Viessmann boiler error code 38 means the boiler water temperature sensor circuit is open: the control has lost the signal from that sensor, most often because of a broken sensor cable, a disconnected sensor plug or a failed sensor (confirm against the manual for your unit). Without that reading the boiler cannot safely manage heat or hot water, so expect it to stop and hold the fault. Check power, the gas valve and the thermostat only, reset once if your manual allows, then book a licensed technician at (604) 473-9690.
If your Viessmann boiler is showing 38 (Boiler water temperature sensor open circuit), here’s exactly what it means and what to do. This guide is part of our full Viessmann boiler error code list.
Severity: Needs attention.
What 38 means on a Viessmann boiler
The boiler water temperature sensor lead is broken / open circuit.
Common causes
- Broken sensor cable
- Disconnected sensor
- Faulty sensor
What you can safely check first
- No safe homeowner fix — book an engineer
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Viessmann boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Viessmann boiler repair across Greater Vancouver
If a Viessmann boiler showing 38 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Viessmann boiler codes
- Viessmann boiler F.0 — Internal / sensor fault
- Viessmann boiler F.1 — Programming unit / control fault
- Viessmann boiler F.2 — High-limit / fixed limit responded
- Viessmann boiler F.3 — Flame signal at start (premature flame)
- Viessmann boiler F.4 — No flame / flame not established
- Viessmann boiler F.4 EE — Condensate pipe frozen
Frequently asked questions
Is 38 on a Viessmann boiler serious?
It signals a fault to address; left alone it can lead to a no-heat shutdown. BC Wide repairs Viessmann boilers 7 days a week across Greater Vancouver.
How do I reset a Viessmann boiler after 38?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Viessmann boiler error code 38: what it means for your heat and hot water
In owner terms, code 38 says the boiler has gone partly blind. The control board reads the boiler water temperature sensor constantly to decide when to fire the burner, how hard to fire it and when to stop. When that sensor circuit reads as open, as if the wire had been cut, the control has no trustworthy value for how hot the water in the heat exchanger is. A boiler that cannot see its own water temperature should not fire normally, so the control will typically stop heating and hold the fault until the circuit is restored. The exact response varies by model and control generation, so confirm against the manual for your unit.
What that means day to day depends on how your system is set up. If the boiler heats radiators, baseboard convectors or in-floor radiant loops only, the house will slowly cool over the following hours. If it also makes domestic hot water, through an indirect tank or a combi design, you may lose hot water at the same time. In a strata unit or townhouse with a wall-hung boiler in a closet, the first thing most people notice is the display, followed by cold radiators or a shower that never warms up.
Code 38 is an electrical sensing fault, not a combustion fault in itself. That is mildly reassuring: on its own it does not mean there is a gas leak or a cracked heat exchanger. But it is also not a nuisance message to clear and forget. The sensor that has dropped out is part of how the boiler protects itself from overheating, and running on guesswork is exactly what the control is designed to prevent.
What owners usually notice when code 38 appears:
- The display shows 38 or a fault symbol and the boiler will not restart on its own.
- Radiators, baseboard convectors or heated floors go lukewarm, then cold.
- Hot water runs cold or only lukewarm if the boiler also heats your domestic water.
- The boiler clicks or the circulating pump runs briefly, but the burner does not light.
- The fault clears after a power cycle, then comes back within hours or days.
- The code appeared shortly after other work near the boiler, such as a closet renovation, a new thermostat or another trade working in the mechanical room.
Viessmann boiler error code 38: likely causes, most common first, and owner-safe checks
Manufacturer documentation commonly points to three causes for this code: a broken sensor cable, a disconnected sensor and a faulty sensor. The table below shows how those play out in a real basement or mechanical closet, ranked roughly by how often they turn out to be the culprit, together with two related conditions that produce the same open-circuit reading. For every row, the right-hand column is the honest answer to whether you can fix it yourself.
- Confirm the boiler has power: the service switch near the boiler is on and the breaker has not tripped. Reset a tripped breaker once only; if it trips again, leave it off and call.
- Confirm the manual gas valve to the boiler is in the open position, with the handle in line with the pipe. Do not operate or adjust any other gas valve.
- Confirm the thermostat or room control is calling for heat, is set above room temperature and has fresh batteries if it uses them.
- If your owner manual permits a reset for this fault, press reset once. If 38 returns, stop there.
- Step outside and check that the intake and exhaust terminals are clear of leaves, snow, ice or nests, and that the visible condensate drain line is not kinked or blocked. These are not the cause of code 38, but ruling them out saves time on the visit.
- Photograph the display and write down when the fault appeared, what the house was doing at the time and anything recently done near the boiler.
| Likely cause (most common first) | What it tends to look like | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Sensor cable damaged or broken | Code appears suddenly, often after work near the boiler or after something was stored against the casing | Look without touching: is anything pressing on or pinching wiring visible below the boiler? Do not open the casing | Always. Cable testing and repair happen inside the boiler with power isolated |
| 2. Sensor plug loose, disconnected or corroded | Fault comes and goes, sometimes after the boiler heats up or vibrates on start-up | Note when it happens and whether one permitted reset clears it; write it down for the technician | Always. Reseating or cleaning connectors means opening the boiler |
| 3. Sensor itself failed internally | Fault is steady and returns immediately after a single permitted reset | None beyond confirming power, gas valve position and thermostat call | Always. The sensor is tested with a meter and replaced with the correct part for the model |
| 4. Moisture or corrosion around the connector | Fault shows up in the wettest months, or there are drips or staining near the boiler | Look for water marks under the boiler or at the relief valve outlet and report them | Always. A leak near electrical connections must be found and fixed first |
| 5. Control board input or harness fault (less common) | Sensor and cable test good but the fault persists | None | Always. Board diagnosis needs model-specific testing and the correct replacement part |
Can I reset Viessmann boiler error code 38, and when is it a licensed call?
A single reset is reasonable only if your owner manual allows it for this fault. An open-circuit sensor fault is a hardware condition: if a wire is broken or the sensor has failed, pressing reset changes nothing, and the code returns as soon as the control checks the circuit again. If a reset does clear it, that is still useful information, because it points toward an intermittent connection rather than a dead sensor. Write down that it cleared and how long it stayed away, and book the visit anyway.
What you should not do: keep cycling the power, take off the front casing, unplug or reseat connectors yourself, fit a sensor bought online, or jumper the sensor terminals to fool the control. Each of those either hides the real fault or removes a protection the boiler relies on. A boiler fired without a valid water temperature reading can overheat its heat exchanger, lift the pressure relief valve or damage components that are far more expensive to replace than a sensor.
Under BC rules, gas work and most electrical work on a boiler are restricted to licensed trades. Everything in the owner-safe list above is about looking, recording and operating the normal user controls. Anything that involves removing panels, disconnecting wires, draining or refilling system water, or touching gas components is technician work.
Code 38 becomes a licensed call as soon as any of these is true:
- The code comes back after one permitted reset.
- The fault clears and returns repeatedly over a few days.
- You see water under the boiler, at the relief valve outlet or anywhere near wiring.
- The boiler bangs, rumbles or makes kettling noises before or after the fault.
- The pressure gauge reads well outside what the manual describes, or keeps rising and falling.
- There is no heat in cold weather and someone in the home is elderly, very young or unwell.
- Gas and carbon monoxide safety: if you smell gas (a sulphur or rotten-egg odour) or a carbon monoxide alarm sounds, do not touch light switches, the boiler or its controls. Get everyone out of the home, then call FortisBC’s emergency line or 911 from outside, and do not go back in until you are told it is safe. Code 38 is not a gas fault in itself, but every home with a gas boiler should have working CO alarms near sleeping areas and on the level of the appliance.
How our Viessmann boiler error code 38 repair visit works
Diagnostic service calls are $189.00. Here is what happens during that visit, step by step, so you know what a correct job looks like before anyone picks up a tool.
- 1. Booking and triage. When you call (604) 473-9690 we ask what the display shows, whether you have heat and hot water, what you have already tried and whether anyone in the home is vulnerable to the cold. We offer same-day where we can; it depends on the day’s workload and travel, and we will tell you plainly if it has to be the next available slot. We never promise a guaranteed arrival window.
- 2. Safety first on arrival. The technician checks for gas odour, confirms CO alarms are present and working, looks over the venting and condensate routing, and reads the stored fault history where the control keeps one.
- 3. Isolate and open. Power is isolated before the casing comes off. The sensor, its connector and its cable are inspected along their full run for chafing, heat damage, corrosion, moisture and loose terminals.
- 4. Measure, do not guess. The sensor is tested with a meter against the manufacturer-published values for that model, and the wiring is tested for continuity end to end. This is what separates a broken cable from a failed sensor from a control board fault.
- 5. Explain and quote in writing. You get a plain explanation of what failed and a written quote before any work beyond diagnosis. Nothing is replaced on assumption.
- 6. Repair with the correct part. Sensors are model-specific. The replacement is matched to your boiler, routed and secured so it cannot chafe again, and its connections are made clean, dry and tight.
- 7. Test the safeties and run it. The boiler is brought up through a full heating cycle. The technician confirms the control reads sensible water temperatures, the burner lights, modulates and shuts off as it should, the limit and other safeties respond, and combustion is checked where the visit warrants it.
- 8. Written record. You receive a note of what was found, what was done and anything worth watching, such as system pressure, signs of sludge in the system water or an ageing component.
Repair or replace an older Viessmann boiler after error code 38?
On its own, code 38 is rarely a reason to replace a boiler. The parts most often involved, in general terms, are the boiler water temperature sensor itself, the short cable or harness section that connects it to the control, and the connector at either end; occasionally the fault traces back to the control board input. A sensor or cable is a contained repair on a boiler that is otherwise sound, while a control board is one of the more expensive parts on any modern boiler. That spread is exactly why we test before we quote. The repair-versus-replace question only becomes real when the visit uncovers other problems, or when the boiler is old enough that faults are starting to form a pattern.
Repair usually makes sense when the boiler is within its expected service life with a record of regular maintenance, the heat exchanger is clean and dry with no heavy corrosion, parts for your model are still readily available, and this is the first significant fault in years. Replacement starts to make sense when sensor, control or ignition faults keep recurring across heating seasons, the heat exchanger is leaking or badly fouled with sludge, key parts are discontinued or hard to source, or the system no longer suits the home after a renovation changed the heat load or the family’s hot water needs.
If replacement is on the table, we will say so with reasons, not pressure. The in-home estimate for replacing or installing a boiler is free, and if you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.
Brands we service for gas boilers include Viessmann, IBC, Navien, Lochinvar, Weil-McLain and Buderus. We are an independent contractor rather than a dealer for any of them, so a recommendation is about fit for your home and the parts support available locally, not about which brand we stock.
What a replacement quote should show you in writing:
- The boiler being proposed, and any indirect hot water tank, with the reasoning for the size based on the home’s heat loss rather than the old unit’s nameplate.
- Venting and combustion-air routing, including terminal locations and clearances.
- Condensate drain routing and neutralisation where the installation needs it.
- Gas piping changes and confirmation the existing line can supply the new appliance.
- System flushing, water treatment and any strainer or dirt separator to protect the new heat exchanger from old sludge.
- Permits, inspection, removal of the old boiler, and a clear list of what is and is not included.
Viessmann boiler error code 38 service across Greater Vancouver
We cover Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock varies a great deal across that area, and it shapes what we tend to find behind a code 38. The notes below are general patterns, not rules; every house is checked on its own merits.
- Vancouver and Burnaby: plenty of older detached homes where a modern wall-hung boiler has been fitted to an established hydronic system, alongside strata buildings where boilers live in tight closets. In tight spaces, cables can get pinched when shelves, storage or doors press against the boiler.
- New Westminster and the North Shore: many older homes with cast-iron radiators and long-established piping, where sludge and corrosion in the system water are often part of the bigger picture. Homes built into slopes frequently put the boiler in a damp lower level.
- Richmond and Delta: low-lying ground and damp lower floors in some homes make moisture around electrical connectors something we look for specifically.
- Surrey and Langley: a wide range from older homes to newer subdivisions with radiant floors, with boilers often in garages or utility rooms where knocks and stored items can disturb wiring.
- Coquitlam, Port Coquitlam and Port Moody: a lot of townhouse and strata stock with wall-hung boilers in shared-wall layouts, where strata access rules and shared venting walls can affect when work can happen.
- Our mild, wet coastal climate means boilers here run through a long heating season at moderate loads, so sensors and connectors go through a great many heating cycles each year. Our water is soft, so hydronic trouble here is usually sludge and corrosion rather than limescale; code 38 is an electrical fault, but the visit is a good moment to check system water condition and pressure.
- In strata buildings, tell your property manager ahead of time if the technician needs a mechanical room, a parking-level access or a look at a shared exhaust wall.
- Why owners call us: BC Wide Home Services Ltd is an independent, Technical Safety BC licensed gas contractor (licence LGA0090068, Class B gas licence CGA0028029) serving Metro Vancouver since 1999. Diagnosis and repairs are done by our own licensed gas fitters, gas work is carried out under permit with inspection where the work requires it, and you get a written quote before any work beyond diagnosis. We are not a Viessmann dealer or warranty centre, so if your boiler is still under a manufacturer warranty, check with the company that registered it before authorising repairs. Call (604) 473-9690.
More questions homeowners ask
What does Viessmann boiler error code 38 mean?
It means the boiler water temperature sensor circuit is open, so the control is no longer getting a reading from that sensor. The usual causes are a broken sensor cable, a disconnected sensor or a failed sensor; confirm the meaning against the manual for your unit. The boiler will normally stop heating until the circuit is restored by a technician.
Can I reset Viessmann boiler error code 38 myself?
Only once, and only if your owner manual allows a reset for this fault. Because code 38 points to a wiring or sensor problem, a reset rarely fixes it, and if the code returns you should stop and book a licensed technician. Do not keep cycling power, open the casing or touch the sensor connections.
Is it safe to run my Viessmann boiler with code 38 showing?
Do not try to force it to run. The water temperature sensor is part of how the boiler protects itself from overheating, which is why the control stops on this fault. Leave it alone apart from one permitted reset, keep CO alarms working, and if you smell gas or an alarm sounds, leave the home and call FortisBC or 911 from outside.
How quickly can you fix Viessmann error code 38 in Greater Vancouver?
We offer same-day where we can, depending on the day’s workload and your location, but we never promise a guaranteed arrival window. Once on site, finding whether it is the cable, the plug, the sensor or the control is usually straightforward with the right meters. If the correct sensor for your model is not on hand, the repair may need a return visit when the part arrives.
Viessmann boiler repair near me: which areas do you cover?
BC Wide services Viessmann boilers in Vancouver, Burnaby, Surrey, Richmond, Coquitlam, Port Coquitlam, Port Moody, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed gas contractor based in Burnaby and have worked across Metro Vancouver since 1999. Call (604) 473-9690 to book.
Does Viessmann error code 38 mean my boiler needs replacing?
Usually not. A failed sensor or damaged cable is a contained repair on a boiler that is otherwise in good shape. Replacement only comes into the conversation if the visit finds bigger problems such as a leaking heat exchanger, heavy sludge damage or a pattern of recurring faults, and in that case the in-home estimate for a replacement is free.
- Vaillant Boiler Code F.85 — Flow/return sensor fitted on the same pipe | BC Wide
- Vaillant Boiler Error Codes & Repair | Greater Vancouver | BC Wide
- Viessmann Boiler Code 02 — Safety chain / burner lockout | BC Wide
- Viessmann Boiler Code 0A — Fan speed fault | BC Wide
- Viessmann Boiler Code 0B — Wind conditions / low water flow | BC Wide
- Viessmann Boiler Code 0C — Power supply / flame-after-shutdown fault | BC Wide
- Viessmann Boiler Code 0D — Reset button pressed too often | BC Wide
- Viessmann Boiler Code 0F — Service / maintenance due | BC Wide
- Viessmann Boiler Code 10 — Outdoor temperature sensor short circuit | BC Wide
- Viessmann Boiler Code 18 — Outdoor temperature sensor open circuit | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.