Napoleon Furnace Code 6 flashes — Too many limit trips in one call for heat | BC Wide

Error Codes, Furnace, Hvac

Napoleon Furnace Code 6 flashes — Too many limit trips in one call for heat | BC Wide — BC Wide Heating & Air Conditioning, Greater Vancouver
Home › Napoleon Furnace Code 6 flashes — Too many limit trips in one call for heat | BC Wide

Napoleon Furnace Code 6 flashes — Too many limit trips in one call for heat | BC Wide

Quick answer

On a Napoleon furnace, 6 flashes means the high-limit switch opened repeatedly during one call for heat, so the control is reporting a persistent overheating or airflow problem rather than a one-off trip (confirm against the manual for your unit). Replace a dirty filter, open every supply and return register and clear the return grille. If the code comes back, stop resetting and book a licensed technician. BC Wide services Napoleon furnaces across Greater Vancouver: call (604) 473-9690.

If your Napoleon furnace is showing 6 flashes (Too many limit trips in one call for heat), here’s exactly what it means and what to do. This guide is part of our full Napoleon furnace error code list.

Severity: Needs attention.

What 6 flashes means on a Napoleon furnace

The high-limit switch opened repeatedly during a single heating cycle, indicating a persistent overheating/airflow problem rather than a one-time trip.

Common causes

  • Severely restricted airflow from a clogged filter or blocked vents
  • Blower motor not running at proper speed
  • Restricted or undersized ductwork
  • Failing limit switch

What you can safely check first

  1. Replace the air filter if it is dirty
  2. Open all supply and return registers and clear any obstructions
  3. Make sure the return-air grille is not blocked
  4. If the code persists with a clean filter and open vents, call a technician

Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.

When to call a technician

This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Napoleon furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.

BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.

Napoleon furnace repair across Greater Vancouver

If a Napoleon furnace showing 6 flashes won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.

Related Napoleon furnace codes

Frequently asked questions

Is 6 flashes on a Napoleon furnace serious?

It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Napoleon furnaces 7 days a week across Greater Vancouver.

How do I reset a Napoleon furnace after 6 flashes?

You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.

Napoleon furnace error code 6 flashes: what you will notice at home

In plain terms, heat is building up inside the furnace faster than the blower and ductwork can carry it away, and the safety switch that guards against overheating kept opening during a single heating cycle. Each time the limit opens, the control shuts the burners off and keeps the blower running to cool the heat exchanger. When that happens more often than the control allows in one call for heat, it stops trying and shows 6 flashes. Confirm the exact wording against the manual for your unit, because control boards differ between model generations.

For you, that usually means a house that will not warm up even though the furnace seems to be running constantly. The code is a protective lockout, not a gas leak alarm, but it is the furnace telling you that something is stopping heat from leaving the cabinet. Running a furnace hot over and over stresses the heat exchanger, and a cracked heat exchanger can let combustion gases, including carbon monoxide, into the air stream. That is why this code deserves a proper diagnosis rather than repeated resets.

These are the things homeowners usually describe to us when they call about this code:

  • The burners light and warm air comes out for a few minutes, then the flame goes out while the fan keeps blowing.
  • Heat comes and goes in short bursts and the thermostat never reaches its setting.
  • Air at the registers feels very hot at first, then weak or barely moving.
  • A hot, dusty or slightly scorched smell near the furnace or from the vents.
  • Rooms at the far end of the duct runs, often upstairs bedrooms, are noticeably colder than the rest of the house.
  • The status light on the furnace control flashes 6 times in a repeating pattern, and eventually the furnace stops trying altogether.
  • The blower sounds louder, quieter or rougher than it used to.

Napoleon furnace error code 6 flashes: likely causes, most common first, and what you can check

The list below is roughly the order in which we find these faults on Greater Vancouver service calls, most common first. The owner-safe checks are the only steps you should take yourself. Anything inside the burner compartment, the blower compartment or the control wiring is licensed work in BC, and bypassing or jumpering a limit switch is never acceptable: that switch is the reason the furnace shut itself down instead of overheating.

