NTI boiler error code E 00 means the control saw a flame signal before the ignition sequence began, so it locked the boiler out for safety (confirm against the manual for your unit). Expect no heat and, on a combi model, no hot water. Reset once only if your manual allows it. If E 00 comes back, or you smell gas, stop there: the usual causes are a gas valve that is not closing fully or a flame-sensing fault, and both need a licensed gas fitter. Call (604) 473-9690.
If your NTI boiler is showing E 00 (Flame detected before start (FTVN)), here’s exactly what it means and what to do. This guide is part of our full NTI boiler error code list.
Severity: Critical — likely no heat / lockout.
What E 00 means on a NTI boiler
Hard lockout (also shown E-00): the control detects a burner flame signal before the ignition sequence begins.
Common causes
- Leaking or slow-closing gas valve
- Poor combustion / flame pattern
- Flame-sensor circuit fault
- Wrong propane orifice on LP units
What you can safely check first
- If you smell gas, leave and call your gas supplier or 911 – do not reset
- Otherwise reset once; flame-sensing and gas-valve faults must be checked by a technician
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a NTI boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
NTI boiler repair across Greater Vancouver
If a NTI boiler showing E 00 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related NTI boiler codes
- NTI boiler FILL — Low water pressure
- NTI boiler ER1 — Water temperature too high (Ti/Lx)
- NTI boiler ER2 — Water sensor short circuit (Ti/Lx)
- NTI boiler ER3 — Water sensor open circuit (Ti/Lx)
- NTI boiler ER4 — 24V limit error (Ti/Lx)
- NTI boiler ER5 — DHW time-out / indirect fault (Ti/Lx)
Frequently asked questions
Is E 00 on a NTI boiler serious?
It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs NTI boilers 7 days a week across Greater Vancouver.
How do I reset a NTI boiler after E 00?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
NTI boiler error code E 00: what it means for your heat, hot water and safety
Every modern gas boiler watches its own burner through a flame-sensing circuit. Before the control opens the gas valve and lights the burner, it expects that circuit to report no flame at all. E 00 is the control telling you it saw a flame signal at a moment when there should be nothing burning, which this page describes as flame detected before start (confirm against the manual for your unit). The control has no way of knowing whether that signal is a real flame, fed by gas getting past a valve that should be shut, or a false reading from a damaged sensing circuit. So it assumes the worst case and goes into a hard lockout.
For you, that means the heat stops. Radiators, in-floor radiant loops and hydronic fin-tube convectors will cool down over the next few hours, and on a combi model the hot water taps will run cold as well. How quickly the house gets uncomfortable depends on the building: a well-sealed newer townhouse holds heat for a while, while a draughty older house on a cold, wet night cools down quickly. The lockout itself is not the danger. It is the boiler doing exactly what it was designed to do.
We treat E 00 as a priority call for one reason. If the signal is a real flame, gas is reaching the burner when the valve is supposed to be closed, and that is a gas safety problem whether or not you can smell anything. If it turns out to be a sensing fault, the boiler is still unable to trust its own safety circuit. In both cases the only honest answer comes from testing with instruments, not from resetting and hoping.
Here is how owners usually describe it when they call us:
- The display shows E 00 and the boiler will not fire, even though the thermostat is calling for heat.
- The radiators or heated floors went lukewarm, then cold, overnight.
- On a combi boiler, there is suddenly no hot water at the kitchen or shower.
- The code cleared after a reset, then came back within minutes, hours or on the next cold morning.
- The fan runs briefly, then the boiler goes quiet with the code showing.
- The code appeared right after a power outage, a service visit or a fuel conversion.
- There is a faint gas odour near the boiler. If so, stop reading and leave the house now, then call from outside as described below.
Why is my NTI boiler showing E 00? Likely causes, most common first
The order below reflects what we generally find when we open up a boiler with this lockout, starting with the most common. Your boiler may be different, and the only way to know is to measure. The owner-safe checks in the third column are things you can look at without opening the boiler or touching gas or wiring. Everything in the last column is licensed work under BC rules.
