On a Napoleon furnace, High-heat LED flashing means the furnace has been asked for high-fire heat but the high-stage pressure switch has not closed, so the control keeps the burners on low fire. The usual causes are a restricted vent or intake, condensate backing up toward the switch, an inducer that is weak at high speed, or a failed switch. Check the outdoor pipes and the condensate drain, then call (604) 473-9690. Confirm the code against the manual for your unit.
If your Napoleon furnace is showing High-heat LED flashing (High heat called, high-pressure switch not closed), here’s exactly what it means and what to do. This guide is part of our full Napoleon furnace error code list.
Severity: Needs attention.
What High-heat LED flashing means on a Napoleon furnace
The furnace is being asked for high-fire heat but the high-stage pressure switch has not closed, so the control will not advance to high heat. The furnace may continue on low fire.
Common causes
- Restricted vent or intake limiting high-fire draft
- Condensate blockage affecting the pressure switch
- Weak inducer at high stage
- Faulty high-pressure switch
What you can safely check first
- Check outdoor vent and intake pipes for any blockage
- Confirm the condensate drain is clear
- Do not open or adjust the pressure switch yourself
- Call a licensed technician if high heat will not engage
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Napoleon furnace usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver furnaces since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Napoleon furnace repair across Greater Vancouver
If a Napoleon furnace showing High-heat LED flashing won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast furnace repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Napoleon furnace codes
- Napoleon furnace LED on (steady) — Normal operation
- Napoleon furnace LED off — No power or control hardware fault
- Napoleon furnace 1 flash — High limit switch open
- Napoleon furnace 2 flashes — Pressure switch open with inducer on
- Napoleon furnace 3 flashes — Pressure switch closed with inducer off
- Napoleon furnace 4 flashes — Ignition lockout (1-hour lockout)
Frequently asked questions
Is High-heat LED flashing on a Napoleon furnace serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Napoleon furnaces 7 days a week across Greater Vancouver.
How do I reset a Napoleon furnace after High-heat LED flashing?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Napoleon furnace error code high heat LED flashing: what it means for you
In plain terms, your furnace is running in a reduced mode. A two-stage Napoleon furnace has a low fire for mild weather and a high fire for cold days. When the thermostat or the control board asks for high fire, the inducer motor speeds up to pull more combustion air through the heat exchanger and push more flue gas out through the vent. A pressure switch watches that draft through a small rubber sensing hose. If the high-stage switch does not confirm the stronger draft, the control will not open the gas valve to high fire and flashes this light instead. That is the meaning this page gives for the code; confirm it against the manual for your unit, because control boards and flash patterns can differ between model generations.
What it means at home: the house usually still gets warm air, just more slowly. On a mild, damp Metro Vancouver day you may hardly notice. During a cold snap the furnace can run for long stretches and never quite reach the thermostat setting. Hot water is normally unaffected, because a forced-air furnace and a water heater are separate appliances in most homes. The code is not a gas leak warning and it is not a carbon monoxide alarm. The trouble is that its most common causes are venting problems, and the vent is a safety system. That is why the page rates it as needs attention rather than something to live with until spring.
Owners tend to describe this fault in a handful of ways. If two or more of these sound familiar, the high-heat code is probably the reason:
- The furnace runs and blows warm air, but the house takes much longer to heat up than it used to.
- On cold mornings the thermostat never reaches its setting, even after hours of running.
- You hear the inducer (the small fan that starts before the burners light) speed up, then drop back, and the flame never gets bigger.
- The status light behind the small window in the lower furnace door is flashing the high-heat pattern shown in your manual.
- You hear gurgling or sloshing from inside the furnace or from the plastic drain lines, especially after a long run.
- The furnace sometimes shuts off partway through a heat call and then starts again.
- Outside, the white plastic intake or exhaust pipes are partly covered by leaves, plants, snow, ice or a nest.
Why is my Napoleon furnace stuck on low heat? Likely causes, most common first
The four causes below are listed roughly in the order we find them on Greater Vancouver service calls. For each one, the table shows what an owner can safely look at and the point where it becomes work for a licensed gas technician. Owner checks are limited to what you can see and reach without tools. Do not open the burner compartment, remove the inner panel, pull hoses off the pressure switch, or jumper or bypass anything. A bypassed pressure switch can let a furnace fire into a blocked vent, and that is how carbon monoxide gets into a house.
