★ 4.7 Google rating · Serving Greater Vancouver since 1999
ServicesBrandsRebates ReviewsAboutContact 📞 Call (604) 473-9690

What a TXV Does in a Cooling System

Hvac

What a TXV Does in a Cooling System
Home › What a TXV Does in a Cooling System

What a TXV Does in a Cooling System

Key takeaways

  • A TXV is a self-adjusting valve that meters liquid refrigerant into the indoor evaporator coil so the coil stays fully used but never floods liquid back to the compressor.
  • It senses the temperature of the refrigerant leaving the coil through a small sensing bulb clamped to the suction line, and opens or closes to hold a steady amount of superheat.
  • A TXV adapts to changing indoor load and outdoor temperature; a fixed orifice or piston does not, which is why TXV systems usually hold capacity better on mild coastal days.
  • Common failure modes are a stuck-closed valve (starving the coil, icing, weak cooling), a stuck-open valve (flooding, low superheat, compressor risk), and a lost sensing-bulb charge.
  • Diagnosing a TXV requires gauges, refrigerant handling and temperature readings, all of which are restricted work in British Columbia.
  • Homeowners can safely check filters, vents and airflow first, because starved airflow imitates almost every TXV symptom.

A TXV, or thermostatic expansion valve, is the metering device in an air conditioner or heat pump that controls exactly how much liquid refrigerant is allowed into the indoor evaporator coil at any given moment. It sits at the inlet of the coil, between the high-pressure liquid line and the low-pressure evaporator, and it works like an automatic tap: it senses how cold the refrigerant vapour leaving the coil is, and it opens wider or closes down to keep that vapour at a consistent, slightly-warmed condition called superheat. The result is that the whole evaporator coil is used for cooling, and only vapour, not liquid, ever reaches the compressor. That single job is what keeps a system efficient at high load, stable at low load, and safe for the most expensive component in the whole machine.

How does a TXV actually meter refrigerant?

Refrigerant arrives at the indoor coil as a warm high-pressure liquid. On the other side of the metering device it must become a cold low-pressure mixture of liquid and vapour so it can absorb heat out of your indoor air. Something has to create that pressure drop, and something has to decide how fast liquid is fed through it. The TXV does both.

Inside the valve, a needle and seat form a variable restriction. The needle position is set by a balance of three forces. A small sealed bulb clamped to the suction line just past the coil contains its own charge; when the vapour leaving the coil warms up, that charge expands and pushes a diaphragm in the direction that opens the valve. Evaporator pressure, fed to the underside of the diaphragm through the valve body or a small equalizer tube, pushes toward closing. A spring, adjustable at the factory or by a technician on some models, sets the baseline. When the coil is working hard and vapour leaves warm, the bulb wins and the valve feeds more liquid. When the coil is barely loaded and vapour leaves nearly saturated, evaporator pressure and the spring win and the valve throttles back.

The value the valve is actually holding constant is superheat: the number of degrees the refrigerant vapour has warmed above its boiling point at the pressure inside the coil. Superheat is the honest measure of whether the coil is starved or flooded. Manufacturer literature gives the target for a given system, and it is verified with gauges and thermometers, not guessed at.

What is the difference between a TXV and a fixed orifice?

Not every system has a TXV. Many older and entry-level air conditioners use a fixed orifice, sometimes called a piston, or a capillary tube. These are simply a calibrated hole. They meter refrigerant well at exactly one set of conditions and progressively worse as conditions drift away from that point.

That distinction matters more here than in a hot dry climate. Metro Vancouver spends most of the cooling season in mild, humid weather with only short stretches of real heat. A fixed orifice sized for a design-day load tends to overfeed on a cool damp afternoon and underfeed on the hottest days. A TXV re-aims itself continuously, which is why manufacturers increasingly specify TXV or electronic expansion valve metering on matched indoor coils, and why swapping an outdoor unit without matching the indoor metering device is a common source of poor performance.

Metering deviceHow it decides flowBehaviour when load changesTypical use
Fixed orifice or pistonCalibrated hole, no moving partsOverfeeds at low load, starves at high loadOlder or budget split systems, some matched pairings
Capillary tubeLength and bore of a narrow tubeSame limitation, plus sensitive to charge accuracySmall self-contained units and older equipment
Thermostatic expansion valve (TXV)Bulb temperature versus evaporator pressure and springAdjusts continuously to hold steady superheatMost current split air conditioners and heat pumps
Electronic expansion valve (EEV)Control board driving a stepper motor from sensorsFastest and widest range of adjustmentVariable-capacity and inverter equipment

What are the parts of a TXV and what does each one do?

  • Valve body and seat: the machined passage where the pressure drop happens and where debris or corrosion products cause sticking.
  • Needle or pin: the moving element that changes the size of the opening.
  • Diaphragm or bellows: the pressure-sensitive membrane the three forces act on.
  • Sensing bulb and capillary: clamped to the suction line, it reads the temperature of the vapour leaving the coil and transmits that as pressure to the top of the diaphragm.
  • External equalizer line, on many valves: a small tube tapped into the suction line that reports true coil outlet pressure so pressure drop across the coil does not fool the valve.
  • Superheat adjustment spring: sets the baseline; it is a technician adjustment on adjustable models and not a homeowner control.
  • Inlet screen or strainer: catches debris before it reaches the seat, and can itself plug and imitate a failed valve.

What are the symptoms of a failing TXV?

A TXV that has drifted or failed produces symptoms that look, from the living room, exactly like several other faults. That is why the fault is confirmed with measurements rather than by pattern alone. The table below pairs the symptom with the mechanism behind it.

What you noticeWhat is happening at the coilCommon causes to rule out first
Weak cooling on hot days, house never quite catches upValve is not opening far enough, so only part of the coil is boiling refrigerantDirty filter, closed vents, restricted return, low charge, dirty outdoor coil
Ice or frost on the indoor coil or the suction lineCoil is starved or airflow is too low, so surface temperature falls below freezingBlocked filter, blower speed, blocked return, undercharge
Refrigerant line at the outdoor unit sweating heavily and cold to the touchValve is overfeeding, liquid is carrying past the coilOvercharge, sensing bulb loose or dislodged, valve stuck open
Cooling that surges and fades in cyclesValve is hunting because the bulb is not reading the line properlyBulb insulation missing, poor bulb contact, wrong bulb location
A hiss or gurgle audible near the indoor coilFlow through the valve seat is not steadyUndercharge, restriction, non-condensables in the system
Compressor short-cycling or tripping on a protection devicePersistent flooding or starving is stressing the compressorElectrical fault, airflow, charge, control problem

Why is a stuck-open TXV so hard on the compressor?

A compressor is built to compress vapour. Liquid does not compress. When a valve stays open too far, liquid refrigerant that should have boiled off in the coil travels down the suction line and arrives at the compressor, a condition technicians call flooding or, in its worst form, slugging. Repeated liquid return washes lubricating oil off bearing surfaces and can mechanically damage valves and pistons inside the compressor.

This is the reason superheat exists as a control target at all. Holding a modest amount of superheat is the safety margin that guarantees every drop has boiled before the vapour leaves the coil. It is also why a system with a suspected metering fault should not simply be left running while you wait for service. A compressor is the single most expensive component in the outdoor unit, and running a flooding system is the fastest way to turn a valve problem into a compressor problem.

Does anything about Metro Vancouver change how TXVs behave?

Yes, in three practical ways. First, our cooling season is short and mild. Systems here spend far more hours at part load than at full design load, which is precisely the operating band where a fixed orifice loses accuracy and a TXV keeps its footing. It is also the band where a marginal valve hides, then reveals itself during the first genuine heat stretch of the summer, which is exactly when service demand peaks across the region.

Second, the coastal air is damp. A properly fed evaporator running at the right superheat pulls a useful amount of moisture out of the air along with heat. A starved coil that has begun to frost stops dehumidifying effectively even while it appears to be working hard, so a house can feel clammy rather than merely warm. If your home feels damp on a cool day with the system running, airflow and metering are both worth checking.

Third, our housing stock is a mixture of older detached homes retrofitted with cooling and newer strata units where the indoor coil sits in a closet or above a laundry with limited access. In older retrofits, an outdoor unit is sometimes replaced without matching the indoor coil and its metering device, and the mismatch shows up as poor capacity that no amount of charge adjustment fixes. In strata buildings, access, drainage and any work touching common property usually need building or strata approval before service is scheduled. Metro Vancouver water is soft, so hydronic and boiler systems here suffer sludge and corrosion rather than heavy scale; a sealed refrigerant circuit is unaffected by water chemistry either way, but the same soft water is worth remembering when the same technician looks at your heating equipment.

What can a homeowner check, and what needs a licensed technician?

There is a genuine homeowner layer of checks, and it is worth doing first, because restricted airflow imitates nearly every TXV symptom and is far more common than a failed valve.

In British Columbia, opening a refrigerant circuit, connecting gauges, recovering or charging refrigerant, and replacing a TXV are restricted work. Refrigerant handling requires certification, and the brazing involved in changing a valve is hot work on a pressurized sealed system. Most electrical work on the equipment is likewise restricted to qualified trades. Do not attempt to adjust a superheat spring, clamp or move a sensing bulb, or add refrigerant from a store-bought can.

  • Safe for a homeowner: replace or clean the air filter, confirm supply and return grilles are open and unobstructed, clear leaves and debris from around the outdoor unit, check the thermostat mode and setpoint, and confirm the breaker is on.
  • Safe for a homeowner: shut the system off at the thermostat if you see ice on the coil or lines, let it thaw fully with the fan running, and note whether it re-forms.
  • Safe for a homeowner: write down when the symptom appears, the outdoor conditions, and any sounds; that history shortens diagnosis considerably.
  • Licensed technician only: attaching gauges, measuring superheat and subcooling, weighing in or recovering refrigerant, leak searching, brazing, and replacing the valve or the indoor coil.
  • Licensed technician only: any wiring, capacitor, contactor or control-board work at the equipment.

How is a TXV diagnosed and replaced?

A methodical diagnosis starts away from the valve. A technician confirms airflow across the coil, filter condition and blower operation, then verifies the outdoor coil is clean and the system is charged correctly, because an undercharged system starves the coil in a way that mimics a closed valve. Only then do the pressure and temperature readings mean anything.

The core measurements are superheat at the evaporator outlet and subcooling at the condenser outlet, compared against the manufacturer’s published targets for that model. High superheat with normal subcooling points toward a restriction, which may be the valve, its inlet screen, or a plugged liquid-line filter drier. Low superheat with a flooded suction line points toward a valve feeding too much or a sensing bulb that has lost contact, lost insulation, or lost its charge. A simple field test is to warm or chill the sensing bulb by hand or with a cold pack and watch whether the valve responds at all; a valve that does not react has lost its bulb charge.

Replacement means recovering the refrigerant properly, cutting or unsweating the old valve, brazing in the new one under a flow of inert gas so the inside of the tubing does not oxidize, fitting a new liquid-line filter drier, pulling a deep vacuum to remove moisture and non-condensables, then weighing in the charge and re-verifying superheat and subcooling with the system running. Skipping the drier or the vacuum is what turns a repaired system into a repeat call. Where the valve is integral to an aging indoor coil, or the coil itself is the source of a leak, replacing the coil is often the sounder decision, and on an older system that conversation should include whether continued repair or replacement makes more sense over the next several seasons. Ask for the diagnosis in writing and for a written quote before authorizing work.

Electrical safety: Refrigerant work is restricted work in British Columbia and must be done by a certified technician. Refrigerant under pressure can cause frostbite and eye injury, and brazing on a sealed system is hot work that must never be attempted on a circuit that has not been properly recovered. Do not add refrigerant yourself and do not adjust or move a sensing bulb. If your cooling equipment shares a mechanical space with gas-fired heating equipment such as a furnace, boiler or gas water heater, keep working carbon monoxide alarms on every level of the home and outside sleeping areas, keep combustion air openings clear, and never store solvents or paint near a gas appliance. If you ever smell gas, leave the building, call your gas utility from outside, and do not operate switches or your phone indoors. On the electrical side, shut off the correct breaker before removing any panel and leave wiring, capacitors and control boards to a qualified technician, as capacitors can hold a dangerous charge after power is removed. BC Wide Home Services Ltd is an independent TSBC-licensed contractor serving Metro Vancouver since 1999, licences LGA0090068 and CGA0028029. For diagnosis of a suspected metering or refrigerant fault, call (604) 473-9690.

Frequently asked questions

Can a TXV be cleaned instead of replaced?

Sometimes, but rarely with lasting success. If the restriction is at the inlet screen and the debris is loose, a technician may be able to clear the screen and fit a new filter drier. If the needle and seat themselves are pitted, corroded or gummed with oil breakdown products, cleaning does not restore accurate metering and the valve should be replaced.

How do I know whether my system has a TXV or a fixed orifice?

The equipment nameplate and the installation manual for the indoor coil state the metering device, and a technician can confirm it visually at the coil inlet during a service visit. It matters most when you are replacing one half of the system, because the outdoor unit and indoor coil have to be a matched pairing for the published performance to apply.

Will low refrigerant damage the TXV?

Not usually by itself. A low charge makes the valve open wide trying to feed a coil that has nothing to feed it, which shows up as high superheat and poor cooling, but the valve is generally still serviceable once the leak is repaired and the charge is corrected. The real risk of running a leaking system is to the compressor, which relies on returning refrigerant for cooling and oil return.

My indoor coil freezes every summer. Is that always the TXV?

No, and it usually is not. The most common cause of a frozen evaporator is restricted airflow from a plugged filter, closed vents or a blocked return, followed by low refrigerant charge. Change the filter, open the vents, let the coil thaw completely with the fan running, and if it freezes again, book a diagnosis rather than continuing to run it.

Does a heat pump have a TXV too?

Yes, and often more than one, because a heat pump has to meter refrigerant in both directions. Many systems use a pair of metering devices with check valves so that whichever coil is acting as the evaporator gets proper metering, while some newer variable-capacity equipment uses an electronic expansion valve driven by the control board instead.

Is replacing a TXV worth it on an older system?

It depends on the age and condition of the rest of the equipment and on the refrigerant it uses. On a reasonably healthy system with plenty of service life left, a valve replacement is a sensible repair. On a system that is near the end of its life, is losing refrigerant elsewhere, or runs an older refrigerant that is difficult to source, it is worth asking for both a repair quote and a replacement quote in writing before deciding.

Why does my technician talk about superheat and subcooling instead of just pressures?

Pressures on their own tell you very little without the matching temperatures. Superheat measures whether the evaporator is being fed correctly, and subcooling measures whether the condenser and the charge are right. Together they separate a metering fault from a charge fault, which is why a proper diagnosis takes both readings and compares them to the manufacturer’s published targets for your specific model.

BC Wide Home Services — Lower Mainland home-comfort specialists since 1999

Technical Safety BC Licensed Gas Contractor (LGA0090068) · Class B Gas Licence (CGA0028029) · Red Seal technicians · Evening and weekend calls · Diagnostic service calls $189.00 · Free in-home estimates on replacements (the $189.00 is waived if you replace with us). Call 604-473-9690 or book a free replacement estimate.

4.7★181+ Google reviews
27+Years serving Greater Vancouver
20+Brands serviced
$0Free written estimates on installs

Frequently asked questions

What HVAC services does BC Wide offer in Metro Vancouver?
BC Wide installs, services and repairs boilers, furnaces, heat pumps, hot water tanks, tankless water heaters, gas fireplaces and air conditioning across Metro Vancouver. We work on residential homes, townhouses, condos with strata systems, and small commercial buildings.
How long has BC Wide been in business?
BC Wide Heating & Air Conditioning has been serving the Greater Vancouver area since 1999. Our TSBC-licensed technicians have built a reputation as some of the most experienced furnace, boiler and heat-pump specialists in the Lower Mainland.
What areas do you serve?
We cover all of Metro Vancouver: Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, and Maple Ridge.
Are BC Wide technicians licensed and insured?
Yes. BC Wide holds a TSBC gas-fitting licence, our technicians are Red Seal certified for HVAC and gas, and we carry full liability insurance and WorkSafeBC coverage.
How can I book a service call?
Call (604) 473-9690, email info@bcwide.ca, or use the booking form on bcwide.ca. Most calls are answered the same business day and we offer next-day appointments for non-emergency work.
Do you offer free estimates?
Yes. Free in-home estimates are provided for boiler, furnace, heat pump and water-heater replacements. Diagnostic visits for repairs carry a flat service fee that is credited toward the repair if you proceed.
What brands do you service?
We service all major brands including Viessmann, Navien, IBC, Rinnai, Rheem, Bradford White, Weil-McLain, Laars, Baxi, NTI, Lennox, Carrier, Bryant, Goodman, Trane, York, Daikin, Mitsubishi Electric, AO Smith, Bosch, Noritz, Giant, GSW, John Wood, and Valor.
Do you offer government rebates for heat pumps?
Yes. We are a registered contractor for BC Hydro, FortisBC and federal Greener Homes rebates. A high-efficiency heat pump installation can qualify for up to $11,000 in combined rebates depending on your home and income.
How quickly can you replace a broken hot water tank?
Standard 40 or 50-gallon gas or electric tanks are typically replaced same-day or next-day from stock. Tankless water heaters and larger commercial units usually take 1–3 business days depending on parts availability.
Why should I choose BC Wide over other HVAC companies?
BC Wide Heating & Air Conditioning has been operating in Greater Vancouver since 1999 as a TSBC-licensed (LGA90068) HVAC and gas contractor. We specialise in furnaces, boilers, heat pumps and water heaters across every major brand, we give honest options instead of upselling, and our work is performed by experienced, certified staff — not subcontractors.

What Greater Vancouver homeowners say about BC Wide

Verified Google reviews — 4.7 average across 181+ ratings
★★★★★
"Alan and Mo were amazing today. They seamlessly replaced our furnace and tankless hot water tank in record time."
Mebz Esmail
Google review · Aug 2026
★★★★★
"Alan and his colleague are very friendly and professional. They installed everything and left it clean."
Laura E. Martínez Urrutia
Google review · Aug 2026
★★★★★
"I have been using BC Wide HVAC Services for over five years for my annual maintenance."
Thor Campbell
Google review · Aug 2026
★★★★★
"Excellent service from start to finish! B.C. Wide is knowledgeable, very professional and showed up on time! I highly recommend this company."
Mark Bouffard
Google review · Aug 2026
★★★★★
"I found these guys on Google. I just moved into a place where no maintenance has been done in the last 6 years."
Thomas Lee
Google review · Aug 2026
★★★★★
"Heat pump, furnace and tankless water heater installed. Competitive price. Careful, friendly, competent, efficient installation team. Professional appearing installation. Good company, highly recommended."
Thomas T
Google review · Jul 2026

Get a Free Quote — Right From This Page

Request a Free Quote

We'll call you back fast — usually within a few hours.
✓ Thanks! We've received your request and will call you back shortly.

Get Comfortable — Talk to BC Wide Today

Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.

Licensed & Insured: Technical Safety BC Licensed Gas Contractor LGA0090068  ·  Class B Gas Licence CGA0028029  ·  Red Seal Technicians  ·  Serving Greater Vancouver since 1999
🔥 Emergency Service(604) 473-9690
📞Call NowFast Response ✉️Email UsGet A Quote