A Munchkin boiler lockout means the control has stopped the burner after repeated failed attempts to light or prove flame, or after a safety limit tripped, and it will not restart on its own. Most lockouts we see trace to the ignition and flame-sensing chain first, then venting and condensate, then water pressure or flow. You may check power, the gas supply valve, the thermostat, the outdoor vents and the condensate drain, and reset once if the manual allows. Anything inside the cabinet is licensed work.
- On a legacy Munchkin, the most common lockout pattern is a failed or dirty ignition and flame-sensing chain: the burner tries to light, proves flame briefly or not at all, then shuts down after its retry count.
- Repeated lockouts in a cold snap or wet weather usually point to venting and condensate: blocked or flooded condensate drains, obstructed intake or exhaust, or ice and debris at the terminations.
- Water-side issues such as low system pressure, trapped air, and sludge in the heat exchanger cause a different rhythm: the boiler fires, overheats or short-cycles, then locks out on a temperature or flow safety.
- A homeowner may safely observe the display, check system pressure on the gauge, look at the condensate drain and the outdoor vent terminations, and reset the boiler once.
- Anything involving the gas valve, burner, igniter, flame sensor, heat exchanger, combustion analysis or the control board is licensed work in BC.
- BC Wide services Munchkin boilers as an independent TSBC-licensed contractor; we do not quote what a specific code means, because the pattern of behaviour is more reliable than the number on the screen.
When a legacy Munchkin boiler locks out, the most likely cause is a fault in the ignition and flame-proving chain: a worn igniter, a flame sensor coated in deposits, or a burner that cannot hold a stable flame because of a venting or gas-supply issue. The control tries to light, fails to see a clean flame signal within its allowed window, retries a set number of times, then locks out and waits for a reset. Watching what the boiler does in the seconds before it locks out tells you far more than the code on the display. This page walks a Metro Vancouver homeowner through reading that behaviour, checking the few things that are safe to check, and recognising the point where an independent, licensed technician needs to take over.
What is a lockout on a Munchkin boiler, and why does it keep happening?
A lockout is the control board deliberately refusing to run until someone resets it. It is not a breakdown in the usual sense. It is the boiler protecting itself and the house. The Munchkin control monitors a chain of conditions every time it tries to fire: is there enough air moving through the venting, is the gas valve opening, did the igniter spark, did the flame sensor prove a flame, is the water temperature and flow within limits. If any link in that chain fails, the board either retries or shuts the whole sequence down.
Some faults cause a soft lockout that clears on its own after a delay. Others cause a hard lockout that stays until you press reset. A boiler that locks out once in a winter is not a crisis. A boiler that locks out every day, or several times a day, is telling you one link is marginal and getting worse. Legacy Munchkin units in Lower Mainland homes are now well into their service life, so marginal components are the norm rather than the exception.
We deliberately do not tell you what any specific Munchkin code means on this page. Fault tables changed between control revisions, printed labels inside the cabinet are often faded, and the same number can be triggered by several different root causes. Reading the behaviour, then confirming with instruments, is how a technician actually diagnoses these boilers. Treat the display as a hint, not a verdict, and verify against the manual for your exact control revision.
What does the boiler do right before it locks out?
Stand near the boiler when it gets a call for heat and watch the sequence. Most Munchkin lockouts fall into one of a handful of patterns, and each pattern narrows the cause considerably before anyone opens the cabinet.
| What you observe | Most likely area | What it usually turns out to be |
|---|---|---|
| Blower runs, you hear repeated clicking or sparking, no whoosh of ignition, then lockout | Ignition chain | Worn igniter, weak spark, gas valve not opening, or air in the gas line after service |
| Burner lights for a second or two, then drops out, repeats a few times, then lockout | Flame proving | Flame sensor coated in deposits, poor flame rectification ground, or unstable flame from venting problems |
| Blower ramps up, hesitates or hunts, boiler never attempts ignition, then lockout | Air and venting | Blocked intake or exhaust, flooded condensate trap, pressure switch or air-proving fault |
| Boiler runs fine for minutes, water gets hot fast, then shuts down on a limit and locks out | Water side | Low system pressure, trapped air, closed valve, failed circulator, or sludge restricting the heat exchanger |
| Lockouts only in heavy rain, wind or freezing weather | Terminations and condensate | Wind-driven recirculation at the vent, ice at the termination, or condensate line backing up |
| Random lockouts with no pattern, sometimes display resets itself | Electrical and control | Loose low-voltage connection, poor grounding, failing transformer or control board |
Why does the flame sensor cause so many Munchkin lockouts?