Before working through the table, do the basic checks once. Make sure the furnace power switch, which usually looks like a light switch on or near the furnace, is on. Make sure the gas supply valve on the pipe next to the furnace is open, with the handle running in line with the pipe. Confirm the thermostat is set to heat and is actually calling, set a few degrees above room temperature. If your owner manual describes a reset, you may do it once, exactly as the manual says. If the code comes back, stop resetting. Repeated resets do not fix a draft problem and can hide what a technician needs to see.
- Restricted vent or intake: a high-efficiency Napoleon furnace vents through plastic pipe, usually out a side wall or up through the roof. At low fire there is often enough draft to get past a partial blockage. At high fire the furnace needs more air and has to push more exhaust, and a part-blocked terminal, a long run with too many elbows, or a sagging pipe holding water can keep the high-stage switch from closing.
- Condensate backing up: condensing furnaces make a lot of water. It drains through a trap and hoses inside the cabinet. When the trap fills with debris, or the drain line outside the cabinet is blocked or frozen, water can back up into the collector box or the switch hose. Water in that path changes the pressure the switch sees, and the high stage is usually the first thing to fail.
- Weak inducer at high stage: an inducer with worn bearings, a dirty wheel or a failing motor may still produce enough draft for low fire but not for high fire. Owners often notice a change in its sound weeks before the code shows up.
- Faulty switch, hose or connection: switches do wear out, and sensing hoses can crack, harden or come loose. This is the last item on the list for a reason. Replacing the switch without first measuring draft often clears the code for a few days, then it comes back because the real cause was the vent, the drain or the inducer.
| Likely cause | What the owner may safely check | When it becomes a licensed call |
|---|---|---|
| 1. Restricted vent or intake pipe | From the ground, look at the outdoor intake and exhaust terminals. Clear leaves, snow, ice, plant growth or a nest by hand without pulling, twisting or cutting the pipes. | If the terminals are clear and the code returns, or if any pipe looks cracked, sagging, disconnected or newly rerouted. Vent work is gas-fitting work in BC. |
| 2. Condensate backing up toward the pressure switch | Follow the visible plastic drain line to the floor drain or condensate pump. Confirm water is moving, the line is not kinked, and the pump is plugged in and not overflowing. | If water is pooling inside the cabinet, the drain line runs dry while the furnace gurgles, or the pump keeps failing. Traps, collector boxes and sensing hoses sit inside the furnace. |
| 3. Inducer motor weak at high speed | Listen only. Note any new grinding, squealing, rattling or humming when the furnace starts, and tell the technician. | Always. Testing inducer speed and the draft it produces needs meters and an open cabinet. |
| 4. Faulty high-stage pressure switch, hose or connection | Nothing to check. Do not tap, adjust, blow into, disconnect or bypass the switch or its hose. | Always. The switch is tested against measured draft and replaced with the correct part only if it has actually failed. |
How our Napoleon furnace repair visit works, step by step
A high-heat pressure switch fault is a measurement problem, not a guessing problem. Here is what a correct diagnostic visit looks like, so you know what to expect and what to ask for. Diagnostic service calls are $189.00. That covers the visit, the safety checks and a diagnosis you can understand. Any repair beyond the diagnosis is quoted in writing before work starts.
- 1. The phone call. We ask what the light is doing, how the house is heating, whether anyone smells gas or has a carbon monoxide alarm sounding, and roughly how old the furnace is. If there is any sign of gas or carbon monoxide, we tell you to leave the house and call FortisBC or 911 from outside first. We book same-day where we can, depending on the schedule and where you are. We will not promise an arrival window we cannot guarantee.
- 2. Safety first on arrival. The technician checks the air around the furnace for carbon monoxide, looks at the gas line and shut-off, and walks the vent and intake run inside and out before taking the furnace apart.
- 3. Confirm the code. We read the flash pattern and match it to the documentation for your model, not to a generic chart. We note anything else the control is reporting.
- 4. Measure the draft. With a manometer connected to the pressure switch circuit, we read the draft the inducer produces at low and high stage and compare it with the setpoint printed on the switch. A multimeter confirms whether the switch contacts actually close and whether the inducer is getting the right voltage at each speed.
- 5. Trace the cause. Depending on the readings, we inspect the vent and intake for restrictions, slope and joints, flush and check the condensate trap and collector drain, look at the sensing hose and its port, and check the inducer wheel and motor.
- 6. Written quote before any work beyond diagnosis. You get a plain explanation of what failed and why, and a written quote for the fix. The parts most often involved with this code are the high-stage pressure switch, its sensing hose, the condensate trap and drain components, the inducer motor, or a section of vent pipe that needs correcting. Nothing is replaced until you approve it.
- 7. Repair and test the safeties. After the repair we run the furnace through low and high fire and confirm the high-stage switch closes. We check the high limit, the flame rollout protection and flame sensing, measure combustion and carbon monoxide in the flue, and confirm the temperature rise is within what the furnace label calls for.
- 8. Paperwork. You get a written record of what we found, what we did and what we tested. If the repair changed the venting in a way that needs a permit, we explain that and arrange it.
Should you repair or replace an older Napoleon furnace with a high heat fault?
Most of the time this code is a repair, not a reason to replace the furnace. A cleared vent, a cleaned condensate trap, a new sensing hose or a new pressure switch is ordinary service work, and a furnace that is otherwise sound will go back to running normally. An inducer motor is a bigger repair but is still often worth doing on a furnace in good condition.
Replacement becomes a fair conversation when the high-heat fault is one of several problems arriving together. These are the signs we point out to owners, without pressure:
- The furnace is getting near the end of a typical service life. The manufacture date is on the data plate inside the door, and your technician can read it with you.
- The heat exchanger shows cracks, heavy corrosion or signs of overheating. That is a safety finding, and we will show it to you.
- The same fault keeps coming back after correct repairs, or the control board, inducer and other major parts are all wearing out within a season or two.
- Parts for your model are hard to source, so a breakdown in January could leave you without heat for longer than you would like.
- Comfort problems go beyond this code: rooms that never heat evenly, ductwork that was never sized for the furnace, or no cooling in summer.
Napoleon furnace high heat LED flashing repair near me: Greater Vancouver coverage
BC Wide services gas furnaces across Greater Vancouver from our base in Burnaby. That includes Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock varies across that area, and it changes how this code tends to show up.
In older detached houses in Vancouver, Burnaby and New Westminster, many high-efficiency furnaces were added during a renovation and replaced an older chimney-vented appliance. The plastic vent then has to travel a long way to reach a side wall, sometimes with more bends than we would like. Those long runs are more sensitive to a small restriction or a sag that holds water, and the high stage notices first. In townhouse and strata complexes in Surrey, Richmond, Coquitlam and Langley, terminals often sit in narrow side yards, under decks or behind fences and planting where leaves and debris collect, and strata rules can affect where a vent may be moved. On the North Shore and in the higher parts of Coquitlam and Burnaby, wet snow and freezing nights can ice up terminals and condensate lines during cold snaps, which is exactly when owners need high fire. In low-lying parts of Richmond and Delta, the more common culprits are condensate drains and pumps in tight utility rooms.
Our wet coastal climate matters too. Condensing furnaces here run long, damp heating seasons and produce a steady flow of condensate, so drains, traps and pumps do a lot of work. Wind-blown leaves in autumn and the occasional heavy snowfall are the usual reasons a terminal is blocked when we arrive.
We are an independent contractor and service many furnace brands, not only Napoleon. Brands we service include Napoleon, Carrier, Bryant, Lennox, Trane, American Standard, Goodman, Amana, Rheem, York, Daikin and KeepRite. We service these brands; we are not a factory-authorized dealer or warranty centre for any of them.
Who can fix a Napoleon furnace high-stage pressure switch fault, and what should you get in writing?
In British Columbia, work on a gas appliance, its gas piping or its venting must be done by a licensed gas fitter working for a licensed contractor, and many alterations need a permit. BC Wide Home Services Ltd is an independent, TSBC-licensed contractor that has served Metro Vancouver since 1999, under licence LGA0090068 and Class B gas licence CGA0028029. Our furnace work is done by licensed gas fitters. Where a repair or replacement needs a permit, we pull it and the work is open to inspection.
Because we are independent and not a Napoleon warranty centre, check whether your furnace is still under manufacturer coverage before any parts are replaced. If you are not sure, keep your original installation paperwork handy. We can tell you what we find, and you or the original installer can then follow the manufacturer’s warranty process.
Whoever you hire, a proper job for this code should leave you with the following in writing:
- The code as it was read on the day, and what it means for your specific model.
- The draft readings at low and high stage, and whether the pressure switch closed at each.
- The cause that was found, whether vent, condensate, inducer or switch, in plain words.
- A written quote approved by you before any work beyond the diagnosis.
- The parts replaced, and confirmation that high fire, the safety controls and combustion were tested afterwards.
- Whether a permit was needed, and if so, its status.
More questions homeowners ask
What does high heat LED flashing mean on a Napoleon furnace?
It means the furnace was asked for high-fire heat but the high-stage pressure switch did not close, so the control holds the furnace on low fire. The furnace may keep heating on low, just more slowly. Confirm the meaning against the manual for your unit, because flash patterns can vary between model generations.
Can I reset a Napoleon furnace showing high heat LED flashing?
Only if your owner manual describes a reset, and only once. First check that the outdoor vent and intake terminals are clear and the condensate drain is flowing. If the code comes back after one reset, stop and call a licensed technician, because repeated resets do not fix a draft problem and can hide a safety issue.
Is it safe to run my Napoleon furnace on low heat only?
For a short time, if there is no gas smell, no carbon monoxide alarm and the furnace is not shutting off repeatedly, running on low fire is generally acceptable while you arrange service. The concern is the cause rather than the low-fire mode, since a restricted vent is a safety system problem. If you smell gas or a carbon monoxide alarm sounds, leave the house and call FortisBC or 911 from outside.
How much does it cost to diagnose a Napoleon furnace high heat code?
Diagnostic service calls are $189.00. The cost of a repair depends on what we find, whether that is a vent restriction, a condensate problem, an inducer or a pressure switch, and you get a written quote before any work beyond the diagnosis. If you decide to replace the furnace through BC Wide instead, the $189.00 diagnostic charge is waived and taken off the installation.
Can a clogged condensate drain cause a Napoleon furnace high heat error?
Yes, it is one of the most common causes. When the condensate trap or drain backs up, water can reach the collector box or the pressure switch hose and change the pressure the switch reads, and the high stage usually fails first. You can check the visible drain line and pump, but clearing the trap and hoses inside the cabinet is a job for a technician.
Do you repair Napoleon furnace error codes same day in Greater Vancouver?
Same-day where we can, depending on the day’s schedule and where you are in Greater Vancouver, but we never promise a guaranteed arrival window. Call (604) 473-9690 and tell us what the light is doing and how the house is heating. If there is any gas smell or a carbon monoxide alarm, leave the house and call FortisBC or 911 from outside first.
- Lochinvar Boiler Code E08 — Heat Exchanger Limit | BC Wide
- Lochinvar Boiler Code E09 — Auxiliary Limit | BC Wide
- Lochinvar Boiler Code E11 — No Flame Running (Flame Fail) | BC Wide
- Lochinvar Boiler Code E12 — No Flame Ignition (Ignition Failure) | BC Wide
- Lochinvar Boiler Code E13 — Flue Temperature Limit | BC Wide
- Lochinvar Boiler Code E15 — Manual Reset High Limit | BC Wide
- Lochinvar Boiler Code E18 — Outlet Sensor Differential | BC Wide
- Lochinvar Boiler Code E19 — Flue Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E21 — Outlet Sensor Open/Short | BC Wide
- Lochinvar Boiler Code E22 — Inlet Sensor Open | BC Wide
Frequently asked questions
How often should a furnace be serviced?
How long does a furnace last in Vancouver's climate?
Why is my furnace blowing cold air?
How much does a new furnace cost in Vancouver?
What is the most reliable furnace brand?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.