near the boiler (leave and call from outside) | Yes, and licensed gas work only |
| Combustion blower | Moves combustion air in and flue gas out through the sealed system | Whining, grinding or roaring at start-up, or lockouts before the burner ever lights | Yes |
| Circulator pump | Pushes heated water through the boiler loop and out to the house | The boiler fires but rooms stay cold, the pump hums without moving water, or kettling noises | Matched by specification; often not a boiler-brand part |
| Water pressure sensor | Confirms the system has enough water pressure to fire safely | The boiler will not fire and the gauge reads low, or the gauge looks normal but the control still reports a pressure problem | Yes |
| Control board | Runs the ignition sequence, safeties, modulation and pump outputs | A blank or frozen display, erratic behaviour, or pumps running when they should not | Yes, and it must suit the unit’s generation |
| Condensate trap | Drains acidic condensate while keeping flue gas out of the room | Water on the floor under the boiler, gurgling, or shutdowns linked to condensate backing up | Trap yes; drain line and neutralizer by specification |
What does a failing Knight part look like from the homeowner’s side?
Owners rarely see the failed part itself. They see what the boiler does. These are the patterns we hear about most often on service calls for this family, and what they usually point toward.
- It tries to start, stops, and tries again: often ignition or flame sensing, but a partly blocked condensate trap or vent can produce the same pattern.
- The display shows a lockout message: write down the exact wording before anything is reset. Do not look up a message online and order a part from it; the same message can have several causes.
- The boiler runs but the house stays cold: commonly a circulator, a zone valve, air in the system or a control setting rather than a burner part.
- The pressure gauge keeps dropping: water is leaving the system through a leak, the relief valve or a failed expansion tank. The pressure sensor stopping the boiler is doing its job.
- Water under the boiler: the condensate trap, the drain line, a relief valve discharge or a leaking fitting, each with a different fix.
- New noises: whining or grinding from the blower, a gravelly or kettling sound from the heat exchanger, or a pump that hums loudly.
- Space heating works but the indirect hot water tank stays cool: often a priority setting, a tank sensor, or the tank-side pump or valve.
Does a Knight replacement part have to be a genuine Lochinvar part?
For anything that touches combustion or safety, yes. The igniter, flame sensor, gas valve, blower, burner, gaskets, sensors and control board were designed and tested together as part of the boiler’s certification, and the installation manual calls for the manufacturer’s replacement parts. A universal igniter or a lookalike blower may physically fit, but it can change how the burner lights or how much air moves through it, which affects combustion quality and can raise carbon monoxide. We do not install substitutes on the combustion side of a Knight.
The control board has an extra wrinkle. The Knight family has been revised over the years, and boards and their software are matched to specific models and generations. A board from a different revision may not communicate properly with the display, sensors or blower. Matching it from the rating-plate information rather than from the appearance of the old board avoids that problem.
Other parts of a Knight installation are standard hydronic components matched by specification, not by boiler brand. Circulator pumps, the expansion tank, zone valves, air and dirt separators, the system pressure relief valve and the condensate neutralizer are chosen by size, pressure rating and fit with the system design. Here the correct part is the one that suits your piping and heat load, and a same-brand swap is not required.
How does an independent contractor source the right part for a Knight?
The starting point is always the rating plate on the boiler, which lists the model and serial number. The serial matters because it tells the parts supplier which generation of the family your unit belongs to, and some parts changed between generations. We photograph the plate, the failed part and its connections before anything is removed.
BC Wide is an independent contractor, not a Lochinvar dealer or warranty centre. We source replacement parts through the wholesale supply channels that carry the brand, matched to your model and serial, and we check the part against the manufacturer’s published parts information before it goes in. We do not promise stock or delivery times on a page like this because availability changes; we tell you what we find when we order.
If your boiler may still be under manufacturer coverage, find the paperwork from the original installation before work starts. Warranty claims run under the manufacturer’s own terms, and we can document what we find so you can pursue that route if it applies.
The job does not end when the part is swapped. Depending on the component, the technician checks gas pressure, verifies the flame signal, confirms combustion with an analyzer, tests the safeties and watches the boiler through several complete cycles before leaving.
How are Knight boilers usually set up in Metro Vancouver homes?
Most Knight boilers we see in Metro Vancouver heat homes through radiant floors, panel radiators or fin-tube radiation, and many also heat domestic hot water through an indirect tank. Depending on the model, they are wall-hung in a mechanical closet, garage or basement, or floor-standing in a larger mechanical room. Piping is typically primary-secondary or uses a hydraulic separator, with a boiler pump, one or more system or zone pumps, and an outdoor sensor so the water temperature follows the weather.
Our mild, wet coastal climate suits a condensing boiler, because long shoulder seasons keep return water cool, which is when condensing boilers work best. It also means the boiler spends a lot of time at low load. If the boiler is oversized or the controls are poorly set up, it short cycles, and every extra start is wear on the igniter, flame sensor, blower and relays.
Metro Vancouver water is soft, so scale is rarely the story on the heating side. The problems here are sludge and corrosion: iron oxide from older steel piping and radiators, especially where a Knight replaced an older boiler on original pipework without a thorough flush. Sludge settles in the heat exchanger, fouls sensors and wears out circulators. A dirt separator and a properly maintained inhibitor are modest additions compared with the parts they protect.
