★ 4.7 Google rating · Serving Greater Vancouver since 1999
ServicesBrandsRebates ReviewsAboutContact 📞 Call (604) 473-9690

Lochinvar Knight Boiler Repair

Boilers

Lochinvar Knight Boiler Repair
Home › Lochinvar Knight Boiler Repair

Lochinvar Knight Boiler Repair

Key takeaways

  • Most Lochinvar Knight service calls in Lower Mainland homes trace back to ignition lockouts, a blocked condensate trap, low system pressure, circulator or zone problems, or sludge from an older hydronic system.
  • Owner-safe checks are limited to the thermostat, the boiler service switch, the breaker and the pressure gauge compared against the normal range printed on the boiler label.
  • Do not keep resetting a Knight that has locked out; write down exactly what the display shows and call a TSBC-licensed gas technician.
  • The model and serial number from the rating plate tell the technician which generation and control you have, which decides the correct parts and procedures.
  • Repair usually makes sense until the heat exchanger itself is compromised, parts become hard to source, or the same fault keeps returning because the system around the boiler is the real problem.
  • BC Wide services the Knight family as an independent TSBC-licensed contractor, not as a factory-authorized dealer or warranty centre.

If your Lochinvar Knight boiler has stopped heating, is losing pressure, keeps locking out or is cycling on and off, the problem is usually one of a small group of faults: failed ignition, a blocked condensate drain, low water pressure in the heating loop, a circulator or zone valve that has stopped moving water, or sludge restricting flow through the heat exchanger. You can safely check the thermostat, the boiler switch, the breaker and the pressure gauge, and that is where owner work stops. Anything involving the burner, gas valve, venting, controls or the pressurized hydronic piping needs a TSBC-licensed gas technician. BC Wide Home Services has repaired hydronic systems across Metro Vancouver since 1999 and services the Knight family as an independent contractor. Call (604) 473-9690 and have the model and serial number from the rating plate ready.

What usually goes wrong with a Lochinvar Knight boiler?

The Knight is a gas-fired, condensing, modulating boiler with a sealed combustion chamber. It draws combustion air through one pipe and sends exhaust out through another, and it deliberately cools its own exhaust enough to condense water out of it. That design is what makes a condensing boiler efficient, and it is also what shapes the faults we see. A condensing boiler produces acidic condensate every hour it runs, it depends on clean air and vent piping, and it relies on a steady flow of water through a compact heat exchanger.

In owner language, the calls we get for this family sound like this: the house is cold and the boiler screen shows a lockout; the boiler lights, runs briefly and shuts off, over and over; there is water on the floor under the boiler; the pressure gauge keeps dropping and someone keeps topping it up; the radiators or in-floor zones are warm in one area and cold in another; or the indirect hot water tank has gone lukewarm. The table below matches those behaviours to the causes we most often find. It is a starting point for a conversation with your technician, not a diagnosis.

What you noticeCommon causes we findWho should handle it
Boiler tries to light, then locks outWorn or dirty igniter or flame sensor, gas supply issue, blocked air intake or vent, condensate backing up into the combustion areaLicensed gas technician
Short cycling: on and off every few minutesBoiler oversized for the load, poorly set outdoor reset or modulation, a single small zone calling alone, flow restrictionLicensed gas technician
Water pooling under the boilerBlocked or cracked condensate trap or line, relief valve discharging, leaking fitting or pump flangeOwner reports it; technician repairs
Pressure gauge keeps fallingSlow leak in piping or a radiator, waterlogged expansion tank, relief valve weepingOwner reads the gauge; technician finds the leak
Some zones warm, others coldFailed zone valve or zone circulator, air trapped in a loop, thermostat wiring or zone control faultLicensed technician
Gurgling or rushing water noisesAir in the system, low pressure, a circulator running without enough waterLicensed technician
Indirect hot water tank no longer hotDomestic hot water priority setting, tank sensor or aquastat, circulator or diverting valve faultLicensed technician
Burner runs but the house stays coolSludge or magnetite restricting the heat exchanger, circulator not moving water, outdoor sensor reading wrongLicensed technician

How is a Knight boiler usually set up in Lower Mainland homes?

Knight boilers come in wall-hung and floor-standing versions, and in Metro Vancouver we see both. The wall-hung version is common in townhouses, laneway homes and basement mechanical rooms where floor space is tight. Floor-standing versions tend to show up in larger detached homes in Burnaby, Vancouver, North Vancouver and Coquitlam with a long list of zones.

The typical installation here is one of three patterns. The first is a retrofit into an older home that originally had a cast-iron boiler feeding cast-iron radiators or baseboard convectors; the Knight replaced the old boiler, but the original piping and radiators stayed. The second is hydronic in-floor radiant heat in a newer build or a major renovation, often with a mixing arrangement because in-floor loops want cooler water than a radiator does. The third combines either of those with an indirect hot water tank, so the same boiler heats the house and the domestic hot water.

Almost every Knight we service is piped primary-secondary, through closely spaced tees or a hydraulic separator, so the boiler has its own circulator and the heating zones have theirs. Most are set up with an outdoor air sensor so the boiler lowers its water temperature on mild days. The vent and air intake usually run through a side wall, which on tight Lower Mainland lots can put the termination close to a fence, a neighbour’s window or a walkway. Every one of these details matters during a repair, because a fault that looks like a boiler problem is often a piping, zoning or venting problem around it.

What can I safely check before I call?

A few checks are safe for any homeowner and can save you a service visit. They do not involve opening the boiler cabinet, touching the burner area, or changing any settings in the boiler control. A Knight has no furnace filter to change, so the checks below replace that step.

  • Thermostat: confirm it is set to heat, the set temperature is above the room temperature, and the batteries are fresh if it uses them. If you have several zones, check the thermostat for the cold zone specifically.
  • Boiler service switch: there is usually a light-style switch on the wall or on the boiler circuit near the unit. Make sure it is on; it is easy to bump off during cleaning or storage.
  • Breaker: check the panel for a tripped breaker labelled for the boiler or the heating system. If it trips again after one reset, leave it off and call.
  • Pressure gauge: read the gauge on the boiler or nearby piping and compare it with the normal operating range printed on the boiler label or in your owner documentation. Note the reading when the system is cold and again when it is hot.
  • Display message: write down exactly what the boiler screen says, or take a photo of it. That record is far more useful to a technician than a guess at what it means.
  • Water: look for water under the boiler or around the condensate line and note where it seems to come from. Do not remove covers to trace it.

What should I never do to a Knight boiler myself?

Some well-meant fixes cause more damage than the original fault. Do not reset a lockout over and over. A lockout is the control telling you something is unsafe or not working; forcing repeated ignition attempts can flood the combustion area with unburned gas, stress the igniter and hide the evidence a technician needs.

Do not open the sealed combustion chamber, remove the burner door, try to relight anything, jumper or bypass any switch or sensor, or change settings in the installer menu. Do not keep adding water to the system to fix a falling pressure gauge; a boiler that needs regular topping up has a leak or a failed expansion tank, and fresh water brings in oxygen that accelerates corrosion inside the system. Gas work and most electrical work on a boiler is legally restricted to licensed trades in British Columbia, and a Knight has both.

If the house is getting cold while you wait for service, close off rooms you are not using and add layers. Never use a gas oven, stove, barbecue or patio heater indoors for warmth.

Why do you need the model and serial number from the rating plate?

The Knight name has covered several generations of boilers, and the control boards, igniters, flame sensors, blowers, gas valves and display modules are not interchangeable across all of them. The model number tells us which version and size you have, and the serial number tells us roughly when it was built. Together they decide which parts fit, which installation and service manual applies, and which procedures the manufacturer publishes for that exact unit.

The rating plate is a label on the boiler, usually on the side or inside the front of the jacket; on a wall-hung unit it may be visible without opening anything. Please photograph the label rather than removing covers to find it. If you cannot reach it safely, tell us when you call and we will read it on arrival. Capacities, efficiency ratings, clearances and vent limits for your boiler are manufacturer-published; check the rating plate and the installation manual for your exact unit rather than relying on figures from another model.

Having this information when you book lets us check part availability before we arrive, which is the single biggest factor in whether a repair can be finished on the first visit.

How do you diagnose a Knight boiler on the first visit?

We start with the history: what the boiler was doing, when it started, what the display showed, whether anyone has reset it or added water, and when it was last serviced. The Knight control keeps a record of recent lockouts and operating information, and we read that stored history before touching anything, because it often shows a pattern the current message does not.