First: a clogged or unsuitable air filter. A filter packed with dust is the single most common reason a furnace overheats. A very dense pleated filter fitted to a system that was never designed for it can choke airflow almost as badly as a dirty one. Pull the filter, hold it up to a light, and replace it with the size printed on the frame. Never run the furnace without a filter while you wait for a new one.

Second: closed or blocked registers and return grilles. Closing vents in unused rooms, a sofa pushed against a return grille, or a rug laid over a floor register all add resistance. The furnace was sized to move a certain volume of air, and every closed opening pushes it closer to its limit.

Third: a blower problem. A weakening motor, a failing run capacitor, a blower wheel caked with dust, a speed setting changed during an earlier repair, or a fault in a variable-speed motor module will all reduce airflow. You can confirm that the fan actually runs when the burners are on, but testing or replacing blower components is a licensed job.

Fourth: ductwork that is undersized, crushed, disconnected or extended during a renovation without anyone recalculating the system. This is common in homes where a basement suite or addition was tied into the original ducts. You may look at visible flex duct in a basement or crawlspace for kinks or collapsed sections; do not open the plenum.

Fifth: a dirty evaporator coil. If you have central air conditioning or a heat pump, its indoor coil sits directly in the furnace airflow. A coil matted with dust restricts air every bit as much as a dirty filter, and it is hidden inside a sealed cabinet, so cleaning it is technician work.

Sixth: a failing limit switch, or a burner firing harder than it should because of a gas pressure or orifice problem. These are licensed-only diagnoses. Gas pressure is measured with a manometer by a licensed gas fitter, and a limit switch is replaced only after the airflow cause has been ruled out.

Owner-safe checks, in this order, before you call:

  • Confirm the furnace power switch, which looks like an ordinary light switch on or near the cabinet, is on, and that the breaker has not tripped.
  • Confirm the gas shut-off valve on the pipe feeding the furnace is open, with its handle running in line with the pipe. Do not touch any other fitting on the gas line.
  • Set the thermostat to heat, a few degrees above room temperature, and replace its batteries if it uses them.
  • On a high-efficiency furnace, check the outside intake and exhaust pipes for leaves, snow, ice, wasp nests or bird nests, and clear them by hand from outside only.
  • Look at the clear condensate tube and trap where you can see them without removing any panel. A tube that is visibly full of water, kinked or disconnected is worth mentioning when you book.
  • If your owner manual allows a reset, do it once: switch the power off, wait a minute, switch it back on. If 6 flashes returns, leave the furnace off and call a licensed technician.
Likely causeWhat the owner may checkWhen it becomes a licensed call
Dirty or overly dense air filterReplace the filter with the correct size from the frame labelCode returns with a clean, correct filter in place
Closed or blocked registers and returnsOpen every supply register, clear furniture and rugs from returnsCode returns with every opening clear
Blower motor, capacitor, wheel or speed settingConfirm the fan runs while the burners are litAlways; blower testing and repair are licensed work
Undersized, crushed or disconnected ductworkLook for kinked or collapsed flex duct you can see without opening anythingAlways; static pressure must be measured and ducts corrected
Dirty indoor coil from an AC or heat pumpNothing; the coil is inside a sealed cabinetAlways; coil cleaning is technician work
Failing limit switch or a burner overfiringNothing; do not touch the gas valve or wiringAlways; gas pressure and safeties require a licensed gas fitter

How our Napoleon furnace error code 6 repair visit works, step by step

A limit-trip lockout is one of the codes where a quick reset and a new filter can hide the real problem for a week or two. Our visit is built to find the cause, prove it with measurements, and show you the numbers before anything is replaced. Diagnostic service calls are $189.00.

Here is what happens from the phone call to the final test:

