- The boiler side of a radiant system is priced like a condensing gas boiler replacement; the tubing loops and floor build-up are priced separately after measuring.
- Radiant floors run on low water temperatures, which lets a condensing boiler condense for more of the heating season.
- New builds, basement slabs and full renovations are the easiest places to add radiant; a finished main floor with no access from below is the hardest.
- Floor area, zones, installation method, floor finish, venting, gas line capacity and condensate routing move the price most.
- In BC, all gas piping, boiler installation and venting must be done by a licensed gas fitter under a permit.
- Every figure on this page is a ballpark range, not a quote; call (604) 473-9690 or email info@bcwide.ca for a free written quote.
Installing gas-boiler radiant floor heating in a North Vancouver home is priced in two parts. The boiler side, meaning the heat source, venting, gas connection, pumps and controls, sits in the same ballpark as a condensing gas boiler replacement: roughly $7,000 to $15,000 installed, before GST. These are ballpark figures for orientation only and are not a quote; an accurate price needs a site visit. The second part is the floor itself: tubing loops, manifolds, insulation and the floor build-up that holds the tubing. That part depends so heavily on floor area, whether the house is a new build or a retrofit, and the floor finish you choose that no honest contractor can put a number on it without measuring the rooms. If the same boiler will also heat your domestic hot water as a combi unit, the boiler side moves toward the $8,000 to $14,000 and up ballpark instead. BC Wide Home Services is an independent, TSBC-licensed gas contractor (LGA0090068, CGA0028029) that has served Metro Vancouver since 1999, and this page explains what drives the number so you can read any quote with confidence.
How much does radiant floor heating cost in North Vancouver?
Think of the price as a boiler package plus a floor package. The boiler package is fairly predictable because it follows the same pattern as any condensing boiler installation: equipment, venting, near-boiler piping, controls, gas connection, permit and commissioning. The floor package is not predictable from a distance, because it scales with the square metres you heat, the number of zones, and how the tubing physically gets into the floor.
The table below gives the ballpark ranges we can responsibly publish. Line items without a number are not hidden costs; they simply vary too much from one house to the next to price without seeing the space.
| Part of the job | Ballpark range (installed, before GST) | Why it varies |
|---|---|---|
| Condensing gas boiler for radiant heating only | $7,000 to $15,000 | Boiler size from a heat-loss calculation, venting route, near-boiler piping, mixing and outdoor-reset controls, removal of old equipment |
| Gas combi boiler that heats floors and domestic hot water | $8,000 to $14,000 and up | Hot water demand, number of bathrooms, how domestic piping connects at the boiler, venting and gas supply |
| New gas line, short and accessible run | $500 to $1,500 | Distance from the meter or existing piping, open ceilings, number of fittings |
| New gas line, long or difficult run | $1,500 to $3,000 or more | Finished ceilings, several floors, exterior runs on sloped lots, meter capacity |
| Tubing loops, manifolds and zoning | Priced after measuring | Heated floor area, number of loops and zones, thermostats and floor sensors |
| Floor build-up (slab, thin pour, dry panels or joist plates) | Priced after measuring | New build versus retrofit, floor-height limits, insulation, finish flooring |
What does a gas-boiler radiant floor system include?
A radiant floor is a large, low-temperature radiator. Warm water leaves the boiler, is held at a low temperature by a mixing device or by the boiler’s own outdoor-reset control, and travels to a manifold. From the manifold, individual loops of oxygen-barrier PEX tubing run through the floor and back. The floor warms gently and radiates heat to people and furniture, so a room feels comfortable at a lower air temperature than forced air usually needs.
That low water temperature is why condensing boilers and radiant floors pair so well. A condensing boiler recovers extra heat by cooling its flue gases until the water vapour in them condenses, and that only happens when the water returning to the boiler is cool enough. Radiant floors send back cool water for most of the heating season, so the boiler spends more of its running time in its most efficient mode. Efficiency ratings are manufacturer-published; verify the figure for the specific model you are quoted.
The main components a quote should account for are:
- Boiler: the gas-fired heat source, sized from a room-by-room heat-loss calculation, not from the size of whatever was there before.
