★ 4.7 Google rating · Serving Greater Vancouver since 1999
ServicesBrandsRebates ReviewsAboutContact 📞 Call (604) 473-9690

NTI FTVN Combi Boiler No Hot Water

Boilers, HVAC Troubleshooting

NTI FTVN Combi Boiler No Hot Water
Home › NTI FTVN Combi Boiler No Hot Water

NTI FTVN Combi Boiler No Hot Water

Key takeaways

  • The most common reason an NTI FTVN combi gives no hot water is that it is not detecting enough tap flow to start a hot water call, or it has locked out on low pressure, a blocked condensate drain or a venting problem.
  • If the house heating still works but taps stay cold, the fault is usually on the domestic hot water side: the flow sensor, the inlet screen, the diverter valve or the plate heat exchanger.
  • Owner-safe checks are limited to power, the breaker, the thermostat, the pressure gauge against the range printed on the label, and trying a tap at full flow. Never open the burner compartment or reset a lockout over and over.
  • Metro Vancouver water is soft, so fouling here is mostly debris and heat-driven deposits, not heavy limescale; cold incoming winter water also makes lukewarm complaints more common in January.
  • Any work on the gas valve, burner, igniter, flame sensor, venting or sealed combustion components is licensed gas work in BC. BC Wide is an independent TSBC-licensed contractor that services this family and can often attend same-day where the schedule allows.

If your NTI FTVN combi boiler is giving you no hot water, or the water runs lukewarm or goes cold halfway through a shower, the most likely cause is that the boiler is not seeing enough water flow to start a hot water call, or it has locked itself out because of low system pressure, a blocked condensate drain or a venting problem. Before you call anyone, confirm the boiler has power, look at the pressure gauge and compare it with the normal range printed on the boiler label, and note whether the radiators or in-floor heat still warm up. If the hot water is still missing after those checks, or the display is showing a lockout, the next step is a TSBC-licensed gas technician. BC Wide Home Services is an independent licensed contractor that services the FTVN family across Metro Vancouver, and we can often attend same-day where our schedule allows at (604) 473-9690.

Why does an NTI FTVN combi boiler suddenly stop making hot water?

A combi boiler like the FTVN does two jobs with one burner: it heats the water that circulates through your radiators, baseboard convectors or in-floor tubing, and it heats your domestic hot water on demand as it passes through the appliance. There is no storage tank. The boiler only fires for hot water when it senses that a tap or shower has been opened and water is moving through its domestic side fast enough to count as a real demand.

That design explains most no-hot-water calls. If the flow through the domestic side drops below the activation threshold the manufacturer set, the boiler simply never starts a hot water cycle, even though nothing is broken in the burner. A partly closed shut-off valve, a clogged inlet screen, a low-flow showerhead or a thermostatic mixing valve that is throttling the flow can all do this. The boiler also gives hot water priority by switching its internal diverting arrangement away from the heating loop, so a diverter that sticks can send all the heat to your radiators while the taps stay cold.

The second big group of causes is a safety lockout. The FTVN is a sealed combustion, condensing appliance, which means it watches its own system pressure, flame, condensate drainage and venting. If any of those drifts out of range, the control stops the burner and holds it off. A lockout stops both heating and hot water, which is why checking whether the house heat still works is such a useful first clue. The display will usually indicate a fault, but the meaning of any specific code belongs in the installation manual for your exact unit, not in a guess.

What can I safely check myself before calling a technician?

These checks are all outside the sealed cabinet and do not involve gas, venting or wiring. They solve a surprising number of calls, and even when they do not, what you notice helps the technician arrive with the right parts.

  • Power: confirm the boiler’s service switch is on and the breaker feeding it has not tripped. A blank display usually means no power rather than a failed boiler. Reset a tripped breaker once only; if it trips again, leave it off and call.
  • Pressure gauge: read the gauge on the boiler or the nearby piping and compare it with the normal operating range printed on the boiler label or in the owner’s manual. A reading below that range can cause a lockout. Do not add water yourself unless your installer has shown you how and the manual allows it; repeated pressure loss points to a leak, a failing relief valve or an expansion tank problem that needs a technician.
  • Heating versus hot water: turn the thermostat up a few degrees. If the radiators or floor warm up but the taps stay cold, the problem is almost certainly on the domestic hot water side. If nothing heats at all, suspect a lockout, gas supply or power issue.
  • Tap flow: open one hot tap fully, ideally a bathtub spout, which usually flows more than a shower. If the tub gets hot but the shower does not, the shower valve or low-flow head may be below the boiler’s activation flow.
  • Hot water set point: check that the domestic hot water temperature on the display has not been turned down, for example by a child, a tenant or a recent power interruption.
  • Other gas appliances: if a gas range, fireplace or dryer went in recently, note it. An undersized gas line can starve the boiler when several appliances run together.
  • Condensate line and vent terminal: look without touching anything inside the cabinet. Note whether the plastic condensate tube is kinked, disconnected or dripping, and whether the outdoor vent and air intake terminals are blocked by leaves, a bird nest or landscaping.