The flame sensor is a small metal rod sitting in the burner flame. It does not detect heat. It relies on a tiny electrical current that only flows when a flame is present, a process called flame rectification. The control looks for that current within a short window after the gas valve opens. If the current is weak or absent, the board assumes there is no flame, closes the gas valve for safety, and either retries or locks out.
On an older condensing boiler, the rod slowly picks up a glassy coating from years of combustion. That coating insulates it, the signal drops, and the boiler starts dropping out a second or two after lighting. This is the classic legacy Munchkin lockout. The fix is usually cleaning or replacing the rod and checking the ground path back to the burner. It is a quick job for a technician, but the burner assembly has to come apart and the gas side must be checked and leak-tested afterwards, which is why it is not a homeowner task.
A weak flame signal can also be a symptom rather than the cause. If the burner flame is lifting, rolling or yellow because the venting is restricted or the gas and air mix is off, the sensor sees an unstable flame and drops out. That is why a technician will check the venting, gas pressure and combustion readings before assuming the rod alone is at fault.
Can venting and condensate really shut a boiler down?
Yes, and on the coast this is the second most common cause. A Munchkin is a sealed-combustion, condensing boiler. It pulls outside air through an intake pipe, pushes exhaust out through a plastic vent, and produces a steady stream of acidic condensate that has to drain away. All three paths must be clear for the control to allow ignition.
The condensate trap and drain line collect debris over time. If the trap clogs or the drain freezes, condensate backs up into the boiler. Some controls sense that as a blocked-flue or air-proving condition and refuse to fire. Others let the boiler fire and the flame becomes unstable as water pools near the burner. Either way you get lockouts, and often a gurgling or sloshing sound as a clue.
Outside, the intake and exhaust terminations matter. Leaves, nests, snow, ice on a cold morning, or a termination too close to a wall corner that lets exhaust recirculate into the intake will all upset combustion. Homeowners can safely look at the outdoor terminations from the ground and clear obvious debris from around them. Do not disconnect or modify any vent piping; joints on a condensing boiler vent are part of the gas-safety system and are inspected as such in BC.
What water-side problems cause a Munchkin to lock out?
A different rhythm of lockout comes from the hydronic side. The boiler lights cleanly, runs, and then the water temperature climbs too fast because not enough water is moving through the heat exchanger. A high-limit or temperature-rise safety trips and the boiler locks out. When you hear the burner run normally for a few minutes and then stop with the display showing a fault, think water first.
Check the pressure gauge on the boiler or near it. Legacy systems slowly lose pressure through tiny weeps, automatic air vents and expansion tanks that have lost their charge. When the pressure drops below what the boiler expects, a low-water condition or trapped air develops and flow through the exchanger falls off. Metro Vancouver water is soft, so the problem in our hydronic systems is not limescale. It is sludge: fine black magnetite and corrosion products that settle in the narrow passages of a stainless heat exchanger and in circulator pumps.
Sludge restricts flow gradually, so the symptom often appears over a season as more frequent short-cycling and occasional lockouts. A technician will measure the temperature rise across the boiler, check the circulator, look for closed or partially closed valves, and if sludge is suspected, flush the system and add a proper inhibitor. Homeowners can read the gauge and listen for air, but topping up the system, purging air and flushing are technician tasks on a sealed boiler because they interact with the pressure relief valve and the fill assembly.
What can a homeowner safely check before calling anyone?
There is a short list of safe checks that often either solve the problem or give the technician a head start. None of them involve gas, wiring, the burner or the venting joints.
- Watch one full attempt: note whether you hear the blower, spark, ignition, and how long the flame lasts before shutdown.
- Read the pressure gauge with the system cool. If it sits very low or near zero, mention that when you call rather than adding water yourself.
- Look at the condensate drain tubing for kinks, sags holding water, or a trap that looks full of debris. Do not open the trap on a running boiler.
- Go outside and look at the intake and exhaust terminations for leaves, ice, nests or snow. Clear only what you can reach from the ground without touching the pipe.
- Check that the thermostat is calling for heat and that any zone valves or zone pumps you can hear are actually running.
- Confirm the gas supply is on at other appliances. If your gas fireplace or range also fails to light, the problem may be the supply, and the utility should be your first call.
- Press reset once. If it locks out again on the same pattern, stop. Repeated resets mask the fault and can stress an igniter or gas valve that is already marginal.
How do Metro Vancouver conditions change Munchkin lockouts?
Our climate is mild, wet and slow to freeze, which shapes how these boilers fail. Long damp shoulder seasons mean the boiler cycles constantly at low fire for months, which accelerates flame-sensor coating and lets condensate drains gunk up. Then a short cold snap in January or February pushes the boiler to high fire for the first time in a year, and the marginal component finally fails. That is why so many Munchkin lockout calls arrive in the first cold week rather than mid-winter.
Freezing is rare but not absent. Condensate lines routed through an unheated garage or along an outside wall in Burnaby, Coquitlam or North Vancouver can freeze in that same cold snap and back up. Vent terminations at ground level on the north side of a house can ice over. When a lockout follows a frost, check those two places first.
Our housing stock also matters. Many Munchkins were installed in older homes during the first wave of condensing boilers, sometimes onto original piping and radiators with decades of iron sludge inside. Soft water means no limescale, but it also means aggressive corrosion if the system was never treated with an inhibitor. Strata townhouse complexes with shared mechanical rooms often have several of these boilers side by side, and a venting or gas-supply problem in one can affect its neighbour. Finally, any gas work in BC requires a licensed gas fitter working under a TSBC licence and, for replacements or vent changes, a permit and inspection. That is not red tape; it is what keeps a combustion appliance in a living space safe.
When is a Munchkin lockout a job for a licensed technician?
The line is simple. Observing, reading a gauge, looking at terminations and pressing reset once are homeowner steps. Everything past that point is licensed work under BC gas and electrical regulations, and for good reason: the parts involved control fuel and combustion in your home.
- The boiler locks out again after a single reset, or the lockouts are becoming more frequent.
- You smell gas, hear a hissing sound, or a carbon-monoxide alarm has sounded at any time. Leave the house first, then call the gas utility emergency line, then us.
- You see soot, scorching, or discolouration around the burner door or vent connections.
- The system pressure is very low or the pressure relief valve has been dripping.
- The condensate trap needs opening, the burner needs cleaning, or the flame sensor or igniter needs attention.
- Any vent joint, intake pipe, gas connection or wiring needs to be touched.
- The boiler is on its original heat exchanger and you want an honest assessment of repair versus replacement.
What does independent Munchkin service from BC Wide actually involve?
BC Wide Home Services is an independent TSBC-licensed contractor, licences LGA0090068 and CGA0028029, based in Burnaby and serving Metro Vancouver since 1999. Munchkin is a brand we service; we are not a factory dealer, and we do not need to be. Diagnosing a lockout is about instruments and method, not brand affiliation.
A proper visit starts with the behaviour you observed, then moves to measurement: a combustion analyser on the exhaust, gas pressure at the valve, the flame signal in microamps, the temperature rise across the exchanger, and a look inside the condensate trap and burner. From there the technician can tell you whether this is a maintenance issue, a single worn part, or the start of a heat-exchanger or control-board conversation. A control board is one of the more expensive components on a boiler of this age, so we will always tell you plainly if repair no longer makes sense against the remaining life of the unit, and provide a written quote before any work beyond the diagnosis.
If you are dealing with a Munchkin that locks out and you would rather not keep resetting it, call (604) 473-9690. Tell us the pattern you saw; it genuinely shortens the visit.
Frequently asked questions
Why does my Munchkin boiler lock out every morning?
A once-a-day lockout that happens on the first cold call for heat usually points to a marginal ignition or flame-sensing component that only fails when the boiler starts from cold. A flame sensor with a light coating, a tired igniter, or a condensate drain that fills overnight will all produce that timing. Watch one morning attempt and note whether the flame lights at all before it drops out; that detail helps a technician go straight to the cause.
Is it safe to keep resetting a Munchkin boiler?
One reset is reasonable. Repeated resets are not. The lockout exists because the control detected an unsafe or failing condition, and each retry cycles the gas valve and igniter against that condition. If it locks out again on the same behaviour, leave it off and book a licensed technician. If there is any smell of gas or a CO alarm, do not reset at all.
Can I clean the flame sensor on my Munchkin myself?
No. Reaching the flame sensor on a Munchkin means opening the sealed burner assembly, which places you inside the gas and combustion path. In BC that is licensed gas-fitter work, and the assembly has to be resealed and leak-checked afterwards. It is a short job for a technician and usually done alongside a combustion check, which is the part that actually confirms the boiler is running safely.
Does soft Metro Vancouver water mean my boiler will not scale up?
Correct, limescale is not the issue here. The water-side problem in our region is sludge and corrosion: magnetite and iron oxide from old piping and radiators settling in the heat exchanger and circulator. That restricts flow, causes overheating and short-cycling, and can end in a limit lockout. The remedy is a proper flush and an inhibitor, not a descaler.
My Munchkin only locks out when it is windy or raining hard. Why?
Weather-linked lockouts almost always involve the intake, exhaust or condensate. Strong wind can push exhaust back toward the intake or upset the pressure the control expects to see, and heavy rain or freezing weather can flood or block the condensate path. Check the outdoor terminations from the ground and the condensate tubing for standing water; if either looks suspect, have a technician assess the termination location and drain routing.
Does BC Wide need to be a Munchkin dealer to work on my boiler?
No. BC Wide is an independent TSBC-licensed contractor, and Munchkin is a brand we service rather than one that certifies us. Diagnosing a lockout depends on combustion analysis, gas-pressure measurement and flame-signal readings, which any properly licensed and equipped technician performs. Parts availability for legacy units is something we will discuss honestly on the visit.
Should I repair or replace an old Munchkin that keeps locking out?
It depends on what the lockout turns out to be. A flame sensor, igniter, condensate cleaning or system flush is usually worth doing on a boiler with life left in its heat exchanger. If the diagnosis points to the heat exchanger or the control board, replacement often makes more sense given the age of these units and the availability of parts. Ask for a written assessment that separates the immediate fix from the longer-term picture.
BC Wide Home Services — Lower Mainland home-comfort specialists since 1999
Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians · Evening and weekend calls · Diagnostic service calls $189.00 · Free in-home estimates on replacements (the $189.00 is waived if you replace with us). Call 604-473-9690 or book a free replacement estimate.
Munchkin Boiler Lockout Behaviour Explained: what we check first
When we walk up to a locked-out Munchkin, we do not start with the number on the display. We start with the order of events: did the burner try to light, did it light and drop out, or did it run hot and shut down? That sequence narrows the cause faster than any code, and it is why we tell owners to note what the boiler was doing before it stopped. If you want the meaning of a specific display message, confirm against the manual for your unit.
The table below lists the likely causes in the order we most often find them on legacy Munchkin boilers in Greater Vancouver, what the owner usually notices, the checks that are safe for a homeowner, and the point where it becomes a call for a licensed gas fitter.
| Likely cause (most common first) | What you usually notice | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Ignition and flame-sensing chain | Clicking or a short whoosh, the burner tries several times, then the boiler goes quiet with a lockout showing | Note what you saw and when; do not open the cabinet | Always: the igniter, flame sensor, burner and gas valve are licensed work |
| 2. Condensate drain or trap blocked | Gurgling from the drain line, water under the boiler, lockouts during long run times | Look at the visible drain tube for kinks, a disconnected end, or an outdoor run that has frozen or clogged | If water is inside the cabinet, the trap needs cleaning, or a condensate pump has failed |
| 3. Intake or exhaust obstruction | Lockouts in wind, heavy rain, a cold snap, or after leaves come down | From outside, look at the vent terminals for leaves, nests, snow or anything stacked against them | If the terminals are clear and it still locks out, or any vent pipe is cracked, sagging or separated |
| 4. Low system pressure or trapped air | Gauge reading below the range on the label, gurgling in pipes, some rooms cold | Read the pressure gauge and compare it with the label or manual | Any refill, air purging, or repeated pressure loss, which points to a leak, expansion tank or relief valve problem |
| 5. Restricted water flow or sludge | Boiler fires, gets loud or kettles, short-cycles, then locks out on a temperature safety | Note whether radiators or floors heat unevenly | Always: flushing, circulator and heat exchanger work need a technician |
| 6. Gas supply problem | Repeated failed lights, other gas appliances also not working | Confirm the supply valve handle is in line with the pipe and check whether your range or water heater works | Any gas pressure testing, valve work or meter question |
| 7. Power or control issue | Blank display, intermittent restarts, lockouts with no pattern | Confirm the boiler switch is on and the thermostat is calling for heat | A tripped breaker that trips again, wiring, sensors or the control board |
What does a Munchkin boiler lockout mean for your heat, hot water and safety?
For heat, a lockout means the boiler has stopped supplying hot water to your radiators, baseboard convectors or in-floor loops, and the house will cool at whatever rate the weather allows. In a mild coastal winter that can take hours; in a cold snap it is faster. For hot water, it depends on how your system is piped. If your domestic hot water comes from an indirect tank heated by the boiler, a lockout usually means no hot water as well, once the stored water is used up.
For safety, a lockout is the boiler doing its job. It has detected something it cannot prove is safe, such as unstable flame, blocked venting or water that is too hot, and it has shut down rather than keep trying. That is why repeated resetting is the wrong answer. Each reset asks the boiler to try again under the same conditions that stopped it.
Gas and carbon-monoxide safety: if you smell gas or your CO alarm sounds, leave the home right away and call FortisBC or 911 from outside. Do not reset the boiler, operate switches or use a phone inside the house. Every home with a gas boiler should have working CO alarms near sleeping areas.
- The house is cold and the boiler display shows a lockout or fault
- It tried to light a few times, then went quiet
- It ran fine for a day after a reset, then locked out again
- No heat and no hot water from the indirect tank at the same time
- Water dripping or pooling under the boiler
- A gurgling sound from the condensate line
- Lockouts only in heavy rain, wind or a cold snap
How does our Munchkin boiler repair visit work, step by step?
Diagnostic service calls are $189.00. That covers a licensed technician on site working through the boiler in a fixed order, so the cause is found rather than guessed. We offer same-day service where we can, but we do not promise an arrival window; it depends on the day’s calls and how far we are from you.
- Step 1, the phone call: when you call (604) 473-9690 we ask what the display shows, when it started, what the boiler did before it stopped and what you have already checked.
- Step 2, safety first on arrival: we check for gas odour and carbon monoxide in the mechanical space and look over the venting before anything is restarted.
- Step 3, history and a watched start: we read the fault history the control has stored and watch a full light-off sequence to see exactly where it fails.
- Step 4, measurement with the right meters: a combustion analyser for the flue gas, a manometer for gas pressure, a multimeter for sensors and wiring, and a flame-signal reading on the sensing circuit.
- Step 5, inspection of the parts most often involved: the igniter, flame sensor, burner and its gaskets, condensate trap and drain, vent connections, circulator, temperature and pressure sensors, and the control board connections.
- Step 6, a written quote before any work beyond diagnosis: you see what we found, what we recommend and what it involves before we touch anything.
- Step 7, repair and test the safeties: after a repair we confirm stable flame, check combustion, and prove the limits, low-water protection and condensate path over several full cycles.
- Step 8, notes you keep: a written record of what we found and did, which helps on any future visit.
Should you repair or replace an older Munchkin boiler that keeps locking out?
Repair usually makes sense when the heat exchanger is sound, the venting is correct, and the lockouts trace to one worn part such as an igniter or a fouled flame sensor. Those are routine repairs on a condensing boiler. A control board is one of the more expensive parts, and on older legacy models parts availability can stretch the timeline, so we tell you that before you decide.
Replacement starts to make sense when the heat exchanger is fouled with sludge or showing corrosion, when lockouts keep returning after the obvious parts have been replaced, when the venting would need major rework anyway, or when parts for your particular model are hard to source. In those cases you can end up paying for a series of repairs on a boiler that is still at the end of its life.
If you are weighing a replacement, the in-home estimate for a new boiler or combi boiler is free, and it comes with a written quote that covers the boiler, venting, condensate, gas piping, permits and inspection. If you go ahead with a replacement or new installation through BC Wide, the diagnostic charge is waived and taken off the installation. Gas boiler installations need a gas permit and inspection through the authority having jurisdiction for your address, and we arrange that as part of the job.
Munchkin boiler lockout service near me in Greater Vancouver
We service Munchkin boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock differs across the region, and it changes what we tend to find on a lockout call, so treat the notes below as patterns from our work, not rules.
In Vancouver, Burnaby and New Westminster, many boilers sit in older houses where a condensing boiler was fitted into a tight basement or utility room, sometimes with long vent runs or a condensate line routed to a distant drain. Those details often show up in lockouts. On the North Shore and in hillside parts of Coquitlam and the Tri-Cities, wetter weather, heavy leaf fall and moss near side-wall terminals are common contributors. In Surrey, Delta, Langley and Richmond, newer subdivisions often have vent terminals close to fences, walkways or neighbouring walls, where debris, snow drifts or recirculated flue gas can affect combustion.
Metro Vancouver water is soft, so on the water side we look for sludge and corrosion rather than limescale. That matters for older Munchkin heat exchangers, where restricted flow can trigger temperature-related lockouts.
Why use an independent TSBC-licensed contractor for Munchkin boiler service?
BC Wide Home Services Ltd has served Metro Vancouver since 1999 as an independent contractor licensed by Technical Safety BC, licence LGA0090068, with Class B gas licence CGA0028029. Gas work on your boiler is done by licensed gas fitters, permits and inspections are handled where the work requires them, and you get a written quote before any work beyond diagnosis.
We are not a factory-authorized dealer or a manufacturer’s warranty centre. If your boiler may still be under warranty, the claim goes through the manufacturer or the original installing dealer, and we will tell you if that looks like the better route. Boiler brands we service include Munchkin, IBC, Viessmann, Lochinvar and Weil-McLain, along with combi boilers from Navien, Bosch and Rinnai.
More questions homeowners ask
What does a lockout mean on a Munchkin boiler?
It means the control has shut the burner down after it could not light or prove flame, or after a safety limit tripped, and it will not restart until it is reset. The display may show a message, but the meaning should be confirmed against the manual for your unit. The pattern of behaviour before the lockout usually tells a technician more than the message itself.
Can I reset a Munchkin boiler that is locked out?
Yes, once, and only if the owner manual for your unit says a reset is allowed. Before you do, check the power switch, the gas supply valve, the thermostat, the outdoor vents and the visible condensate drain. If it locks out again, stop resetting and call a licensed technician.
Is it safe to run a Munchkin boiler that keeps locking out?
No. Repeated lockouts mean the boiler keeps detecting a condition it considers unsafe, such as poor combustion, blocked venting or overheating. Forcing it to keep running hides the cause and can damage parts. If you smell gas or a CO alarm sounds, leave the home and call FortisBC or 911 from outside.
Why does my Munchkin boiler lock out again a day after I reset it?
The reset cleared the lockout but not the cause. A weak flame signal, a condensate trap that slowly fills, a partly blocked vent or slowly dropping system pressure will all let the boiler run for a while before tripping again. That on-and-off pattern is a strong sign it needs a diagnostic visit.
Do you offer same-day Munchkin boiler repair in Greater Vancouver?
Same-day where we can, depending on the day’s workload and your location; we do not guarantee an arrival window. Call (604) 473-9690 and tell us what the boiler was doing before it stopped, so the technician arrives with the right parts in mind.
Is BC Wide a Munchkin dealer or warranty centre?
No. BC Wide is an independent TSBC-licensed contractor that services Munchkin boilers. Warranty claims go through the manufacturer or the original installing dealer, and we will tell you if your situation points that way.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.