- Venting and combustion air: condensing boilers usually vent through a side wall or the roof using manufacturer-approved venting, which is often easier to route than an old chimney.
- Condensate neutralizer and drain: the condensate is mildly acidic and must be neutralized and routed to a drain.
- Circulator pumps and near-boiler piping: they move water between the boiler and the floor loops, often in a primary and secondary arrangement so each side gets the flow it needs.
- Mixing valve or outdoor-reset control: keeps floor water at a temperature the floor finish can safely handle and matches output to the weather.
- Manifolds: distribute water to each loop, with balancing valves and flow indicators on many designs.
- Tubing: oxygen-barrier PEX, laid at a spacing the designer chooses room by room.
- Thermostats and floor sensors: one per zone, with floor-temperature limits where wood or vinyl finishes are used.
- Expansion tank, air separator, pressure relief valve and fill valve: the safety and air-removal parts every closed hydronic loop needs.
What moves the price of radiant floor heating?
These are the factors that push a North Vancouver quote up or down. Most of them are only visible on site, which is why we will not quote a full system from a floor plan alone.
- New build versus retrofit: tubing tied to reinforcing mesh before a slab pour, or laid on a subfloor before finishes go down, is the simplest case. Retrofitting a finished house means lifting floors, adding a thin overpour or low-profile panels, or working from below between the joists.
- Installation method: a basement slab, a gypsum or concrete thin pour over a wood subfloor, grooved dry panels, and aluminum heat-transfer plates under the joists each carry different material and labour loads, and each changes floor height differently.
- Floor area and zones: more square metres means more tubing and more loops; more zones means more manifold ports, zone valves or pumps, thermostats and control wiring.
- Floor finish: tile and stone pass heat easily. Engineered wood, laminate and luxury vinyl can work but need lower floor temperatures and sometimes a tighter tubing layout. Thick carpet and pad slow heat transfer and may need more tubing to compensate.
- Insulation: heat that escapes down into the ground or into the ceiling below is wasted. Under-slab, slab-edge or below-joist insulation adds cost but is what makes the floor perform.
- Boiler approach: a heat-only boiler with an indirect tank for domestic hot water, a combi boiler, or tying radiant into an existing boiler that already feeds radiators each price differently.
- Venting: a short side-wall termination is the simple case. Long vent runs, roof penetrations, or terminations that must be kept away from windows, doors, decks or a neighbour’s property line add labour.
- Gas line capacity: many older homes were piped for a furnace and a tank water heater. Adding a boiler, or replacing a tank with a combi, can exceed what the existing piping or meter can deliver, which means new piping or a utility meter change.
- Condensate routing: a floor drain beside the boiler is easy; no drain nearby may mean a condensate pump and a longer drain line.
- Electrical: the boiler, pumps and zone controls need a proper circuit and control wiring, done by a licensed electrician where the work requires one.
- Access, permits and disposal: stairs, tight mechanical rooms, steep driveways, removal of old equipment, the gas permit through Technical Safety BC and any building permit from the municipality. Permit fees are set by each municipality or Technical Safety BC.
- Code upgrades: an older mechanical room may need changes to venting, combustion air, bonding or clearances before new equipment can go in.
Is radiant floor heating a good fit for my home?
Radiant floors make the most sense when the floor is already open. That is why they suit new builds, full-gut renovations, additions and basement developments where a new slab is being poured or the existing slab is being covered anyway. In those projects the floor work is an add-on to work that was happening regardless, and the comfort payoff is large.
They are a harder case as a stand-alone retrofit under a finished main floor you like. The options then are lifting the finish, raising the floor with a thin overpour or panels, or installing tubing and plates from below where the basement ceiling is open. Each works, but each adds cost that a new build never sees.
Radiant floors also respond slowly. A slab takes hours to warm and cool, so it rewards steady setpoints rather than deep night setbacks. Radiant heats only; if you want cooling, keep or add ductwork for central air conditioning. Many homes pair a radiant basement with the existing ducted gas furnace serving the upper floors.
- Strong fit: new builds, basement slabs being poured or replaced, full renovations, additions and suites where floors are open.
- Workable fit: rooms with open joists below them, or rooms where a modest rise in floor height is acceptable.
- Weak fit: a single finished room with no access from below, or an owner who mainly wants fast warm-up in rarely used rooms.
How do North Vancouver homes and weather affect a radiant install?
North Vancouver is two municipalities, the City of North Vancouver and the District of North Vancouver, and each runs its own building permits and bylaws. Gas permits for the boiler and piping go through Technical Safety BC either way. If your project also involves a secondary suite, a coach house or structural changes, confirm the rules with the right municipality before the heating is designed, because what you are allowed to build shapes where the loops can go.
Many homes here sit on sloped lots, from Lynn Valley and Upper Lonsdale to Edgemont, Canyon Heights and Deep Cove. Split-levels and houses with a daylight basement on the downhill side are common, and those lower levels are often concrete slabs that stay cool and damp through much of the year. An insulated radiant slab or overpour can change how a basement feels more than almost any other upgrade. Slopes also add cost: equipment carried down steep driveways or exterior stairs, vent terminations on tall walls, and gas lines run along high foundation walls all take more labour.
The North Shore gets more rain than much of the region, and the upper neighbourhoods run cooler than the waterfront, so heating seasons are long and moderate rather than short and severe. That suits radiant: long hours at low water temperature are exactly where a condensing boiler earns its keep. Heavy leaf fall and the occasional snow on the upper slopes also mean vent and air-intake terminations need to be placed where they can stay clear.
Many older North Vancouver houses from the post-war decades still have a hot-water boiler feeding radiators or convectors. In those homes a new condensing boiler can sometimes serve both the existing radiators and a new radiant zone, with a mixing device protecting the floor. Metro Vancouver water is soft, so the problems we find in older closed loops are sludge and corrosion, not scale; oxygen entering the system is the usual cause. Oxygen-barrier tubing, good air elimination and, on older systems, a flush and a dirt separator belong in the scope.
In Lower and Central Lonsdale, many residents live in strata buildings. If that is you, check the building’s bylaws with the strata council before planning anything that touches floors, venting or gas piping.
What should a radiant floor heating quote include?
A useful quote tells you exactly what is and is not being done. Ask for it in writing and check that it covers:
- A room-by-room heat-loss calculation and the boiler sizing that comes from it.
- The boiler type, and how domestic hot water will be handled.
- The installation method for each area, the tubing type, and the number of loops, manifolds and zones.
- Insulation under or around the tubing, and who supplies it.
- The venting route and termination location, plus the condensate neutralizer and drain route.
- Gas piping: whether the existing line is adequate, and if not, the new run.
- Mixing and outdoor-reset controls, thermostats, floor sensors and wiring.
- Pressure testing the loops before they are covered, then filling, purging and commissioning.
- Permits, removal and disposal of old equipment, and how code corrections found on site will be handled.
- Clear exclusions: concrete or gypsum pours, flooring, drywall and trim are often done by other trades.
- The contractor’s licence numbers and how equipment warranty and workmanship coverage are handled.
| Quote item | What to look for |
|---|---|
| Heat-loss calculation | Done room by room, not estimated from the old boiler size |
| Tubing | Oxygen-barrier PEX named explicitly |
| Loop pressure test | Done before any pour or flooring covers the tubing |
| Controls | Outdoor reset or mixing, plus floor sensors where finishes need them |
| Exclusions | Pours, flooring and finishing trades listed as included or excluded |
What can I do myself, and when do I need a licensed technician?
In BC, gas piping, gas appliance installation and venting must be done by a licensed gas fitter under a permit, and boiler wiring and most electrical work belongs to a licensed electrician. A homeowner cannot legally connect a boiler or extend a gas line.
What you can do: clear and prepare rooms, choose finishes with radiant in mind, coordinate trades on a renovation, and after installation, set thermostat schedules, note the reading on the boiler pressure gauge, keep outdoor vent and intake terminations clear of leaves and snow, and test your carbon monoxide alarms regularly.
Some owners on large renovations ask whether they can lay tubing themselves. Talk to your contractor first: the loops must follow a design, be pressure tested before they are covered, and be connected by the licensed installer. A layout done without that coordination can compromise the whole floor.
Call a licensed technician when:
- You smell gas, hear hissing near gas piping, or a CO alarm sounds. Leave the house first, then call from outside.
- Boiler pressure keeps dropping, or the relief valve drips or discharges.
- Floors that used to heat evenly now have cold zones, or you hear air gurgling in the piping.
- The boiler short-cycles, locks out, or shows a fault the manual does not clear.
- You are planning a renovation, basement development or addition and want radiant designed in before the floor is closed.
How do I get an exact price for my North Vancouver home?
Every range on this page is a ballpark price for orientation, not a quote. The boiler-side ranges are wide on purpose, and the floor work is not priced here at all, because floor area, construction method and finish change it too much to publish a responsible figure.
For exact pricing on your home, call BC Wide at (604) 473-9690 or email info@bcwide.ca for a free written quote. We will book a free in-home estimate, measure the rooms, check your gas supply, venting options and mechanical space, run the heat-loss numbers and give you an itemized price you can compare line by line against any other quote.
If an existing boiler fails during a cold snap, call us as well. Emergency and same-day visits happen where our schedule allows, but we will not promise an arrival time we cannot keep. BC Wide is an independent, TSBC-licensed contractor, licences LGA0090068 and CGA0028029, and not a factory-authorized dealer for any boiler brand.
Frequently asked questions
How much does radiant floor heating cost in North Vancouver?
The boiler side usually falls in the same ballpark as a condensing gas boiler replacement, roughly $7,000 to $15,000 installed before GST, and higher if a combi boiler also heats your domestic hot water. The tubing, manifolds and floor build-up are priced after measuring because they scale with floor area and construction method. All of this is a ballpark, not a quote.
Is radiant floor heating less expensive in a new build or a renovation?
It is almost always less expensive when the floor is already open, as in a new build, a new basement slab or a full renovation. Retrofitting under a finished floor adds the cost of lifting finishes, adding an overpour or panels, or working from below between the joists.
Can I add radiant floors to my existing boiler?
Sometimes. If the existing boiler is in good condition and can carry the added load, a radiant zone can often be added with a mixing device that keeps floor water at a safe low temperature. Older non-condensing boilers need protection from cool return water, so many owners replace an ageing boiler with a condensing unit at the same time.
What flooring works best over radiant heat?
Tile and stone transfer heat best. Engineered wood, laminate and luxury vinyl can work with lower floor temperatures and a floor sensor, but confirm the flooring maker approves it for radiant use. Thick carpet and pad reduce output and may need a denser tubing layout.
Do I need a permit for radiant floor heating in North Vancouver?
Yes. The gas and boiler work needs a gas permit through Technical Safety BC, filed by the licensed gas fitter, and renovation or structural work may also need a building permit from the City or the District of North Vancouver. Permit fees are set by each municipality or Technical Safety BC.
Are there rebates for radiant floor heating?
Programs for high-efficiency gas equipment change from year to year, and eligibility depends on the equipment and the program rules at the time. We check what is currently available when we prepare your quote and do not publish amounts, because they go out of date quickly.
Can radiant floors also cool my home?
No, residential radiant floors are for heating. If you want cooling, keep or add ductwork for central air conditioning, often served alongside a ducted gas furnace on the upper floors. We plan both systems so they work together.
BC Wide Home Services — Lower Mainland home-comfort specialists since 1999
Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians · Evening and weekend calls · Diagnostic service calls $189.00 · Free in-home estimates on replacements (the $189.00 is waived if you replace with us). Call 604-473-9690 or book a free replacement estimate.
Frequently asked questions
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
Are BC Wide technicians licensed and insured?
How can I book a service call?
Do you offer free estimates?
What brands do you service?
Do you offer government rebates for heat pumps?
How quickly can you replace a broken hot water tank?
Why should I choose BC Wide over other HVAC companies?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.