What does each hot water symptom usually point to?

Every call is diagnosed on site, but the pattern of the symptom narrows the list quickly. This is the order we typically work through on an FTVN combi with a hot water complaint.

What you noticeWhat it usually turns out to beSafe for the owner to checkNeeds a licensed technician
No hot water, heating still worksFlow sensor not detecting demand, clogged domestic inlet screen, sticking diverter, fouled plate heat exchangerTry a tub tap at full flow; confirm hot water set pointCleaning or replacing the screen, sensor, diverter or heat exchanger inside the cabinet
No hot water and no heatSafety lockout on pressure, flame, condensate or venting; loss of power; gas supply interruptedPower switch, breaker, pressure gauge against the label rangeDiagnosing and clearing the lockout; any gas, burner or vent work
Lukewarm water at every tapSet point too low, flow above what the boiler can heat in cold weather, fouled heat exchanger, mixing valve set lowSet point on the display; run one tap at a timeCombustion check, heat exchanger service, mixing valve adjustment
Hot then cold mid-showerFlow dropping below the activation threshold, flame dropping out, gas pressure sag when other appliances runTry a different showerhead or the tub; note whether other gas appliances were onGas pressure testing, flame sensor and igniter service, condensate trap cleaning
Hot water only at high flowLow-flow fixtures or a pressure-balancing shower valve restricting flowCompare flow at different fixturesFixture-side adjustments are arranged separately; boiler settings by a technician
Gurgling, then lockoutBlocked condensate trap or drain line backing up into the applianceLook for a kinked or disconnected condensate tubeClearing the trap and drain, checking any condensate pump

Why does the water go lukewarm or cold in the middle of a shower?

The classic mid-shower cold spell on a combi happens when flow drops below the activation threshold. Many modern showerheads are designed to use little water, and when someone lowers the handle toward warm, a pressure-balancing valve can cut the hot side flow further. The boiler reads that as the tap closing and shuts the burner off, then a few seconds later the flow picks up and it relights. The result is a hot, cold, hot pattern that feels like a failing boiler but is really a fixture and flow mismatch.

If the cold spell happens only when the dryer, range or a fireplace is running, suspect gas supply. A combi fires hard during a hot water call, and in older Metro Vancouver houses where appliances were added one at a time, the gas piping was not always resized to match. When supply pressure sags, the flame can become unstable and the boiler drops out. Only a licensed gas fitter should measure gas pressure or change piping.

Lukewarm water that never gets properly hot is usually about capacity or fouling. Every combi has a manufacturer-published domestic hot water capacity that falls as the incoming water gets colder; check the rating plate and the installation manual for your exact unit. Running two showers at once, or a shower and a dishwasher, can ask for more than the boiler can deliver. If a single tap at moderate flow is still lukewarm, the plate heat exchanger or the combustion setup needs a look.

What do technicians usually find on FTVN combis in Lower Mainland homes?

In Metro Vancouver, the FTVN family is most often found in townhouses, half-duplexes and detached houses where an older atmospheric boiler and a separate tank water heater were replaced with one wall-hung condensing combi to free up space. It is usually side-wall vented with plastic venting, piped to radiators, baseboard convectors or in-floor tubing, and the condensate is run to a floor drain or a small condensate pump. In houses with a basement suite, one combi often serves both floors, and simultaneous showers upstairs and down are a common source of lukewarm complaints.

On service calls for no hot water, the findings we see most often are a domestic inlet screen clogged with grit, particularly after municipal water main work stirs up the lines; a sticking diverter; a flame sensor or igniter that needs cleaning or replacement; a condensate trap partly blocked with residue; and a vent or air intake terminal obstructed by leaves, spider webs or a shrub that has grown over it. On the heating side, sludge and corrosion products in older radiator systems can foul the boiler, drag pressure down and trigger lockouts that take the hot water with them.

