On a Maytag furnace, 6 flashes means the control board cannot confirm that the combustion-air inducer (draft) motor is running correctly or at the right speed, so it will not light the burners (confirm against the manual for your unit). The furnace stays off and the house cools. Check that the power switch and breaker are on, the thermostat is calling for heat and the outdoor vent terminals are clear. If the code returns, book a TSBC-licensed technician at (604) 473-9690.
If your Maytag furnace is showing 6 flashes (Inducer / draft motor fault), here’s exactly what it means and what to do. This guide is part of our full Maytag furnace error code list.
Severity: Needs attention.
What 6 flashes means on a Maytag furnace
The control cannot confirm correct operation or speed of the combustion-air inducer (draft) motor, so it will not proceed with ignition.
Common causes
- Failed or seizing inducer motor
- Failed inducer motor capacitor
- Wiring or connector fault to the inducer
- Obstruction in the inducer wheel
What you can safely check first
- Confirm power to the furnace is on and the breaker is set
- No safe homeowner repair — inducer motor diagnosis and replacement is a technician task
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Maytag furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Maytag furnace repair across Greater Vancouver
If a Maytag furnace showing 6 flashes won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Maytag furnace codes
- Maytag furnace Steady on — Normal operation
- Maytag furnace LED off — No power to control
- Maytag furnace Rapid continuous flash — Reversed line polarity / ground fault
- Maytag furnace 1 flash — Failed ignition / flame not established
- Maytag furnace 2 flashes — Pressure switch stuck closed
- Maytag furnace 3 flashes — Pressure switch open / venting fault
Frequently asked questions
Is 6 flashes on a Maytag furnace serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Maytag furnaces 7 days a week across Greater Vancouver.
How do I reset a Maytag furnace after 6 flashes?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Maytag Furnace Error Code 6 Flashes: what it means for your heat and your safety
In owner words, 6 flashes means the furnace tried to start, the small fan that pulls combustion gases out through the vent did not do what the control expected, and the furnace refused to light. Every gas furnace runs that inducer first. It clears the heat exchanger of leftover gases and proves there is a safe path to the outdoors before any gas is allowed to flow. When the control board cannot confirm the inducer is running properly or at the correct speed, it stops the start-up right there. That is the meaning given at the top of this guide and it is the one we work from on site; confirm against the manual for your unit, because control boards and flash tables can differ between production years.
For you, the practical result is simple: no heat. The burners will not light, the house slowly cools, and the furnace may try again a few times before it locks itself out. If your hot water comes from a separate gas tank or tankless water heater, your hot water is not affected by this furnace code. If the furnace shares a vent with another gas appliance, the technician will look at that shared vent as part of the visit, because a venting problem can affect both.
On safety, the code itself is the furnace protecting you. The control will not let gas burn without proof that the flue gases have somewhere to go. The risk comes from what people do next: cycling the power over and over, running the furnace with the door off, or nursing along a motor that is clearly failing. Treat 6 flashes as a stop sign, not an inconvenience to reset around.
The symptoms homeowners describe to us when this code is behind the problem usually sound like this:
- The thermostat is calling for heat but no warm air comes out of the registers.
- You hear a click or a short hum from the furnace, then nothing, and the status light starts blinking.
- A grinding, rattling, squealing or buzzing noise from the furnace a moment before it gives up.
- The furnace runs normally on some calls and fails on others, often on the first cold morning of the season.
- A hot-motor or burning-electrical smell near the furnace, which is a reason to switch it off at the service switch and call.
- A repeating pattern of 6 flashes on the status light, visible through the viewing window on the furnace door if your model has one.
What causes Maytag furnace error code 6, most common first, and what can I check myself?
These are the causes we find most often behind this code, roughly in the order we meet them in Greater Vancouver homes. The first column is the cause, the second is what a homeowner can safely look at without opening the furnace, and the third is the point where it becomes a licensed call. Everything inside the furnace cabinet is technician territory.
The owner-safe checks, in order: make sure the furnace service switch (it looks like an ordinary light switch on or near the furnace) and the breaker are both on. Make sure the manual gas valve on the supply pipe to the furnace is open, which on most quarter-turn valves means the handle lines up with the pipe; if you find it closed and do not know why, leave it closed and call us. Make sure the thermostat is set to heat, set a few degrees above room temperature, and has fresh batteries if it uses them. Walk outside and check the intake and exhaust terminals for snow, leaves, moss, wasp nests or a blown-in plastic bag. Then look at the condensate tubing you can see without removing any panel, for a kink, a tube that has slipped off, or water pooling under the furnace.
If the owner manual for your furnace allows a reset, you may cycle the power once by switching the service switch off, waiting briefly, and switching it back on. If 6 flashes returns, stop there. Do not keep resetting, do not open the burner or blower compartment, do not jumper or bypass any switch, and do not spin the inducer wheel by hand to get it going. A motor that only runs after a push is a motor that will fail again, very possibly on the coldest night of the week.
- Gas and carbon monoxide safety: if you smell gas (a rotten-egg odour) or a carbon monoxide alarm sounds, do not touch switches, do not try a reset and do not use a phone inside. Get everyone out, then call FortisBC or 911 from outside the home.
- Keep working carbon monoxide alarms near sleeping areas and on each level of the home, and test them at the start of every heating season.
- Never cover, tape or block a vent terminal to stop rain or noise; the inducer depends on that open path.
| Likely cause, most common first | What the owner can safely check | When it becomes a licensed call |
|---|---|---|
| 1. Worn or seizing inducer motor, with bearings dragging so it slows down or will not start | Listen from outside the closed cabinet during a start attempt; grinding, squealing or a hum with no spin are useful clues to report | Always. Testing and replacing the inducer means opening the cabinet and disconnecting the vent |
| 2. Failed inducer motor capacitor, on models that use one | Nothing to check; the capacitor sits inside the cabinet and can hold a charge after power is off | Always. A capacitor is tested with a meter by a technician |
| 3. Loose, corroded or damaged wiring or connector at the inducer, or a control board not reading the motor correctly | Confirm the service switch and breaker are on; never open panels or touch wiring | Always. Live voltage and the control board are inside, and the board is diagnosed last |
| 4. Debris, rust flakes or a damaged wheel inside the inducer housing | Check the outdoor intake and exhaust terminals are clear of leaves, snow, nests or ice | If the terminals are clear and the code comes back, the housing must be opened by a technician |
| 5. Water in the inducer housing from a blocked condensate path on a high-efficiency furnace | Look at the visible condensate tubing and drain for kinks, disconnection or standing water | If water is inside the cabinet or keeps backing up, the trap and venting need a technician |
How does a Maytag furnace code 6 repair visit work?
Here is what happens when one of our technicians arrives for this code. The order matters, because replacing an inducer without confirming why it failed is how homeowners end up paying for the same repair twice.
On parts: inducer assemblies are specific to the furnace, and the wheel, mounting, gasket and wiring plug all have to match. We source a part that matches the model and serial number on your furnace’s rating plate rather than forcing a universal motor to fit. If a part has to be ordered, the technician will tell you plainly how the furnace has been left, which is in a safe off state, never running with a safety defeated to buy time.
- Step 1, booking: call (604) 473-9690 and tell us the code, the age of the furnace if you know it, and any noise you heard. We offer same-day where we can, depending on the day’s calls and where you are; we will not promise an arrival window we cannot keep. Diagnostic service calls are $189.00.
- Step 2, confirm the code: the technician reads the status light and any stored fault history, then watches a full start attempt so the inducer can be seen and heard in operation.
- Step 3, measure, do not guess: using a multimeter and, where needed, a clamp meter, the technician checks supply voltage to the furnace, voltage arriving at the inducer, the motor windings, the capacitor on models that have one, and the signal the board relies on to read inducer operation.
- Step 4, check the vent side: the inducer is part of the venting system, so the technician checks the vent connection at the furnace, the pressure-switch tubing and port, the condensate trap on a high-efficiency unit, and the outdoor terminals. A restriction can make a healthy motor look faulty, or shorten the life of a new one.
- Step 5, written quote: if the fix goes beyond diagnosis, you get a written quote naming the part and the work before anything is replaced. The parts most often involved with this code are the inducer motor assembly, its capacitor, a wiring harness or connector, the inducer housing gasket and, less often, the control board.
- Step 6, repair and safety testing: after the repair, the technician runs the furnace through several complete heating cycles and confirms the inducer comes up to speed, the pressure switch proves, ignition and flame sensing are normal, and there is no flue-gas spillage or carbon monoxide at the appliance or in the room.
- Step 7, the paperwork: you receive a written invoice listing what was found, what was replaced and the readings taken. If the motor failed because of a venting or condensate problem, the invoice says so, so the cause gets fixed and the failure is not repeated.
Should I repair or replace an older Maytag furnace showing code 6?
An inducer fault on its own is a repair, not a verdict on the whole furnace. The inducer is a wear part, and replacing it on a furnace that is otherwise sound is usually the sensible call. The decision gets harder on an older furnace that has needed several repairs in recent seasons, has rust in the cabinet or vent connector, or shows signs of a heat-exchanger problem during the safety checks.
What we weigh on site: the age of the furnace from its rating plate; the condition of the heat exchanger and burners; how the venting was installed and whether it suits the furnace; whether parts for that model are still readily available; and your plans for the house. A control board is one of the more expensive parts on a gas furnace, and if the board and the inducer are both failing on an older unit, the case starts to lean toward replacement. We put both options in writing and let you decide; we do not push a replacement on a furnace that only needs a motor.
If you are considering replacement, the in-home estimate for new equipment is free. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.
Many Metro Vancouver homeowners use a furnace failure as the moment to look at a dual-fuel system: a heat pump that handles heating and cooling through most of our mild, wet season, paired with a gas furnace that takes over during cold snaps. It keeps a gas furnace in the house as dependable backup, and it adds central air conditioning for the hotter summers we now get. We can quote a straight furnace replacement and a dual-fuel option side by side so you can compare them on paper.
Whichever way you go, a correct replacement quote should show the following in writing:
- The make and model of the new furnace, and of the heat pump if it is a dual-fuel system
- How the equipment was sized for your home, not simply matched to the old furnace
- Venting and condensate work, including where the terminals will exit the house
- Any gas piping changes and the gas permit that covers them
- Removal and disposal of the old furnace
- Warranty registration responsibilities and our labour warranty, stated in writing
Maytag furnace error code 6 service near me in Greater Vancouver: which areas do we cover?
We service Maytag furnaces across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley, working from our base in Burnaby. Housing stock varies a lot across the region, and it changes what we look for on an inducer call.
In Vancouver and Burnaby, many older detached homes have had more than one furnace over the decades, and the venting or gas piping may date from an earlier appliance. When we replace an inducer in that kind of house, we also check that the venting still suits the furnace now installed. In New Westminster and on the North Shore, older homes on sloped lots often tuck the furnace into tight basements, and damp hillside sites can bring rust to the cabinet base; low side-wall terminals can collect leaves, moss and, at higher elevations, snow.
In Surrey, Langley and Delta, many newer subdivisions have high-efficiency furnaces vented with plastic pipe through a side wall, where shrubs, fences, decks and leaf piles tend to crowd the terminals. In Richmond, garage and crawlspace installations are common in some houses, so we pay close attention to condensate lines and traps. Across Coquitlam, Port Coquitlam and Port Moody there is a mix of older split-levels and newer townhouse and strata developments; in strata homes the furnace often sits in a closet with venting through shared walls or roofs, so we confirm what the strata allows before any change to venting.
Our mild, wet coastal climate is hard on inducers in a quiet way. Furnaces run long, gentle heating seasons, condensing furnaces produce condensate almost every cycle, and outdoor terminals sit in rain and leaf litter for months. Cold snaps are when inducer motors that have been dragging all season finally stop, which is why calls for this code tend to bunch up on the first frosty mornings.
Brands we service: alongside Maytag, we service gas furnaces from Amana, Goodman, Carrier, Bryant, Lennox, Trane, Rheem, York, Daikin and Napoleon.
Who should repair a Maytag furnace inducer fault, and what should I see in writing?
BC Wide Home Services Ltd is an independent, TSBC-licensed gas contractor (licence LGA0090068), and our gas fitters work under Class B gas licence CGA0028029. We are not a Maytag dealer or a factory warranty centre. We are the independent contractor homeowners call to diagnose and repair the furnace they already own, whatever the brand, and we have been doing that across Metro Vancouver since 1999.
Licensing matters for this code because replacing an inducer means disconnecting and reconnecting the vent at the furnace, working around the gas valve and the control board, and then proving that combustion gases leave the house properly. Gas work in BC is legally restricted to licensed gas fitters, and most electrical work inside the furnace belongs with qualified technicians too. The homeowner’s part ends at the owner-safe checks listed above.
A straight inducer replacement with no venting change is a repair. If the job turns into a vent correction, a gas piping change or a furnace replacement, we take out the gas permit and arrange the inspection through Technical Safety BC or, where the municipality handles gas permits itself, through the city. You should never have to ask whether a permit applies; we tell you up front.
Before and after the work, this is what you should see from us in writing:
- The diagnosis in plain words, with the readings that support it
- A written quote before any work beyond diagnosis begins
- The parts replaced, named on the invoice
- Permit details whenever a permit applies
- Safety test results after the repair: inducer operation, pressure switch, ignition, flame sensing and carbon monoxide checks
- Any related problem we found, such as a blocked condensate trap or crowded vent terminal, and what we recommend about it
More questions homeowners ask
What does 6 flashes mean on a Maytag furnace?
It means the control board cannot confirm that the combustion-air inducer (draft) motor is running correctly or at the right speed, so it will not proceed with ignition. The furnace stays off until the fault clears or is repaired. Confirm the meaning against the manual for your unit, since flash tables can vary between production years.
Can I reset a Maytag furnace showing error code 6?
Only if your owner manual allows it, and only once: switch the furnace service switch off, wait briefly and switch it back on. If 6 flashes returns, leave the furnace off and call a licensed technician. Repeated resets do not fix a failing inducer and can hide a real safety problem.
Is it safe to run my Maytag furnace with code 6 flashes?
The furnace will not light while the code is active, which is the control doing its job. It is not safe to try to force it to run by bypassing switches, spinning the inducer by hand or running it with panels off. If you smell gas or a carbon monoxide alarm sounds, leave the home and call FortisBC or 911 from outside.
Why does my Maytag furnace code 6 keep coming back after a reset?
Usually because the inducer motor is wearing out and only starts some of the time, or because a wiring connection or capacitor is intermittent. A blocked vent terminal or water in the inducer housing on a high-efficiency furnace can also cause repeat failures. A technician with meters can tell which, so the right part is replaced the first time.
How long does a Maytag furnace inducer repair take?
When the correct inducer assembly is available, the repair and safety testing are often completed in a single visit. If the part for your model has to be ordered, the furnace is left safely off and we return once it arrives. We offer same-day service where we can, but we never promise a guaranteed arrival time.
Who repairs Maytag furnace error code 6 near me in Greater Vancouver?
BC Wide Home Services Ltd, an independent TSBC-licensed gas contractor based in Burnaby, repairs Maytag furnaces across Vancouver, Burnaby, Surrey, Richmond, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Diagnosis is done by our own licensed technicians, and you get a written quote before any repair work. Call (604) 473-9690 to book.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
Frequently asked questions
How often should a furnace be serviced?
How long does a furnace last in Vancouver's climate?
Why is my furnace blowing cold air?
How much does a new furnace cost in Vancouver?
What is the most reliable furnace brand?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.