Six flashes on a Luxaire furnace means the burners lit and the control proved flame, then lost it, often more than once in the same heating cycle (confirm against the manual for your unit). The furnace short-cycles or locks out and the house cools down. Check power, the thermostat, the gas shutoff handle, the filter and the outside vent pipes, and reset once only if your manual allows it. If the code returns, book a licensed gas technician at (604) 473-9690.
If your Luxaire furnace is showing 6 flashes (Flame loss / repeated flame dropout), here’s exactly what it means and what to do. This guide is part of our full Luxaire furnace error code list.
Severity: Needs attention.
What 6 flashes means on a Luxaire furnace
Flame was established but then lost, often repeatedly, during a heating cycle.
Common causes
- Weak flame sensing (dirty/positioned flame sensor)
- Marginal gas supply or pressure
- Burner or orifice fouling
- Condensate or venting issue disturbing the flame
- Flame rollout or pressure-switch interaction
What you can safely check first
- Replace a dirty air filter
- Outside, confirm the vent/intake terminations are clear
- Do not attempt burner, gas, or flame-sensor service — call a professional
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Luxaire furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Luxaire furnace repair across Greater Vancouver
If a Luxaire furnace showing 6 flashes won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Luxaire furnace codes
- Luxaire furnace Steady ON — Normal operation
- Luxaire furnace LED OFF — No power to control / control failure
- Luxaire furnace Rapid continuous flash — Line-voltage polarity reversed / grounding issue
- Luxaire furnace 2 flashes — External lockout (retries exhausted)
- Luxaire furnace 3 flashes — Pressure switch / draft fault
- Luxaire furnace 4 flashes — High-limit / temperature limit open
Frequently asked questions
Is 6 flashes on a Luxaire furnace serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Luxaire furnaces 7 days a week across Greater Vancouver.
How do I reset a Luxaire furnace after 6 flashes?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Luxaire furnace error code 6 flashes: what it means for your home
In plain terms, the code tells you the furnace is trying to heat and failing partway through. The start-up sequence ran normally: the inducer fan started, the pressure switch closed, the igniter came on, the gas valve opened and the burners lit. The control board then watches the flame through the flame sensor for as long as the thermostat calls for heat. When that signal drops out, the board closes the gas valve as a safety measure, waits, and tries again. Six flashes is the board reporting that this has been happening during heating cycles, which matches the meaning at the top of this page: flame established, then lost, often repeatedly. Confirm the meaning against the manual or the code chart printed on the furnace door for your unit, because Luxaire control boards have changed over the years.
For you, it shows up as heat that comes and goes, rooms that never reach the set temperature, and a furnace that may eventually stop trying altogether. It does not mean the furnace is about to fail dangerously in the next minute, but it does mean a safety system is doing its job and something in the burner, gas supply, venting or flame-sensing circuit is not right. Your gas water heater is a separate appliance and usually keeps working. If it also misbehaves at the same time, mention that when you book, because two gas appliances struggling together can point to a gas supply problem rather than a furnace fault.
What owners usually tell us when they call about this code:
- The furnace lights, runs for a short while, then the burners go out and it starts over.
- The blower keeps running and blows cool air after the flames go out.
- The house drifts below the thermostat setting, especially overnight.
- It works for a day after someone switched the power off and on, then the flashing comes back.
- It seems worse on windy or very wet days.
- The igniter clicks or glows far more often than it used to.
- In the end the furnace stops completely and the status light keeps blinking the same pattern.
Luxaire furnace error code 6 flashes: what we check first, most common cause first
These are the causes we find behind repeated flame loss on gas furnaces in Greater Vancouver, roughly in the order we see them. The list follows the causes named at the top of this page. The table shows what you might notice, the one thing you can safely look at yourself, and the point where it becomes a job for a licensed gas technician.
Two things make this code harder than it looks. First, causes stack: a slightly weak flame signal might hold on a calm day and drop out when wind changes the pressure at the vent terminal and the flame shifts a little. Second, the board only reports that flame was lost, not why. A correct diagnosis means measuring each link in the chain rather than swapping the easiest part and hoping. A flame sensor that gets cleaned without anyone finding out why it lost signal, or a sensor replaced when the real problem is gas pressure, is the most common reason we see this code return a few weeks after an earlier visit.
| Likely cause (most common first) | What you may notice | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Weak flame sensing: a dirty, coated or out-of-position flame sensor, or a poor ground path | Burners light normally, then go out after a short time and the cycle repeats | Nothing inside the furnace. Make sure the filter is clean and the front door is fully seated | Always. Cleaning, repositioning or testing the sensor and its ground means opening the burner area |
| 2. Marginal gas supply or pressure | Flames look small or lazy; the problem is worse when other gas appliances are running | Confirm the furnace gas shutoff handle is in line with the pipe and that your other gas appliances work | Always. Measuring inlet and manifold gas pressure is licensed gas work |
| 3. Burner or orifice fouling | Uneven flames, yellow tips, a rumble on light-off, or soot | Look through the sight window if your furnace has one; do not open anything | Always. Burner and orifice service is licensed gas work |
| 4. Condensate or venting issue disturbing the flame | Gurgling, water near the furnace, a fault that is worse on windy or rainy days | Clear leaves, snow or nests from the outside intake and exhaust pipes; look for kinked or sagging drain tubing | When the pipes are clear and the drain looks normal, or if water is leaking from the cabinet |
| 5. Flame rollout or pressure-switch interaction | Scorch marks near the burner opening, a hot or burning smell, or a furnace that will not restart | Turn the furnace off at the thermostat and do not reset it | Immediately. Rollout can point to a blocked flue or heat exchanger and is a safety fault |
Can I reset a Luxaire furnace flashing 6 times? The owner-safe steps, in order
Yes, once, if the owner’s manual for your model allows a reset, and only after you have worked through the basic checks below. A reset clears the lockout so the furnace will try again. It does not fix anything. Resetting over and over hides the pattern a technician needs to see and keeps sending gas to a burner that is not holding flame properly.
What you should not do: remove the burner compartment door, sand or bend the flame sensor, adjust the gas valve, jumper or bypass any switch, or reset a rollout switch. All of that is licensed gas work in BC, and several of those shortcuts are how a flame-loss fault turns into a carbon monoxide or fire problem. Every home with a gas furnace should have working carbon monoxide alarms near the furnace and on each sleeping level, and this is a good moment to test them.
- Step 1, safety first: if you smell gas (a rotten-egg odour) or a carbon monoxide alarm is sounding, stop. Leave the house, then call FortisBC or 911 from outside. Do not touch switches and do not try a reset.
- Step 2, record the code: count the flashes through the sight window before you touch the power, because switching the furnace off usually clears the light. Note the time and what the furnace was doing.
- Step 3, thermostat: check it is set to heat, set above room temperature, and has fresh batteries if it uses them.
- Step 4, power: check the furnace service switch (it looks like a light switch near the furnace) is on and the breaker has not tripped. If a breaker trips again after one reset, leave it off and call.
- Step 5, gas shutoff: the handle on the gas pipe beside the furnace should sit in line with the pipe, which means open. If someone closed it, that may be your answer. If you are unsure, leave it alone and call.
- Step 6, filter: a badly clogged filter cuts airflow, overheats the heat exchanger and can upset combustion. Replace it if it is dirty.
- Step 7, outside pipes: on a high-efficiency furnace there are usually two plastic pipes outside, one for intake and one for exhaust. Clear leaves, snow, ice, cobwebs or a nest by hand. Never push anything into the pipes.
- Step 8, visible condensate tubing: if it is kinked, disconnected or sitting in water, note it for the technician. Do not cut, open or disconnect any drain fittings inside the cabinet.
- Step 9, one reset: reset once, the way your manual describes, and watch a full heating cycle. If the burners go out again or the code returns, set the thermostat to off and book a licensed technician.
How our Luxaire furnace repair visit works, step by step
When you call (604) 473-9690 about a Luxaire furnace flashing 6 times, we ask for the flash count, roughly how old the furnace is if you know, whether it has plastic vent pipes, and what you have already checked. We book same-day where we can. In a cold snap the schedule fills quickly, and we will tell you honestly what the earliest realistic slot is rather than promise an arrival window. Diagnostic service calls are $189.00.
The parts most often involved in a repeated flame-loss fault, in general terms, are the flame sensor and its wiring and ground connection, burners and orifices that need cleaning, pressure switch hoses, condensate traps and drains, and less often the gas valve or the control board. A control board is one of the more expensive parts on a gas furnace, which is why we prove it is at fault before we quote it. We do not price parts or labour over the phone, because the right repair depends on what the meters show.
BC Wide Home Services Ltd is an independent, Technical Safety BC-licensed gas contractor (licence LGA0090068, Class B gas licence CGA0028029), serving Metro Vancouver since 1999. The work is done by our own licensed gas fitters. We service Luxaire furnaces as an independent contractor, not as a factory-authorized dealer or warranty centre. Where a repair or a replacement needs a gas permit, we take it out and arrange the inspection, and you get the paperwork.
- Arrival safety check: the technician checks for gas odour and measures carbon monoxide around the furnace and in the room before starting.
- Fault history: we confirm the flash code and, where the control stores past faults, read the history so we know how often flame has been lost.
- Flame signal: with a meter in the flame sensor circuit, we measure the flame-rectification signal while the burners run and compare it with what the manufacturer documents for your control.
- Gas pressure: with a manometer we check inlet pressure with your other gas appliances running, then manifold pressure at the valve, against the furnace rating plate.
- Burners and flame pattern: we inspect for rust flakes, debris, misalignment, and flames that lift, waver or roll toward the sensor.
- Venting and condensate: we check the vent run, terminals, trap and drain, plus the pressure switch hoses and readings, because a borderline pressure switch can interrupt a cycle in a way that looks like flame loss.
- Safety tests: high limit, rollout switches, pressure switch and flame proving are each tested, not assumed.
- Written quote before any work beyond diagnosis: you get the cause, the fix and the price in writing, and you decide. Nothing beyond the diagnosis happens without your approval.
- Repair, retest and record: after the repair we run several full heating cycles, re-measure flame signal and combustion, and leave a written record of what we found and what we changed.
Should I repair or replace an older Luxaire furnace that keeps losing flame?
Most flame-loss faults are repairs, not replacements. A cleaned and properly grounded flame sensor, corrected gas pressure, or a cleared condensate trap can put an older furnace back into reliable service. Replacement becomes a fair question when the diagnosis turns up something bigger, or when the furnace is near the end of its working life and this repair is one of several in recent seasons. We will tell you which side of that line your furnace is on, and why, in writing.
Signs that replacement deserves a serious look:
If replacement is on the table, our in-home estimate for replacing or installing equipment is free and comes as a written quote. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived (taken off the installation). Many Metro Vancouver owners use the moment to look at dual fuel: a heat pump that carries most of our mild, damp heating season, paired with a new gas furnace kept as backup for cold snaps. We size that from a room-by-room load calculation and a look at your ductwork, not from the old furnace’s rating plate, and we never push a replacement when a repair is the honest answer.
- Flame rollout or scorching that points to a cracked or blocked heat exchanger.
- Corrosion inside the cabinet, at vent connections or around the secondary heat exchanger from years of condensate.
- A control board or gas valve failure on a furnace that is already well past middle age.
- Repeated service calls for different faults over the last few heating seasons.
- Rooms that have always been uncomfortable, which suggests the furnace or the ductwork was never sized correctly in the first place.
Luxaire furnace error code 6 flashes repair near you in Greater Vancouver
We diagnose flame-loss faults on Luxaire furnaces across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock across the region varies a lot, and it changes what we tend to find behind this code. The notes below are general patterns, not rules, and every house gets measured on its own merits.
Our mild, wet coastal climate matters too. Furnaces here run long, gentle cycles through a long heating season, so a flame sensor that is slowly coating can hold for months before it starts dropping out, and owners often first see the code on the first properly cold week of the year. Rain, moss, needles and fallen leaves are more common culprits at outdoor terminals than snow, although an occasional snowfall can drift over a low terminal. Long run times also mean the condensate system handles plenty of water over a season, so a trap or drain that is only partly blocked can show up as flame or pressure-switch trouble.
Besides Luxaire, we service gas furnaces from York, Coleman, Carrier, Bryant, Lennox, Trane, American Standard, Rheem, Ruud, Goodman, Amana, Keeprite and Napoleon. We service these brands as an independent contractor; we are not a dealer or warranty centre for any of them.
- Vancouver and Burnaby: many older houses have had a newer furnace fitted into an existing basement layout, sometimes with long or awkward vent runs and gas piping that has been added to over the decades. Both are worth checking when flame drops out.
- Surrey, Langley and Delta: many larger and newer homes with high-efficiency furnaces and longer duct runs, where condensate traps, drains and intake pipes near shrubs or fences come up often.
- Richmond: flat, often exposed and windy sites, so vent terminal placement and wind effects on combustion are on our checklist.
- Coquitlam, Port Coquitlam and Port Moody: a mix of older split-levels and newer townhouses. In townhouses and strata homes the furnace often sits in a tight closet with limited service clearance, which affects how the job is planned.
- North Shore: hillside homes, wetter and cooler weather, and more needles and leaves collecting around outside vent terminals.
- New Westminster: older character homes alongside newer strata buildings, so both gas piping history and strata rules on vent locations can come into the job.
More questions homeowners ask
What does 6 flashes mean on a Luxaire furnace?
It means the furnace lit and proved flame, then lost the flame during the heating cycle, often more than once. The control closes the gas valve each time as a safety measure and may lock out after repeated attempts. Confirm the meaning against the manual or code chart for your unit, since control boards differ between generations.
Can I reset a Luxaire furnace that is flashing 6 times?
Once, if your owner’s manual allows it, and only after checking power, the thermostat, the gas shutoff handle, the filter and the outside vent pipes. If the code comes back, stop resetting and call a licensed gas technician. Repeated resets hide the fault and keep sending gas to a burner that is not holding flame properly.
Is it safe to run my Luxaire furnace if it keeps flashing 6 times?
The flame safety is doing its job by shutting the gas off, but the furnace should not be left cycling on a fault. Some causes, such as blocked venting or flame rollout, are genuine safety problems. Turn it off at the thermostat, make sure your carbon monoxide alarms work, and book a diagnosis; if you smell gas or a CO alarm sounds, leave the house and call FortisBC or 911 from outside.
Can a dirty flame sensor cause a Luxaire furnace to flash 6 times?
Yes, a coated or out-of-position flame sensor is the most common cause we find. It is still a licensed job in BC because it means opening the burner area, and a proper visit also checks the sensor ground, gas pressure and venting. Cleaning the sensor without finding out why it lost signal is the main reason this code comes back.
How much does it cost to diagnose a Luxaire furnace error code 6 flashes in Greater Vancouver?
Our diagnostic service call is $189.00, and it covers finding the cause with the proper meters. Any repair is then priced in a written quote before work starts, and you decide whether to go ahead. If the diagnosis leads to a replacement or new installation through BC Wide, the diagnostic charge is waived and taken off the installation.
Do you offer same-day Luxaire furnace repair near me in Greater Vancouver?
Same-day where we can. During cold snaps demand climbs quickly, so we give you the earliest realistic time when you call rather than promise an arrival window. Call (604) 473-9690 with the flash count and what you have already checked, and we will tell you honestly whether it can be seen today.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
Frequently asked questions
How often should a furnace be serviced?
How long does a furnace last in Vancouver's climate?
Why is my furnace blowing cold air?
How much does a new furnace cost in Vancouver?
What is the most reliable furnace brand?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.