NTI boiler error code lockout 138 means the burner shut down because the flame signal was too low: the control could not prove a strong enough flame, so it stopped the gas for safety (confirm against the manual for your unit). Check that power is on, the gas valve is open, the thermostat is calling and the outside intake and exhaust terminals are clear, then reset once only if your manual allows it. If the lockout returns, book a licensed gas technician.
If your NTI boiler is showing Lockout 138 (Flame too low (Tft/FTV)), here’s exactly what it means and what to do. This guide is part of our full NTI boiler error code list.
Severity: Needs attention.
What Lockout 138 means on a NTI boiler
Lockout 138: the burner had to shut down because of an insufficient (too low) flame signal.
Common causes
- Blocked venting, air inlet, blower, venturi or heat exchanger
- Fouled or faulty flame sensor
- Incorrect combustion settings
What you can safely check first
- Confirm the outside vent/intake terminal is clear of debris, snow or ice
- Flame-sensor cleaning and combustion adjustment are for a technician
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a NTI boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
NTI boiler repair across Greater Vancouver
If a NTI boiler showing Lockout 138 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related NTI boiler codes
- NTI boiler FILL — Low water pressure
- NTI boiler ER1 — Water temperature too high (Ti/Lx)
- NTI boiler ER2 — Water sensor short circuit (Ti/Lx)
- NTI boiler ER3 — Water sensor open circuit (Ti/Lx)
- NTI boiler ER4 — 24V limit error (Ti/Lx)
- NTI boiler ER5 — DHW time-out / indirect fault (Ti/Lx)
Frequently asked questions
Is Lockout 138 on a NTI boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs NTI boilers 7 days a week across Greater Vancouver.
How do I reset a NTI boiler after Lockout 138?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
NTI boiler error code lockout 138: what it means for your heat and hot water
In plain terms, lockout 138 on an NTI boiler means the burner lit, or tried to, but the control board did not see a strong enough flame signal and shut the burner down. Confirm against the manual for your unit, but that is the meaning this page works from. The board reads the flame through a sensor that sits in the flame itself. A small electrical current passes through the flame to that sensor, and the strength of that current tells the board the flame is real and stable. When the reading is weak, the board cannot prove the flame is healthy, and its job is to stop the gas rather than guess. A lockout is the board refusing to keep trying until someone deals with the cause.
What that means for you depends on how your boiler is set up. If it heats the house only, the radiators, baseboard convectors or in-floor loops slowly go cool and the house drifts down over a few hours. If it is a combi boiler or it feeds an indirect hot-water tank, your hot water fades too, sometimes before you notice the heat is gone. The lockout itself is not dangerous; it is the safety system doing exactly what it was designed to do. The cause behind a weak flame can matter, though: a starved or unstable flame burns poorly, and poor combustion is where carbon monoxide comes from. That is why this code deserves a proper diagnosis rather than a habit of resetting.
Here is how homeowners usually describe the problem when they call us about this code:
- The display shows lockout 138 and the burner will not stay lit
- Radiators or in-floor heat are lukewarm or cold even though the thermostat is calling for heat
- Hot water runs warm and then cold on a combi or indirect-tank system
- The fan starts, the ignition sequence runs, the burner lights for a moment and then everything shuts down
- A reset brings heat back for a day or two, then the same lockout comes back
- The fault seems to show up more on windy or very wet days, or after heavy leaf fall
- There is gurgling from the condensate line, or water where there should not be any near the boiler
- The boiler is overdue for its annual service, or nobody remembers when it was last opened up
Nti boiler error code lockout 138: likely causes, most common first
A low flame signal has a short list of real causes. On the condensing boilers we see across Greater Vancouver, they turn up in roughly the order below. The point of the list is to show you which checks are yours and where the job becomes licensed gas work. Everything inside the boiler cabinet, the burner, the gas valve and the control wiring is for a licensed technician only.
1. A dirty, eroded or poorly positioned flame sensor. This is the most common cause on a boiler that has missed its annual service. Combustion residue coats the sensor rod, the ceramic insulator can crack, or the rod can shift out of the flame. Any of those weakens the signal. There is nothing for the owner to check here; the technician removes, inspects, cleans or replaces the sensor and confirms its position.
2. Restricted combustion air or exhaust. Modern NTI boilers are sealed-combustion appliances that pull air in through one pipe and push exhaust out through another. Leaves, moss, wasp nests, spider webs, snow or ice at the outside terminals choke the air supply, and a choked flame burns weak. You can safely look at the terminals from outside and clear loose debris you can reach from the ground.
3. A fouled burner, heat exchanger, blower or venturi. Over time, debris and combustion deposits build up on the burner surface and in the air path. Less air and an uneven mix produce a lazy, lifting or patchy flame. Cleaning these parts means opening the sealed combustion chamber, which is licensed work.
4. Gas supply or combustion settings that have drifted. Low gas pressure, a regulator problem, or a gas valve that has drifted out of adjustment all change the flame. This is more likely if gas work was recently done in the house or another gas appliance was added on the same line. The owner can confirm the manual gas valve is open and that other gas appliances light normally; pressure testing and combustion adjustment are for a licensed gas fitter with a combustion analyzer.
5. Condensate backing up. Condensing boilers produce water that drains through a trap. If the trap or line blocks, water can back toward the heat exchanger and disturb the flame. You can look at the visible drain line for kinks, overflow or freezing; cleaning the internal trap is technician work.
6. A poor ground or a wiring fault on the flame-sensing circuit. The flame signal depends on a clean electrical path. Loose or corroded connections weaken it even when the flame looks fine. This is electrical diagnosis inside the appliance and belongs to the technician.
| Likely cause | What the owner may safely check | What needs a licensed technician |
|---|---|---|
| Dirty or damaged flame sensor | Nothing inside the boiler; note when it was last serviced | Remove, inspect, clean or replace the sensor and confirm its position |
| Blocked intake or exhaust terminal | Look at the outside terminals; clear loose leaves, snow or nests reachable from the ground | Inspect the full vent run, screens and joints; check for sags holding water |
| Fouled burner, blower or heat exchanger | Nothing; do not open the sealed cabinet | Open the combustion chamber, clean, inspect gaskets and refractory |
| Low gas pressure or drifted settings | Confirm the manual gas valve is open and other gas appliances work | Measure gas pressure, analyze combustion, adjust to the manufacturer procedure |
| Blocked condensate trap or drain | Look for a kinked, overflowing or frozen visible drain line | Clean the internal trap, flush the line, confirm proper drainage |
| Weak ground or wiring fault | Nothing; do not touch control wiring | Test the flame-sensing circuit, grounds and connections with meters |
Can I reset an NTI boiler showing lockout 138? Owner-safe checks first
Yes, but only after the basic checks, only if your owner manual allows a reset, and only once. A reset clears the lockout and lets the boiler try to light again. It does not fix anything. If the cause is still there, the boiler will lock out again, and every forced restart is another lighting attempt on a flame the control has already said is not right. Work through these checks in order before you touch the reset:
- Power: confirm the boiler switch is on and the breaker has not tripped. Do not open the boiler cabinet or touch any wiring.
- Gas supply: confirm the manual gas valve on the pipe to the boiler is open, with the handle running in line with the pipe. If other gas appliances in the house will not light either, the problem may be the gas supply, not the boiler.
- Thermostat: confirm it is set to heat and set above the current room temperature so the boiler is actually being asked to run.
- Outside terminals: go outside and look at the intake and exhaust pipes. Clear loose leaves, snow, ice or nests by hand if you can reach them safely from the ground. Never climb a roof or a ladder to do it, and never cover or modify the terminals.
- Condensate drain: look at the visible drain tubing near the boiler. Note any kink, overflow, frozen section or water on the floor and tell the technician; do not take the trap apart.
- One reset: if your manual allows it, reset once using the method it describes, then watch. If the burner lights and stays lit, book a service visit anyway, because the cause is still there. If it locks out again, stop and call.
When lockout 138 becomes a licensed call, and how our repair visit works
It becomes a licensed call the moment the simple checks do not hold the boiler in operation, or the moment you would need to open the boiler to go further. Gas work in BC, including adjusting gas valves, testing gas pressure and opening the sealed combustion chamber, is legally restricted to licensed gas fitters. Do not bypass, jumper or disable anything, do not keep resetting, and do not let anyone without a gas licence clean the burner for you.
Safety first, every time: if you smell gas or your carbon monoxide alarm sounds, do not reset the boiler and do not operate light switches. Get everyone out of the house, then call FortisBC or 911 from outside. Make sure you have working CO alarms near the sleeping areas and on the level where the boiler sits.
Diagnostic service calls are $189.00. That covers the technician coming out, finding the real cause and explaining it to you. Here is how our visit runs, step by step:
- Booking: you call (604) 473-9690 and tell us the code, the boiler type and what you have already checked. We schedule same-day where we can; on busy cold days it may be the next available slot, and we will tell you honestly which it is.
- Arrival and history: the technician reads the lockout history on the display, asks when the boiler was last serviced and confirms what has changed recently in the house.
- Measured diagnosis: we test the flame signal with the right meter, check incoming and manifold gas pressure, and run a combustion analyzer on the flue gas so we are working from numbers, not guesses.
- Inspection of the usual suspects: flame sensor and its insulator, burner surface, blower and venturi, intake and exhaust venting from end to end, condensate trap and drain, and the grounds and connections on the sensing circuit.
- Written quote before any work beyond diagnosis: if parts or a combustion-chamber cleaning are needed, you get a written quote first. Nothing beyond diagnosis is done without your approval.
- Repair and safety testing: after the repair, we test the safeties, confirm a strong steady flame signal, verify combustion readings against the manufacturer procedure and run the boiler through full heating and hot-water cycles.
- Paperwork: you get a written record of what we found and what we did. Where a repair or change requires a permit, we pull it and arrange the inspection.
Repair or replace an older NTI boiler that keeps going into lockout?
Most lockout 138 calls end in a repair, not a replacement. A flame sensor, a combustion-chamber cleaning, a cleared vent or a corrected gas setting is a routine job, and a well-maintained condensing boiler can keep running reliably after it. The parts that move the decision toward replacement are the big ones: the heat exchanger and the control board are among the more expensive parts on a gas boiler, and a cracked or badly corroded heat exchanger is a safety issue, not just a cost one.
In Metro Vancouver our water is soft, so we rarely see limescale inside these boilers. What we do see on the water side of older hydronic systems is sludge and corrosion, especially where the system was never flushed or treated. That debris can damage pumps and heat exchangers and is worth checking whenever an older boiler is opened up.
We look at the following when you ask us whether to repair or replace:
- The condition of the heat exchanger on both the fire side and the water side
- How often the boiler has locked out over the last few seasons, and for which reasons
- Whether replacement parts for your specific unit are still readily available
- Whether the venting and gas piping meet current requirements, or would need work either way
- Whether the boiler is sized and set up correctly for the house and its hot-water demand
- Your plans for the home: staying long term, renovating, or selling soon
NTI boiler lockout 138 repair near me in Greater Vancouver: where we work and who we are
BC Wide Home Services Ltd works on boilers right across Greater Vancouver: Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock varies a lot across that area, and it shapes what we find behind this code. Older detached homes in Vancouver, Burnaby and New Westminster often have hydronic systems that started life with a cast-iron boiler and were later converted to a high-efficiency condensing unit, sometimes with venting and gas piping that deserve a second look. Townhouses and strata buildings in Richmond, Coquitlam, Surrey and Langley often have boiler terminals on tight side walls, under decks or near balconies, where leaves and wind-driven rain collect. On the North Shore and in Delta, exposed sidewall terminals take the brunt of coastal wind and wet weather.
Our climate matters too. Long wet stretches, moss and heavy autumn leaf fall make blocked intake screens and terminals a recurring cause here, and the occasional cold snap with snow can bury a low terminal overnight. In strata buildings, any work that touches venting through an exterior wall may also involve your strata council, and we can work with them on access.
Alongside NTI, we service condensing boilers and combi boilers from brands such as Navien, Bosch, Rinnai and Noritz. We are an independent contractor: we service these brands, but we are not a dealer or warranty centre for any of them.
BC Wide is a TSBC-licensed independent contractor, gas contractor licence LGA0090068 and Class B gas licence CGA0028029, serving Metro Vancouver since 1999. Gas work is done by our own licensed gas fitters. Where work requires a permit, we pull it and book the inspection. You get a written quote before any work beyond diagnosis. If you decide to replace rather than repair, the in-home estimate for the new equipment is free, and if you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. Call (604) 473-9690 to book.
More questions homeowners ask
What does NTI boiler error code lockout 138 mean?
It means the burner shut down because the flame signal was too low, so the control could not prove a healthy flame and stopped the gas for safety. Confirm the meaning against the manual for your unit. The usual causes are a dirty or damaged flame sensor, restricted combustion air or exhaust, a fouled burner, drifted gas settings, or a condensate backup.
Can I reset my NTI boiler on lockout 138?
You can reset it once, only if your owner manual allows a reset, and only after checking power, the gas valve, the thermostat and the outside terminals. If it locks out again, stop and call a licensed gas technician. Repeated resets do not fix the cause and can hide a real safety problem.
Is it safe to run my NTI boiler after a lockout 138?
If one reset brings it back and it runs normally, it is generally fine to use while you book a service visit, provided your CO alarms are working. If it keeps locking out, leave it off and call. If you smell gas or a CO alarm sounds, leave the house and call FortisBC or 911 from outside.
Why does lockout 138 keep coming back after I reset it?
Because the reset clears the code, not the cause. A flame sensor coated with residue, a partly blocked vent screen or a drifting gas setting can let the boiler light some of the time and fail at other times, especially in wind or wet weather. A technician measures the flame signal, gas pressure and combustion to find which one it is.
How much does it cost to fix NTI boiler lockout 138?
It depends on the cause, so we do not quote a repair price before diagnosis. Cleaning a flame sensor or clearing a vent is a routine job, while a heat exchanger or control board is among the more expensive parts on a gas boiler. The diagnostic visit carries our standard service-call fee, and you get a written quote before any repair work starts.
Can you fix an NTI boiler lockout 138 same-day near me in Greater Vancouver?
Same-day where we can. On busy cold days the next available slot may be the following day, and we will tell you honestly when you call (604) 473-9690. We cover Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley.
- NTI Condensing Boiler Condensate Management & Common Faults: A Metro Vancouver Field Guide
- NTI Boiler Code Alert 248 — Outdoor sensor invalid (Tft/FTV) | BC Wide
- NTI Boiler Code ASC — Air switch stuck closed (Ti/Lx) | BC Wide
- NTI Boiler Code ASO — Air switch open (Ti/Lx) | BC Wide
- NTI Boiler Code b-18 — High supply temp limit (FTVN soft) | BC Wide
- NTI Boiler Code b-19 — High return temp limit (FTVN soft) | BC Wide
- NTI Boiler Code b-30 — Supply/return delta-T too high (FTVN soft) | BC Wide
- NTI Boiler Code b-52 — High flue temperature (FTVN soft) | BC Wide
- NTI Boiler Code b-65 — Blower not proven (FTVN soft) | BC Wide
- NTI Boiler Code E 00 — Flame detected before start (FTVN) | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.