  • Booking: tell us the flash count, the model and serial number from the rating plate if you can read it safely, and what you have already tried. We book same-day where we can. During a cold snap the schedule fills quickly, and we tell you honestly when the next opening is rather than promising an arrival window we cannot keep.
  • Safety first: on arrival the technician checks for gas odour around the furnace and piping and takes a carbon monoxide reading at the appliance and in the living space before anything else.
  • Fault history: we read the status light and, where the control stores it, the recent fault history, so the diagnosis is based on what the furnace has been doing, not on a single cycle after a reset.
  • Airflow measurement: we measure external static pressure across the furnace with a manometer and compare the temperature rise with the range printed on the rating plate. Those two readings tell us whether the restriction is in the filter, the coil, the supply side or the return side.
  • Blower tests: motor amperage, capacitor condition on motors that use one, speed setting and the condition of the blower wheel.
  • Gas side: a licensed gas fitter checks inlet and manifold gas pressure and inspects burners and flame, so we know the furnace is not firing harder than it should.
  • Safeties: we confirm the limit switch opens and closes as designed. We never bypass it, and we inspect the heat exchanger for signs of overheating damage.
  • Written quote: before any work beyond diagnosis, you get a written quote describing the cause we found, the repair we recommend and any alternatives. Nothing is replaced without your approval.
  • Repair and proof: after the repair we run a full heating cycle, confirm the limit stays closed, repeat the airflow readings and walk you through them so you can see the fault is fixed.

Should you repair or replace a Napoleon furnace that keeps tripping the limit?

Most code 6 calls end in a repair, not a replacement. A filter habit, a blocked return, a blower component or a duct correction fixes the large majority of limit trips, and none of that is a reason to retire a furnace that is otherwise sound. Some blower parts are among the more expensive repairs on a gas furnace, but they are still usually worth doing on a unit with plenty of life left.

Replacement becomes a fair conversation when several of these line up: the furnace is near the end of its expected service life, the heat exchanger shows cracking or heat damage from years of running hot, replacement parts for that model generation are hard to source, or the house has changed so much since installation that the furnace and ducts no longer match. A cracked heat exchanger is the one finding that settles the question, because it is a carbon monoxide risk and is not something we patch.

If you are replacing, the limit problem has to be solved as part of the job. A new furnace connected to the same undersized or crushed return will trip its limit too. A correct replacement starts with a heat-loss calculation, checks the existing duct system against the new furnace’s airflow needs, and corrects the ducts where they fall short. It is also the right moment to look at dual fuel: a heat pump that carries the home through our mild, wet months, paired with a new gas furnace kept as backup for cold snaps.

The in-home estimate for a replacement or new installation is free. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.

Whatever you decide, this is what you should see in writing before work starts:

  • The cause we found for the 6 flashes code, in plain words, with the readings that support it.
  • For a repair: the parts being replaced and whether any duct or filter changes are recommended alongside them.
  • For a replacement: the furnace brand and model family, the sizing basis, any duct modifications, the gas permit, and removal of the old unit.
  • Warranty coverage as the manufacturer publishes it for your model, plus our own workmanship terms, written out rather than described verbally.

Napoleon furnace error code 6 flashes service near you in Greater Vancouver

BC Wide is based in Burnaby and has serviced gas furnaces across Metro Vancouver since 1999. We cover Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock varies a lot across that area, and it changes how a limit-trip fault usually turns up.

In older Vancouver, Burnaby and New Westminster houses, we often find furnaces that have been replaced while the original ductwork stayed, sometimes with a basement suite or renovation tied into ducts that were never resized. Returns in these homes tend to be small for the furnace now serving them, which is a classic recipe for limit trips.

In Surrey, Langley, Delta and Coquitlam, many homes are larger detached houses and townhouses with long duct runs to upstairs bedrooms and furnaces tucked into closets or garages. Filter access can be awkward in tight closets, so filters get forgotten, and furnaces in garages can have intake and exhaust terminals close to fences or landscaping that collect leaves.

On the North Shore, damp hillside lots and heavy autumn leaf fall mean we check outside terminals and condensate lines carefully, even though they are not the usual cause of this particular code. In Richmond and in townhouse and strata buildings across the region, furnaces are often in compact mechanical closets where clearances and return-air paths are tight, and any change to the venting or gas line can involve strata approval as well as a permit.

Our mild, wet coastal climate also plays a part. Furnaces here run long, gentle cycles for much of the year, so a slowly clogging filter or a dusty blower wheel can go unnoticed through autumn and then show up as repeated limit trips during the first real cold snap, exactly when everyone wants service at once.

Napoleon is one of the furnace brands we service, alongside Lennox, Carrier, Bryant, Trane, Goodman, Amana, Rheem, York, KeepRite and Daikin. We are an independent contractor, not a dealer or warranty centre for any of them, which means we diagnose and recommend based on what we measure, not on what we are selling.

Why Greater Vancouver homeowners call BC Wide for Napoleon furnace lockouts

BC Wide Home Services Ltd is an independent contractor licensed by Technical Safety BC under licence LGA0090068, with Class B gas licence CGA0028029. Gas work on your furnace is done by our own licensed gas fitters, and any work that needs a permit is permitted and inspected the way BC regulations require.

We quote in writing before any work beyond diagnosis, we explain the readings that led to our recommendation, and we tell you plainly when a repair makes sense and when it does not. If the honest answer is that your furnace needs a new filter and a cleared return grille, that is what we will tell you.

Gas and carbon monoxide safety comes before any troubleshooting. If you smell gas, which usually has a rotten-egg odour, or your carbon monoxide alarm sounds, do not reset the furnace, do not operate light switches or appliances, leave the house with everyone in it, and call FortisBC or 911 from outside. Do not go back in until you are told it is safe. Every home with a gas furnace should have working carbon monoxide alarms near the sleeping areas and on each level, tested regularly.

For Napoleon furnace error code 6 flashes service anywhere in Greater Vancouver, call BC Wide at (604) 473-9690.

More questions homeowners ask

What does Napoleon furnace error code 6 flashes mean?

It means the high-limit switch opened repeatedly during a single call for heat, so the furnace is reporting a persistent overheating or airflow problem rather than a one-time trip. Confirm against the manual for your unit, since control boards vary between model generations. The most common causes are a dirty filter, blocked registers or returns, a blower problem or restrictive ductwork.

Can I reset a Napoleon furnace showing 6 flashes?

Only if your owner manual allows it, and only once. Replace a dirty filter and open all registers first, then switch the power off, wait a minute and switch it back on. If 6 flashes returns, leave the furnace off and call a licensed technician, because repeated resets make the furnace run hot again and can hide a safety problem.

Is it safe to run my Napoleon furnace with code 6?

Not repeatedly. The limit switch is doing its job by shutting the burners off, but cycling the furnace in and out of overheating stresses the heat exchanger, and a cracked heat exchanger is a carbon monoxide risk. If the code comes back after one reset with a clean filter, keep the furnace off until it has been diagnosed.

Will a new filter fix Napoleon furnace error code 6?

Often it does, because a clogged filter is the most common cause of limit trips. If the code returns with a clean filter of the correct size and every register and return open, the restriction is somewhere else, usually the blower, the indoor coil or the ductwork. That needs airflow measurements by a technician.

How much does it cost to diagnose a Napoleon furnace code 6?

Diagnostic service calls are $189.00, and you receive a written quote before any work beyond diagnosis. If the diagnosis leads to a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. The in-home estimate for a replacement is free.

Is there Napoleon furnace error code 6 repair near me in Greater Vancouver?

Yes. BC Wide services Napoleon furnaces in Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We book same-day where we can and tell you honestly when that is not possible. Call (604) 473-9690.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a furnace be serviced?
Annual servicing is recommended for gas furnaces, ideally before the start of the heating season in September or October. Service includes burner cleaning, heat exchanger inspection, ignition check, blower motor cleaning, gas pressure adjustment and a full safety test for carbon-monoxide leaks.
How long does a furnace last in Vancouver's climate?
High-efficiency gas furnaces typically last 15–20 years with annual maintenance. Vancouver's mild climate means lower run-times than colder Canadian cities, which extends life — but salt-air corrosion near the coast and high humidity can shorten it.
Why is my furnace blowing cold air?
Common causes are a thermostat set to "on" instead of "auto", a tripped flame sensor, a clogged condensate drain shutting down a high-efficiency unit, low gas pressure, or a failed ignitor. Most are repairable in a single service visit.
How much does a new furnace cost in Vancouver?
A typical residential high-efficiency gas furnace in Metro Vancouver costs $4,500–$8,500 installed depending on size, brand and venting requirements. Variable-speed and modulating models are at the upper end.
What is the most reliable furnace brand?
In our experience servicing Vancouver homes since 1999, Carrier, Lennox, Bryant and York have produced the most reliable mid-to-high-efficiency furnaces with the best parts availability. Goodman and Rheem offer strong value at lower price points.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote