Weil-McLain boiler error code E37 means the boiler’s control has detected an open circuit on the return water temperature sensor, so it has gone into a hard lockout and will not fire. That usually means no heat, and no hot water if the boiler also heats an indirect tank. Confirm the meaning against the manual for your unit. Reset once only if your manual allows it; if E37 returns, call a licensed technician to test the sensor, wiring and connector. BC Wide: (604) 473-9690.
If your Weil-McLain boiler is showing E37 (Return sensor open), here’s exactly what it means and what to do. This guide is part of our full Weil-McLain boiler error code list.
Severity: Critical — likely no heat / lockout.
What E37 means on a Weil-McLain boiler
Hard lockout. The control detected an open circuit on the return water temperature sensor.
Common causes
- Open or disconnected return sensor
- Broken sensor wire or loose connector
What you can safely check first
- Reset once; if it persists, call a technician to check the return sensor and wiring
Only attempt the basics above. Do not open the gas train, burner compartment or control wiring.
When to call a technician
This is a fault that should be diagnosed by a licensed technician. Repeated lockouts on a Weil-McLain boiler usually point to a real fault that will keep recurring until it’s fixed properly — and continually resetting power can hide a safety issue.
BC Wide Heating & Air Conditioning has serviced Greater Vancouver boilers since 1999. Diagnostics and repairs are carried out by our own Technical Safety BC–licensed technicians (gas contractor licence LGA0090068, Class B Gas Licence CGA0028029) — never subcontractors — and we’re rated 4.7★ across 180+ Google reviews. Honest pricing and free written quotes on replacements.
Weil-McLain boiler repair across Greater Vancouver
If a Weil-McLain boiler showing E37 won’t reset or has locked out, don’t keep cycling the power — you can mask a real fault or a safety condition. BC Wide provides fast boiler repair and emergency HVAC service 7 days a week throughout the Lower Mainland. Call 604-473-9690 or email info@bcwide.ca and a licensed technician will diagnose the real cause and get your heat & comfort back. See our emergency HVAC service.
Related Weil-McLain boiler codes
- Weil-McLain boiler 0 — Standby — no call for heat
- Weil-McLain boiler 3 — Space heating — burner active
- Weil-McLain boiler 4 — Domestic hot water heating
- Weil-McLain boiler 6 — Burner off — setpoint reached
- Weil-McLain boiler E00 — Flame detected at startup (false flame)
- Weil-McLain boiler E02 — Ignition failed — 5 attempts (no flame)
Frequently asked questions
Is E37 on a Weil-McLain boiler serious?
It’s a lockout/safety code — the boiler has shut down and needs prompt diagnosis. BC Wide repairs Weil-McLain boilers 7 days a week across Greater Vancouver.
How do I reset a Weil-McLain boiler after E37?
You can try one power cycle at the breaker/switch after checking the filter and thermostat. If the code returns, stop resetting it and book a licensed technician — a recurring code is a real fault, not a glitch.
Weil-McLain boiler error code E37: what it means for your heat, hot water and safety
In owner terms, E37 is the boiler telling you it has lost track of how hot the water coming back from your radiators, hydronic baseboard loops or in-floor tubing is. The return sensor is a small temperature probe on the return side of the boiler. The control reads it constantly and uses it, together with the supply reading, to judge how hard to fire, when to slow down and whether the heat exchanger is being protected. When the control sees an open circuit on that sensor, meaning the electrical signal has effectively disappeared, it cannot trust its own picture of the water temperature, so it stops the burner and locks out. Confirm the exact wording against the manual for your unit, since display text can vary between control generations.
A lockout like this is a protective decision, not a sign that the boiler is about to do something dangerous. The control has done its job by shutting down rather than guessing. These are the things owners usually notice first:
- The house is getting colder and the radiators or floors feel lukewarm or cold to the touch.
- The boiler display shows E37 and the burner does not light, even though the thermostat is calling for heat.
- If the boiler also heats an indirect hot water tank, showers run warm for a while and then go cold once the stored water is used up.
- The circulator pump may keep running for a while after the lockout, so you hear water moving but feel no heat.
- The code comes back after a reset, sometimes straight away and sometimes after a few minutes or hours of running.
- The fault started soon after other work near the boiler, such as a renovation, a leak repair or someone moving stored items in the mechanical room.
Weil-McLain boiler error code E37: what we check first, most likely cause first
We work through E37 in the same order every time, because the most common faults, and usually the simplest to fix, sit at the start of the list. The numbered list below is our usual order on site. The table that follows shows what an owner can safely look at for each cause and where it turns into a licensed job.
Intermittent E37 is common, and it is worth understanding why. A connector that is half seated, a wire with a cracked conductor inside intact insulation, or a terminal with light corrosion can read normally when cold and then go open as the pipe warms and expands, or when the boiler vibrates at start-up. A code that appears at random and then clears is a strong hint that the fault is somewhere in the wiring path rather than in the control itself.
- 1. A loose, unplugged or half-seated sensor connector. Connectors get knocked during filter changes, pipe work, painting or storage shuffles in tight mechanical rooms. This is the most frequent cause we find.
- 2. A damaged sensor wire. Wires get pinched behind panels, stretched when the boiler is serviced, chewed by rodents in crawlspaces and garages, or cooked where they run too close to hot piping or the flue.
- 3. A failed return sensor. Temperature sensors of this type can fail open with age, years of heat cycling or moisture getting into the probe. When the sensor itself is open, the wiring tests fine and the probe does not.
- 4. Corrosion or moisture at the terminals. A weeping fitting, a dripping relief valve or condensation from a cold pipe above the connector can leave green or white deposits on the pins and break the circuit on and off.
- 5. A sensor that has come loose from the pipe or its mounting. This more often shows up as odd temperature readings than as an open circuit, but a probe hanging by its leads puts strain on the wire and the connector and often ends in an open fault.
- 6. A fault at the control board input. This is the least common cause and the last thing we condemn. We only call the board when the sensor and every metre of wiring test good and the control still reports an open circuit.
| Likely cause | What an owner can safely check | When it becomes a licensed call |
|---|---|---|
| Loose or unplugged connector | Look, without touching or opening anything, for an obviously disconnected plug near the return pipe, and note any recent work in the area | Any reseating of connectors inside the boiler jacket or behind panels |
| Damaged sensor wire | Look for chewed, crushed or melted wiring you can see from outside the boiler, and for signs of rodents nearby | Testing continuity, repairing or replacing wiring and rerouting it away from heat |
| Failed return sensor | Nothing to check directly; record when the code appears and whether one reset clears it | Measuring the sensor against the manufacturer’s published values and replacing it |
| Corrosion or moisture at terminals | Look for drips, wet spots, rust trails or a relief valve discharging near the boiler | Cleaning or replacing terminals and fixing the source of the leak |
| Sensor loose from pipe or mounting | Note whether you can see a probe dangling from its mount | Remounting the probe correctly so it reads true water temperature |
| Control board input fault | Nothing; this is a diagnosis by elimination | Board testing and replacement, followed by a full safety check |
Can I reset a Weil-McLain boiler with error code E37? Owner-safe checks first
You can try one reset if the manual for your unit permits it, after working through the checks below. If E37 comes back, stop there. A second, third or tenth reset will not repair an open circuit, and repeated lockout cycles add wear and can hide a separate fault. Most of these checks will not cure an E37 on their own, but they rule out other problems and give the technician useful information before arriving.
- Power: confirm the boiler’s service switch is on and the breaker has not tripped. Do not keep resetting a breaker that trips again; that is a licensed electrical call.
- Gas supply: make sure the manual shut-off valve on the gas line to the boiler is open, with the handle in line with the pipe. Do not touch any other part of the gas train.
- Thermostat: confirm the thermostat or zone control is calling for heat, has working batteries if it uses them, and is set above the current room temperature.
- One reset only: use the reset method described in your owner manual, once. Write down the time and whether the code returns immediately or later.
- Outside venting: if the boiler vents through a side wall or the roof, check from outside that the intake and exhaust terminals are clear of leaves, snow, nests and stored items. A blocked vent causes other lockouts, and we want to rule it out.
- Condensate: look at the visible condensate drain line and trap for kinks, disconnection or overflow. Not an E37 cause in itself, but water leaking near wiring can be.
- Leaks: note any wet floor, drip or crusty deposits around the boiler and its piping, and mention it when you call.
What owners should never do with an E37 lockout, and the gas safety line
Do not remove the boiler jacket or control cover, unplug or jumper the sensor, swap sensors between ports, bridge terminals with a piece of wire, or keep cycling power to force the boiler to run. The return reading is part of how the control protects the heat exchanger, and fooling it can let the boiler run in conditions it was designed to avoid. Gas appliance work in British Columbia is restricted to licensed gas fitters, and most electrical work inside the appliance is restricted to licensed trades as well. Looking is safe; opening the boiler is not.
Gas and carbon monoxide safety: if you smell gas, or your carbon monoxide alarm sounds, do not touch light switches, the thermostat or the boiler. Get everyone out of the home, then call FortisBC or 911 from outside. Every home with a gas boiler should have working CO alarms near sleeping areas and on the level where the boiler sits, tested regularly and replaced at the end of their service life.
An open return sensor on its own does not create a gas or carbon monoxide hazard, because the boiler has stopped firing. The risk lies in what happens next: repeated resets, makeshift bypasses, or a long outage during a cold snap that puts pipes in exterior walls or unheated spaces at risk of freezing. Call early rather than waiting it out.
How our Weil-McLain boiler E37 repair visit works, step by step
When you call (604) 473-9690 about an E37 lockout, we ask a few questions to plan the visit: roughly how old the boiler is, whether it also heats your hot water, whether the code came back after a reset, and whether any work was done near the boiler recently. We offer same-day where we can, depending on the day’s schedule and where you are in the region, and we will tell you honestly when that is not possible. Diagnostic service calls are $189.00.
Our technicians are our own licensed staff working under BC Wide’s Technical Safety BC gas contractor licence LGA0090068 and Class B gas licence CGA0028029, never subcontractors. We are an independent contractor, not a Weil-McLain authorised dealer or warranty centre. If your boiler may still be covered by the manufacturer, keep your paperwork handy; warranty decisions rest with the manufacturer, and we will give you a clear written account of what we found so you can follow it up.
- Step 1, confirm and record. The technician reads the display and the control’s fault history where the model stores it, and asks you when the code appears. A history of intermittent faults points us straight to the wiring path.
- Step 2, visual inspection. With the boiler safely isolated, we inspect the return sensor, its mounting, the harness route and the connectors for damage, strain, heat marks, moisture and corrosion.
- Step 3, measure, do not guess. We test the sensor and wiring with a proper multimeter and compare readings with the manufacturer’s published values for the measured water temperature. We also check the harness end to end for continuity while flexing it, because intermittent breaks often only show up when the wire moves.
- Step 4, isolate the fault. Sensor, wire, terminal or control input: we narrow it to one component before recommending any part. We do not replace a control board on a hunch.
- Step 5, written quote. If the fix goes beyond the diagnosis, you get a written quote explaining the cause, the parts involved and the labour before any further work starts. Nothing proceeds without your approval.
- Step 6, repair with correct parts. The parts most often involved are the return sensor itself, a connector or section of harness, or terminal hardware. We fit parts intended for your boiler and route wiring away from heat and moving parts.
- Step 7, test the safeties. After the repair we fire the boiler, confirm the supply and return readings make sense against each other, and check the safeties, combustion, venting and condensate system before we leave. A boiler that restarts is not the same as a boiler that is working correctly.
- Step 8, explain what we found. You get a plain account of the cause and anything else we noticed, such as early corrosion, sludge in the system or a relief valve that needs attention, so you can plan ahead.
Repair or replace an older Weil-McLain boiler after an E37 lockout, and where we work in Greater Vancouver
An E37 fault on its own is almost never a reason to replace a boiler. A return sensor or a damaged wire is a contained, repairable fault on boilers of almost any age, and fixing it properly is usually the sensible answer. A sensor is one of the more modest repairs on a modern boiler; a control board is one of the more expensive parts. Ask for a written quote and decide with the facts in front of you. The question of replacement only becomes real when E37 is one symptom on a boiler that is already showing its age, such as repeated lockouts of different kinds over several heating seasons, corrosion on the heat exchanger, piping or jacket, heavy sludge that keeps returning after flushing, parts for that control generation becoming hard to source, or a boiler that was sized or piped poorly and has never kept the house comfortable.
The in-home estimate for replacing or installing a boiler is free. If you go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. A replacement is designed around your home: heat loss, existing radiators or in-floor zones, venting route, gas line capacity and where the boiler can physically sit. We pull the gas permit, arrange the inspection, and you see the full scope in writing before anything is ordered. Alongside Weil-McLain, brands we service include IBC, Navien, Rinnai, Bosch and Noritz. We are independent, so we explain the trade-offs between manufacturers neutrally.
We service Weil-McLain boilers across Greater Vancouver from our base in Burnaby, where we have worked since 1999. Housing stock varies widely across the region, and it shapes how an E37 call goes on site. Our mild, wet coastal climate means long, gentle heating seasons, which add many operating hours and heat cycles to sensors and wiring. Metro Vancouver water is soft, so hydronic trouble here tends to be sludge and corrosion rather than limescale, and the same small leaks that feed corrosion inside the system can drip onto sensor connectors outside it.
- Vancouver: many older homes have been converted to modern boilers, so the boiler often sits in a crowded basement corner where wiring and piping share tight space, sometimes with long pipe runs to older radiators.
- Burnaby and New Westminster: a mix of older detached homes, newer townhouses and strata buildings, where boilers may sit in small mechanical closets with restricted access to the sensor wiring.
- Surrey, Delta and Langley: many newer homes and townhouses with in-floor radiant heat, along with some properties where the boiler shares a garage or utility room with stored items that can be knocked against wiring.
- Richmond: in some areas homes sit on crawlspaces in low-lying ground, so moisture around mechanical equipment is worth checking whenever a sensor connector fails.
- Coquitlam and the Tri-Cities: many split-level and hillside homes with boilers on lower levels or in garages, where rodents in crawlspaces can play a part in damaged wiring.
- The North Shore: larger hillside homes often have several zones and long distribution runs, where an accurate return reading matters to how evenly the system heats.
- Wherever you are, expect a TSBC-licensed independent contractor, licensed gas fitters on every gas appliance, permits and inspections where the work requires them, and a written quote before any work beyond the diagnosis.
More questions homeowners ask
What does Weil-McLain boiler error code E37 mean?
It means the boiler’s control has detected an open circuit on the return water temperature sensor and has gone into a hard lockout. The burner will not fire, so you lose heat and, if the boiler heats an indirect tank, eventually hot water as well. The usual causes are a loose connector, a damaged wire or a failed sensor. Confirm the meaning against the manual for your unit.
Can I reset a Weil-McLain boiler showing E37?
Once, if your owner manual allows it, after checking the power switch, the gas supply valve and the thermostat. If E37 comes back, stop resetting and call a licensed technician. An open sensor circuit will not repair itself, and repeated resets add wear and can hide another fault.
Is it safe to run my Weil-McLain boiler with an E37 code?
The boiler will not run while it is locked out, and that is the safe outcome. Never bypass or jumper the sensor to force it on, because the control relies on that reading to protect the heat exchanger. If you smell gas or a CO alarm sounds, leave the home and call FortisBC or 911 from outside.
Is Weil-McLain error E37 a sensor problem or a control board problem?
Most of the time it is the sensor, its wiring or its connector, not the board. A control board input fault is possible but it is the least common cause, and it should only be diagnosed after the sensor and harness test good with a meter. Be cautious of any recommendation to replace a board without measurements to back it up.
How quickly can a Weil-McLain E37 be fixed near me in Greater Vancouver?
We offer same-day where we can, depending on the schedule and where you are in the region, and we will tell you honestly if it has to be the next available slot. Many E37 repairs are finished on the first visit when the cause is a connector or wiring. If the sensor itself has failed, the part may need to be sourced before the repair is completed.
Will an E37 lockout damage my boiler or heating system?
The lockout itself protects the boiler rather than harming it. The real risk is a cold house: during a long outage in a cold snap, pipes in exterior walls or unheated spaces can be at risk of freezing. Call early, and never run the boiler with a bypassed sensor, which is what can actually cause damage.
- Vaillant Boiler Code F.85 — Flow/return sensor fitted on the same pipe | BC Wide
- Vaillant Boiler Error Codes & Repair | Greater Vancouver | BC Wide
- Viessmann Boiler Code 02 — Safety chain / burner lockout | BC Wide
- Viessmann Boiler Code 0A — Fan speed fault | BC Wide
- Viessmann Boiler Code 0B — Wind conditions / low water flow | BC Wide
- Viessmann Boiler Code 0C — Power supply / flame-after-shutdown fault | BC Wide
- Viessmann Boiler Code 0D — Reset button pressed too often | BC Wide
- Viessmann Boiler Code 0F — Service / maintenance due | BC Wide
- Viessmann Boiler Code 10 — Outdoor temperature sensor short circuit | BC Wide
- Viessmann Boiler Code 18 — Outdoor temperature sensor open circuit | BC Wide
Frequently asked questions
How often should a boiler be serviced?
How much does a new boiler cost in Vancouver?
How long does a boiler last?
My boiler is making a banging or kettling noise. Is that dangerous?
Do you service Viessmann, IBC, Baxi, Laars, and Weil-McLain boilers?
Should I repair or replace my old boiler?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.