None of these are exotic, but most of them are inside the sealed cabinet or involve the combustion path, which puts them in licensed territory. A thorough visit usually covers a combustion analysis, the condensate path, venting, the domestic side screens and sensors, and system pressure, so the root cause is found rather than the symptom reset.

How do Metro Vancouver’s soft water and wet climate affect a combi boiler?

Metro Vancouver’s municipal water is soft, so the heavy limescale that clogs combis in hard-water regions is not the usual story here. Fouling of the domestic plate heat exchanger still happens, but it tends to come from debris in the supply and modest heat-driven mineral deposits, so descaling is a maintenance item rather than a constant fight. On the heating loop, the local problem is sludge and corrosion in older systems, not scale, which is why a proper flush, filtration and correct water treatment matter on retrofits.

Our incoming water also gets noticeably colder in winter. A combi has to raise that water further to reach the same shower temperature, so a boiler that felt fine in September can feel lukewarm in January at the same flow. That is often a sizing or expectation issue rather than a fault, and a technician can confirm it by measuring temperatures and flow.

The wet coastal climate matters for venting and condensate. Wind-driven rain, leaf fall and moss can affect side-wall terminals, and a condensate line run outdoors can freeze during a rare cold snap. In strata townhouses, vent terminals are sometimes near decks, fences or neighbouring windows; any change to venting location must follow the installation manual and code, and owners should check their strata bylaws with council before arranging exterior work.

When does no hot water become a licensed, same-day call?

Stop and call a licensed gas technician once the owner-safe checks are done and the boiler still will not produce hot water, or sooner if any of the following apply. In BC, gas work, work on sealed combustion appliances and most electrical work are legally restricted to licensed trades. A homeowner may check power, the breaker, the thermostat, the display settings, the pressure gauge and the outside of the vent and condensate line. Everything else is ours to do.

  • The display shows a lockout that returns after a single reset. Resetting over and over can mask a combustion or venting fault.
  • Pressure keeps dropping, or the relief valve is dripping or discharging.
  • You hear gurgling, see water under the boiler, or notice the condensate line backing up.
  • The boiler cycles on and off loudly, rumbles, or the flame sounds unstable.
  • There is soot, scorching or discolouration near the cabinet or vent.
  • You have no heat and no hot water in cold weather, or someone in the home is elderly, very young or unwell.
  • You smell gas, or a carbon monoxide alarm sounds. Leave first, then call from outside.

Should I repair or replace an FTVN combi that keeps losing hot water?

Most no-hot-water calls on this family end in a repair, not a replacement. Sensors, screens, igniters, diverter components and condensate parts are serviceable, and a well-maintained condensing combi can give many years of service. The decision to replace comes down to a handful of factors: the condition of the main heat exchanger, whether parts for your unit are still readily available, how often the boiler has needed attention in recent years, whether it was sized correctly for the household in the first place, and the state of the heating system it is connected to.

If the real problem is capacity, such as a growing family or a basement suite added after the boiler went in, a different setup may make more sense than repeated service. That might mean a higher-capacity combi, or a heating-only boiler with an indirect storage tank so several showers can run at once. A major component like the main heat exchanger or control board is one of the more expensive repairs on a condensing boiler, so on an older unit it is worth weighing against replacement.

Either way, ask for a written quote before any work starts. BC Wide will explain what we found, what each option involves, and what we would do in your house, and we service and install the FTVN family as an independent TSBC-licensed contractor, not as a factory-authorized dealer or warranty centre. For warranty questions, the manufacturer’s published terms and your installation paperwork are the reference.

Gas & carbon-monoxide safety: Your FTVN combi burns natural gas, so treat any combustion symptom seriously. Install carbon monoxide alarms on every level of the home and near sleeping areas, and test them regularly. If you smell gas, do not operate switches, phones or appliances inside; leave the building, then call your gas utility’s emergency line or 911 from outside. If a CO alarm sounds or people feel headachy, dizzy or nauseous, get everyone outside into fresh air and call 911. Never open the burner compartment, bypass a safety switch, try to relight a sealed combustion appliance by hand or reset a lockout repeatedly; those faults need a TSBC-licensed gas technician. BC Wide Home Services Ltd holds licences LGA0090068 and CGA0028029.

Frequently asked questions

Why is my NTI FTVN combi heating the house but not giving hot water?

When the heat works but the taps stay cold, the boiler is firing fine and the fault is on the domestic hot water side. The usual causes are a flow sensor that is not detecting the tap opening, a clogged domestic inlet screen, a sticking diverter or a fouled plate heat exchanger. Try a bathtub tap at full flow; if it is still cold, a licensed technician needs to open the cabinet.

Why does my combi boiler go hot and cold during a shower?

Most often the shower flow is dropping below the level the boiler needs to keep a hot water call going, so the burner shuts off and relights. Low-flow showerheads and pressure-balancing valves make this worse. If it only happens when other gas appliances are running, the gas supply may be undersized and needs testing by a licensed gas fitter.

Can I reset my NTI FTVN combi boiler myself?

A single reset after a power interruption is reasonable if the manual allows it. If the lockout comes back, stop, because repeated resets can hide a combustion, condensate or venting fault and can make it harder to diagnose. At that point it is a job for a TSBC-licensed gas technician.

What pressure should my FTVN combi boiler show?

The normal operating range is printed on the boiler label and in the owner’s manual for your exact unit, so compare your gauge with that rather than a general rule. A reading below the range can cause a lockout that stops both heat and hot water. If pressure keeps dropping after being topped up, there is a leak, a relief valve issue or an expansion tank problem that needs a technician.

Does soft Vancouver water mean my combi never needs descaling?

Soft water means heavy limescale is uncommon here, but the domestic heat exchanger can still collect debris and modest heat-driven deposits over time. A technician checks the inlet screen and heat exchanger during regular service and cleans them when needed. On the heating side, the bigger local issue is sludge and corrosion in older radiator systems.

Can BC Wide come the same day for a combi with no hot water?

We attend same-day where our schedule allows, and we prioritise homes with no heat and no hot water in cold weather or with vulnerable people. We cannot promise a guaranteed arrival window, but we will give you an honest time when you call (604) 473-9690. If you smell gas or a CO alarm sounds, leave the home and call 911 or your gas utility first.

Is BC Wide an authorized NTI dealer?

No. BC Wide is an independent TSBC-licensed contractor that services and installs the NTI FTVN family, not a factory-authorized dealer or warranty centre. For warranty coverage, refer to the manufacturer’s published terms and your installation documents, and we can help you gather the information you need.

BC Wide Home Services — Lower Mainland home-comfort specialists since 1999

Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians · Evening and weekend calls · Diagnostic service calls $189.00 · Free in-home estimates on replacements (the $189.00 is waived if you replace with us). Call 604-473-9690 or book a free replacement estimate.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

How often should a boiler be serviced?
Annual servicing is recommended for all residential boilers. BC Wide's annual service includes combustion analysis, heat exchanger inspection, expansion tank pressure check, condensate trap cleaning, and a full safety check. Annual maintenance is also required to keep most manufacturer warranties valid.
How much does a new boiler cost in Vancouver?
A typical residential high-efficiency gas boiler in Metro Vancouver costs $7,500–$15,000 installed, depending on size, brand, and whether the system is heating only or a combi unit that also handles hot water. BC Wide provides a free written quote with three options at different price points.
How long does a boiler last?
A well-maintained cast-iron boiler can last 25–30 years, a modern high-efficiency condensing boiler typically lasts 15–20 years, and a combi boiler 12–18 years. Annual servicing has the single biggest impact on lifespan.
My boiler is making a banging or kettling noise. Is that dangerous?
Kettling (a banging or whistling sound) is usually caused by limescale build-up on the heat exchanger and is a sign the system is overheating in localised spots. It will not always cause immediate failure but it shortens the life of the boiler and should be addressed within a few weeks.
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Yes. BC Wide is one of the few HVAC companies in the Lower Mainland with deep experience on European and high-end North American boilers including Viessmann, IBC, Baxi, Laars, Weil-McLain, NTI, Navien and Rinnai. We carry common parts in the truck.
Should I repair or replace my old boiler?
A useful rule: if the boiler is more than 15 years old and the repair cost is more than 50% of replacement, replacement is the better investment. BC Wide will give you both a repair quote and a replacement quote and let you decide.
What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote