A Rheem furnace error code is the control board telling you which step of the heating sequence failed, usually shown as a flashing status light or a code on a display. Start with the owner-safe checks: power switch on, gas valve open, thermostat calling for heat, filter clean and outside vent terminals clear. Reset once only if your manual allows it. If the code returns, or you smell gas, stop and call a licensed gas fitter. BC Wide services Rheem furnaces across Greater Vancouver at (604) 473-9690.
Rheem furnace error codes
Rheem furnace error codes can easily be found online with a quick search. They provide common solutions to the problems that you are facing. Rheem furnace error codes can also be a great asset for service technicians and homeowners as they help troubleshoot appliances’ problems.
—
When you have a furnace issue, use these Rheem furnace error codes to troubleshoot and fix your heating system.
When it comes to furnaces, there is always a chance that something might go wrong. When you have an issue with your furnace, check the Rheem furnace error codes listed here to start figuring out the problem with your heating system.
—
There are a lot of Rheem furnace error codes that can be confusing for the average homeowner. If you look at the link provided, it provides a list of the possible Rheem furnace error codes and their solutions.
Don’t worry if you get an error code! We’re here to help you navigate your way through it.
“Inspections, Installations, Repairs & Maintenance”
Rheem furnace experts serving Greater Vancouver
BC Wide Heating & Air Conditioning has been keeping Burnaby and Delta homes comfortable since 1999, and Rheem furnace work is exactly the kind of job our TSBC-licensed technicians handle every week. We diagnose the real problem before quoting, give you clear options instead of upselling, and stand behind our workmanship.
We hold full liability insurance and WorkSafeBC coverage, and our gas work is carried out under TSBC licence LGA0090068. Whether you need installation, repair, or a seasonal tune-up, our approach is the same: get it right the first time and leave your furnace running safely and efficiently for years.
What homeowners can expect
- fast scheduling across Burnaby, Delta and Belcarra
- respect for your home — drop sheets, clean-up, and tidy workmanship
- guidance on BC Hydro and FortisBC rebates where your system qualifies
- licensed, insured, TSBC-certified gas and HVAC technicians (licence LGA0090068)
Serving Burnaby, Delta, Belcarra and all of Greater Vancouver since 1999. For Rheem furnace service you can trust, call BC Wide Heating & Air Conditioning at (604) 473-9690 for a free, no-obligation quote.
When you have a furnace issue, use these Rheem furnace error codes to troubleshoot and fix your heating system: what the code means for you
A Rheem furnace does not throw an error code at random. Every heating cycle runs through a fixed sequence: the thermostat calls for heat, the inducer fan starts to clear the heat exchanger, a pressure switch confirms the venting is moving air, the ignitor heats up, the gas valve opens, and a flame sensor proves there is a flame before the main blower comes on. If any step fails its check, the control board stops the sequence and records why. The flashing light or display code is simply the board telling you which step failed. On many Rheem furnaces the status light sits on the control board and can be seen through a small window in the lower door, while some newer models use a display instead. Confirm against the manual for your unit, because code meanings differ between model families and board generations, and the code chart for your exact furnace, usually on a label on the unit or in the owner manual, is the one that applies.
For you as the homeowner, a code usually means one of three things. First, no heat or only short bursts of heat, because the furnace locked itself out after failed attempts to light. Second, a safety device did its job: a pressure switch, flame sensor or high-limit switch shut the burner down because something was not right. Third, a warning that the furnace is still running but something is drifting out of range, such as a weak flame signal or restricted airflow. None of these are reasons to panic, but none of them should be ignored or reset over and over either. A code that keeps coming back is a furnace asking for a proper diagnosis.
Because a gas furnace is a combustion appliance, its codes are also tied directly to safety. Codes linked to venting, flame proving or overheating are exactly the faults that protect your household from carbon monoxide and from overheated components. That is why the owner-safe steps further down this page stop well short of opening the furnace.
Here is what owners usually tell us when they call about a Rheem furnace code, in their own words:
- The furnace clicks, tries to start, then goes quiet and the little light keeps blinking.
- The fan runs but only cold air comes out of the vents.
- It heats for a few minutes, shuts off, then starts again, over and over.
- There is a humming or whirring sound from the furnace but no flame.
- The light on the furnace is flashing a pattern I don’t recognise.
- It worked again after I flipped the switch off and on, but the problem was back the next morning.
- There is water around the base of the furnace and a code is showing.
What causes Rheem furnace error codes? Likely causes, most common first
On service calls across Greater Vancouver the same handful of causes come up again and again. The table below runs roughly from the causes we find most often to the ones we find least often in our day-to-day work, with the check an owner can safely make and the point where it becomes a job for a licensed gas fitter. It is a guide to what usually sits behind a code, not a replacement for the code chart for your model.
Notice that the first four causes are the ones an owner can often spot without tools. Flame sensors, ignitors, inducers, pressure switches and control boards are a different matter: the furnace has to be opened, gas and electrical components tested while live, and the safeties proven afterward. A control board is one of the more expensive parts on a gas furnace, which is why we never replace one until the rest of the sequence has been tested. Boards get blamed for a lot of faults that actually started at a blocked drain, a cracked pressure-switch hose or a dirty flame sensor.
| Likely cause | What you may notice | Owner-safe check | When it becomes a licensed call |
|---|---|---|---|
| 1. Dirty or blocked air filter | Short heating cycles, hot-smelling air, furnace shutting down on overheating | Replace the filter with the size printed on the old frame and open any closed supply registers | The code returns with a clean filter, or a blower or duct restriction is suspected |
| 2. Thermostat or power problem | No call for heat, blank thermostat, furnace not responding at all | Check thermostat mode, set point and batteries, the furnace service switch and the breaker | The breaker trips again, or thermostat wiring or a transformer fault is suspected |
| 3. Blocked outside intake or exhaust terminal | Inducer runs, then the furnace stops before lighting | Clear leaves, snow, ice or nests from the pipe openings by hand without moving the pipes | Terminals are clear but the fault repeats, or any vent pipe is cracked, sagging or disconnected |
| 4. Blocked condensate drain or trap | Water near the furnace, gurgling, venting-related faults on high-efficiency units | Look for a kinked or disconnected visible drain hose or a full condensate pump reservoir | Any trap cleaning inside the cabinet, pump replacement or internal drain work |
| 5. Dirty or failing flame sensor | Burner lights for a few seconds, shuts off, retries, then locks out | None inside the furnace; note how many tries happen before it stops | Always, because sensor cleaning and flame-signal testing mean opening the burner compartment |
| 6. Worn or cracked hot surface ignitor | Clicking and inducer noise but no glow and no flame | None inside the furnace | Always, because ignitor testing and replacement is technician work |
| 7. Gas supply problem | No flame on any attempt, other gas appliances also not working | Confirm the furnace gas shut-off handle is in line with the pipe and other gas appliances run | Any suspected supply, pressure or gas valve fault; a gas smell means leave and call from outside |
| 8. Inducer motor or pressure switch fault | Loud or rattling inducer, or the furnace never moves past the start of the cycle | Listen and note the sound; do not touch the motor or its tubing | Always, because pressure readings and component tests need a manometer and a licensed fitter |
| 9. Control board fault | Erratic codes, no code at all, or several unrelated faults at once | Write down the code exactly as shown through the door window | Always, and a board is diagnosed last, after every other component is proven |
Can I reset a Rheem furnace error code myself? Owner-safe steps and where to stop
You can do a few things safely without tools and without opening the furnace. Work through them in order and stop the moment anything looks, smells or sounds wrong.
What you should never do: remove the burner or blower doors to look at the board, jumper or bypass a pressure switch or limit switch, tape down a door safety switch, sand or bend a flame sensor, or reset the furnace again and again to get a few more minutes of heat. Repeated resets on a flame or venting fault can send unburned gas through the heat exchanger and keep stressing parts that were already failing. In BC, work on gas components and on furnace wiring belongs to licensed trades, and those safeties exist to protect the people sleeping in the house.
Safety first, every time. If you smell gas, the rotten-egg or sulphur smell added to natural gas, or your carbon monoxide alarm sounds, do not reset anything and do not operate light switches or appliances. Get everyone out of the house, pets included, and call FortisBC’s emergency line or 911 from outside. Headache, dizziness, nausea and unusual drowsiness that ease when you step outside are warning signs of carbon monoxide. Every home with a gas furnace should have working CO alarms near the sleeping areas, tested regularly.
It becomes a licensed call when the same code comes back after one reset, when the furnace short-cycles, when you see scorch marks, rust flakes or water inside the cabinet window, when a vent pipe is cracked or disconnected, when you hear a bang or a loud whoosh on ignition, or whenever the fault involves flame, gas or venting at all.
- Write the code down first. Record the flash pattern or display reading exactly as it appears through the door window before you touch anything, because cutting power can clear it.
- Check the thermostat. It should be set to heat, the set point should be above room temperature, and batteries, if it uses them, should be fresh.
- Check power. The furnace service switch, which often looks like an ordinary light switch on or near the furnace, must be on, and the breaker must not be tripped. Reset a tripped breaker once only; if it trips again, leave it off and call.
- Check the gas shut-off. The manual valve on the gas line to the furnace should have its handle in line with the pipe. Do not operate any other valve and never touch the gas control inside the furnace.
- Check the filter. A clogged filter is the most common reason a furnace overheats and locks itself out. Replace it with the size printed on the old filter frame.
- Check outside. On a high-efficiency furnace the plastic intake and exhaust pipes end outside the house. Gently clear leaves, snow or a nest from the openings by hand, and do not pull on, cut or reposition the pipes.
- Check the visible condensate drain. Look for a kinked, disconnected or overflowing drain hose or a condensate pump that is full or not running. Report what you see rather than taking the trap apart.
- Reset once, and only if your owner manual allows it. Turn the service switch off, wait as long as the manual says, and turn it back on. If the same code returns, leave the furnace off and book a diagnosis.
How our Rheem furnace repair visit works, step by step
When you call (604) 473-9690 about a Rheem furnace error code, this is what a correct repair visit looks like from our side. We book same-day where we can, depending on the day’s workload and where our technicians already are. On the busiest cold-snap days that is not always possible, and we will tell you honestly when we expect to arrive rather than promise a window we cannot keep. Diagnostic service calls are $189.00.
The parts most often involved in Rheem error-code repairs, in general terms, are filters and other airflow items, condensate traps, hoses and pumps, flame sensors, hot surface ignitors, pressure switches and their tubing, inducer motors, limit switches, and less often control boards or gas valves. We fit parts that match your model and do not swap in a universal part where the manufacturer specifies a matched one. If your furnace is still within its manufacturer warranty, keep the registration details handy; claims run on the manufacturer’s own terms, and we document what we find so you can check your coverage.
Who does the work matters on a gas appliance. BC Wide Home Services Ltd is an independent contractor licensed by Technical Safety BC, contractor licence LGA0090068, with Class B gas licence CGA0028029, serving Metro Vancouver homes since 1999. Our gas fitters are licensed, and where the work needs a permit, such as replacing a furnace or altering gas piping or venting, we pull the permit and the work is open to inspection. We are not a factory-authorised dealer or warranty centre for any manufacturer. Rheem is a brand we service, alongside the other gas furnace brands we see in local homes, including Ruud, Lennox, Carrier, Bryant, Trane, American Standard, Goodman, Amana, York and Daikin.
- 1. We listen first. The technician asks what you saw, the code you wrote down, when it started and what you already checked, so nothing is repeated and nothing is missed.
- 2. We read the board. We read the active code and, on boards that store one, the fault history, which often tells a clearer story than the code showing today.
- 3. We watch a full cycle. We call for heat and watch the sequence from inducer start to blower, because the step where it fails points to the cause.
- 4. We measure rather than guess. A manometer for gas and venting pressures, a multimeter for voltage and component resistance, a flame-signal reading in microamps, a combustion analyser where combustion is in question, and a CO check around the appliance.
- 5. We find the cause, not only the failed part. A pressure switch may be the part that failed; a sagging vent or a blocked trap may be the reason it failed. You hear about both.
- 6. You get a written quote before any work beyond diagnosis. Parts, labour and options are in writing, and you decide before we start.
- 7. We repair and then prove the safeties. We test the limit switch, pressure switch and flame-proving sequence, leak-test any gas fitting we disturbed, and confirm venting and combustion are safe before we leave.
- 8. We explain and document. You get a record of the code, the cause, what was replaced and what was tested, plus anything we noticed that you should plan for.
Repair or replace an older Rheem furnace that keeps showing error codes?
A single error code on a sound furnace is usually a repair. A furnace that shows a different code every few weeks is a different conversation. We weigh the same factors on every older unit and put them in writing so you can make the call yourself.
When replacement makes sense, we lead with dual fuel: a heat pump paired with a modern gas furnace, with the heat pump carrying most of our mild, wet heating season and the gas furnace taking over as backup during cold snaps. It keeps the reliability of gas heat while reducing how often the furnace has to fire. A straight furnace-for-furnace replacement is also a perfectly good option for many homes, and where both fit we quote both so you can compare.
The in-home estimate for a replacement or new installation is free. If you had a diagnostic visit and then go ahead with a replacement or new installation through BC Wide, the $189.00 diagnostic charge is waived and taken off the installation. Every replacement quote is written, spells out the scope of the work and includes the permit.
- Condition of the heat exchanger and burners. Cracks, heavy rust or signs of flame roll-out push the decision toward replacement, because those are safety problems, not comfort problems.
- Age and repair history. An older furnace with several recent repairs is often spending money on parts that will soon be followed by more parts.
- Part availability. Some older control boards and inducer assemblies become harder to source as model lines change.
- Venting and sizing. Many older homes have furnaces that were oversized or venting that was modified over the years, and a replacement is the right moment to correct both.
- Comfort complaints. Cold rooms, noise and uneven heat are often duct and sizing issues that a new installation can address and a repair cannot.
- Your plans for the house. If you are selling soon, a safe repair may make more sense; if you are staying, a new furnace or a dual-fuel system may serve you better over its life.
Rheem furnace error code service near me in Greater Vancouver
We work on Rheem furnaces across Greater Vancouver from our base in Burnaby, and the code on the board often says as much about the house the furnace is installed in as about the furnace itself. Housing stock varies street by street, so the notes below are general patterns, not rules.
Strata townhomes and condos in all of these cities add one step: some work, especially venting changes or equipment replacement, may need strata approval before it begins. We can provide the written scope your strata council or property manager asks for.
Our mild, wet coastal climate shapes these calls too. Furnaces here run long, gentle cycles for much of the year, high-efficiency units produce plenty of condensate, and leaves and moss build up quickly around outdoor terminals in autumn. A good share of the Rheem error-code calls we answer in October and November trace back to a blocked drain or a terminal choked with leaves rather than a failed part, which is why the outside check in the owner-safe list is worth doing first.
- Vancouver: a mix of older character homes, often with furnaces in tight basements and venting that has been changed more than once, and newer townhomes with compact mechanical closets.
- Burnaby: our home area, with many houses where the furnace has been replaced at least once while the original ductwork stayed in use.
- Surrey: everything from older houses to large newer subdivisions, where long vent runs and condensate routing can play into venting-related faults.
- Richmond: low-lying, damp ground and many crawlspace and garage installations where condensate drains and outside terminals need regular attention.
- Coquitlam and the Tri-Cities, including Port Coquitlam and Port Moody: hillside homes and wet, leafy lots where intake and exhaust terminals collect debris.
- The North Shore, including North Vancouver and West Vancouver: higher, wetter and sometimes snowier sites where a buried terminal or a frozen condensate line can cause winter lockouts.
- New Westminster: older housing and conversions where shared walls and tight clearances affect venting and service access.
- Delta: a long-standing service area for us, with many family homes whose furnaces sit in garages or utility rooms.
- Langley: newer and rural properties alike, with longer drives that we factor into honest arrival times.
More questions homeowners ask
What does a flashing light on a Rheem furnace mean?
It is the control board reporting its status, and a pattern different from the normal one described in your manual points to a specific fault or lockout. Read the pattern through the door window without removing any panels and compare it with the code chart for your model. Confirm against the manual for your unit, because meanings differ between model families and board generations.
Can I reset a Rheem furnace error code?
Yes, once, and only if your owner manual allows it, by turning the furnace service switch off, waiting the time the manual gives and turning it back on. Write the code down before you reset, because cutting power can clear it. If the same code returns, leave the furnace off and book a licensed technician rather than resetting again.
Is it safe to run my Rheem furnace with an error code showing?
Not if the code relates to flame, gas pressure, venting or overheating, because those faults are the furnace protecting you from carbon monoxide and damaged parts. If you smell gas or your CO alarm sounds, leave the house and call FortisBC or 911 from outside. For any repeating code, turn the furnace off and have it diagnosed before relying on it.
Why does my Rheem furnace keep showing the same error code after a reset?
Because a reset clears the lockout but does not fix the cause. The usual suspects are a dirty filter, a blocked outside terminal, a plugged condensate drain, a dirty flame sensor or a failing pressure switch or ignitor. Once the owner-safe checks are done and the code still comes back, the furnace needs testing with proper meters by a licensed gas fitter.
How much does it cost to diagnose a Rheem furnace error code?
Diagnostic service calls are $189.00. After the diagnosis you get a written quote for any repair before work goes further. If you decide to replace the furnace or install new equipment through BC Wide instead, the $189.00 diagnostic charge is waived and taken off the installation.
Do you repair Rheem furnaces near me in Greater Vancouver?
Yes. BC Wide services Rheem furnaces in Vancouver, Burnaby, Surrey, Richmond, Coquitlam and the Tri-Cities, the North Shore, New Westminster, Delta and Langley. We are an independent TSBC-licensed contractor, not a factory dealer, and we book same-day where we can. Call (604) 473-9690 to arrange a visit.
- Weil-McLain Boiler Code E52 — Flue temperature too high | BC Wide
- Weil-McLain Boiler Code E60 — Parameter reading error | BC Wide
- Weil-McLain Boiler Code E61 — Airflow circuit failure | BC Wide
- Weil-McLain Boiler Code E65 — Insufficient blower force / blower restart fault | BC Wide
- Weil-McLain Boiler Error Codes & Repair | Greater Vancouver | BC Wide
- Weil-McLain Boiler Error Codes & Troubleshooting in Greater Vancouver
- Whirlpool Furnace Error Codes
- Why does my Navien have no error code but no hot water?
- Keeprite furnace error code 6
- York Furnace Code 2 flashes — External lockout (retries exhausted) | BC Wide
Frequently asked questions
How often should a furnace be serviced?
How long does a furnace last in Vancouver's climate?
Why is my furnace blowing cold air?
How much does a new furnace cost in Vancouver?
What is the most reliable furnace brand?
What HVAC services does BC Wide offer in Metro Vancouver?
How long has BC Wide been in business?
What areas do you serve?
What Greater Vancouver homeowners say about BC Wide
Get a Free Quote — Right From This Page
Request a Free Quote
Get Comfortable — Talk to BC Wide Today
Free, no-obligation quotes. TSBC-licensed local technicians serving Greater Vancouver since 1999.