- The condensing gas boiler that feeds a radiant floor typically falls in a ballpark range of $7,000 to $15,000 installed in Greater Vancouver, before GST. This is a ballpark for orientation, not a quote.
- Tubing loops, manifolds, controls and floor work are priced only from a measured layout, and they swing with heated floor area, new build versus retrofit, and floor finish.
- Radiant floors run on low water temperatures, which suits a condensing boiler and keeps it condensing more of the season.
- In many Port Coquitlam split-levels and basement-entry homes, basement slabs and full renovations are where radiant makes the most sense.
- Gas piping, boiler venting and electrical connections are licensed work in BC, and permit fees are set by the municipality or Technical Safety BC.
For a Port Coquitlam home, gas-fired radiant floor heating is really two jobs priced together: the heat source and the floor. On the heat-source side, a new condensing gas boiler installed typically falls in a ballpark range of $7,000 to $15,000, or $8,000 to $14,000 and up if you choose a combi boiler that also makes your domestic hot water. These are ballpark figures for orientation only, not a quote, and an accurate price needs a site visit. The floor side, meaning the tubing loops, manifolds, controls and whatever floor work it takes to bury that tubing, has no honest one-size number, because it moves with how many square metres you heat, whether the floor is being built new or opened up in a renovation, and what finish goes on top. Radiant makes the most financial sense in new builds, basement slabs and full renovations where the floor is already coming up anyway.
How much does radiant floor heating cost in Port Coquitlam?
Start with the part that has a dependable ballpark. If you need a new heat source, a condensing gas boiler installation in Greater Vancouver typically sits in a ballpark range of $7,000 to $15,000, before GST, with complex jobs at the upper end. A gas combi boiler, which heats the floors and also makes on-demand domestic hot water, typically falls in a ballpark of $8,000 to $14,000 and up. If the boiler location needs a new gas line, a short and accessible run is usually in the $500 to $1,500 range, while a long or difficult run can reach $1,500 to $3,000 or more.
The distribution side does not get its own dollar figure on this page, and that is deliberate. Two Port Coquitlam homes with the same floor area can land far apart: one has a bare basement slab ready for new insulation and a pour, the other has finished flooring over joists and a drywalled ceiling below. We price the loops and floor work only after measuring the rooms and seeing the floor structure. The table below shows how each line item on a radiant job is actually priced.
| Line item | How it is priced | Main driver |
|---|---|---|
| Condensing gas boiler | Ballpark range given above | Boiler location, venting route, existing system |
| Combi boiler (heat plus hot water) | Ballpark range given above | Hot water demand, venting, gas supply |
| New gas line to the boiler | Ballpark range given above | Run length, access, meter capacity |
| PEX tubing loops | Measured layout after site visit | Heated floor area and heat loss per room |
| Manifolds and zoning | Measured layout after site visit | Number of rooms and thermostats |
| Mixing, pumps and controls | Designed after the heat-loss calculation | Water temperature strategy and number of zones |
| Floor work (pour, panels or plates) | Quoted per project | New build versus retrofit, floor height limits |
| Flooring and finishing trades | Usually priced by your general contractor | Tile, engineered wood or carpet choice |
What moves the price of a radiant floor system?
Of everything on a radiant quote, the floor itself is usually the biggest variable. The boiler becomes a known quantity once we see the venting route and the gas supply. The floor can be a clean open slab or a puzzle of old finishes, uneven concrete and limited headroom. These are the factors we weigh on every Port Coquitlam job:
- Heated floor area and room count: more square metres means more tubing and more loops, and more rooms usually means more zones, manifold ports and thermostats.
- New build versus retrofit: tubing fastened over insulation before a slab pour is the most efficient installation there is; working under or over existing floors adds labour and material.
- Floor finish: tile and stone move heat readily; engineered wood works within the flooring maker’s published temperature limits; thick carpet and underlay resist heat and change the design.
- Insulation under the floor: an uninsulated slab sends heat into the ground, and adding insulation in a retrofit means adding height or lifting the old slab.
- Venting: a condensing boiler vents through a side wall in plastic pipe, and if the old chimney also served a gas water heater, that appliance may need its own venting correction once the boiler leaves the chimney.
- Condensate routing: condensing boilers produce acidic condensate that needs a drain path, usually through a neutralizer; a mechanical room with no floor drain nearby costs more.
- Gas line sizing: the existing piping and meter must carry the boiler plus every other gas appliance running at the same time.
- Electrical: the boiler, circulators and zone controls need proper wiring, done by a licensed electrician.
- Permits, access, disposal and code upgrades: permit fees are set by the municipality or Technical Safety BC; tight mechanical rooms, removing an old boiler and bringing adjacent gas work up to current code all add labour.
Is radiant floor heating a good fit for Port Coquitlam homes?
Many homes here were built between the 1970s and the 1990s: split-levels and basement-entry houses in neighbourhoods such as Citadel Heights, Oxford Heights and Mary Hill, with newer detached homes and townhouses in areas like Riverwood. A lot of those houses sit on a concrete basement slab that is either cold underfoot or being finished into family space or a suite. That slab is where radiant earns its keep. If the basement is being gutted anyway, tubing can go down over new insulation with a thin topping pour or a panel system, and the upstairs can stay on the existing gas furnace until a later renovation.
Our climate is mild and wet rather than bitterly cold, so the heating load is modest but the season is long. That is the pattern radiant floors handle well: steady, low-temperature heat for months, with a slab that stays dry and comfortable underfoot through the damp shoulder seasons. Low supply-water temperatures also keep a condensing boiler in its efficient condensing mode more of the time than old high-temperature radiators would allow.
Metro Vancouver water is soft, so the long-term risk in a closed hydronic loop is not limescale. It is sludge and corrosion. Oxygen getting in through tubing without an oxygen barrier, or through repeated top-ups of fresh water, corrodes iron and steel parts and produces black magnetite sludge that clogs manifolds and boiler heat exchangers. A sound installation specifies oxygen-barrier PEX, a dirt or magnetic separator, and a proper fill and inhibitor treatment. Ask for those items by name on your quote.
Many Port Coquitlam owners live in townhouse and strata complexes. Radiant work touches floors, exterior wall penetrations for boiler venting and sometimes shared structure, so check your bylaws with your strata council before planning anything; we cannot tell you what a particular strata allows. Properties on lower ground closer to the rivers also deserve a look at slab moisture and under-slab insulation before new tubing goes down.
Which installation method suits your floor: new slab, thin pour, panels or plates?
How the tubing gets into the floor drives both cost and disruption more than any other single choice. Here is how the four common residential methods compare.
- Suits radiant well: new builds and additions, basement renovations down to the slab, and whole-floor renovations where the old flooring is coming out regardless.
- Harder to justify: finished upper bedrooms that are not otherwise being renovated, heavily carpeted rooms, and floors where added height would clash with stairs, cabinets or doors.
- Worth planning for: radiant floors heat only. If you want air conditioning later, think now about how cooling will reach those rooms.
| Method | Best suited to | Floor height impact | Relative disruption |
|---|---|---|---|
| Tubing cast into a new slab | New builds, additions, basement slabs being replaced | None beyond the planned slab | Low if planned early |
| Thin topping pour over subfloor or old slab | Full renovations where floors are already open | Adds height; door and stair transitions change | Moderate; curing time before flooring |
| Grooved panel system over the subfloor | Renovations where a wet pour is impractical | Adds some height | Moderate; no curing wait |
| Tubing with heat-transfer plates under the subfloor | Main floors above an open or unfinished ceiling | None on the finished floor | Ceiling below must be opened |
What should a written radiant heating quote include?
A radiant quote should read like a design, not a guess. If a price arrives without most of the items below, it is not yet a comparable number.
- A room-by-room heat-loss calculation, not a rule of thumb.
- A tubing layout showing loops per room, loop lengths kept within the tubing maker’s published limits, and manifold locations.
- The boiler type, condensing or combi, where it will sit, and its venting and condensate route.
- The water-temperature strategy: outdoor reset control, plus a mixing valve or injection setup if other heat emitters share the boiler.
- Zoning: how many thermostats, with floor sensors where the finish needs a temperature limit.
- Oxygen-barrier tubing, a separator, system fill and inhibitor treatment.
- Pressure testing of the tubing before it is covered, then air purging and commissioning after.
- Gas line work, electrical, permits, and removal and disposal of old equipment.
- A clear list of exclusions: concrete, flooring, drywall and finishing are often done by other trades.
- Manufacturer warranty terms as the manufacturer publishes them, and our own workmanship terms in writing.
Why does an accurate price need a site visit?
Radiant pricing depends on things nobody can see from a phone call or a photo. We need to look at the floor structure, from below where the ceiling is open, to confirm joist direction, depth and obstructions. We check the slab condition, any moisture and whether there is insulation under it. In the mechanical room we look at where a new boiler can sit, where its venting can exit the wall, and where condensate can drain.
We also check the gas meter and existing appliance load, the electrical panel’s room for new circuits, and how domestic hot water will be handled: a combi boiler, an indirect tank off the boiler, or the existing gas water heater staying in place. Access for materials matters too, especially in townhouses and homes with tight basement stairs. Once we have measured, we put the result in writing so you can compare it line by line.
What can a homeowner do, and when should you call a licensed technician?
Homeowners can do a lot of the planning: decide which rooms matter most, choose floor finishes with your flooring supplier, clear the work areas, test CO alarms, and on an existing boiler, note what the pressure gauge reads and how often the system needs topping up. That record is genuinely useful to a technician.
Everything tied to gas, venting or wiring is licensed work in BC. Gas piping, boiler installation and venting must be done by a licensed gas fitter under a permit, and new circuits must be done by a licensed electrician. Connecting tubing to the boiler and commissioning the system also belongs with a qualified hydronic installer, because a mistake shows up months later as cold zones, air noise or sludge.
Call a licensed technician right away if you smell gas (leave the house first and call from outside), if a CO alarm sounds, if an existing boiler keeps losing pressure or needs frequent top-ups, or if a zone stays cold. For no-heat calls on existing systems we offer same-day service where we can, but we will not promise an arrival window we cannot keep.
How do you get an exact radiant floor heating price for your Port Coquitlam home?
Everything on this page is a ballpark price meant to help you plan, not a quote. For exact pricing on your home, call BC Wide at (604) 473-9690 or email info@bcwide.ca for a free written quote. We will book a free in-home estimate, measure the rooms, check the floor structure, gas supply, venting route and electrical capacity, and give you a written price with the line items listed above.
BC Wide Home Services is an independent TSBC-licensed gas contractor, licences LGA0090068 and CGA0028029, serving Metro Vancouver from Burnaby since 1999. We are not a factory-authorized dealer or warranty centre for any boiler brand; we install and service the equipment that suits your home. Rebate and incentive programs for high-efficiency gas equipment change over time, so ask us at the estimate what currently applies and we will point you to the program’s own rules.
Frequently asked questions
How much does it cost to add radiant floor heating to a basement in Port Coquitlam?
If you need a new condensing gas boiler, that part typically falls in a ballpark range of $7,000 to $15,000 installed, which is a ballpark and not a quote. The basement tubing, insulation and floor work are priced only after we measure, because they depend on floor area, slab condition and whether you pour, use panels or lift the old slab. A basement already being gutted to the slab is usually the most cost-effective radiant project.
Can radiant floor heating run off my existing boiler?
Sometimes. It depends on the boiler’s capacity, its condition and the water temperature it runs at. An older boiler serving high-temperature radiators needs a mixing valve or injection setup to protect the floor, and a boiler with sludge in its system should be cleaned and treated before new loops are added. We check this at the site visit.
Is radiant floor heating worth it compared with a gas furnace?
Radiant gives even, quiet heat with warm floors and no ducts, and it pairs well with a condensing boiler. It costs more up front, responds more slowly to thermostat changes and does not cool the house. It is most worth it in new builds, basements and full renovations; many homes keep a gas furnace upstairs and add radiant where the floor is open.
Can radiant floor heating go under hardwood?
Engineered hardwood generally works over radiant when you stay within the flooring maker’s published temperature limits, usually enforced with a floor sensor. Solid hardwood needs more caution around moisture and movement. Tile and stone are the easiest finishes, and thick carpet and underlay reduce heat output.
Do I need a permit for radiant floor heating in Port Coquitlam?
Yes for the gas side: boiler installation and gas piping are done under a gas permit taken out by a licensed gas contractor. Building work such as new slabs or structural changes may also need a City of Port Coquitlam permit. Permit fees are set by the municipality or Technical Safety BC, and we include permits in our written quote.
How long does a radiant floor installation take?
The boiler side is usually a matter of days once equipment is on site. The floor side follows your renovation schedule, and a thin topping pour needs curing time before flooring goes down. We give you a realistic timeline in writing after the site visit.
Does radiant floor heating cool the house in summer?
No. Radiant floors are a heating system only. If you want air conditioning, it needs its own system, so plan for it during the renovation rather than after the floors are finished.
BC Wide Home Services — Lower Mainland home-comfort specialists since 1999
Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians · Evening and weekend calls · Diagnostic service calls $189.00 · Free in-home estimates on replacements (the $189.00 is waived if you replace with us). Call 604-473-9690 or book a free replacement estimate.
Frequently asked questions
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
Are BC Wide technicians licensed and insured?
How can I book a service call?
Do you offer free estimates?
What brands do you service?
Do you offer government rebates for heat pumps?
How quickly can you replace a broken hot water tank?
Why should I choose BC Wide over other HVAC companies?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.