| Likely cause (most common first) | What is actually going on | What the owner can safely check | When it becomes a licensed call |
|---|---|---|---|
| 1. Gas valve leaking through or closing slowly | The valve does not seal tightly when it is told to close, so a small flame lingers after the last cycle or gas reaches the burner before the next start. The control sees flame where there should be none. | Nothing on the valve itself. Note whether you smell gas near the boiler and, if you do, leave and call from outside. | Always. Gas valve testing, adjustment and replacement are licensed gas work. |
| 2. Flame-sensing circuit fault | The flame electrode, its ceramic insulator, its lead wire or the ground path is contaminated, cracked, damp or loose, and sends the control a false flame signal. | Note whether the code tends to show up in very wet weather or after a condensate problem. Do not touch or clean the electrode. | Always. It sits inside the sealed combustion chamber and has to be tested with a meter. |
| 3. Poor combustion or flame pattern | A fouled burner, a partly blocked air intake or exhaust, or incorrect combustion settings let the flame behave badly, so it lingers, rolls or is read inconsistently. | From outside, check that the intake and exhaust terminals are clear of snow, leaves, nests and debris. Check that the visible end of the condensate drain is not kinked, blocked or frozen. | If the terminals and drain are clear and the code returns, or if anything inside the boiler needs attention. |
| 4. Wrong orifice or incomplete conversion on propane units | On a boiler converted to or from propane, the wrong orifice or settings change the way gas flows and burns, which can affect flame proving. | Confirm from your paperwork or fuel supplier whether the boiler runs on natural gas or propane, and whether it was converted recently. | Always. Fuel conversion and orifice work must be done and verified by a licensed gas fitter. |
| 5. Control board or wiring fault | The board, or wiring between the board and the sensing circuit, reports a flame signal that is not there, sometimes after a power surge or water exposure. | Note whether the code first appeared after an outage, a storm or a leak near the boiler. | Always. Control and line-voltage wiring are licensed work. |
Can I reset NTI boiler error code E 00? The owner-safe checks first
Safety comes before any reset. If you smell gas, or a carbon monoxide alarm is sounding, do not reset the boiler, do not flip light switches or unplug anything, and do not use your phone inside. Get everyone out of the house, then call FortisBC’s emergency line or 911 from outside. Carbon monoxide has no smell, so a working CO alarm on every level, and near sleeping areas, is the only warning you will get. If you do not have one, put that on the list today.
If there is no gas odour and no alarm, these are the checks a homeowner can safely make. None of them involve opening the boiler:
- Power: confirm the boiler’s service switch is on and the breaker has not tripped. Do not keep switching the power off and on as a way of resetting.
- Gas supply valve: confirm the manual shutoff handle on the gas line to the boiler is in the open position, usually with the handle in line with the pipe. If it is closed and you do not know why, leave it closed and call us.
- Thermostat: confirm it is set to heat and set above the room temperature, and that its batteries are not dead.
- Outside terminals: walk outside and look at the boiler’s intake and exhaust terminals. Clear away snow, leaves or debris by hand if you can reach them safely. Do not pull out a nest if birds are active; call us instead.
- Condensate drain: look at the visible end of the condensate line. It should not be kinked, crushed, blocked or frozen.
- One reset only, and only if the owner manual for your unit says a reset is allowed. If E 00 returns, leave the boiler locked out and call a licensed technician.
How our NTI boiler E 00 repair visit works, step by step
An E 00 lockout is diagnosed with instruments, not guesswork. Diagnostic service calls are $189.00. We offer same-day service where we can, depending on the day’s schedule and how far you are from our technicians, but we never promise a guaranteed arrival time. If you smell gas, the first call is to FortisBC or 911 from outside, not to us.
This is what the visit looks like from the moment you call (604) 473-9690:
- On the phone: we ask for the code, the model from the rating plate if you can read it, whether the boiler runs on natural gas or propane, any recent service or conversion work, and whether anyone has smelled gas. That tells the technician what to bring and how urgent the call is.
- Arrival and safety check: the technician checks for gas at the boiler and along the gas train with an electronic detector and leak solution, and checks the mechanical room air for carbon monoxide before doing anything else.
- Control history: where the model stores it, we read the lockout history so we know how often E 00 has been happening and under what conditions.
- Gas valve testing: with a manometer we check gas pressures and, critically, whether the valve holds tight when it is closed. A valve that leaks through is the most common reason a boiler sees flame before start.
- Flame-sensing circuit testing: we measure the flame signal with a meter, then inspect the electrode, its insulator, the lead and the ground connection for cracks, contamination, moisture or looseness.
- Combustion and venting: once it is safe to fire, we test the flue gas with a combustion analyzer, inspect the burner, check the intake and exhaust runs, and look at the condensate trap and drain.
- Fuel verification: on propane boilers we confirm the correct orifice and settings for the fuel actually being supplied.
- Written quote: before any work beyond diagnosis, you get a written quote describing the fault we found, the repair we recommend and the parts involved. Nothing is replaced without your approval.
- Repair and safety testing: after the repair, we test the safeties that matter for this fault, including flame proving and the lockout response, plus the high limit, low water protection and vent or pressure safeties as fitted, then run the boiler through full heating cycles and, on a combi, a hot water draw.
- Paperwork: you get a written record of what we found, what we did and anything we recommend watching.
Repair or replace an older NTI boiler with an E 00 lockout?
Most E 00 lockouts on a boiler in reasonable condition end in a repair, not a replacement. A gas valve or control board is among the more expensive parts on a condensing boiler, but replacing one is still usually the sensible choice when the heat exchanger is sound and the boiler has been reliable. We never quote a part price on this page; you get a written quote after diagnosis.
The conversation changes on an older boiler. These are the questions we work through with the owner on site:
- Heat exchanger condition: is there corrosion, leaking or heavy fouling? In Metro Vancouver the water is soft, so the problem we see in hydronic systems is sludge and corrosion in the loop, not limescale, and it can shorten a heat exchanger’s life.
- Fault history: is E 00 the first serious fault, or one of several lockouts over the last few heating seasons?
- Parts availability: are the parts for this model still readily available, or are we likely to be waiting on them during a cold spell?
- Combustion results: does the boiler burn cleanly and stably once repaired, or is it fighting other problems?
- Fit for the house: does the boiler still suit the home’s heat loss and hot water use, especially if the house has been renovated or extended?
- Venting and gas piping: would a replacement need new venting or a larger gas line? In older housing those are often what decide the scope of the job.
NTI boiler error code E 00 service near you in Greater Vancouver
We are based in Burnaby and send our own licensed gas fitters across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Every part of the region has its own boiler habits. In Vancouver and New Westminster we often find boilers squeezed into small basement mechanical rooms in older houses, where venting and gas piping were adapted over several renovations. In Burnaby, Richmond and parts of Coquitlam, many boilers serve townhouses and strata homes, where terminal locations, condensate routing and strata approval all need care. Newer homes in Surrey, Delta and Langley often run in-floor radiant heating with mixing and zoning controls that have to be checked along with the boiler. On the North Shore and the higher parts of the Tri-Cities, heavier rain and the occasional wet snowfall are more likely to block intake and exhaust terminals.
Our wet coastal climate matters for this code as well. Long stretches of rain and high humidity can be hard on condensate drains, outdoor terminals and anything electrical near them, so we always look at the outside of the system as well as the inside of the boiler.
Why owners trust us with a gas safety lockout:
- BC Wide is an independent contractor licensed by Technical Safety BC, gas contractor licence LGA0090068 and Class B gas licence CGA0028029, serving Metro Vancouver since 1999.
- Gas work is done by our own licensed gas fitters, not subcontractors.
- Permits and inspections are pulled whenever the work requires them, including gas valve, venting and replacement work.
- You get a written quote before any work beyond diagnosis, and a written record of what we found.
- We are not an authorized dealer or warranty centre for any manufacturer. If your boiler may still be under warranty, check the terms with the manufacturer or the original installer before any repair.
- Boiler brands we service include NTI, IBC, Viessmann, Navien, Lochinvar, Weil-McLain, Triangle Tube, Bosch and Rinnai.
- Replacement estimates in your home are free. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.
More questions homeowners ask
What does E 00 mean on an NTI boiler?
E 00 means the boiler control detected a flame signal before the ignition sequence began, so it went into a hard lockout (confirm against the manual for your unit). The most common causes are a gas valve that is not sealing fully and a fault in the flame-sensing circuit. Either way, the boiler will not heat until a licensed technician finds and fixes the cause.
Can I reset an NTI boiler E 00 error myself?
You can reset it once, but only if your owner manual says a reset is allowed and only if there is no gas odour and no CO alarm. If E 00 comes back, leave the boiler locked out and call a licensed gas fitter. Repeated resets ask the boiler to keep trying to start with a safety fault nobody has found yet.
Is it safe to run my NTI boiler after an E 00 code clears?
Not until the cause is known. The code may clear because the fault is intermittent, such as a gas valve that only sometimes leaks through or a sensing wire that only sometimes loses contact. Until it has been tested with a manometer, a meter and a combustion analyzer, treat the boiler as unproven and keep a working CO alarm nearby.
Why does my NTI boiler keep going back to E 00?
If the code keeps coming back, there is a real fault, not a one-time glitch. The usual causes are a gas valve that does not close tightly, a contaminated or damaged flame sensor, poor combustion, or a control or wiring problem. Each one needs instrument testing by a licensed technician to sort out.
Can you fix an NTI boiler E 00 lockout same day in Greater Vancouver?
Same-day service is available where we can, depending on the day’s schedule, your location and whether the parts are on the truck, but we never promise a guaranteed arrival window. Call (604) 473-9690 and we will give you an honest timeline. If you smell gas, leave the house and call FortisBC or 911 from outside first.
Does an E 00 code mean my NTI boiler needs replacing?
Usually not. On a boiler in reasonable condition, E 00 is normally fixed by repairing or replacing the gas valve, the flame-sensing parts or a control component. Replacement is worth discussing when the heat exchanger is corroded, the boiler has a history of lockouts, or parts are hard to get, and in-home replacement estimates are free.
- NTI Condensing Boiler Condensate Management & Common Faults: A Metro Vancouver Field Guide
- NTI Boiler Code Alert 248 — Outdoor sensor invalid (Tft/FTV) | BC Wide
- NTI Boiler Code ASC — Air switch stuck closed (Ti/Lx) | BC Wide
- NTI Boiler Code ASO — Air switch open (Ti/Lx) | BC Wide
- NTI Boiler Code b-18 — High supply temp limit (FTVN soft) | BC Wide
- NTI Boiler Code b-19 — High return temp limit (FTVN soft) | BC Wide
- NTI Boiler Code b-30 — Supply/return delta-T too high (FTVN soft) | BC Wide
- NTI Boiler Code b-52 — High flue temperature (FTVN soft) | BC Wide
- NTI Boiler Code b-65 — Blower not proven (FTVN soft) | BC Wide
- NTI Boiler Code E 02 — Failed ignition (FTVN) | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.