Viessmann boiler error code EE means the air-pressure switch or air damper flap is faulty or stuck, so the boiler locks out and will not run (confirm against the manual for your unit). Expect no heat, and no hot water if the boiler also heats your water. Check that the outside intake and exhaust terminals are clear and the visible condensate line is not blocked, reset once only if your manual allows it, then call a licensed gas technician at (604) 473-9690.
If your Viessmann boiler is showing EE (Air pressure switch / air damper fault), here’s exactly what it means and what to do. This guide is part of our full Viessmann boiler error code list.
Severity: Critical — likely no heat / lockout.
What EE means on a Viessmann boiler
The air-pressure switch or air damper flap is faulty or stuck, so the boiler will not run.
Common causes
- Stuck or faulty air pressure switch
- Air damper flap jammed
- Blocked flue / air supply
- Wiring fault
What you can safely check first
- No safe homeowner fix — book an engineer
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Viessmann boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Viessmann boiler repair across Greater Vancouver
If a Viessmann boiler showing EE won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Viessmann boiler codes
- Viessmann boiler F.0 — Internal / sensor fault
- Viessmann boiler F.1 — Programming unit / control fault
- Viessmann boiler F.2 — High-limit / fixed limit responded
- Viessmann boiler F.3 — Flame signal at start (premature flame)
- Viessmann boiler F.4 — No flame / flame not established
- Viessmann boiler F.4 EE — Condensate pipe frozen
Frequently asked questions
Is EE on a Viessmann boiler serious?
It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs Viessmann boilers 7 days a week across Greater Vancouver.
How do I reset a Viessmann boiler after EE?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Viessmann boiler error code EE: what it means for your heat, hot water and safety
In plain terms, EE tells you the boiler checked its combustion air path and did not get the confirmation it needed. As this page describes the code, the air-pressure switch or the air damper flap is faulty or stuck, so the boiler will not run (confirm against the manual for your unit). A modern sealed-combustion boiler will not light its burner until it can prove that air is moving in through the intake, across the burner and out through the vent the way it was designed to. When that proof fails, the controls stop the sequence and lock out. The lockout is the boiler protecting you, not the boiler damaging itself.
What you notice in the house depends on how your system is set up. With a heating-only boiler, the radiators, in-floor loops or fan coils slowly go cool and the thermostat keeps calling with nothing happening. If the boiler also makes your domestic hot water, either as a combi unit or by heating an indirect storage tank, the taps will run lukewarm and then cold once the stored heat is used up. A boiler sitting in EE lockout is not burning gas, so it is not producing combustion gases while it waits. The concern is the reason it locked out: if the cause is a vent or air problem, that problem matters the moment someone gets the boiler to fire again.
Here is how owners usually describe an EE call to us when they phone in. If several of these sound familiar, you are in the right place.
- The boiler display shows EE and the heating has stopped.
- Radiators or heated floors are cold even though the thermostat is calling for heat.
- Hot water ran out and is not recovering, on combi or indirect-tank systems.
- You hear the fan start, run for a moment, then stop without the burner lighting.
- The code cleared after switching the power off and on, but came back within hours or days.
- It started after a windstorm, a wet snowfall, roofing or siding work, or a new deck or fence near the vent terminals.
- The condensate line is not dripping when it normally does, or you hear gurgling from inside the boiler.
Viessmann boiler error code EE: likely causes, most common first, and what you can safely check
Only a tested diagnosis confirms the cause on your boiler, but in our experience air-proving lockouts tend to trace back to the list below, roughly in this order. The third column is what a homeowner may safely look at. Everything in the fourth column is work for a licensed gas technician.
Beyond the terminals and condensate line, there are a few more things you may confirm before you call. Make sure the boiler’s power switch and the service switch or breaker for it are on. Confirm the gas shut-off valve on the supply line to the boiler is open, with the handle running parallel to the pipe, without forcing it. Check that the thermostat is set to heat, set above the current room temperature, and has fresh batteries if it uses them. If your owner manual describes a reset procedure for a lockout, you may try it once. If EE comes back, stop there.
What not to do matters just as much. Do not keep resetting the boiler, do not open the front casing, do not unplug, bridge or jumper the air pressure switch, do not pull off the small sensing tubes, and never run the boiler with a vent section loose or removed. Repeated resets wear components and can mask a vent or air problem that matters for carbon-monoxide safety.
Gas and carbon-monoxide safety: if you smell gas, or a carbon-monoxide alarm sounds at any point, get everyone out of the house first, without operating light switches on the way, and then call FortisBC or 911 from outside. Do not go back in until you are told it is safe. Every home with a gas boiler should have working carbon-monoxide alarms near sleeping areas and on the level where the boiler sits.
| Likely cause | What is going on | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Blocked intake or exhaust terminal | Leaves, wet snow, ice, a wasp or bird nest, a stored item, or a new deck or fence near the terminals restricts air, so the switch never sees the pressure difference it expects. | From a safe spot on the ground, look at the outside terminals and clear loose leaves or snow by hand if you can reach them easily. Do not remove caps or screens. | If the terminals are clear and EE returns, or if anything at the terminal looks damaged, crushed or disconnected. |
| 2. Blocked condensate trap or drain | On a condensing boiler, condensate that cannot drain away can back up inside the appliance and disturb the air and pressure readings. | Check that the visible condensate line is not kinked, frozen or pinched, that any condensate pump is not full, and that the drain it runs to is open. | Cleaning or refilling the internal trap means opening the appliance, which is technician work. |
| 3. Sensing tube problem | The small tubes that carry pressure to the switch can crack, kink, slip off or fill with moisture, giving the switch a false reading. | None. These are inside the casing. | Always. A technician inspects, clears or replaces the tubing and re-tests. |
| 4. Sticking air damper flap | The damper or flap that controls air flow can stick with debris, corrosion or wear, so air does not move the way the controls command. | None beyond confirming the terminals are clear. | Always. The flap sits inside the sealed combustion air path. |
| 5. Faulty air pressure switch | The switch itself can fail, so it reports a fault even when airflow is actually fine. | None. | Always. A technician proves the switch with a manometer before replacing anything. |
| 6. Weak or failing combustion fan | A fan that is slowing down or wearing out may not create enough pressure difference for the switch to confirm airflow. | Note whether the fan starts, how long it runs before stopping, and any new noise, and pass that on. | Always. |
| 7. Wiring or connector fault | A loose, corroded or damaged connection between the switch, the damper and the control board interrupts the signal. | None. Do not open the control area. | Always. Electrical diagnosis on a gas appliance is licensed work. |
| 8. Vent piping fault | A sagging run that traps condensate, a separated joint, or a vent altered during a renovation can restrict flow or let flue gas escape. | Look for visible damage to exposed vent pipe without touching or adjusting the joints. | Always, and treat any suspected vent leak as a carbon-monoxide concern. |
How our Viessmann boiler error code EE repair visit works
Diagnostic service calls are $189.00. Here is what that visit covers, step by step, so you know what a correct job looks like and what you should see in writing.
- Step 1, the phone call: we ask for the code, what the boiler was doing when it stopped, whether it also heats your water, and anything that changed recently, such as roof work, snow, a renovation or a new structure near the vent. We book same-day where we can, and we will not promise an arrival window we cannot keep.
- Step 2, safety first: on arrival the technician checks for gas odour and carbon monoxide around the boiler and the vent before touching anything else.
- Step 3, read the history: the boiler’s fault history and the conditions at the time of lockout tell us whether EE is a one-off or a recurring fault, which changes where we look first.
- Step 4, follow the air path in order: outside terminals, the full vent run, the condensate trap and drain, then the sensing tubes and the air damper flap inside the appliance.
- Step 5, measure instead of guessing: we test the air pressure switch with a manometer, check combustion fan operation, and test voltage and continuity on the wiring with a meter. A part gets replaced because it failed a test, not because it is the usual suspect.
- Step 6, written quote before work: if the fix goes beyond the diagnosis, you receive a written quote describing the work and the parts in plain words before any repair starts. You decide whether to go ahead.
- Step 7, repair and prove it: after the repair we run the boiler through full heating cycles, confirm the safeties shut it down when they should, check combustion and venting, and confirm both heat and hot water.
- Step 8, the paperwork: you get a written record of what we found, what we did, and anything worth keeping an eye on.
Should you repair or replace a Viessmann boiler that keeps showing EE?
Most EE faults are repairable, and on a boiler in good overall condition a repair is usually the sensible call. The parts most often involved, in general terms, are the air pressure switch, its sensing tubes, the air damper or flap assembly, the combustion fan, wiring connectors, the condensate trap and occasionally a vent section. A control board is one of the more expensive parts on a modern boiler and is rarely the first thing at fault on an air-proving code, which is exactly why we measure before replacing it. Viessmann parts are specific to the model, so if a part has to be ordered we tell you honestly how long that may take and whether there is a safe way to keep the house comfortable in the meantime.
The repair-or-replace question changes when the boiler is older, when EE is one of several different faults in a short period, or when the inspection turns up problems beyond the air path. These are the things we weigh with you on site:
- Age and service history: an older boiler that has not been serviced regularly is more likely to have several worn parts at once, not just the one that triggered EE.
- Heat exchanger and system water: Metro Vancouver water is soft, so hydronic trouble here is sludge and corrosion rather than limescale. Heavy sludge or corrosion in the heat exchanger changes the long-term picture.
- Parts availability: if key parts for your model are hard to source, the next breakdown may leave you without heat for longer.
- Venting: if the existing vent route does not meet current requirements and has to be redone anyway, that cost belongs in the comparison.
- How you use the home: a renovation, an added suite or a change in hot water demand may mean the existing boiler is no longer the right size or type.
| Situation we find | What it usually points to |
|---|---|
| Boiler in good condition, single clear cause such as a blocked terminal, tube or switch | Repair, then regular annual service |
| Recurring EE plus other faults, heavy corrosion or sludge, hard-to-source parts | Get a written replacement quote and compare it with the repair quote |
| Vent route needs to be redone and the boiler is older | Often worth pricing replacement and new venting together |
| Any sign of flue gas leakage or a damaged heat exchanger | Boiler stays off until it is made safe, then repair or replace is decided |
Viessmann boiler error code EE service near me: Greater Vancouver coverage and brands we service
From our Burnaby base we service boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Housing stock varies a lot across the region, and it shapes how an air-proving fault like EE tends to show up.
In Vancouver and Burnaby, many older detached homes have been converted over the years from older heating to modern condensing boilers, and the vent route chosen at the time of conversion is worth a careful look when an air-proving code appears. In condos and townhouses, boilers often sit in tight closets with side-wall terminals near balconies and patios, where planters, storage bins or furniture can end up in front of a terminal.
On the North Shore, homes on slopes and among tall trees tend to collect more leaves and needles at low terminals, and wind-driven rain is common. In Surrey, Langley and Delta there is a broad mix of newer subdivisions and older homes, and we commonly check long vent runs and terminals close to fences, decks or landscaping. In Richmond, with plenty of townhouse strata and low-lying ground, condensate drains routed to pumps or shared drains deserve attention. New Westminster and the Tri-Cities mix older houses, low-rise strata and newer buildings, so we see a little of everything.
Our mild, wet coastal climate means boilers here run long, gentle cycles for much of the heating season, which produces a lot of condensate. That is one reason condensate trap and drain problems come up so often in this region. Snow is not frequent, but when it arrives it is often wet and heavy, and a low side-wall terminal can be buried overnight.
In strata buildings, terminal locations, access and any venting changes may involve the strata council or property manager. We can coordinate with them and keep you informed so the repair is not held up.
Viessmann is the boiler this page covers. We also service other gas boiler and combi brands, including Navien, Rinnai, Bosch and Noritz. BC Wide is an independent contractor: these are brands we service, and we are not a factory-authorized dealer or warranty centre for any of them. If your boiler may still be under manufacturer warranty, check the warranty paperwork before booking, since warranty conditions are set by the manufacturer.
Who should fix Viessmann boiler error code EE: licensing, permits and a written quote
An EE lockout sits right at the boundary between combustion air, venting and electrical controls on a gas appliance, so the person diagnosing it should be licensed for all of it. BC Wide Home Services Ltd is a TSBC-licensed independent contractor, gas contractor licence LGA0090068, with Class B gas licence CGA0028029, and the work is done by our own licensed gas fitters. Where a job needs a permit, such as a vent alteration, gas piping change or a boiler replacement, we pull it and arrange the inspection that comes with it.
Here is the plain split between what a homeowner may do on this fault and what is legally licensed work in BC.
- You may: check the power switch and breaker, confirm the gas valve is open, check the thermostat, clear loose debris from outside terminals you can reach from the ground, check the visible condensate line, and reset once if your manual allows it.
- Licensed technician only: opening the casing, testing or replacing the air pressure switch, sensing tubes, damper or combustion fan, any wiring or control work, any gas valve or burner work, and any work on the vent.
- Licensed and permitted where required: vent re-routing, gas piping changes and boiler replacement, followed by inspection where the permit calls for one.
- In writing, every time: what we found, a written quote before any work beyond diagnosis, and a record of what was done and tested.
- Ready to book or have a question about an EE code? Call (604) 473-9690.
More questions homeowners ask
What does Viessmann boiler error code EE mean?
EE means the air-pressure switch or air damper flap is faulty or stuck, so the boiler will not run; confirm against the manual for your unit. The boiler cannot prove its combustion air path, so it locks out instead of lighting. Expect no heat, and no hot water if the boiler also heats your water.
Can I reset a Viessmann boiler with error code EE?
Once, and only if your owner manual describes a reset for this lockout. Check the outside terminals and the visible condensate line first. If EE comes back, stop resetting and call a licensed gas technician, because repeated resets can hide a vent or air problem.
Is it safe to run my Viessmann boiler with error code EE?
While it shows EE the boiler is locked out and not firing, so it is not running at all. Never try to force it to run by bypassing or jumpering the air pressure switch. If you smell gas or a carbon-monoxide alarm sounds, leave the house and call FortisBC or 911 from outside.
Why does my Viessmann boiler keep showing EE in winter?
Cold, wet weather means longer run times and more condensate, and wet snow, leaves or ice at a low terminal can restrict air. A partly blocked condensate trap or a sagging vent that holds water also tends to behave worse during long cycles. If clearing the terminals does not hold, the switch, tubing or damper needs testing by a technician.
How much does it cost to fix Viessmann boiler error code EE?
It depends on the cause, which can range from clearing a blocked terminal or tube to replacing a switch, damper assembly or combustion fan, so we do not guess at a repair price before diagnosis. You receive a written quote before any work beyond the diagnostic visit. If replacement turns out to be the better option and you go ahead with BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.
Can you fix Viessmann boiler error code EE same day near me in Greater Vancouver?
Same-day where we can, across Vancouver, Burnaby, Surrey, Richmond, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. It depends on the day’s schedule and on whether the needed part is on hand, since Viessmann parts are model-specific. Call (604) 473-9690 and we will tell you honestly when we can be there.
- Vaillant Boiler Code F.85 — Flow/return sensor fitted on the same pipe | BC Wide
- Vaillant Boiler Error Codes & Repair | Greater Vancouver | BC Wide
- Viessmann Boiler Code 02 — Safety chain / burner lockout | BC Wide
- Viessmann Boiler Code 0A — Fan speed fault | BC Wide
- Viessmann Boiler Code 0B — Wind conditions / low water flow | BC Wide
- Viessmann Boiler Code 0C — Power supply / flame-after-shutdown fault | BC Wide
- Viessmann Boiler Code 0D — Reset button pressed too often | BC Wide
- Viessmann Boiler Code 0F — Service / maintenance due | BC Wide
- Viessmann Boiler Code 10 — Outdoor temperature sensor short circuit | BC Wide
- Viessmann Boiler Code 18 — Outdoor temperature sensor open circuit | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.