Venting is the other local factor. In townhouses and strata homes, Knight boilers are often vented through a sidewall close to neighbours, decks and walkways. Leaves, bird nests, landscaping and the occasional cold snap can block intakes and cause lockouts that look like part failures. If a repair involves changing vent routing on a strata property, check your bylaws with council first; gas and venting work in BC is permitted and carried out by a licensed contractor.
What can I safely check before calling for service?
A few checks are safe for any homeowner and occasionally solve the problem without a service call.
- The thermostat is set to heat, the setpoint is above room temperature, and its batteries are fresh if it uses them.
- The boiler’s service switch, usually a light-style switch near the unit, is on.
- The breaker for the boiler has not tripped. If it trips again after being reset, leave it off and call.
- The pressure gauge reads within the normal range printed on the boiler or system label. If it is low, note the reading for the technician.
- A boiler has no air filter to change, but from outside you can look at the vent and intake terminals for obvious blockages such as leaves or a cover, without touching or removing anything.
- Any message on the display is written down exactly as shown.
When is one failed part a reason to assess the whole boiler?
One failed part on an otherwise healthy Knight is usually a straightforward repair. Igniters and flame sensors are wear items, and a circulator reaching the end of its life is normal. The picture changes when the failure is a symptom of something bigger.
- The same part has failed more than once, pointing to a root cause such as sludge, short cycling, a venting fault or a condensate problem.
- The heat exchanger shows fouling, leakage or corrosion; it is the core of the boiler and the most serious repair.
- Several expensive parts are failing together, such as the control board and blower on an older unit.
- Parts for your generation have been superseded or are becoming harder to source.
- A renovation changed the heat load, the boiler was sized for a different house, or it short cycles constantly.
- The piping, expansion tank, venting or condensate disposal no longer meets current requirements.
How do you decide between repairing and replacing a Knight boiler?
What decides it is the condition of the heat exchanger, the age and service history of the boiler, how the rest of the system is holding up, and whether the new part fixes the cause or only the symptom. A control board is one of the more expensive parts on a boiler like this, so on an older unit with a tired heat exchanger it is worth weighing the whole picture before ordering one.
We explain what we found in plain language, give you a written quote for the repair and, where it genuinely makes sense, a separate written quote for replacement. No work starts until you have approved it, and a repair is never framed as a stepping stone to a sale.
When should I call a licensed technician?
Replacing any Knight component beyond the owner checks above is technician work. Gas valve, igniter, flame sensor, burner and blower work involves the gas train and sealed combustion system, which in BC is restricted to licensed gas fitters. Control boards, pumps and sensors involve line-voltage wiring that also belongs to a qualified trade. Draining, refilling and purging the system, replacing a relief valve or expansion tank, or flushing out sludge should be done by someone who can recommission the system properly.
Do not open the sealed combustion cover, remove panels to look at the burner, bypass a switch or sensor, or reset a lockout over and over. A lockout is the boiler protecting you, and repeated resets can hide a venting or combustion problem.
Call right away, and do not run the boiler, if you smell gas (leave the home first), a CO alarm sounds, you see soot or scorching, or water is spraying. Call soon if the boiler locks out after your checks, pressure keeps dropping, water is pooling, or it is making new noises. BC Wide Home Services has worked on Metro Vancouver heating systems since 1999 under licences LGA0090068 and CGA0028029. We offer same-day service where we can, especially for no-heat calls in cold weather, but we never guarantee an arrival window. Call (604) 473-9690.
Frequently asked questions
Can I replace the igniter or flame sensor on my Lochinvar Knight myself?
No. Both sit inside the sealed combustion system, and working there in BC is restricted to licensed gas fitters. After replacement the technician also has to verify the flame signal and combustion, which needs proper instruments.
Do I need a genuine Lochinvar part, or will a universal part do?
For combustion and control parts such as the igniter, flame sensor, gas valve, blower and control board, use the manufacturer’s part matched to your model and serial. Circulators, expansion tanks and relief valves are standard hydronic components matched by specification, so they do not need to carry the boiler’s brand.
Where do I find the model and serial number on my Knight boiler?
They are on the rating plate, a label on the boiler cabinet. Take a clear photo and have it ready when you call. If the plate cannot be seen without removing a panel, leave it for the technician.
Why does my Knight boiler keep losing pressure?
Water is leaving the system somewhere, usually through a small leak, a relief valve that is discharging, or an expansion tank that has lost its air charge. The pressure sensor shutting the boiler down is a symptom, not the cause. A technician should find the leak before the sensor is blamed or the system is refilled repeatedly.
Is BC Wide a Lochinvar dealer or warranty centre?
No. BC Wide is an independent TSBC-licensed contractor that services and installs the Knight family. We source brand-matched parts through wholesale supply channels, and warranty claims run under the manufacturer’s own terms.
How quickly can a failed part be replaced?
It depends on the diagnosis and on part availability, which changes, so we confirm timing when we order rather than promising it in advance. Once the correct part is on hand, most single-component repairs are completed and tested in one visit. We offer same-day service where we can but never guarantee an arrival window.
Is it worth repairing an older Knight boiler?
Often yes, if the heat exchanger is sound and the failure is a wear item. If parts keep failing, the heat exchanger is fouled or leaking, or several costly parts are going at once, it makes sense to assess the whole boiler first. We give written quotes for both options so you can decide.
BC Wide Home Services — Lower Mainland home-comfort specialists since 1999
Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians · Evening and weekend calls · Diagnostic service calls $189.00 · Free in-home estimates on replacements (the $189.00 is waived if you replace with us). Call 604-473-9690 or book a free replacement estimate.
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.