Weil-McLain boiler error code 4 is not a fault. It is a normal running status: the boiler is firing to make domestic hot water, either for the hot water side of a combi boiler or because an indirect hot water tank is calling for heat (confirm against the manual for your unit). Space heating usually pauses while it shows. Call a licensed technician only if 4 stays on with no hot water in use, the water never gets hot, or the house keeps going cold.
If your Weil-McLain boiler is showing 4 (Domestic hot water heating), here’s exactly what it means and what to do. This guide is part of our full Weil-McLain boiler error code list.
Severity: Status / informational.
What 4 means on a Weil-McLain boiler
Normal running status. The boiler is firing to produce domestic hot water (combi DHW or an indirect tank call). This is not a fault.
Common causes
- Active hot water demand
- Indirect tank calling for heat
What you can safely check first
- No action needed — this is normal operation
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
If the simple checks above don’t clear the code, have it diagnosed by a licensed technician. Repeated lockouts on a Weil-McLain boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Weil-McLain boiler repair across Greater Vancouver
If a Weil-McLain boiler showing 4 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Weil-McLain boiler codes
- Weil-McLain boiler 0 — Standby — no call for heat
- Weil-McLain boiler 3 — Space heating — burner active
- Weil-McLain boiler 6 — Burner off — setpoint reached
- Weil-McLain boiler E00 — Flame detected at startup (false flame)
- Weil-McLain boiler E02 — Ignition failed — 5 attempts (no flame)
- Weil-McLain boiler E03 — Internal control failure
Frequently asked questions
Is 4 on a Weil-McLain boiler serious?
It’s typically a status/informational code rather than a breakdown, but confirm against the symptoms. BC Wide repairs Weil-McLain boilers 7 days a week across Greater Vancouver.
How do I reset a Weil-McLain boiler after 4?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Weil-McLain boiler error code 4: what it means for your heat and hot water
When the display shows 4, the boiler is telling you what it is doing, not what is wrong. Code 4 means the burner is running and the boiler is putting its heat into domestic hot water: the hot water side of a combi unit, or the coil inside an indirect tank. Confirm that meaning against the manual for your unit, because display behaviour can differ between model families and control generations. In plain terms, someone opened a hot tap, started a shower or the dishwasher, or the indirect tank cooled down far enough that its control asked the boiler for heat.
Most Weil-McLain systems we work on in Greater Vancouver give hot water priority. While the boiler is serving hot water, it holds heat back from the radiators, baseboard convectors or in-floor loops. On a cold morning with a long shower running, you may notice the radiators cool off a little and then recover once the display changes back. That short pause is designed behaviour, not a sign of failure. A status code like this one also tells you the boiler is not locked out: its own safeties are still watching flame, water temperature and venting the whole time it runs.
Where code 4 becomes worth a phone call is when the status does not match what is actually happening in the house. Homeowners usually describe it in one of these ways:
- The display sits on 4 for hours even though nobody is using hot water.
- Code 4 shows and the burner sounds like it is running, but the taps never get properly hot.
- The house goes cold every time anyone uses hot water and stays cold long after.
- The boiler fires for hot water, stops, and fires again every few minutes all day long.
- Hot water comes out too hot, or swings between hot and lukewarm, while 4 is showing.
- You hear banging, kettling or gurgling from the boiler while it is heating hot water.
Weil-McLain boiler code 4 stuck on or no hot water: likely causes, most common first
None of the symptoms above changes the meaning of the code. They tell us that something around the hot water call, whether a control, a sensor, a valve, a pump or the heat exchanger itself, is not behaving as it should. These are the causes we find most often in Metro Vancouver homes, in roughly the order we run into them, with what you can safely look at yourself and the point where it becomes work for a licensed gas fitter.
1. Real, ongoing hot water demand. A hot tap left partly open, a dripping hot fixture or an appliance mid-cycle keeps the boiler in a genuine hot water call, so 4 stays up because it is correct. Owner-safe check: walk the house, close every hot tap fully and watch whether the display changes once demand stops.
2. An indirect tank that keeps calling for heat. If the tank’s temperature control is set high, or its sensor or aquastat reads low, the tank asks for heat over and over. Owner-safe check: compare the tank control setting to what the manual recommends, without going past the range the manual allows. Licensed call: a sensor or aquastat that keeps calling has to be tested with a meter, and the wiring between tank and boiler checked.
3. A hot water recirculation loop running all the time. A recirculation pump on the domestic side pulls heat out of the tank continuously, so the tank calls for heat far more often than a household’s actual use would explain. Owner-safe check: if the pump has a timer or a switch you were shown how to use, confirm it is set as intended. Licensed call: changing pump controls, wiring or check valves.
4. A combi-side flow sensing problem or a sticking diverter valve. On combi models the boiler starts a hot water call when it senses water flowing. A sensor that misreads, or a valve that sticks toward the hot water side, can leave the boiler heating domestic water nobody asked for while the heating loops starve. This is licensed work only; there is no owner-safe fix inside the cabinet.
5. Reduced heat transfer from sludge, corrosion debris or deposits. Metro Vancouver water is soft, so the heating side of an older system usually suffers from sludge and corrosion debris rather than hard limescale. On the domestic side of a combi, some heat-driven mineral and debris buildup is still possible over the years, though it tends to be modest here. Either way, hot water calls run long, the water arrives lukewarm and the heat exchanger may get noisy. Licensed call: flushing, strainer cleaning and water treatment.
6. Wiring, relay or zone control faults. A damaged thermostat wire, a loose terminal, a failing relay or a zone controller that will not release the call can hold the boiler in hot water mode. Licensed call: all electrical diagnosis inside the boiler and controls.
Owner-safe checks for any of these are limited to the outside of the equipment: confirm the boiler’s power switch and breaker are on, confirm the gas supply valve handle is in the open position, confirm the thermostat is set to call for heat, look at the outside intake and exhaust terminals for leaves, nests or snow, and check that the visible condensate drain line is not kinked, crushed or sitting in a puddle. Reset the boiler only if the owner manual allows it, and only once. Never open the burner compartment, the gas valve or the control panel, never bypass or jumper anything, and never keep resetting a boiler that will not behave.
Gas and carbon monoxide safety: a boiler firing for hot water burns gas exactly as it does for heating, so every combustion safety rule applies while 4 is showing. If you smell gas or a carbon monoxide alarm sounds, do not touch switches and do not try to reset the boiler. Get everyone outside, then call FortisBC or 911 from outside the home. Keep working CO alarms near sleeping areas and near the mechanical room.
| What you notice | Likely cause | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| Code 4 stays on with no hot water in use | A tap left open, or the indirect tank calling constantly | Close all hot taps and watch the display; compare tank setting to the manual | The call never ends with every tap closed |
| Code 4 shows but taps stay lukewarm | Sludge or debris reducing heat transfer, or a control fault | Confirm the gas supply valve is open and the boiler has power | Any time the burner runs and water does not heat properly |
| House goes cold during and after hot water use | Diverter valve sticking or a call that will not release | Confirm the thermostat is calling for heat | Heating does not resume once hot water demand stops |
| Boiler fires for hot water every few minutes | Recirculation running all day or a tank sensor misreading | Check any recirculation timer is set as intended | Short cycling continues with the recirculation pump off |
| Banging or kettling while heating hot water | Sludge or poor water flow through the heat exchanger | Note when it happens and how long it lasts | Right away; noise under fire is a flow or debris problem |
| Gas smell or CO alarm while code 4 shows | Possible gas leak or combustion and venting problem | Leave the home; do not reset or touch switches | Call FortisBC or 911 from outside, then a licensed gas fitter |
How our Weil-McLain boiler code 4 repair visit works
Because code 4 is a status rather than a fault, a good visit is about watching the boiler do its job and measuring where the hot water call goes wrong, not swapping parts on a guess. This is how our technicians run it, step by step.
- Step 1, the call: phone (604) 473-9690 and tell us what the display shows, how long it stays on 4, and what you notice with heat and hot water. We book same-day where we can; we will tell you honestly when that is not possible, and we never promise a guaranteed arrival window.
- Step 2, safety first on arrival: we check for gas at the visible piping and connections, test for carbon monoxide at the appliance and in the room, and look over the venting and the outside terminals before anything else.
- Step 3, watch a live hot water call: we open a tap or let the indirect tank call, confirm 4 appears when it should, and confirm it clears and heating resumes once demand ends. That single observation tells us whether the problem is the call itself or what happens during it.
- Step 4, measure with the right meters: a multimeter for control voltages and sensor readings, a manometer for gas pressure, a combustion analyzer for burn quality, and temperature readings on the supply, return and tank sides.
- Step 5, narrow it down: the parts most often involved, in general terms, are the indirect tank sensor or aquastat, the combi flow sensor, the diverter valve, circulator pumps, zone controls and relays, the wiring between them, and the condition of the heat exchanger and system water.
- Step 6, test the safeties: flame sensing, the high-limit control, the low-water cutoff where one is fitted, the pressure relief valve and the venting, so we are not handing back a boiler that only looks fixed.
- Step 7, a written quote before any work beyond diagnosis: you see what we found, what we recommend and what the repair involves, in writing, and nothing more happens until you approve it.
- Step 8, repair, re-test and explain: after the repair we run another full hot water call and a heating call, then walk you through what changed and what to watch for.
Repair or replace an older Weil-McLain boiler with code 4 hot water problems?
Most code 4 complaints end in a repair: a sensor, a valve, a pump, a control setting or a system flush. The repair-or-replace question only comes up when the hot water trouble is a symptom of a boiler or system near the end of its working life. On site, what decides it is the condition of the heat exchanger, how much sludge and corrosion the system water shows, whether the parts we need are still readily available for that model family, the state of the venting, and whether the boiler can keep up with both your heating and your hot water.
Repair usually makes sense when the heat exchanger is sound, the venting is correct, the fault is a single control or valve, and the boiler has otherwise been reliable. Replacement starts to make sense when the heat exchanger is deteriorating, when repeated repairs keep chasing the same hot water and heating conflicts, or when a household’s hot water use has simply outgrown the setup. A control board or heat exchanger is among the more expensive repairs on any boiler, so on an older unit we will show you the trade-off honestly and in writing rather than push either answer.
If replacement is the better path, the in-home estimate for a new boiler is free. Options typically include a modern condensing boiler paired with an indirect tank, or a combi boiler where the house and its hot water use suit one. Brands we service and install include Weil-McLain, Navien, Rinnai and Bosch; we are an independent contractor, not a dealer or warranty centre for any of them, so our recommendation is about fit, venting and gas supply, not a sales quota. Every replacement is done under a Technical Safety BC permit and inspection.
Diagnostic service calls are $189.00. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.
Weil-McLain boiler code 4 service near me: Greater Vancouver areas we cover
We service Weil-McLain boilers across Greater Vancouver from our Burnaby base, including Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities, the North Shore, New Westminster, Delta and Langley. Every area has its own mix of housing, and that mix shapes what a code 4 call usually turns out to be.
In Vancouver and New Westminster we often meet older houses that were converted to modern boilers, frequently feeding cast-iron radiators and an indirect tank, where sludge from decades-old piping is a common reason hot water calls run long. Burnaby and Coquitlam have a wide spread of postwar houses, townhouses and newer builds, so we see everything from original hydronic loops to recent combi installations. The North Shore and the hillside parts of the Tri-Cities tend to have longer or more awkward vent routes, and wet leaves and moss around low terminals are a regular finding in fall.
Surrey, Delta, Langley and Richmond include many newer suburban homes, some with in-floor radiant heating sharing a boiler with an indirect tank, where zone controls and priority settings matter. In strata buildings and townhouse complexes anywhere in the region, mechanical room access, building rules and booking a time that suits the strata council can matter as much as the repair itself, so tell us about any access requirements when you call.
Our mild, wet coastal climate also shapes the job. Hot water use stays steady all year while heating demand rises and falls, so a boiler can spend a lot of its life showing 4. Rain, leaves and the occasional snowfall can partly block low outdoor terminals, and the region’s soft water means we look for sludge and corrosion on the heating side rather than the hard scale common in other parts of the country.
Who services Weil-McLain boilers in Greater Vancouver: licensing, permits and written quotes
BC Wide is an independent, Technical Safety BC licensed gas contractor (licence LGA0090068, Class B gas CGA0028029) serving Metro Vancouver since 1999. Weil-McLain is a brand we service, alongside other common boiler brands; we are not a factory-authorized dealer or warranty centre, and we say so plainly so you know who you are hiring.
Gas work on a boiler, including the gas valve, burner, venting, gas piping and most electrical work inside the controls, is legally restricted to licensed trades in BC. Our own licensed gas fitters do that work, permits are pulled where the job requires one, and permitted work is inspected. What you should always see in writing before work beyond diagnosis begins is what we found, what we recommend, the scope of the repair or replacement, and whether a permit applies.
If you are not sure whether your boiler’s code 4 is normal or a sign of trouble, call (604) 473-9690. We will ask a few questions first, and if it sounds like ordinary hot water priority, we will tell you so.
More questions homeowners ask
What does code 4 mean on a Weil-McLain boiler?
Code 4 is a normal running status, not a fault: the boiler is firing to produce domestic hot water, either for a combi’s hot water side or an indirect tank calling for heat. Confirm against the manual for your unit, since display behaviour can vary between model families. It only needs attention if it stays on with no hot water in use or the water never gets hot.
Can I reset a Weil-McLain boiler showing code 4?
There is normally nothing to reset, because code 4 is a status rather than a lockout. If something else seems wrong, reset only if your owner manual allows it, and only once. If the problem returns, stop resetting and book a licensed technician, because repeated resets can hide a real safety issue.
Is it safe to run my Weil-McLain boiler while it shows code 4?
Yes, in normal use code 4 simply means the boiler is heating hot water and its safeties are active. It is not safe to keep running if you smell gas, a carbon monoxide alarm sounds, or you hear banging under fire. In those cases leave the home and call FortisBC or 911 from outside, then have a licensed gas fitter inspect it.
Why is my Weil-McLain boiler stuck on code 4?
The most common reasons are real ongoing demand such as a hot tap left open, an indirect tank control that keeps calling, a recirculation pump running all day, or a sticking diverter valve or flow sensor on a combi model. Close every hot tap first and watch whether the display changes. If it stays on 4 with no demand, have the controls tested by a licensed technician.
Why does my house get cold when my Weil-McLain boiler shows 4?
Most systems give hot water priority, so heating pauses briefly while the boiler shows 4, and that is normal. If the house stays cold long after hot water use ends, the hot water call is probably not releasing, often because of a diverter valve, zone control or tank sensor. That needs a licensed diagnosis.
How much does it cost to have a Weil-McLain boiler code 4 checked in Greater Vancouver?
Diagnostic service calls are $189.00. After diagnosis you get a written quote before any further work, and nothing proceeds without your approval. If the outcome is a replacement and you go ahead with BC Wide, the $189.00 diagnostic charge is waived and taken off the installation.
- Vaillant Boiler Code F.85 — Flow/return sensor fitted on the same pipe | BC Wide
- Vaillant Boiler Error Codes & Repair | Greater Vancouver | BC Wide
- Viessmann Boiler Code 02 — Safety chain / burner lockout | BC Wide
- Viessmann Boiler Code 0A — Fan speed fault | BC Wide
- Viessmann Boiler Code 0B — Wind conditions / low water flow | BC Wide
- Viessmann Boiler Code 0C — Power supply / flame-after-shutdown fault | BC Wide
- Viessmann Boiler Code 0D — Reset button pressed too often | BC Wide
- Viessmann Boiler Code 0F — Service / maintenance due | BC Wide
- Viessmann Boiler Code 10 — Outdoor temperature sensor short circuit | BC Wide
- Viessmann Boiler Code 18 — Outdoor temperature sensor open circuit | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.