Weil-McLain error code E31 means the boiler control has read a short circuit on the outlet (supply) water temperature sensor and has gone into a hard lockout. Expect no heat and, if the boiler also heats an indirect hot water tank, no hot water either. Confirm the meaning against the manual for your unit. Reset once only if the manual allows it. If E31 returns, the sensor or its wiring needs testing by a licensed technician. Call BC Wide at (604) 473-9690.
If your Weil-McLain boiler is showing E31 (Outlet (supply) sensor shorted), here’s exactly what it means and what to do. This guide is part of our full Weil-McLain boiler error code list.
Severity: Critical — likely no heat / lockout.
What E31 means on a Weil-McLain boiler
Hard lockout. The control read a short circuit on the outlet/supply water temperature sensor.
Common causes
- Shorted outlet temperature sensor
- Damaged sensor wiring or connector
What you can safely check first
- Reset once
- If it recurs, a technician must test/replace the sensor — sensor work is for a pro
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Weil-McLain boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Weil-McLain boiler repair across Greater Vancouver
If a Weil-McLain boiler showing E31 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Weil-McLain boiler codes
- Weil-McLain boiler 0 — Standby — no call for heat
- Weil-McLain boiler 3 — Space heating — burner active
- Weil-McLain boiler 4 — Domestic hot water heating
- Weil-McLain boiler 6 — Burner off — setpoint reached
- Weil-McLain boiler E00 — Flame detected at startup (false flame)
- Weil-McLain boiler E02 — Ignition failed — 5 attempts (no flame)
Frequently asked questions
Is E31 on a Weil-McLain boiler serious?
It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs Weil-McLain boilers 7 days a week across Greater Vancouver.
How do I reset a Weil-McLain boiler after E31?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Weil-McLain boiler error code E31: what it means for your heat and hot water
In plain terms, E31 is the boiler telling you it no longer has a trustworthy reading of how hot the water leaving it is. The outlet (supply) sensor is the control’s main eye on the water going out to your radiators, baseboard convectors or in-floor loops. When that reading looks like a dead short, the control cannot tell whether the water is cool, warm or dangerously hot, so it does the safe thing: it stops firing and holds a hard lockout. That is by design. A boiler that kept running blind could overheat the water, so the shutdown is protecting you and the equipment rather than failing you.
What this means for the house depends on how the boiler is piped. If it heats the home only, you lose space heating, and rooms cool gradually because a hydronic system holds some heat in the water, the radiators and the floor. If the boiler also heats an indirect hot water tank, that tank will slowly run cold as you use it. The code does not by itself indicate a gas leak or carbon monoxide, but any lockout on a combustion appliance is a reason to stay alert to odours and alarms until it is properly repaired.
What homeowners usually notice before they ever read the display:
- The house is getting colder even though the thermostat is calling for heat.
- Radiators, baseboards or heated floors are lukewarm or cold to the touch.
- The boiler is quiet: no burner sound, no fan, and the circulator pump may not be running.
- The display shows E31 and the boiler does not restart on its own.
- Hot water from an indirect tank runs out sooner than normal, then goes cold.
- The code cleared after a reset, then came back hours or days later.
Weil-McLain boiler error code E31: likely causes and what we check first
The meaning of this code is narrow: the control read a short on the outlet sensor circuit. On site, that narrows the job to three places: the sensor itself, the wiring and connector between the sensor and the control, and, less often, the control’s own input for that sensor. These are the likely causes in the order we most often find them, with what you can safely look at and where it becomes a licensed call. Confirm the code meaning against the manual for your unit, because code lists and displays vary between models and control versions.
- 1. The outlet sensor has failed internally. Temperature sensors are simple parts, but they live through thousands of heating and cooling cycles and they do wear out. A failed sensor can read as a short. Owner check: nothing beyond a single reset if the manual allows it. Licensed call: testing the sensor’s resistance against the manufacturer’s published chart and replacing it if it is out.
- 2. Moisture in the sensor connector. A small weep from a nearby fitting, relief valve, air vent or condensate connection can drip onto the connector and bridge the terminals. Owner check: look, without touching anything, for water stains, drips or white or green crust on and around the boiler and on the floor below it. Licensed call: drying and inspecting the connector, replacing it if damaged, and finding the source of the water.
- 3. Damaged or pinched sensor wiring. Wires can chafe against sheet metal, get pinched when a panel is refitted, or be disturbed during other work nearby. Owner check: nothing inside the cabinet, but tell the technician about any recent work on the boiler, the piping or the mechanical room. Licensed call: tracing and testing the harness end to end.
- 4. Corroded terminals at the sensor or the control. Basement mechanical rooms and closets beside crawlspaces can stay damp, and corrosion can create a low-resistance path that the control reads as a short. Owner check: note any dampness, standing water or rust in the room. Licensed call: cleaning or replacing terminals and looking at why the space is damp.
- 5. A fault in the control’s sensor input. This is the least common cause and should only be concluded after the sensor and wiring test good. Licensed call: confirming with meters before any control part is quoted, because a control board is one of the more expensive parts on a boiler and should never be replaced on a guess.
| Likely cause | What you might notice | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| Failed outlet sensor | E31 returns after a reset, sometimes as the boiler warms up | One reset only, and only if the manual allows it | Sensor resistance test against the published chart and replacement |
| Moisture at the connector | Drips, stains or crust on or near the boiler | Look for water without touching anything | Connector repair plus finding and fixing the leak source |
| Pinched or chafed wiring | Code appeared soon after other work on the boiler | Tell us what work was done and when | Harness tracing, testing and repair |
| Corroded terminals | Damp mechanical room, rust on nearby metal | Note dampness or standing water | Terminal cleaning or replacement |
| Control input fault | Sensor and wiring test good but E31 persists | None | Meter confirmation before any control part is quoted |
Can you fix Weil-McLain error code E31 yourself? Owner-safe checks and when to stop
Honestly, no. The repair for E31 is sensor and wiring work inside the boiler cabinet, and that belongs to a licensed technician. Gas appliance work in BC is restricted to licensed gas fitters, and the boiler’s electrical controls should be handled by someone qualified to test them safely. What you can do is rule out the simple things that make any boiler look dead, and gather good information for the call. Do these checks once, in order, and stop if anything feels wrong:
What not to do: do not remove the boiler’s front panel to look at the sensor, do not unplug and replug connectors, do not jumper or bypass any sensor or switch, and do not keep cycling power to force the boiler to run. A boiler that is forced past a lockout is running without the information it needs to stay safe, and a homeowner who disturbs the wiring can turn a simple sensor repair into a longer job.
Gas and carbon monoxide safety: if you smell gas (a rotten-egg odour) or a carbon monoxide alarm sounds, do not touch light switches, the thermostat or the boiler, and do not try a reset. Get everyone out of the house, then call FortisBC or 911 from outside. Every home with a gas boiler should have working CO alarms near sleeping areas and on each level. Once the utility or fire department has made the home safe, call us for the repair.
It becomes a licensed call the moment E31 comes back after one reset, or straight away if you see water at the boiler, notice a scorched or unusual smell, or heard the boiler making new noises before it locked out.
- Power: make sure the boiler’s service switch, often mounted near the boiler or at the top of the basement stairs, is on, and that the breaker has not tripped. Do not keep resetting a breaker that trips again.
- Gas supply: confirm the manual gas shut-off valve to the boiler is open, which on most quarter-turn valves means the handle lines up with the pipe. Do not operate any valve you are unsure about.
- Thermostat: check that it is set to heat, set above the current room temperature, and has fresh batteries if it uses them.
- One reset: if your owner manual describes a reset for this lockout, do it once. If E31 returns, leave the boiler locked out and call.
- Outside terminals: on a direct-vent boiler, look at the intake and exhaust terminals outside the house and clear leaves, snow, ice or nests from around them by hand, from outside, without removing or loosening any part of the vent.
- Condensate drain: look at the visible condensate tube or trap for kinks, disconnection or pooled water. Do not take it apart.
- Pressure and leaks: note what the boiler pressure gauge reads and whether there is water on the floor, so you can tell us when you call.
How our Weil-McLain E31 repair visit works, step by step
Diagnostic service calls are $189.00. Here is what that visit involves, so you know what a correct job looks like and what you should see in writing at the end of it.
- 1. Booking and triage: when you call (604) 473-9690 we ask what the display shows, whether heat, hot water or both are affected, and what you have already checked. We book same-day where we can, depending on the day’s schedule and your location, and we will not promise an arrival window we cannot keep.
- 2. Safety first on arrival: the technician checks for gas odour and carbon monoxide at the appliance and in the room before working on the boiler.
- 3. Confirming the code: we read the fault history on the control where the model allows it, so we can see whether E31 is a one-off or a repeat and whether anything else has been logged alongside it.
- 4. Testing with the right meters: with power isolated, we test the outlet sensor’s resistance with a digital multimeter and compare it with the manufacturer’s published chart for the water temperature at that moment. We then test the wiring and connector end to end for shorts, chafing and moisture.
- 5. Finding the cause, not just the part: if water reached the connector, we find out where it came from. Replacing a sensor without fixing the dripping fitting above it simply brings E31 back.
- 6. Written quote before any work beyond diagnosis: you see the parts involved in plain terms, typically the outlet sensor, a connector or a section of wiring, together with the labour, before we go ahead. Nothing beyond the diagnosis is done without your approval.
- 7. Repair and test the safeties: after the repair we restart the boiler and test its safety functions, including the high-limit, flame sensing and low-water protection where fitted, and we confirm the outlet sensor reading tracks the real water temperature as the boiler heats up.
- 8. Combustion and venting check: we check combustion with an analyzer, inspect the venting and the outside terminals, and confirm the condensate system drains freely.
- 9. Paperwork: you receive a written record of what we found, what we replaced and what we tested, with any recommendations listed separately from the repair itself so you can decide on them in your own time.
Should I repair or replace an older Weil-McLain boiler with an E31 code?
In most cases E31 on its own is a repair, not a reason to replace the boiler. A supply sensor and its wiring are small, serviceable parts, and fixing them correctly restores normal operation. The replacement conversation only starts when the E31 visit turns up something bigger, or when the boiler is already close to the end of its working life and the owner wants to plan rather than react.
These are the things that actually decide it on site:
If the visit shows the boiler is not worth repairing, you will hear that plainly and you will not be pushed. The in-home estimate for replacing or installing equipment is free, and it comes as a written quote that sets out the equipment, venting, gas piping, near-boiler piping and permit. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. We never put a figure on a replacement before seeing the home, so ask for that written quote rather than relying on numbers you read online.
- Age and service history: an older boiler with a string of recent repairs is a different decision from a well-maintained one showing its first fault.
- Heat exchanger condition: signs of corrosion, leaks or heavy sludge build-up change the decision far more than a sensor ever will.
- Water quality in the loop: Metro Vancouver’s soft water means hydronic trouble here is usually sludge and corrosion rather than limescale. Black or rusty water from a purge point tells us the system needs cleaning and treatment whatever you decide.
- Parts availability: on some older controls, parts get harder to source over time. We tell you if that is the case for your unit before you commit to a repair.
- Repeated lockouts with different causes: if the boiler has been locking out for one reason after another, the control or the wider system may be the real issue.
- Sizing and comfort: a replacement can be sized to the home’s measured heat loss, which older installations were not always.
Weil-McLain boiler E31 repair near you: Greater Vancouver coverage and who does the work
BC Wide Home Services Ltd has serviced gas and hydronic heating in Metro Vancouver since 1999, working out of Burnaby. We handle E31 and other Weil-McLain boiler lockouts in Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the rest of the Tri-Cities including Port Coquitlam and Port Moody, the North Shore, New Westminster, Delta and Langley.
Housing stock across the region varies, and it shapes the job. Older detached homes in parts of Vancouver, Burnaby and New Westminster often have boilers that replaced earlier equipment, sometimes connected to older piping in tight mechanical rooms. Many townhouse and strata buildings in Richmond, Surrey, Coquitlam and Langley use hydronic heat, where access, venting rules and strata approval can affect when work happens. Some homes on the North Shore and in Delta have mechanical spaces that run damp through our wet coastal winters, which matters for E31 because moisture and sensor connectors do not mix. We check rather than assume, because every house is different.
Our mild, wet climate means boilers here run long, gentle heating seasons rather than short, hard ones, so sensors see a great many heating cycles each year. Soft water keeps limescale low but leaves older loops prone to sludge and corrosion, and that debris is part of what we look at during an E31 visit.
Who does the work matters on a gas appliance:
- Independent TSBC-licensed contractor: gas contractor licence LGA0090068 and Class B gas licence CGA0028029. We are not a factory-authorized dealer or warranty centre for any brand.
- Our own licensed gas fitters and technicians carry out the diagnosis and repair.
- Permits and inspections are arranged wherever the work requires them, such as boiler replacements and gas piping changes.
- A written quote before any work beyond the diagnosis, every time.
- Boiler brands we service include Weil-McLain, Viessmann, Navien, Lochinvar, IBC, Buderus, Triangle Tube and Rinnai.
More questions homeowners ask
What does Weil-McLain boiler error code E31 mean?
It means the control has read a short circuit on the outlet (supply) water temperature sensor and has locked the boiler out. Until it is fixed, expect no heat, and no hot water if the boiler heats an indirect tank. Confirm the meaning against the manual for your unit.
Can I reset a Weil-McLain boiler with an E31 code?
You can reset once, and only if your owner manual describes a reset for this lockout. If E31 comes back, stop and call a licensed technician, because repeated resets will not fix a shorted sensor or wire and can hide a real problem. Never bypass or jumper the sensor.
Is it safe to run my Weil-McLain boiler with E31 showing?
The boiler will not fire with E31 active, and it should not be forced to. The lockout exists because the control cannot read the supply water temperature, which it needs to run safely. If you smell gas or a CO alarm sounds, leave the house and call FortisBC or 911 from outside.
How much does it cost to fix Weil-McLain error code E31?
Diagnostic service calls are $189.00. After testing, you get a written quote for the repair before any further work, because the answer depends on whether it is the sensor, the wiring, a connector or something less common. If you decide to replace the boiler through BC Wide instead, the $189.00 diagnostic charge is waived.
Why does E31 keep coming back on my Weil-McLain boiler?
A code that clears and returns usually points to an intermittent short, such as a sensor failing as it heats or moisture reaching the connector. Swapping parts without finding the cause, like a dripping fitting above the connector, brings it back. A meter-based diagnosis is the reliable way to end it.
Who repairs Weil-McLain boiler error code E31 near me in Greater Vancouver?
BC Wide services Weil-McLain boilers across Vancouver, Burnaby, Surrey, Richmond, Coquitlam, the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor, not a factory dealer. Call (604) 473-9690 and we will book same-day where we can.
- Vaillant Boiler Code F.85 — Flow/return sensor fitted on the same pipe | BC Wide
- Vaillant Boiler Error Codes & Repair | Greater Vancouver | BC Wide
- Viessmann Boiler Code 02 — Safety chain / burner lockout | BC Wide
- Viessmann Boiler Code 0A — Fan speed fault | BC Wide
- Viessmann Boiler Code 0B — Wind conditions / low water flow | BC Wide
- Viessmann Boiler Code 0C — Power supply / flame-after-shutdown fault | BC Wide
- Viessmann Boiler Code 0D — Reset button pressed too often | BC Wide
- Viessmann Boiler Code 0F — Service / maintenance due | BC Wide
- Viessmann Boiler Code 10 — Outdoor temperature sensor short circuit | BC Wide
- Viessmann Boiler Code 18 — Outdoor temperature sensor open circuit | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.