Next we look at the system as a whole. We check the static and operating pressure, the expansion tank charge, the condensate trap and drain line, the air intake and vent termination outside, and whether each circulator and zone valve is actually moving water. We look at how the outdoor sensor and heating curve are set, since a poorly set curve is a common reason for short cycling in our mild climate.

Then we work on the appliance. With the boiler running, we measure gas pressure, watch the ignition sequence and flame signal, and use a combustion analyser on the flue gas. Where the history or symptoms point to it, we inspect the igniter, flame sensor, burner and heat exchanger passages. If sludge is suspected, we check the condition of the system water and whether any inhibitor or filtration is in place.

At the end of the visit you get a plain explanation of what we found, what we fixed, and what is still recommended, with a written quote for anything beyond the visit. We aim to fix the cause, not just clear the fault so it comes back next week.

Why do Metro Vancouver homes see particular Knight problems?

Metro Vancouver tap water is soft, so the hydronic trouble we find is rarely limescale. It is corrosion and sludge. Many Knight boilers here were installed into older systems with decades of iron oxide and debris in the radiators and piping. When that dark, magnetic sludge circulates into a compact modern heat exchanger, it restricts flow, creates hot spots and can lead to overheating lockouts. That is why a retrofit without proper system flushing, a dirt or magnetic separator and correct water treatment is one of the most common root causes we uncover.

Our mild, wet coastal climate means long heating seasons at low output. A boiler that is oversized for the house, or set with an aggressive heating curve, spends much of the year cycling on and off rather than running long and gently. Short cycling wears ignition parts and wastes the efficiency the boiler was bought for. Heavy rain and moss also matter: condensate lines routed outside or to an overloaded drain, and vent terminations near shrubs or under decks, can be affected by debris and weather.

Density is the other factor. In townhouses and strata buildings the boiler, vent and condensate route are often constrained, and access can be tight. We do not advise on what a strata corporation or a heritage designation allows; owners should confirm bylaws with their strata council, and heritage questions go to the municipality. Any gas work we carry out is done under the appropriate permit through Technical Safety BC.

When should I call a licensed technician right away?

Call a licensed technician as soon as the owner-safe checks do not solve the problem, and immediately in any of the situations below. Where we can, we offer same-day service in Metro Vancouver, but availability depends on the day’s schedule and parts, and we will not promise an arrival window we cannot keep.

  • You smell gas anywhere near the boiler or the house: leave, then call your gas utility’s emergency line or 911 from outside.
  • A carbon monoxide alarm sounds, or anyone feels headache, dizziness or nausea at home.
  • The boiler locks out again after one reset, or shows the same message repeatedly.
  • Water is leaking from the boiler, the relief valve is discharging, or the pressure gauge is outside the range printed on the label.
  • You see scorching, soot, melted wiring, or hear loud banging or kettling from the boiler.
  • The vent or air intake pipe outside is damaged, disconnected or blocked by something you cannot safely clear from the ground.

When does repair stop making sense on a Knight boiler?

Most Knight faults are repairable: igniters, flame sensors, condensate traps, circulators, zone valves, sensors and expansion tanks are routine replacements. A control board or gas valve is among the more expensive repairs on this family, but on a boiler in otherwise good condition it is still usually worth doing.

Repair stops making sense when the heat exchanger itself is leaking, cracked or badly fouled beyond cleaning, because that is the heart of the appliance. It also stops making sense when the boiler is old enough that key parts are discontinued or hard to source, when several major components are failing at once, or when the same fault keeps returning because the boiler was undersized, oversized or piped into a system it does not suit. In that last case, replacing the boiler without fixing the system repeats the problem.

We look at the age from the serial number, the condition of the heat exchanger, the state of the system water, the service history and parts availability, and then give you both options in writing. Before any work starts, you get a written quote. If replacement is the right call, we explain the choices and the permit and venting requirements for your home, and the decision stays yours.

Gas & carbon-monoxide safety: Your Lochinvar Knight burns natural gas, so gas and carbon monoxide safety come first. Install CO alarms on every level of the home and near sleeping areas, and test them regularly. If you smell gas, do not operate switches, phones or appliances inside; leave the house and call your gas utility’s emergency line or 911 from outside. If a CO alarm sounds or anyone feels unwell, get everyone outside and call for help. Keep the outdoor vent and air intake clear of snow, leaves, stored items and plantings. Gas work and most electrical work on a boiler is legally restricted to licensed trades in BC; homeowners should limit themselves to the thermostat, service switch, breaker and reading the pressure gauge. BC Wide Home Services Ltd is TSBC-licensed (LGA0090068, CGA0028029). Call (604) 473-9690.

Frequently asked questions

Is BC Wide a Lochinvar dealer or warranty centre?

No. BC Wide is an independent TSBC-licensed contractor that services and installs the Knight family, among other brands we service. We are not a factory-authorized dealer or warranty centre. If your boiler may still be under manufacturer warranty, check your paperwork and the manufacturer’s process before booking repairs.

Why does my Knight boiler keep locking out?

Repeated lockouts usually mean the boiler cannot prove a safe, stable flame or is detecting a safety condition. Common causes are a worn igniter or flame sensor, a blocked condensate trap, a restricted vent or air intake, a gas supply problem, or poor water flow. Write down what the display shows, stop resetting it, and call a licensed technician.

My boiler pressure keeps dropping. Can I just top it up?

Topping it up hides the problem and adds fresh, oxygen-rich water that speeds corrosion inside the system. A pressure drop means there is a leak somewhere, a waterlogged expansion tank or a relief valve that is discharging. Note the reading against the range on the boiler label and have a technician find the cause.

Can you tell me what my Knight’s error message means over the phone?

We can talk through what you are seeing, but we will not guess at a fault code without seeing the boiler. The meaning depends on the generation and control version, which is why we ask for the model and serial number. The stored lockout history on the unit usually tells us more than a single message.

Why is there water under my Knight boiler?

The most common source is the condensate system: a clogged trap, a disconnected or cracked drain line, or a condensate pump that has failed. Other sources include a discharging relief valve or a leaking pump flange or fitting. Keep the area dry, note where the water seems to come from, and call rather than removing covers.

Do you offer same-day Knight boiler repair?

Same-day service is available where our schedule and parts allow across Metro Vancouver, and no-heat calls get priority. Having the model and serial number ready lets us check parts before arriving, which improves the chance of a first-visit fix. We will give you an honest arrival estimate rather than a guaranteed window.

Is it worth repairing an older Knight boiler?

Often yes, if the heat exchanger is sound and parts are available. Replacement starts to make more sense when the heat exchanger is leaking or badly fouled, several major parts are failing together, or parts are discontinued. We give you a written quote for both options so you can compare before deciding.

BC Wide Home Services — Lower Mainland home-comfort specialists since 1999

Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians · Evening and weekend calls · Diagnostic service calls $189.00 · Free in-home estimates on replacements (the $189.00 is waived if you replace with us). Call 604-473-9690 or book a free replacement estimate.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a boiler be serviced?
Annual servicing is recommended for all residential boilers. BC Wide's annual service includes combustion analysis, heat exchanger inspection, expansion tank pressure check, condensate trap cleaning, and a full safety check. Annual maintenance is also required to keep most manufacturer warranties valid.
How much does a new boiler cost in Vancouver?
A typical residential high-efficiency gas boiler in Metro Vancouver costs $7,500–$15,000 installed, depending on size, brand, and whether the system is heating only or a combi unit that also handles hot water. BC Wide provides a free written quote with three options at different price points.
How long does a boiler last?
A well-maintained cast-iron boiler can last 25–30 years, a modern high-efficiency condensing boiler typically lasts 15–20 years, and a combi boiler 12–18 years. Annual servicing has the single biggest impact on lifespan.
My boiler is making a banging or kettling noise. Is that dangerous?
Kettling (a banging or whistling sound) is usually caused by limescale build-up on the heat exchanger and is a sign the system is overheating in localised spots. It will not always cause immediate failure but it shortens the life of the boiler and should be addressed within a few weeks.
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Yes. BC Wide is one of the few HVAC companies in the Lower Mainland with deep experience on European and high-end North American boilers including Viessmann, IBC, Baxi, Laars, Weil-McLain, NTI, Navien and Rinnai. We carry common parts in the truck.
Should I repair or replace my old boiler?
A useful rule: if the boiler is more than 15 years old and the repair cost is more than 50% of replacement, replacement is the better investment. BC Wide will give you both a repair quote and a replacement quote and let you decide.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote